| 1 | Excavation in post holes (or similar holes) each n exc 0.5cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers n exc 25cm ,in watering and removing surplus soil to a distance n exe 50m and making good surface in soft /loose soil all as specified and directed. |
| 2 | M&L for Cement concrete type D-2 (1:4:8) using 40mm graded stone aggregate asin foundations,filling and mass concrete |
| 3 | M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240complete all as specified and as directed. |
| 4 | Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walk ways; railings; framework of water tanksand similar work conforming to Fe.290.Gde-E-165. |
| 5 | S&F for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts,if required: hooks (stay),heavy,for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securingpurlinstowood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 . |
| 6 | Supply and fix Polycarbonate sheet coloured 4mm thcik solid sheet half round of appropriate size including neccesary drilling,, etc fixed with self taping screwscomplete all as specified and as directed. |
| 7 | S&F PVC(SWR) 150mm dia half round Rain water gutter incl all joints etc complete all as specified and as directed. |
| 8 | Supply and fix Aluminium Wind tie (Flat) with 50mm x6mm thck including necessary cutting, drilling and fabrication etc including fixed with self-tapping screws on new CGI/Polycarbonate roofing etc complete all as specified and as directed. |
| 9 | M & L for PCC 1:3:6 type C-1 using 20mm graded stone aggragate in lintels upto 1.5m clean span cills,steps; seismic and other similar bands,plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as directed. |
| 10 | Material and labour for two coat Synthetic Enamelpaint surfaces of any description over 10 cm in width or girth, not otherwise described on steel surface over one coat of red oxide primer including preparation of new or old steel surface complete all as specified and directed. |
| 11 | Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) (unreinforced) of any description and in any postion not otherwise spcifically provided etc and removing debris off the site complete all as specified and as directed. |
| 12 | M&L 75mm thick PCC 1:4:8 type D2 (40 mm graded aggregate) as in Sub base floor finished even and rough to receive the top layer complete all as specified and as directed. |
| 13 | M&L for chequered cement concrete tiles 20 cmx 20 cmx 25 mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigments of required colour laid over and including 20mm thick screed bed in cement mortar (1;6) all as specified and as directed. |
| 14 | S & F PVC (SWR) bends any radius 110 mm bore provided with acess door complete as specified. |
| 15 | Taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and as directed. |
| 16 | M&L for 15 mm thick rendering in cement mortar 1:6on brick work or block masonry surfaces of wall, finished even and smooth with out using extra cement complete all as specified and as directed. |
| 17 | M&L Preparing newly plastered surfaces of external walls and applying exterior wall putty of 1mm thick for smoothness, one coat of exterior wall primer and two coats of Exterior Emulsion anti fungal weather proof paint APEX ULTIMA OF Asian Paint or WEATHER COAT SMOOTHof Berger or equivalentcomplete all as per manufacturer instruction as directed. |
| 18 | S&F110 mm bore PVC (SWR) pipessingle socketed in any length with rubber ring joints fixed to pipes/ walls/trenches complete all as specified and as directed. |
| 19 | Excavation in post holes (or similar holes) each n exc 0.5cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers n exc 25cm ,in watering and removing surplus soil to a distance n exe 50m and making good surface in hard/dense soil all as specified and directed. |
| 20 | M&L for Cement concrete type C-2 (1:3:6) using 40mm graded stone aggregate asin foundations,filling and mass concrete complete all as specified and as directed. |
| 21 | M&L for Rolled sections as in main and cross beams, hip and jack rafters;purlins where connected to common rafters and running rails and guides for sliding doors;fixed with angle cleats or other connecting plates conforming to Fe-410-W(Gde-E-250) quality B complete all as specified and as directed. |
| 22 | S&F prepainted Galvalume Aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strenth of 550MPA as in roof covering /cladding to wall,crimp curved where necessary fixed with self tapping screws complete all as specified and as directed. |
| 23 | Surface excavation n exc 30 cm deep and avg 15 cm deep and getting out in hard/dense soil etc complete. |
| 24 | M&L for Hard core, of gauge n exc 63 mm deposited, spread and levelled in layers n.exc. 15 cm thick , watered and rammed to a surface complete all as specified and as directed. |
| 25 | M& L for 100 mm thick PCC type C-2(1:3:6)using 40mm graded stone aggregate as in pavings,hard standing etc including finishthe surface even and rough to receive the top finish complete all as diercted. |
| 26 | M& L for 50 mm thick Cementconcrete type B-1, 1:2:4 (20mm gradedaggregate)as in pavings,hard standing etc including finish the surface even and rough finish complete all as diercted |
| 27 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point all as directed. |
| 28 | Excavating in trenches, n.exc 1.5m wide and n exc 1.5m in depth; for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out hard/dense soil complete all as specified. |
| 29 | M&L for precast solid block exceeding 10 cms in width 1:3:6 type C1 (using 20mm graded aggregate) and set in cement mortar 1:6 all as specified and as directed. |
| 30 | M&L forSand filling under floors or in foundations including wateringand consolidation complete all as specified and as directed. |
| 31 | M&L for preparation of newplastered surfaces of walls applying two coats of distemper, oil emulsion including alkali resistant primer complete all as specified and directed. |