| 1 | Taking up / downwater heater (Geyser) of capacity 50/35/25 ltrs operating on 230 volts AC electric supply, in any position and of any make, after disconnecting all electric connection and hot and cold water connection,and including transportation to the contractor\"s workshop for repair and vice-versa after repairing, general cleaning/overhauling, cleaning and discaling the tank and assembly with suitable detergent and making fully serviceable and fixing back in same location / position or new location complete all as specified and as directed. Note :- (a) Repairing of any parts except the work mentioned in item will be measured and paid seperately under supply only items. (b) Replacement of any un serviceable parts required for making the geyser serviceable will be measured and paid seperatelly under\"supply only\"No extra payment will be allowed for replacing these items, as the same is deemed to be included in relevant item. |
| 2 | Supply only Stainless steel inner tank suitable for 25 ltrs Geyser of any make / shape /holes for fixing geyser assembly. |
| 3 | All as per item No 2 herein before but for 35 ltrs. |
| 4 | All as per item No 2 herein before but for 50 ltrs. |
| 5 | Supply only bottom base assembly of copper 9/8/7/6 holes type suitable for 35/25 ltrs capacity geyser complete all as specified and directed. |
| 6 | All as per item No 5 here-in- before but for 50 ltrs capacity geyser . |
| 7 | Supply heating element 1500/2000 watts capacity of any shape /type with rubber gasket . |
| 8 | Supply Thermostat suitable to adjust the temperature from0º C to 80º C all as directed. |
| 9 | Supply only glass wool ofgood quality as approved by Engr-in-Charge. |
| 10 | Supply only neon indicator lamp of any shape / size / colour all asdirected. |
| 11 | Supply only PVC insulated sheathed 3 core flexible copper conductor cable of size2.5Sqmm all as directed. |
| 12 | Supply only Safety plug any type. |
| 13 | Supply only non return valve 15mm bore cast copper alloy suitable for geyser complete all as specified and as directed. |
| 14 | Supply only rubber gasket of thickness 5mm for geyser assy of08/09 holes complete all as specified and as directed. |
| 15 | Supply onlybottom inspection cover plate in two pieces with suitable openings for indicator lamps, power cable entry with rubber washer etc, gauge of plate not less than 18 SWG for 25/35/50 Ltrs capacity geysers of any make/ shape complete all as specified and as directed. |
| 16 | Supply only GI nut bolts and washers (not exceeding the size 150 mm x 12mm) of existing size of geyser spare parts complete all as specified and as directed. |
| 17 | Supply only outer MS shell complete including top and bottom suitable for 25/35/50 Ltrs capacity geyser of any make, shape & size as per existing but gauge of sheet not less than 22 SWG complete all as specified and as directed. |
| 18 | Supply and fix in repair 16A ,30mA, PRCD power plug,220 V to provide safety against electric shocks with built in test and reset button complete all as specified and as directed. |
| 19 | Supply and fixing PVC connection 15mm bore 450mm longin any position with both end brass nut with inner thereading and washer suitable for cold water connection complete all as specified and as directed. |
| 20 | Supply and fixing CP connection 15mm bore 450mm longin any position with both end brass nut with inner thereading and washer suitable for cold water connection complete all as specified and as directed. |
| 21 | Material and Labour for spray painting of geyser outer body of any make / size by applying one coat of synthetic enamel white paint over the existing paintincluding cleaning and preparation of surface, complete all as specified and as directed. |
| 22 | Disconnecting of water connection and dismantling complete solar water heating system of capacity 1000 ltrs per day including hot & cold water pipes and hot water tank complete and refixing after repairing the system fixing back in position and testing complete all as specified and directed.Note : Rates quoted by the contractor shall deemed to be included for :-(a) Making good the worn out missing nuts bolts, washers, union, sockets, flanges and screws etc.(b) Descaling/ desludging, cleaning and washing of the hot water pipes, copper tubes, hot and cold water tanks by using appropriate chemicals and re-assembling the panel including welding of collector fins as required.(c) Painting of staging, solar panel frame, hot water tank frame with applying one coat of synthetic enamel paint incl preparation of old painted steel surfaces of any description(d) All other materials shall be measured and paid separately under respective items. |
| 23 | All as per items No 22 here in before but of capacity 500 ltrs per day complete all as specified and directed. |
| 24 | All as per items No 22 here in before but of capacity 200 ltrs per day complete all as specified and directed. |
| 25 | Supply only solar energy collector panel made of aluminium body with toughened glass complete with copper fins of capacity upto 1000 ltrs per day complete all as specified and directed. |
| 26 | Supply only as in replacement, solar panel toughened glass having thickness 5mm all as per the existing model of system complete all as specified and directed. |
| 27 | Supply only as in replacement, solar panel neoprene gasket to make system air tight, dust and water proof complete all as specified and directed. |
| 28 | Supply only as in replacement, copper tubes with collectors fins for solar energy collector panel complete of same dia and thickness as per existing, brazing by copper alloy brazing rod with the existing inlet/outlet hot/cold water pipes to make the panel water tight complete all as specified. |
| 29 | Supply only solar energy collector panel manifold 1.40 mtr long, made of 20mm dia copper tube having 1 No MS flange 74 mm dia welded at each end duly drilled for nuts & bolts complete all as specified and directed by Engineer-in-charge.Note : Rate quoted deemed to be included for welding of solar collector tubes with manifold all as directed by Engineer-in-charge and as recommended by manufacturer. |
| 30 | Supply only hot water storage tank of food grade stainless steel upto 1000 ltr capacity with heat exchanger having thermic fluid / Anti - freeze solution complete all as specified and directed. |
| 31 | Supply only auxillary tank for make up tank to reduce pressure of solar system complete all as specified and as directed. Note for item no 25 to 31: Cost of fixing charges for item no 25 to 31 are included in item no.22 to 24 respectively. |
| 32 | Supply and Fix in repair hose pipe for hot/ cold water for solar system of suitable length as existing size complete with 02 Nos clamps complete all as specified and directed. |
| 33 | Supply and Fix in repair Electrical back heater of 3 KW for solar system with all electrical connection complete all as specified and as directed. |
| 34 | Material and Labour for insulation of hot water pipe with glass wool and covering with aluminium sheet cladding 25 gauge for 20mm bore GI pipe including taking down old complete all as specified and directed. |
| 35 | Supply & Fix rotational moulded polythene water storage tanks in repair, white colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I of capacity 500 Litres all as specified and directed . |
| 36 | Supply and Fix in repair ball brass valve 20mm bore dia high pressure with polythene float and fly nuts complete screwed with iron pipe and fixed all as specified and directed. |
| 37 | Supply and Fix in repairs gunmetal globe or gate valve with iron wheel head, screwed both ends for iron pipes 20mm bore as in repairs complete all as specified and directed. |
| 38 | Supply and Fix in repairs hot water pipe glass wool insulation with aluminium sheet 26 gauge cladding for 20 mm bore pipe medium grade all as specified and directed. |
| 39 | Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH. Note : Old meter shall be deposited in MES Store. |
| 40 | Material and labour for earthing in repair complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level), with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, earth lead GI wire 4 mm dia by means of bolts, nuts, check-nuts and washers of galvanized iron and of earth wire protected by galvanizediron pipe light grade 15mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh complete including excavation and earth work, PCC chamber and cover in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregatein lieu of CI cover and frame etc allas specified and shown in electrical plate No. 3 of SSR-2009 (Part-I), testing on completion, complete including dismantling of existing earthing all as specified and directed.Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:3:6) type C-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.(ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit.(iii) Rate shall include GI strip and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately.. |
| 41 | Material and Labour for Chemical Earthing in repair with copper pipe electrode 3.0 M long having outer pipe dia 80mm & inner pipe dia 50mm duly filled with highly conductive and anti corrosive compound of required quantity having chemical compostion Bentonite 40%, copper sulphate 20%, Gypsom 5%, Graphite 10%, Alum 5%, Zinc sulphate 10%, Aluminium sulphate 10% buried in ground by digging a bore of 150mm dia surrounded by soil friendly backfill compound non soluble in water including connection with Copper earth strip 32x6mm upto 7 meter length, making PCC pit of size 0.3mx0.3mx0.3m (inner size) in PCC 1:3:6 type C-1 with 40 mm thick cover in RCC 1:2:4 type B-1 reinforced with 6mm dia MS bars 3 Nos both ways with lifting hook made out of 8mm dia bar and testing on completion to acheivevalue not more than 1 ohm complete all as specified and directed. |
| 42 | Material and Labour for taking down old aluminum/copper /GI strip of any size including porcelin insulator for complete all as specified and directed. |
| 43 | Material and Labour for taking down old air termination rod,GI pipe includng PCC foundation complete all as specified and directed. |
| 44 | S&F in replacement for GI strip 25x4mm as in eath continiouty conductorall as specified and directed. |
| 45 | S&F in replacement for alluminum strip 25x3mm as in earth continiouty conductorall as specified and directed. |
| 46 | S&F in replacement for copper strip 20x3 mm as in earth continiouty conductor complete all as specified and directed. |
| 47 | S&F in replacement for test point made out of GI strip 50x6mm,200mm long-02 nos and 12mm dia GI nut bolts 40mm long - 03 nos complete all as specified and directed. |
| 48 | S&F in replacement test point made out of Copper strip 32x6mm,200mm long brass nut bolts-02 nos and 12mm dia GI nut bolts40mm long - 03 nos complete all as specified and directed. |
| 49 | S&F in replacement Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed. |
| 50 | Material and Labour for PCC 1:3:6 Type C-I using 20mm graded agrgate for PCC of size 0.3x0.3x0.25 cube with for mounting GI pipe 40mm dia complete all as specified and directed. |
| 51 | M&L in repair for Sub Main Wiring (in replacement) with two single core 2.5 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in and including PVC conduit of suitable size with and including one run of continuous multi stranded copper conductor 2.5 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 2.5 Sqmm main cable + one run of 2.5 Sqmm cable for earth continuity and PVC conduit shall be measured as one unit/one Running Metre. |
| 52 | All as per Srl item No 51here-in-before but 3 x 4sqmm. |
| 53 | All as per Srl item No 51here-in-before but 3 x 6sqmm. |
| 54 | All as per Srl item No 51here-in-before but 3 x 10sqmm. |
| 55 | M&L for dismantling of Ceiling Fan/ Exhaust Fan of any make/ model/ sweep for cleaning/ repair and refixing the same after repair complete all as specified and directed. |
| 56 | M & L for cutting and removing the old defective/ burnt winding, cleaning the core of ceiling fan motor of sweep size upto 1500mm, rewinding fan motor with super enamelled copper winding wire of same gauge with insulating material, varnishing the core assembly, drying up the moisture content, re-assemble the same after spray painting to existing color complete all as specified and as directed. |
| 57 | All as per above item No 56 but for exhaust fan upto 600mm sweep size with frame. |
| 58 | S&F in replacement ball bearing ISI marked suitable for any type/ size/ make of Celing fan/ Exhaust Fan complete all as directed. |
| 59 | S&F in replacement capacitor 2.5/ 3.15/ 4 MFD complete all as specified and directed. |
| 60 | S&F in replacement of single phase highly efficient heavy duty motor with pressure die cast aluminium rotor, 90w, 230V confirming suitable IS code for exhaust fan of sweep size upto 300mm complete all as specified and as directed. Note : if any additional metal strip required to fix the motor in exhaust fan, cost of strip and any other items/work required for proper functioning of exhaust fan is included in the quoted rate. |
| 61 | All as per above item No 60, single phase, 166w, 230V for exhaust fan upto 380mm sweep. |
| 62 | All as per above item No 60, single phase, 410w, 230V for exhaust fan upto 450mm sweep. |
| 63 | All as per above item No 60, single phase, 850w, 230V for exhaust fan upto 600mm sweep. |
| 64 | S&F in replacement of aerodynamically contoured blades which handle maximum air with minimum power consumption confirming suitable IS code for exhaust fan of sweep size upto 300mm complete all as specified and as directed.Note : Cost of items/work required for proper functioning of exhaust fan is included in the quoted rate. |
| 65 | All as per above item No 64 but for exhaust fan upto 380mm sweep. |
| 66 | All as per above item No 64 but for exhaust fan upto 450mm sweep. |
| 67 | All as per above item No 64 but for exhaust fan upto 600mm sweep. |
| 68 | S&F in replacement of rigid metalic frame with rubber mountings with suitable nut bolts or hole fastner for silent operation confirming suitable IS code for exhaust fan of sweep size upto 300mm complete all as specified and as directed. Note : Cost of items/work required for proper functioning of exhaust fan is included in the quoted rate. |
| 69 | All as per above item No 68 but for exhaust fan upto 380mm sweep. |
| 70 | All as per above item No 68 but for exhaust fan upto 450mm sweep. |
| 71 | All as per above item No 68 but for exhaust fan upto 600mm sweep. |
| 72 | S&F in replacement sturdy steel bird guard with rust free feature confirming suitable IS code for exhaust fan of sweep size upto 600 mm complete all as specified and as directed. Note : Cost of T&P and other items/work required for fixing the bird gaurd of exhaust fan is included in the quoted rate. |
| 73 | S&F in replacement aluminium powder coated louver suitable for exhaust fan of sweep size upto 300 mm complete all as specified and as directed. |
| 74 | All as per above item No 73 but for exhaust fan upto 380mm sweep. |
| 75 | All as per above item No 73 but for exhaust fan 400 to 450mm sweep. |
| 76 | Taking down carefully with battens/ PVC surface/ concealed conduit unserviceable copper/ aluminium point wiring (light, fan, socket) complete including fittings such as switches, ceiling roses, pendants, socket etc. and removing unserviceable material from site and making good disturbed surfaces of walls, floors etc. complete all as specified and directed. |
| 77 | M&L for point wiring surface type with 3 x 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLSH copper conductor cable (phase, neutral & earth wire), earth wire shall be connected to common earth and earth duly with suitable copper lugs drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with all PVC conduit accessories, 1.60 mm thick GI metal flush box or surface mounting plastic/ PVC boxes suitable for modular/ conventional switches/ sockets/ fan regulators with cover plates (modular/ conventional type as required), blanking plates, brass screws, cup washers, gypsum screws and connected items including all cutting/ chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and as directed for the followings. |
| 78 | One light point controlled by one switch. |
| 79 | One ceiling/exhaust/wall fan point controlled by one switch. |
| 80 | One socket outlet 5 amps point on the same board with other switches. |
| 81 | One socket outlet 5 Amps point controlled by one switch on independent board. |
| 82 | All as per serial item No 77 above but with 3 x 2.5 Sqmm nominal cross sectional area copper conductor cable for one 16 Amps socket outlet point on independent board. |
| 83 | All as per srl item No 77 but point wiring with size of cable 4 sqmm for industrial socket outlet 3 pin 16 / 20 Amps point complete all as specified and as directed. |
| 84 | All as per item No.77 here-in-before butpoint wiring for one bell point controlled by one single pole, one way bell push complete all as specified and as directed. |
| 85 | S&F in repair switch piano, flush type, single pole, one way, 5 Amp, 230volts complete all as specified and as directed. |
| 86 | S&F in repair switch Bell push, flush type, single pole, one way, 230 voltscomplete all as specified and as directed. |
| 87 | S&F in repair switch piano, flush type, single pole, one way, 15 Amp 230 volts complete all as specified and as directed. |
| 88 | S&F in repair socket outlet 2 in 1, 3 pin, 6Acomplete all as specified and as directed. |
| 89 | S&F in repair socket outlet multipurpose 3 pin 5 Amp & 15 Amp, flush type, complete all as specified and as directed. |
| 90 | S&F in repair ceiling rose, three terminals, PVC/ isolated body, complete all as specified and as directed. |
| 91 | S&F in repair Call bell, electric Ding - Dong type, 230 volt, single pole, complete all as specified and as directed. |
| 92 | S&F electronic dimmers or fan regulator, 450W, 250V flush type on the exiting phenolic laminated sheet etc. as reqd.complete all as specified and as directed. |
| 93 | S&F in repair wall mountedLED batten 20 watt with epoxy powder coated , 3000k to 6500k, radiation free, mercury free, glare-free efficient light distribution, white coloured ABS end caps, electronic driver, 140-270 Volt, THD<10%,mounting into the wall/ ceiling by SS clips with all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 94 | All as per Srl item No 89here-in-before butLED batten 10 watt. |
| 95 | S&F in repair LED min 10 watts bollard garden light fitting with robust design and efficient light distribution including light fitting fixing and making PCC block foundationand connecting the fittinngs on PCC foundation blockincluding taking out old complete all as specified and as directed. |
| 96 | S&F in repair LED 30 W, IP65,Aluminium body, 3000lm,input voltage 140-270v, cri>80 suitable as building security light complete all as specified and as directed. |
| 97 | S&F in repair decorative indirect post top for garden & landscape lighting of min 25 watts with IP 65 protection with allconnected accessories, anticorrosion, antiglare and uniform distribution complete all as specified and as directed. |
| 98 | S&F in repair sheet metal enclosure single pole and neutral with a two pin socket and earth plug complete with one MCB single pole and 240V, 20 Amp ‘B’ curve, 10 kA, complete all as specified and directed . |
| 99 | S&F in repair single phase & neutral, double door 8 way, 240 volt with 200 Amps rated bus bar & IP 54 protection, including taking out old unserviceable complete all as specified and directed. |
| 100 | S&F in repair TPN DB, double door,4 way, 415 volt with 200 Amps rated bus bar & IP 54 protection, complete all as specified and directed. |
| 101 | All as per item No 96 here-in-before butTPN DB 8 way complete all as specified and as directed. |
| 102 | S&F in repair Load line TPN vertical distribution board 8 Way double door dust protected powder coated inclusive of busbar, neutral link, blanking plates and having provision of MCCB 4 Pole 100 to 120 Amps as incomer and MCBs SP/TP as outgoing as per IS - 01 No,having IP-43 protection, complete all as specified and directed. |
| 103 | S&F in repair Load line TPN vertical distribution board 4 Way double door dust protected powder coated inclusive of busbar, neutral link, blanking plates and having provision of MCCB 4 Pole 100 to 120 Amps as incomer and MCBs SP/TP as outgoing as per IS - 01 No,having IP-43 protection, complete all as specified and directed. |
| 104 | S&F in repairs MCCB, 4-pole, breaking capacity 16 KA, 415 volts, 125 Amps including taking down unservicable one complete all as specified and as directed. |
| 105 | S&F in repair MCCB, 4P, breaking capacity 16 KA, 415 volts, 63 Amps complete all as specified and as directed. |
| 106 | S&F in repairs TPN 100A, 10 KA, 415 volts, including taking down unservicable one complete all as specified and as directed. |
| 107 | S&F in repair TPN 63A , breaking capacity 10 KA, \"B\" curve, complete all as specified and as directed. |
| 108 | S&F in repair MCB 40 Amp, 415 Volt, TP, 10 KA, \"B\" curve, complete all as specified and directed. |
| 109 | S&F in repair MCB 32/ 40 Amp, 230 Volt, SPN, 10 KA, \"B\" curve, complete all as specified and as directed. |
| 110 | S&F in repair MCB 6 to 32 Amp, 230 Volt, SP, 10 KA, \"B\" curve,complete all as specified and as directed. |
| 111 | S&F in repair Plug top, 3 pin, 6 Amps, 230 volt complete all as specified and directed. |
| 112 | All as per srl item no 107 but 16 amp. |
| 113 | Supply and fix GI pipe light grade 40mm dia with all fittings and fixed complete to walls and ceiling complete all as specified and as directed |
| 114 | Supply and fix epoxy based insulator of suitable size 40mm height for fixingGI/ Al earth strip on wall / ceiling / floor / poles etc complete all as specified and as directed. |
| 115 | Note: The total amount shall subject to adjustment of credit of Rs 61549.40 for old Materials as per Schedule of Credit |