| 1 | Demolition of cement concrete (unreinforced)in ground floors and pavings not exceeding 15 cm thickness.(below or above ground level) Complete all as specified and directed. |
| 2 | Demolition brick work or stone/ boulder masonery built in cement mortar including all quoins , pillars etc |
| 3 | Excavating over areas, n exc 1.5m deep and gettingout in Hard/dense soil complete all as specified and directed. |
| 4 | Same as item no 3 but depth exc 1.50m but not exc 3.00 m |
| 5 | M&L for PCC (1:2:4) type B2 (40 mm graded aggre-gate) as in foundations, filling and mass-concreteincluding haunching against pipe complete all as specified and directed. |
| 6 | M&L for brick work using sub class ‘B’ old size bricks, straight or curved on plan exceeding6m mean radius, built in CM (1:6) complete al as specified |
| 7 | M&L for 15mm thick plastering on fair faces of brick wall in CM (1:4), surface finished even and fair mixed with WPC as per manufacturer\"s instruction complete all as specified and directed.Note :- WPC shall be measured and paid separately as supply only. |
| 8 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) Flat including fair fininsh. |
| 9 | Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide, Flat including fair fininsh. |
| 10 | M&L for RCC (1:2:4) Nominal mix (using 20mm graded stone aggregates) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, and in shelves complete all as specified and directed. |
| 11 | M & L for providing plain cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate) as in coping, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. |
| 12 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in Hard/ Dense soil complete all as specified and directed. |
| 13 | Demolition and breaking up drain pipes 150 mm (salts glazed ware ,AC or Reinforced concrete) set in cement mortar all as specified |
| 14 | M & L DWCPE (SN8) 180 (OD)/163(ID) mm diameter Pipes laid in trenches and jointed as required complete all as specified and directed. |
| 15 | M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150mm bore complete all as specified and directed. |
| 16 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and directed. |
| 17 | Removing Excavated soil exceeding 250 M but not exceeding 500 M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed. |
| 18 | Demolition of reinforced cement conc. Of any description and in any position including reinforcement cut as required to facilitate demolition complete all as specified and directed. |
| 19 | M & L providing precast cement concrete 1:2:4 type B1(20mm graded aggregate) as in cover slab for manholes, landing etc. setting in cement mortar 1:6 complete all as specified and directed. |
| 20 | S & F M.S. TMT bars 10mmdia and over, cut to length,bent in shape required, including cranking bending hooks ends and binding with M.S.wire(annealed) not less then 0.9mm dia complete all specified & directed. |
| 21 | M&L for Cement concrete 1:2:4 in haunching and benching for manholes complete all as specified and directed |
| 22 | S&F cast iron(Spun pipes) 75mm soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors. |
| 23 | Supply only of liquid water proofing Compound for 5mm rendering. |
| 24 | Construction of Soakage wells, excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of brick masonary in CM, RCC cover slab in M25/ SRFC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.80 M dia X 3.00 M effective depth all as specified and directed. |
| 25 | M & L for PCC 1:3:6 (20 mm graded aggregate)as surface channelfor drain complete all as specified and directed. |
| 26 | Extra for forming fair finished drain or channel 30 cm inner girth in cement complete all as specified and directed. concrete, using ex- tra cement, including forms, moulds, mi-tred/stopped ends etc.All as specified and directed. |
| 27 | M&L 75 mmthick cement concrete 1:4:8 type D-2 finished fair and even as in sub base Complete all as specified and directed. |
| 28 | M & L for 15 mm thick screed bed or bedding layer in CM 1:6 to receive floor finishes complete all as specified and directed. |
| 29 | M&L for chequred cement concrete tiles of size 300x300x25 mm thick coloured rubber pressed glossy finish, set and jointed in neat cement slurry and pointed in white or colour cement and match the surace of tiles as foor/staps, complete as all specified and directed. |