| Sl. No. | Item Description |
| 1 | M&L for Taking down chowkhats or frame with shutters (without taking off shutters from frame)each exceeding 1.50 Sqmbut not exceeding 4 Sqm. |
| 2 | Supply and fixing 2nd class hard woodplain solid straight chowkats and frames,wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints all as specified and as directed by Engineer-in-charge. |
| 3 | Taking down shutters of any description exc 1.00 Sqm but not exc 2.00 Sqmeach including iron mongery & removing from site complete all as specified and directed |
| 4 | S& F 2ndclass hard wood factory made 30 mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, complete all as specified and directed. |
| 5 | S& F 30mm thick flush shutters, solid core construction with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed by Engineer-in-charge. |
| 6 | Dismantling boarding/ shelves any description, fixed in any position with screws complete all as specified and as directed. |
| 7 | M&L for 12 mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame as shelves in cupboardcomplete all as specified and as directed. |
| 8 | M&L for 12 mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on both faces; fixed with screws to timber frame work complete all as specified and as directed. |
| 9 | M&L forpreparation ofnew untreated wooden surfaces of any description, not otherwise describedover 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer -in-Charge. |
| 10 | S & F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staple complete all as specified and directed by Engr-in-Charge. |
| 11 | S & F Galvanised mild steel wire cloth as in repair, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staple complete all as specified and directed by Engr-in-Charge. |
| 12 | M&L for 4 mm thick Sheet glass, ordinary quality and glazing with oil putty or with wooden beading on wooden frame or steel frame or aluminium shutter area exc 0.5 sq. m in each pane complete all as specified and as directed. |
| 13 | M&L for 4 mm thick frosted glass, ordinary quality and glazing with oil putty or with wooden beading on wooden frame or steel framearean exc 0.5 sq. m in each pane complete all as specified and as directed. |
| 14 | Taking down chowkats or frames with shutters (w/o taking off shutters from the frames) area not exceeding 1.5 sqm each and removing from the site complete all as directed by Engineer-in-charge. |
| 15 | Supply and fixing powder coated anodised aluminium frame work as in partition wall, doors &, windows chowkhat with one or more rebates including joining beads cleat for fixing complete all as specified and directed. |
| 16 | S&F for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for shutters of doors, windows (openable/ sliding), ventilators with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary handle, hinges, bolts etc and filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per the directions of Engineer-in-Charge. |
| 17 | S & F Factory Made Solid PVC Door Frame of size 50 x 47 mm made out of 5.0 mm thick plain colour PVC Sheet reinforced with Mild Steel Square Tube, fixing in opening as per Specifications and Drawings shown in MES Schedule Part-II, as in repaircomplete all as specified and as directed. |
| 18 | S & F Factory Made Solid Panel PVC Door Shutter 30mm thick, consisting of frame made out of Mild Steel Tube of 19 Gauge thickness and size of 19mm x 19mm for Stiles and 15mm x 15mm for Top & Bottom Rails. Mild Steel Frame shall have a coat of Steel Primer of Approved Make Manufacturer. Mild Steel Frame shall be covered with 5.0mm thick heat moulded PVC \"C\" Channel of size 30 x 50mm forming Stiles and 5.0mm thick, 75mm wide PVC Sheets For Top Rail, Lock Rail & Bottom Rail on either side, and 10mm (5.0mm x 2) thick, 20mm wide Cross PVC Sheet as gap insert for Top Rail, Lock Rail & Bottom Rail. Panelling of 5.0mm thick PVC Sheet Beading on either side and joined together with Solvent Cement Adhesive, etc. An additional 5.0mm thick PVC Strip of 20mm width is to be stuck on the interior side of the \"C\" Channel using PVC Solvent Adhesive, fixing in opening as per Specifications and Drawings shown in MES Schedule Part-II, as in repair complete all as specified and as directed. |
| 19 | M&L for Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 20 | Supply & fixing 75 mm mild steel butt hinges (medium weight) cold rolled complete all as directed by Engineer-in-charge. |
| 21 | Supply & fixing 100 mm mild steel butt hinges (medium weight) cold rolled complete all as directed by Engineer-in-charge. |
| 22 | S&F 100 mm long extruded anodised aluminium alloy handles (fabricated type) ISI marked complete all as specified and directed by Engr-in-Charge. |
| 23 | S&F 150 mm long extruded anodised aluminium alloy handles (fabricated type) ISI marked complete all as specified and directed by Engr-in-Charge. |
| 24 | Supply & fixing 100 mm size aluminium anodised barrel tower bolts of extruded section (ISI marked) all as directed by Engineer-in-charge. |
| 25 | S&F 200 mm long aluminium anodised tower bolts extruded section, ISI marked (Make : Alans/Classic) complete all as specified and directed by Engr-in-Charge. |
| 26 | S&F 300 mm long aluminium anodised sliding bolt with hasp, staple (bolt type) and fixing clips or sheets cast of extruded section and fixing bolts and sliding bolts of extruded section ISI marked complete all as specified and directed by Engr-in-Charge. |
| 27 | Supply and fix 22-25mm dia SS pipe as in drapery rod including fixing brackets & decorative end brackets fixed with SS screw and rawal plug complete all as specified and directed. |
| 28 | Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc. complete. |
| 29 | M&L for Granite work 18-20 mm thick in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing to match with shade of granite complete all as specified and directed. |
| 30 | Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing tiles from site and rubbish off the premises complete all as directed by Engr-in-Charge. |
| 31 | Supply and fixvitrified ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile not exc 0.36 sqm in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles over and15 mm screed bed in CM(1:6) complete all as directed. |
| 32 | Supply and fix vitrified ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tilenot exc 0.36 sqm in as in skirting floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles over and10 mm rendering in CM (1:4) complete all as directed. |
| 33 | Supply and fix non skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.06 sqm but n exc 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles over and incl 15 mm screed bed in CM (1:6) complete all as directed. |
| 34 | Material and labour for glazed ceramic tile of area not less than 300 mm x 450 mm in vertical surfaces of wall and thickness not less than 7 mm, jointed with neat cement slurry and pointed in white/coloured cement to match the surface laid over and including 10mm thick screed in CM (1:4) complete all as specified and as directed by the Engr-in-Charge. |
| 35 | Taking down cement plaster in any description on brick or stone wall etc incl racking outjoints.hacking for key scrubbing down with water etc complete all as specified and directed. |
| 36 | M&L for 15 mm thick rendering in CM (1:6) on fair face of brick or concrete surfaces finishing even and smooth without using extra cement complete all as specified and as directed. |
| 37 | M&L for rendering 5 mm thick in CM 1:3 on ceilings finished even and smooth without using extra cement all as specified and directed. |
| 38 | M&L for preparing new plastered surfaces of ceiling and applying threeCoats of white wash complete all as specified and as directed. |
| 39 | M&L for preparing new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of chalk whitening over a coat of 3 mm wall care putty complete all as directed by Engr-in-charge. |
| 40 | M&Lforapplying one coat of white wash to old decorated (white washed) surfaces of ceiling including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss, efflorescent salts, trading oil and greasy spots) complete all as specified and directed by Engineer -in-Charge. |
| 41 | M&L for complete removal of existing treatment of old wall surface and applying two coats of oil bound distemper over a coat of chalk over a coat of 3 mm wall care putty whitening complete all as directed by Engr-in-charge. |
| 42 | Demolition and breaking up drain pipes internal dia 110/100 mm (PVC , Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and as directed. |
| 43 | Supply & fixPVC (SWR) Pipe 110 mm bore single/ double socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed. |
| 44 | Supply & fixPVC (SWR) Pipe 110 mm bore single/double socketed in any length with rubber ring joints laid in floor complete all as specified and as directed. |
| 45 | Supply & fixPVC (SWR) Pipe 75 mm bore single/ double socketed in any length with rubber ring joints laid in trenches/ floor complete all as specified and as directed. |
| 46 | Supply & fix inrepairs PVC (SWR) bends 110 mm bore any radius complete all as specified and as directed. |
| 47 | Supply & fix inrepairs PVC (SWR) bends with access door 110 mm bore any radius complete all as specified and as directed. |
| 48 | Supply & fix inrepairs PVC (SWR) junction single, (single T) with access door 110 mm bore equal or unequal complete all as specified and as directed. |
| 49 | Cutting into existing manholes for connecting new drains, making good to pipes and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate), finishedsmooth and reforming benching for 100mm bore pipe as required and as directed by the Engineer-in-Charge. |
| 50 | Taking up or down 15 mm bore galvanized iron pipe and connections, as directed by the Engineer-in-Charge. |
| 51 | Taking up or down 20 mm bore galvanized iron pipe and connections, as directed by the Engineer-in-Charge. |
| 52 | Taking up or down 25 mm bore galvanized iron pipe and connections, as directed by the Engineer-in-Charge. |
| 53 | Supplying and laying of 16 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 54 | Supplying and laying of 20 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 55 | Supplying and laying of 25 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 56 | Supply, hoisting and fixing in proper position ISI marked multi-layer rotational moulded polyethylene water storage tank (cylindrical vertical with closed top), of capacity 500 litresand providing necessary connections for connecting outlet pipe including dismantling old tanks all as specified and as directed by the Engineer-in-Charge. |
| 57 | M & L for cement concrete (1:3:6) type C-2 (40 mm graded aggregate) of 75 mm thick as in platform over roof for PVC tanks complete all as specified and as directed. |
| 58 | Supply and FixingPTMT (Poly Tetra Methylene Terepthalate) ball valves, high pressure, with epoxy coated aluminium rod and high density plastic ball, screwed for 20 mm bore pipe and fixed as directed by the Engineer-in-Charge. |
| 59 | Cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good in cement mortar 1:3, cutting not exc 10cm girth as specified and directed. |
| 60 | M & L for rendering 15mm thick cement plaster with cement sand mortar (1:3)on brick/ concrete surface over two coats of two component of cementitious and flexible acrylic coating of Tapecrete RTU / Piddifin 2k or equivalent over the clean and moist surface in opposite direction to form a seamless layer and make the surface water resistance coating as per manufacturer instruction as in sunken slab complete all as specified and as directed. |
| 61 | M & L for cleaning to concrete / plastered surfaces of sunken slab and applying water proofing treatment in the following courses:- ( a) Applying bitumen blown any grade, applied hot in two coats, to concrete surfaces at the rate of 1.5 kg per sqm. Per coat.(b) Supplying and laying polythene flim, black, 50 micron laid in floors incl provn of spout pipe of size of 40 mm dia and 600 mm long in desired position complete all as directed by the Engineer-in-Charge. |
| 62 | Demolition ofConcrete of any description and in anypositionnot otherwise specifically provided for complete all as specified and directed. |
| 63 | M & L for cement concrete (1:4:8) type D-2, using 40mm graded stone aggregate as in mass concrete sunken floor, surface finished even and fair without using extra cement complete all as specified andas directed |
| 64 | M&L for 40 mm thick P.C.C 1:2:4 type B1 using 20mm graded aggregate as in Sub-floor, sub base etc, finishing the surfaces of concrete (without using extra cement) even and rough to receive the topping layer complete all as directed. |
| 65 | Demolitiion of brick work or stone/ boulder, masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing and pre-cast concrete articles complete all as specified and as directed. |
| 66 | M & L for brick work using old size sub class \"B\" bricks straight or curved on plan exc 6 metre mean radius, built in cement mortar 1:6 all as specified and directed by Engr-in-Charge. |
| 67 | S&F in repairs vitreous china (white) wash down water closet pan (pedestal pattern) with \"P\" or \"S\" trap front or back inlet, fixing bolts(except flushing cistern and flush pipe) incl plastic water closet seat cover (white) and mild steel chromium plated or aluminium hinging device complete all as specified and directed by Engr-in-Charge. |
| 68 | S&F in repair White PVC Flushing Cistern 8 to 10 Litre capacity, Low Level Valve Less, Syphonic Action type with Inlet, Ball Valve, Float, flush pipe and Handleincluding Cutting and pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3 and fixed including taking down/out unserviceable Flushing Cistern and connected items complete all as specified and directed. |
| 69 | Supply and fix in repairs PVC connection pipe, comprising of 15 mm dia 450/600 mm long having PTMT nuts complete all as specified and directed. |
| 70 | Supply and fix, as in repair, 15 mm bore bib taps, chromium plated long neck cast copper alloy with crutch or butter fly handle, screwed down, including screwed for iron pipe or for brass ferrule complete all as specified. |
| 71 | S&F 15 mm bore CP two way bib cock with flange fancy type complete all as specified and as directed. |
| 72 | Supply and fixed in repair Pillar taps, cast copper alloy, with capstan heads,chromium plated,screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, including screwed to pipe/ brass ferrule complete al as specified and directed . |
| 73 | S&Fin repair Chromium plated brass Angle cock/ stop cock, fancy type, concealed type with wall flange fixed to 15mm bore of Iron pipe/ brass ferrule complete all as specified and directed. |
| 74 | S&F in repair various china white flat back wash hand basin of size 550mm x 400mm incl providing 32mm dia CP wasted coupling, brackets and making all necessary connections, fixed as directed by Engr-in-Charge. |
| 75 | M&L for fixing 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 76 | Supply & fix as in repairs, brass cromium plated over head shower roses125 mm size with or without swivel joint, including fixing to steel pipe or union all as specified and directed. |
| 77 | S&F CP bottle trap with internal portion 32mm size with 190mm long wall connection pipe complete all as specified and directed |
| 78 | M&L Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 79 | S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long as in repair complete all as specified and as diretced. |
| 80 | S&F vitrous china body soap dish, square/ round with chromium plated base complete all as specified and directed. |
| 81 | S&F in repairs, CP Tubular towel rail (premium quality), 20mm dia,600 mm long between flanges including brass chromium plated, complete all as specified and directed. |
| 82 | S&F Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and as directed. |
| 83 | M & L for 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as directed by Engineer - in - charge . |
| 84 | S&F in repairs stainless steel round grating 125 mm dia complete all as specified and directed by Engr-in-Charge. |
| 85 | S&F in repair for stainless steel plate rack for kitchen utensil made out of 0.50 mm thick stainless sheeet and over all size 600x750mm and 250 mm depth fixed to wall with screws complete all as specified and as directed. |
| 86 | M&L for laying Chequered cement concrete tiles 30cm x 30cm x (20 to 25)mm thick with grey cement and no pigment set, jointed and pointed in neat cement slurry in floors over & including 15 mm thick bedding layer of CM (1:6)complete all as specified and as directed. |
| 87 | M&L for 100 mm thick PCC 1:3:6 Type C-2 (using 40 mm graded stone aggregate) as in sub base for chequred tiles complete all as specified and as directed. |
| 88 | S&F in repair Stainless Steel Sink with Drainage Board l.0mm thick Overall size 915mm x 460mm and Bowl size 410 mm x 355mm x 165 mm for Kitchen or Laboratory with Plugs, Washers,Brass chromium plated Waste Fitting 32mm dia,PVC waste pipe, a Pair of Cast Iron Brackets duly Painted including Cutting and Pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3 including Taking down/out unserviceable Sink and connected Items, complete all as specified and as directed. |
| 89 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 90 | M&L for wiring with 1.5 Sqmm FR PVC insulated and sheathed multi stranded (FRLSH) flexible copper conductor cable inand incl rigid PVC conduit concealed / PVC surface conduit with sunk cast iron/ pressed steel terminal boxes ofadequate size with suitable thickness hylum laminated sheet , coverofadequate size for one light or one fancontrolledby one switch incl 1.5 Sqmm (FRLSH) PVC insulated andunsheathed multi stranded flexible copper conductor cable as earth wire(green colour) to common earth dolly complete all as specified and directed by Engr-in-charge. Note: a) Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc(b) On RCC roof ceiling PVC conduit shall be provided on surfaces for fan etc with proper fixing clips all as directed |
| 91 | All as per item No 90.00 here in before but for one 3 pin 5 Amp socket outlet on independent board. |
| 92 | All as per item No 90.00 here in before but for one 3 pin 5 Amp socket outlet on same board. |
| 93 | All as per item No 90.00 herein before butbell/ buzzers point controlled by one push button on the same board with other inner switches or independent with cable 1.5 sqmm size all as per specified and directed. |
| 94 | Point wiring all as per Ser item No. 90.00 here in before but with 2.5 sqmm FR PVC insulated and sheathed multi stranded (FRLSH) flexible copper conductor cable drawn in and including rigid PVC concealed conduit medium grade of suitable size with sunk cast iron/pressed steel terminal boxes of adequate size with suitable thickness plastic laminated sheet, cover for one 3 pin socket outlet 15 Amp on independent board including continuous 2.5 sqmm copper conductor cable (FRLSH) (multistranded) PVC insulated and unsheathed Cable as earth wire to common earth dolly, complete all as specified. |
| 95 | M&L for Bell, AC, 230 volts, 50HZ single pole ISI marked Complete |
| 96 | Supply and fixing of switch piano flush type 240 Volts 6 A, SP, one way with White in color complete all as specifed/directed. |
| 97 | M&L for Switch Bell push, flush type, 5 amp one way SI marked Cat pt No 14123 of anchor complete or its equivalent. |
| 98 | M&L for 6Amp, 2-In-1 Socket (IP 20) ISI marked catpt no 38320 of anchor or its equivalent |
| 99 | Supply and fixing of switch socket outlet combination 5 Pin,6 Amps, 240 volts flush type (non shuttered) with white in color complete all as specified/ directed. |
| 100 | Supply and fixing switch socket out let combination multipurpose 3 pin, 6/16 Amps and (with 3 pin 6 Amps outlet also) flush type (non shuttered) with white in color complete all as specified directed. |
| 101 | Material and labour for 100W electronic Fan Regulator with 5 step speed control ISI marked with white in color complete all as specified and directed by Engr-in-charge |
| 102 | Material and labour for ceiling rose surface bakelitetwo to three terminal isolated body fixed on PVC round block, 6A, Pilot 2 Plate with white in color complete all as specified and directed by Engr-in-charge |
| 103 | Supply and fixing LED fitting 1x16watts including 4 feet long Tube rod, 230 Volts, bipin holders connector block etc.complete with all accessories internally pre-wired and includingprovision of PVC round block 7.5cm dia and 2 cm in depth (2 Nos) for mounting the fittings and electrically connecting with three single core 23x0.0076 PVC insulated multistranded copper conductor flexible cable from ceiling rose to light fitting, complete all as specified and directed. |
| 104 | Supply and fixing LED fitting 1x10watts including 2 Feet long Tube rod, 230 Volts, bipin holders connector block etc.complete with all accessories internally pre-wired and includingprovision of PVC round block 7.5cm dia and 2 cm in depth (2 Nos) for mounting the fittings and electrically connecting with three single core 23x0.0076 PVC insulated multistranded copper conductor flexible cable from ceiling rose to light fitting, complete all as specified and directed. |
| 105 | Supply and fixingAesthetically designed wall bracket light with Brushed Nickel metallic body with glass outer cover with B22d electric bulb & E27 lamp holder from ceiling rose to light fitting complete all as specified and directed. Make : Havells/ Philips/Wipro |
| 106 | S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size. |
| 107 | Supply and fix of MCB SPN DB 8 way double door, glazed type, IP 43 protection,Glazed door, isolated neutral bar, insulated bus bar assembly,mechanical strength of IK09, complete all as specified and directed. |
| 108 | Supply and fix of MCB TPN DB 4 waydouble door,IP 43 protection,Glazed door, isolated neutral bar,insulated bus bar assembly,mechanical strength of IK09, complete all as specified and directed. |
| 109 | Supply and fix of MCB 100 Amps ,4Pole,16 KA, 415 volts completeall as specified and directed. |
| 110 | Supply & fix of MCBs single pole (SPN) 6 to 32 Amps with 10 KA breaking capacity of \"C\" Curve in distribution boards confirming to IS/IEC 60898-1 (ISI marked) complete all as specified and directed. |
| 111 | Supply & fix of MCBs single pole (SP) 6 to 32 Amps with 10 KA breaking capacity of \"C\" Curve in distribution boards confirming to IS/IEC 60898-1 (ISI merked) complete all as specified and directed. |
| 112 | M&L for Type 1+2 AC Surge Protection Device TP+N (4 Pole) 320 volt, 20-50KA, Protection against direct and indirect lightning surges, Maximum Discharge Current - Imax up to 100kA and Conforms to IEC 61643-11 all as directed by Engr-in-Charge. |
| 113 | S&F in Replacement of existing sub main wiring with two run of single core (FRLS) PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area6.0 Sqmm drawing into and including PVC non metallic rigid conduit of adequate size and making electric connections including one run (FRLS) PVC insulated single core copper conductor cable 6.0 Sqmm as a earth continuity conductor (green colour) in and including in non metallic rigid PVC conduit, including cutting chases in brick wall, replastering and making good to match the existing specifications complete all as specified and directed by Engineer-in-Charge. Note : (i)Rates are deemed to be included cutting chases of conduit and sinking for boxes cutting and making holes in wall/ floor for passing in or through conduit (ii)Two run of6.00 sqmm single core (FRLS) PVC insulated copper conductor cable one run of 6.0 sqmm copper conductor cable (FRLS)as a earth lead and one run of PVC conduit of suitable size will be measured as a one unit. |
| 114 | Material & labour for Sub main wiring with two runs of single core 1.5 Sqmm (Nominal Area) FRLS PVC insulated and unsheathed multi standed copper conductor cable LT 1100 volts grade drawn thorugh into PVC non metallic rigid conduit concealeed including PVC insulatedstranded copper conductor nominal cross section area as under as contineous earth continuity wirecomplete all as specified.Two run of 1.5 Sqmm cable one run of 1.5 Sqmm earth continuity wire for connection to DBs/dolly shall be deemed to be included in this item and shall be measured as one run complete all as specified and directed. |
| 115 | M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanizediron or steel all as shown in electrical plate No.5 of SSR Part-I (2009) including filling of charcoal dust , common salt all around Earth plate upto 150mm, 20mm bore GI medium grade watering pipe, 15 mm bore light grade earth lead protection pipe upto main board, funnel with wiremesh, 40mm thickRCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate reinforced withsuitable handle and angle iron frameand necessary excavation and earth work in any type of soil etc. complete all asspecifiedand as directed includingtesting on completion. Note : The rate quoted include cost of min 7.5 metre earthing lead. |
| 116 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. |
| 117 | S&F 15 mm bore Gun-metal, globe or gate valves (ISI marked), with iron wheel head, screwed both ends for iron pipe and fixed all as specified and directed by Engr-in -Charge. |
| 118 | M&L galvanised steel water tubing medium grade of 15 mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by Engr-in-Charge. |
| 119 | Supply and fix Bib taps 15 mm, cast copper alloy with crutch orbutterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 120 | M&L Hot water pipe (ISI Marked) duly insulated with glass wool and aluminium cladding 15 mm bore. |
| 121 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep in suitable size of hole with blades and frame and louvers. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail