| 1 | Excavation in trenches n. exc. 1.5 mtr wide and not exc. 1.5mtr in depth for foundation of pole and laying of CI/ GI/ DI/ PPR pipe and getting out in soft/loose of soil, complete all as specified and directed by Engr-in-charge. |
| 2 | Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed by Engr-in-charge. |
| 3 | Returning filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed by Engr-in-charge. |
| 4 | M&L as in repairs to sluice valve 80mm dia after replacement of gland packing, nuts & bolts and brass spindle, fixed on the existing GI/ DI/ PPR pipe line with leather gasket of suitable thickness complete all as specified and as directed. |
| 5 | All as per Serial item No. 4.00 here-in-before but 100 mm dia. |
| 6 | All as per Serial item No. 4.00 here-in-before but 150 mm dia.Note For Item No 4.00 to 6.00 : Rate quoted shall inclusive of gland packing, nuts, bolts and brass spindle. |
| 7 | M&L as in repair the leakage/ damaged to CI /DI /MS /GI andPP-R ofsize 40-80mm dia pipe line at any location, as directed by Engr-in-charge with required earth works, jointing materials such as lead wool/ leather gasket / rubber gasket ring /push on joint / socket / union or as required at site for pipe fittings for CI /DI /MS/ GI pipe line with reqd nuts/ bolts/ washer and necessary welding works, etc. (as reqd.) including necessary T&P complete all as specified and as directed. Note : (i) Necessary excavation and earth work (as required) shall measured and paid separately. (ii) Jointing material, lead wool, gasket, nuts bolts shall inclusive of rate quoted. |
| 8 | All as per Serial item No. 7.00 here-in-before but of size 100- 200 mm dia pipe line |
| 9 | Supply and fix Ductile iron sluice valve flange type of 150 mm dia PN 1.6 grade with stainless steel spindle& brass check nut (non raising spindle type conforming to IS - 14846) including fixing to pipe line with nuts, bolt and washers, rubber gaseket (neouprene) complete all as specified and directed. |
| 10 | Supply and fix Ductile iron sluice valve flange type of 100 mm dia PN 1.6 grade with stainless steel spindle& brass check nut (non raising spindle type conforming to IS - 14846) including fixing to pipe line with nuts, bolt and washers, rubber gaseket (neouprene), complete all as specified and directed. |
| 11 | S&F sluice valves 80 mm dia PN 1.6 (Conforming to IS:14846L (2000) having brass spindle , should be fixed on existing GI/CI pipe line through leather gasket of suitable thickness including taking down old one all as specified and directed Make : Kirloskar/Audco/Upadhyaya. |
| 12 | Supply and fix Ductile iron Non returnvalve of size 100mmand Taking outold unserviceable NRV ISI marked including complete fitting item with jointing materials such as nuts, bolts, washers and rubber gasket etc of suitable size all as specified and directed. |
| 13 | Supply and fix Ductile iron butterfly valve of size 100 mmand Taking outold unserviceable butterfly valve ISI marked including complete fitting item with jointing materials such as nuts, bolts, washers and rubber gasket etc of suitable size all as specified and directed. |
| 14 | Material and labour for Cutting cast iron pipes of size 100/ 80 mm bore and reducing to required length before laying in position for insertion of new tees, branches, etcor taking branches connection complete all as directed. |
| 15 | Material and labour for Drilling and tapping DI/cast iron water mains (in position) for branch connections of the internal dia 15mm bore complete all as directed. |
| 16 | Material and labour for Drilling and tapping DI/cast iron water mains (in position) for branch connections of the internal dia 20mm bore complete all as directed. |
| 17 | Taking up old U/S GI pipe and connections ofsizes 40/50 mm bore . |
| 18 | Taking up old U/S GI pipe and connections ofsizes 25 mm bore . |
| 19 | Taking up old U/S GI pipe and connections ofsizes 20 mm bore . |
| 20 | Taking up old U/S GI pipe and connections ofsizes 15 mm bore . |
| 21 | Supply and fix of Galvanised Ironpipe, medium grade, laid in trench ,with all fittings such as tees, bend, elbows, sockets reducer, nipples and union of size 50 mm dia bore, complete all as specified and directed by Engr-in-charge. |
| 22 | Supply and fixing Galvanised Ironpipe, medium grade, laid in trench ,with all fittings such as tees, bend, elbows, sockets reducer, nipples and union of size 40 mm dia bore, complete all as specified and directed by Engr-in-charge. |
| 23 | Supply and fixing Galvanised Ironpipe, medium grade, and fixed complete to walls and ceilings or laid in trench with all fittings such as tees, bend, elbows, sockets reducer, nipples and union of size 25 mm dia bore, complete all as specified and directed by Engr-in-charge. |
| 24 | Supply and fixing Galvanised Ironpipe, medium grade, and fixed complete to walls and ceilings or laid in trench with all fittings such as tees,bend,elbows,sockets reducer, nipples and union of size 20 mm dia bore, complete all as specified and directed by Engr-in-charge. |
| 25 | Supply and fixing Galvanised Ironpipe, medium grade, and fixed complete to walls and ceilings or laid in trench with all fittings such as tees, bend, elbows, sockets reducer, nipples and union of size 15 mm dia bore, complete all as specified and directed by Engr-in-charge. |
| 26 | Supply and fix of new 50mm dia gun metal gate valve conforming to ISwith iron wheel head screwed both ends for iron pipe including Taking out old unservicesble gate valve, complete all as specified and directed by Engr-in-charge. |
| 27 | Supply and fix new 40mm dia gun metal gate valve conforming to ISwith iron wheel head screwed both ends for iron pipe including Taking out old unservicesble gate valve, complete all as specified and directed by Engr-in-charge. |
| 28 | Supply and fix new 25mm dia gun metal gate valve conforming to ISwith iron wheel head screwed both ends for iron pipe including Taking out old unservicesble gate valve, complete all as specified and directed by Engr-in-charge. |
| 29 | Supply and fix new 20mm dia gun metal gate valve conforming to ISwith iron wheel head screwed both ends for iron pipe including Taking out old unservicesble gate valve, complete all as specified and directed by Engr-in-charge. |
| 30 | Lifting and Lowering for repair etc. oftheheavy duty flanged column pipe of 80mm to150 mm bore length not exceeding 100 mtr existing size etc. by dismantling the bolts nuts washers, rubber flangedetc andtaking out and lowering of submersible pump set along with the submersible cable complete all asdirected. Note :(i) Rate quoted shall inclusive leather gasket ,rubber flanged as required at site.(ii) Nuts, bolts and washer shall be paid separately. |
| 31 | Supply and fix MS Nuts, bolts & washers of suitable size matching with the existing flange of borewell complete all as directed. |
| 32 | Material and labour painting with two coats of aluminium paint over a coat of red oxide metal primer after preparation of external surface of the shell of IRP\"s by scrapping of existing paint all as directed.(a) Iron Removal plant of Officer Mess 19 wing(b) Iron Removal Plant of Near Base Ops 19 wing.(c) Iron Removal Plants of AKM Site \"A, area. |
| 33 | Material and labour painting with two coats of synthetic enamel paint over a coat of red oxide metal primer after preparation of external surface of pressed steel tanks/ladders/raising mains, delivery mains, wash out and overflow pipe line of OH reservoir by scrapping of existing paint all as directed including arrow mark showing water flowing direction. |
| 34 | Material & labour for two coats of wheather coat/Cement based paint on RCC Over head tank of approx height of 25Mtr, before painting scraping of old paint is to be carried out and painting includes pillars ,Doors,and writting of the capacity of Over Head Tank etc of RCCOver head tank complete all as directed by Engr -in-charge. Note : Rate quoted shall inclussive necessary scuffolding for paint work. |
| 35 | Supply and fix mild steel framed work as ladder, cleatsand similar work in RCC Over Head water tank conforming to Fe 410-W by welding or screwing including nuts, bolts, washers etc. all as specified and directed. |
| 36 | Supply and fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 37 | M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161 1979 grade St.-240 |
| 38 | Excavating in post holes (or similar holes) each not exc 0.5Cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm all as specified and directed. |
| 39 | M&L for cement concrete in foundations filling and fxing of angle iron Post etc. mass concrete Type C1 1:3:6, using 20mm graded aggregate all as specified and directed by Engr-in-charge. |
| 40 | M&L for cement concrete in foundations,filling and mass concrete Type C2 1:3:6, 40 mm graded aggregate all as specified and directed by Engr-in-charge. |
| 41 | M&L for cement concrete in foundations, filling and mass concrete Type B1 1:2:4, 20 mm graded aggregate all as specified 8369 and directed by Engr-in-charge. |
| 42 | M&L for collection of water sample from Pump Houses or any other indicated location, submission the water sample to any Government Laboratories (National Test House or eqvt Labs), testing the following parameters of water sample a) organoleptic and physical parameters b) general parameters concerning substances undesirable in excessive amounts c) parameters concerning toxic substances d) pesticide residues limits e) bacteriological quality of drinking water (as per IS 10500 : 2012 & ICMR guidelines) and submission the Test Report to Engr-in-Charge within 30 days of collection of water sample. |
| 43 | Supply, lowering & fixing 10.0 mm dia flexible PVC coated steel rope - 40 RM for holding submersible pump inside the casing pipe and fixed outside at the mid of MS channel with provision of 01 no pulley all as specified & directed. |
| 44 | Supply, connecting & fixing of PVC insulated PVC sheathed 3 core flat copper cable of size 6 sqmm, 1100 V grade conforms to IS 694:2010 ISI without any joint all as directed. Make : Plaza /Finolex /Havells/Richa |
| 45 | Supply, fixing and testing in repair the ERW Sreel heavy duty suction pipe both end flanged of 100 mm diaset suitable for suction pipe of centrifugal pumps installed at main pump house, complete all as specified and directed. |
| 46 | Supply PRIFIL MW 20 REFILL Safe water pre-filter corrosion & scale inhibitor refills for prefills capsule of following specifications : Height :51 CM, Must be capable of forming protective films on pipe interos Must prevent precipitation of calcium, Magnesium & Iron Minimise red water problem by complecation with Iron FIlter porosity :180 Microns, Presuure :1.5 Mpa Tempreture :45 Digree Centigrate. Service :Municipal & bore well water Refill shelf life: Maximum six months from date of first user or one year from manufcturing, whichever earlier.complete all as directed by Engg - in - Charge . |
| 47 | Supply of calcium Hypochlorite which is dry free flowing and free from lumps,Toxic & undesirable substance should not induce substances beyond acceptable limit as given in IS 10500 (2012) in treated and disinfected water of packing capacity 45 KG in each drum having min 55% chlorine content in granular from calcium Hydroxide Max 4%, sodium max 15% and particle size (passing through 1.70 mm SI sieve) fortfied with corrosion inhibitors and anti scalants for drinking water disinfection.Note : Bidder should submit the corrosion inhibitor and Anti scaling agent certificate of particular OEM which must be ratified by E-in-C\"s letter. |
| 48 | Supply of chlorine tablets contained in plastic cylindrical sealed disposal sanitiser refill (dia 2.5 inches +- 0.5 inches height 10 inches +-0.5 inches) for disinfection of drinking water with arrangement for controlled realese of disinfactant in water, suitable for operation through dosing system Make : Declibac (Type Stequa 411 AE) / Eqvt approved make.Note : The product media should have heavy metal contminants below etectable limits & must pass acute toxicity test (conform to non for mammalian cells) and safe for human health safety point. |
| 49 | M&L for cleaning of semi underground sumps of 1 Nos of 10000 Gallon capacity each through 7 stages of cleaning and sterilization consisting of the following stages complete all as specified and as directed by Engr-in-Charge. for semi underground sump 10000 Gallon capacity. Location : 19 Wing Air Men Mess (1X Garud Block and 1X Bahdur Block ,1X AKM Site \"A\" Area) Contd..... |
| 50 | (a)First stage is to drain out the water by using monoblock Diesel engine pumpset of suitable capacity .(b)Second stage is cleaning all the algae formation inside the tank by using TERBAC-G5 a laboratory tested branded chemical.(c) Third stage is scrubbing the walls with mechanized scrubber & fresh water cleaning by high speed jet pump.(d)Fourth stage and first bacteria screening is Sterilization by using TERBAC-G5 a Laboratory certified branded halogen compound, test certificate of TERBAC-G5 from government laboratory mentioning suitability for sterilization should be submitted to the office before using for sterilization . Contd... |
| 51 | (e )Fifth stage is cleaning the floor and wall of UG Sump with pressur Jet pump and drain out the water.(f)Sixth stage is the second bacteria screening and sterilizing method by using ultra violet ray with in the tank and kills all suspended bacteria.Note : (I) All T&P, PPE Kit, Transport shall be provided by the contractor without charging any extra cost.(II) ALL THE CLEANING & STERILIZATION STAFFS SHOULD BE UNDER ACCIDENTAL INSURANCE COVERAGE. (III) Date of cleaning of tank should be written on the outer surface of tank in white letter over black background complete all as directed. |
| 52 | All as per Sr. Item No. 49.00 here in before but for overhead P S tank of 9600 Gallon capacity - 01 Nos Location - Base Ops Area |
| 53 | All as per Sr. Item No. 49.00 here in before but for overhead P S tank of 9600 Gallon capacity - 01 Nos Location - Tech Area |
| 54 | All as per Sr. Item No. 49.00 here in before but for overhead RCC tank 30000 Gallon capacity - 01 Nos Location - Officer Mess area 19 wing. |
| 55 | Supply, lowering & fixing 10.0 mm dia flexible PVC coated steel rope - 40 RM for holding submersible pump inside the casing pipe and fixed outside at the mid of MS channel with provision of 01 no pulley all as specified & directed. |
| 56 | Supply, connecting & fixing of PVC insulated PVC sheathed 3 core flat copper cable of size 6 sqmm, 1100 V grade conforms to IS 694:2010 ISI without any joint all as specified & directed. Make : Plaza /Finolex /Havells/Richa |
| 57 | M&L for 3 Phase Star Delta Starter for submersible pump with MCB, with Single Phase preventer with Over load Relay with Contractor, Ammeter & Volt meter (DeluxeModel) in Sheet steel housing, three phase 415 Volt 50 Hzof capacity 20 HP, 15KW, Relay range - 13.2 to 20 Ampsall as directed. Make : HPL(SDMS50S3C20L20A6)/ L&T or equivalent in Schneider electric / BCH |
| 58 | S & F single phase and reverse phase preventor with accessories suitable for electric motor 12.5- 20 HP capacity with necessary electrical connection by using proper size of single core copper wire complete including taking down/ removing old U/S ones with necessary electrical connection complete as directed.by Engr-in-Charge Make :- L &T/ Simens or equivallent. |
| 59 | Supply and fix in repair of bore well Submerisible pump set with motor, 415 volts, 3 phase 50 Hz of discharge 30 to 65 Cum/Hrs and of head 60 to 80 meter of bore size 10\" complete all as specified and testing on completion . |
| 60 | Supply only Chlorine test kit with coloured ample complete with all testing fitments and OT solution in Rxene finish box |
| 61 | Supply only OT Solution for chlorine test (500 ML Bottle) |
| 62 | Dismantling and lowering down pressed steel side plates of size 1.22Mx1.22M of 6 mm thickness from pressed steel water tank of 40 feet staging carefully without damage to other members after necessary unscrewing of bolts, nuts, washers etc including saparating serviceable side plates and kept in safe custody for reuse in the same work complete all as specified and directed by Engr-in -charge Note : \"Cost of making of staging for repairing of OH PS Tank is demmed to be included quoted rate. |
| 63 | Supply, errection, hoisting and fixing of new pressed steel side plate of 1.22Mx1.22M, made to required shape and drilling necessary holes for fixing of bolts and nuts in existing pressed steel water tank on 40 feet staging complete all as specified and directed. |