| 1 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/ Steel pole, laying of cable in trenches etc and getting out in hard / dense soil complete all as specified and directed. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed. |
| 3 | Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 4 | Supply and laying in trenches of 90 mm outer dia and 76 mm inner dia DWC HDPE pipe, Heavy duty, conforming to IS 14930 Part 2, made of HDPE, with corrugated outer wall and smooth inner bore, suitable for passing LT UG XLPE cable, including cost of couplers, jointing accessories, end caps and laying as per site requirement and Engineer-in-charge direction. Make SFMC, Reliance, Supreme |
| 5 | M&L in replacement of old unsv XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area laid in trenches / duct or fixed to wall / passing through pipe on pole with suitable size cable glands, crimping type cable lugs for stranded aluminium conductor of following sizes complete all as specified and directed :- |
| 6 | (a) 4 Core X 16 Sqmm |
| 7 | (b) 3.5 Core X 35 Sqmm |
| 8 | Supply & lay Galvanised Steel tubing 25 mm bore, light grade in protection of cable at road crossing/ hard standing/ pole protection fixed with MS clamps, nut bolts and washer as per site requirement including taking down old unserviceable pipes complete all as specified and directed. |
| 9 | M&L cutting of road/ hard standing up to a size not exceeding 20 cm in width and not exceeding 60 cm in depth for laying of LT UG cable/ protection pipe line making good the disturbed portion so as to match existing finishing with PCC 1:2:4 type B1/ cement mortar in CM (1:2) complete all as specified and directed. |
| 10 | Supply, fabrication, and laying of ERW mild steel pipe 200 mm nominal bore, confirming to IS 3589 / IS 1239 (Heavy Class), wall thickness not less than 6.3 mm, with both ends flanged, including welding of flanges, drilling of holes, fixing with nuts, bolts, gaskets of suitable thickness, applying one coat of red oxide primer and two coats of synthetic enamel paint (post-installation), laying in trenches or on wall/ clamps/ supports as required, complete all as specified and directed.Make TATA, APL Apollo Tubes Ltd., SAIL |
| 11 | Supply, fabrication, and laying of ERW mild steel pipe 150 mm nominal bore, confirming to IS 3589 / IS 1239 (Heavy Class), wall thickness not less than 6.3 mm, with both ends flanged, including welding of flanges, drilling of holes, fixing with nuts, bolts, gaskets of suitable thickness, applying one coat of red oxide primer and two coats of synthetic enamel paint (post-installation), laying in trenches or on wall/ clamps/ supports as required, complete all as specified and directed. Make TATA, APL Apollo Tubes Ltd., SAIL |
| 12 | Supply, fabrication, and laying of ERW mild steel pipe 100 mm nominal bore, confirming to IS 3589 / IS 1239 (Heavy Class), wall thickness not less than 6.3 mm, with both ends flanged, including welding of flanges, drilling of holes, fixing with nuts, bolts, gaskets of suitable thickness, applying one coat of red oxide primer and two coats of synthetic enamel paint (post-installation), laying in trenches or on wall/ clamps/ supports as required, complete all as specified and directed. Make TATA, APL Apollo Tubes Ltd., SAIL |
| 13 | Supply, fabrication, and laying of ERW mild steel pipe 80 mm nominal bore, confirming to IS 3589 / IS 1239 (Heavy Class), wall thickness not less than 6.3 mm, with both ends flanged, including welding of flanges, drilling of holes, fixing with nuts, bolts, gaskets of suitable thickness, applying one coat of red oxide primer and two coats of synthetic enamel paint (post-installation), laying in trenches or on wall/ clamps/ supports as required, complete all as specified and directed. Make TATA, APL Apollo Tubes Ltd., SAIL |
| 14 | Supply, fabrication, and laying of ERW mild steel pipe 63 mm nominal bore, confirming to IS 3589 / IS 1239 (Heavy Class), wall thickness not less than 6.3 mm, with both ends flanged, including welding of flanges, drilling of holes, fixing with nuts, bolts, gaskets of suitable thickness, applying one coat of red oxide primer and two coats of synthetic enamel paint (post-installation), laying in trenches or on wall/ clamps/ supports as required, complete all as specified and directed. Make TATA, APL Apollo Tubes Ltd., SAIL |
| 15 | Supply, fabrication, and laying of ERW mild steel pipe 32 mm nominal bore, confirming to IS 3589 / IS 1239 (Heavy Class), wall thickness not less than 6.3 mm, with both ends flanged, including welding of flanges, drilling of holes, fixing with nuts, bolts, gaskets of suitable thickness, applying one coat of red oxide primer and two coats of synthetic enamel paint (post-installation), laying in trenches or on wall/ clamps/ supports as required, complete all as specified and directed. Make TATA, APL Apollo Tubes Ltd., SAIL |
| 16 | Supply, installation, testing and commissioning of water monitor with 80 mm NB flanged inlet, fixed type, manually operated, having horizontal rotation of 360° and vertical movement of minimum 30° to 70°, suitable for discharge of not less than 1750–2000 LPM at 7 kg/ cm² pressure (70 m head), jet/ fog nozzle with flow selector, constructed in gunmetal / stainless steel / hard anodized aluminium alloy, complete with flanged base, coupling hardware, gaskets, fasteners, duly tested at manufacturer’s works and site, including all arrangements for anchoring on pedestal or base plate, complete all as specified and directed by the Engineer-in-Charge. Note: Civil works required for fixing the fire water monitor, including foundation preparation such as excavation, PCC, RCC pedestal with reinforcement, embedded anchor bolts, formwork, curing, plastering, and finishing, shall be deemed to be included in the quoted rate. The entire civil work shall be executed in accordance with the installation guidelines of the monitor manufacturer and to the satisfaction of the Engineer-in-Charge. |
| 17 | Supplying & Fixing of 100 mm dia Non-Return Valve (NRV), flap type, cast iron, flanged ends, rubber seated flap, suitable for horizontal installation in fire water supply pipeline, conforming to PN 16 pressure rating, complete with matching flange set, nut bolts, washers, gaskets, and jointing materials. Valve shall conform to relevant IS specifications complete all as specified and directed by Engineer-in-Charge. |
| 18 | Supplying & Fixing of 80 mm dia Non-Return Valve (NRV), flap type, cast iron, flanged ends, rubber-seated flap, suitable for horizontal installation in fire water supply pipeline, conforming to PN 16 pressure rating, complete with matching flange set, nut bolts, washers, gaskets, and jointing materials. Valve shall conform to relevant IS specifications complete all as specified and directed by Engineer-in-Charge. |
| 19 | Supplying & fixing, testing and commissioning of 80 mm dia Butterfly Valve, suitable for water supply/ fire hydrant system, having cast iron (CI), stainless steel (SS) disc with gunmetal seat and stainless steel shaft, rated for PN 1.6 (16 bar) working pressure, lever-operated, with flanged ends and confirming to IS:13095 and relevant ISI standards. The valve shall be supplied complete with matching nuts, bolts, washers, gaskets, and jointing material, suitable for horizontal/ vertical installation in pipeline. Valve shall be factory-tested and ISI-marked, and suitable for manual isolation in pressurized water systems. |
| 20 | S&F of 100 mm dia Foot Valve, ball type, heavy-duty design, with cast iron body, SS ball, gunmetal seat, and corrosion-resistant stainless steel strainer, suitable for vertical mounting at pump suction in fire fighting supply system. Valve shall be flanged type, pressure rated PN 1.6, and designed for continuous water duty with minimal head loss. The item includes all accessories such as matching nut bolts, washers, gaskets, and jointing material, suitable for raw/ clear water application. |
| 21 | S&F of 150 mm dia Foot Valve, ball type, heavy-duty design, with cast iron body, SS ball, gunmetal seat, and corrosion-resistant stainless steel strainer, suitable for vertical mounting at pump suction in fire fighting supply system. Valve shall be flanged type, pressure rated PN 1.6, and designed for continuous water duty with minimal head loss. The item includes all accessories such as matching nut bolts, washers, gaskets, and jointing material, suitable for raw/ clear water application. |
| 22 | Supplying, installation, testing and commissioning of electric motor driven pressurisation pump (Jockey Pump) of capacity 180 LPM and 70 Mtr head, horizontal multistage centrifugal type with cast iron body, bronze impeller, stainless steel shaft and mechanical seal conforming to IS:1520, coupled with suitable HP squirrel cage TEFC induction motor for 415V, 3 phase, 50 Hz AC supply with IP55 protection and Class \"F\" insulation conforming to IS:325, mounted on MS fabricated common base plate including coupling, coupling guard, foundation bolts, etc., including construction of suitable cement concrete foundation block with excavation, PCC, RCC, plastering and finishing, and provision of heavy-duty anti-vibration pads, including testing, alignment, trial run and commissioning, complete all as specified and directed by GE. Make KSB Pumps, Wilo Mather & Platt, Grundfos |
| 23 | Supplying, installation, testing and commissioning of diesel engine driven main pump of capacity 97 CUM/ hr (1620 LPM) at 70 m head, horizontal type, multistage centrifugal pump with cast iron body, bronze impeller, stainless steel shaft and mechanical seal conforming to IS:1520, coupled with suitable HP diesel engine of 1500 RPM, water cooled with radiator, latest CPCB norms compliant and conforming to relevant IS standards. The set shall be complete with 12/ 24V battery-operated electric starting system including battery and interconnecting leads, panel-mounted LEDs for status indication, stop solenoid for automatic shutdown in the event of fault with audio alarms, and auto start/ stop mechanism. Also including fuel tank, fuel piping and fittings, and initial filling of diesel fuel (HSD), engine oil, and coolant oil. Exhaust piping extended up to 10 m from pump house, insulated with 50 mm thick glass wool and cladded with 1.0 mm aluminium sheet, complete with residential silencer. Pump set mounted on MS fabricated common base plate including coupling, coupling guard, foundation bolts, all mounted over suitable cement concrete foundation block with PCC, RCC, plastering and heavy-duty anti-vibration pads, complete all as specified and directed by GE.Note: After installation, IEM or representative of the Accepting Officer shall test the complete system at site. Necessary arrangement of testing shall be carried out by the contractor. Any minor item, which is not explicitly covered under the contract but is essential for the smooth and safe functioning of the system, shall be provided and incorporated by the contractor without any additional cost implication, to ensure proper and reliable operation of the installed system.Make : Pump Set: KSB / Grundfos / Mather & PlattDiesel Engine: / Volvo penta / Greaves / Ashok LeylandBatteries: Exide / Amaron / LuminousControl Panel Accessories: L&T / Siemens / Schneider / C&SPressure Switch/ Sensor: Indfos / Danfoss / Forbes MarshalNote : All Necessary civil Work, exhaust piping, insulation material etc., shall be deemed to be included in Qtd rate |
| 24 | S&L 1100V grade 2 core 1.5 sqmm fire survival armoured copper conductor cable, XLPE insulated, FRLS sheathed, ISI marked, conforming to IEC 60331/ BS 6387 (Cat CWZ), laid in/ on wall/ trench/ tray/ conduit with accessories like clamps, saddles, glands, lugs etc., complete all as specified and directed. Make Polycab / KEI / RR Kabel / Universal / Havells / Finolex |
| 25 | Supplying and fixing of standard and differential pressure switches, piston-operated type, suitable for working pressure range 0 to 16 bar, housed in weather proof enclosure with adjustable set point and manual reset provision. The switch shall be suitable for automatic operation of fire/ water pump sets and shall be complete with all necessary accessories including brass nipples, tees, sockets, fittings, mounting bracket etc, for proper installation and integration with piping or control panel all as specified and directed.Make : Indfos / Danfoss / Switzer / Schneider / Honeywell / Forbes Marshall |
| 26 | Supplying, & Fixing of glycerine-filled pressure gauge, dial type, 100 mm dia, pressure range 0 to 16 bar, bottom entry type, with stainless steel casing, bourdon tube, and brass/ SS connection, suitable for water and fire hydrant applications. The gauge shall be supplied complete with all necessary fittings including nipples, sockets, tees, reducers, elbows, and other accessories required for proper mounting on pump header, pipe or panel all as specified and directed. Make Wika / H Guru / Baumer / Fiebig / Waree / Yokogawa / H.Guru |
| 27 | Supplying, installation, testing and commissioning of factory-assembled, floor/ wall mounted, dust and vermin-proof MCC-type integrated control panel suitable for 415V, 3 Phase, 50 Hz AC supply, fabricated from CRCA sheet steel (3 mm th), CPRI Approved, powder coated, and suitable for operating one jockey pump and integrated control for one diesel engine driven main fire pump. The panel shall be complete with main incoming MCCB, suitable size copper busbars, feeder MCCBs for individual pumps, fully automatic soft starter for jockey pump with overload and under-voltage protection, relays, timers, auto/ manual selector switch, stop/ start push buttons, status indication LEDs, digital metering instruments (voltmeter, ammeter, PF meter etc.), and internal copper wiring with lugs, ferruling, and termination blocks. The panel shall also include integration with pressure switch (panel or field-mounted) and suitable control cable for automatic start/ stop of jockey pump based on line pressure, and provision for starting/ stopping and fault signal reception from the diesel engine driven fire pump set including auto-start logic, alarms, and indications all as specified and directed.Makes : MCCBs/ soft starter/ meters – L&T/ Schneider/ Siemens/ C&S. Pressure switch – Indfos/ Danfoss/ Forbes Marshall, control accessories – ABB/ L&T/ Schneider. Note: Necessary arrangement of testing shall be deemed to be included in the quoted rate. |
| 28 | Supply & fix single headed internal hydrant valve with instantaneous SS 304 coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank cap and chain as required all as specified and directed by Engr-in-Charge. |
| 29 | Supply & fix Short SS pipe 63mm male instantaneous inlet male threaded outlet fitted with 15mm bore nozzle as per IS:903 (ISI Marked) |
| 30 | Supply and fix 63mmdia, 15m long Reinforce Rubber Lined hosepipe with 63mm dia SS metal male and female couplings duly bound with GI wire, rivets etc conforming to IS 636 (type-A) complete all as specified and as directed by Engineer-in-charge. |
| 31 | Supply and installation of hose box, wall/ stand mounted type, fabricated from 1.6 mm thick mild steel (MS) sheet, cabinet size 600mm x 750mm x 250mm, with 4 mm thick clear glass front door, rubber beading and lockable key arrangement, suitable to accommodate two hoses of 15 m length each and one branch pipe with nozzle, cabinet duly powder coated (inside and outside) in approved fire red colour, including supporting stand for wall mounting, fasteners, bolts, clamps, and all accessories, complete all as specified and directed by Engineer-in-Charge. |
| 32 | Supply, installation, testing and commissioning of external type Inlet comprising 2 Nos. of 63 mm dia instantaneous type male gunmetal inlets with non-return valves, mounted on mild steel manifold with flanged outlet connection suitable for 100 mm dia fire hydrant main, complete with dust caps, gunmetal chains, 100 mm dia flanged sluice valve, MS support frame, GI / MS connecting pipe with necessary fittings, pressure testing, red enamel painting with “ INLET” stencil marking, all as per IS:3844 and IS:5290, including making good disturbed surfaces and complete all as specified and directed by the Engineer-in-Charge |
| 33 | M & L earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth electrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/ Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/ dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note :- The cost of 7.5m long galvanised iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI light grade is deemed to be included in quoted unit rate. |
| 34 | Supply and fixing of 500 litre capacity rotationally moulded polyethylene (HDPE) water storage tank (ISI marked), cylindrical vertical type with closed top, triple layer, UV-stabilised, food-grade inner layer, complete with 25 mm dia inlet, 25 mm dia outlet, 25 mm dia overflow and drain connections, including fittings such as PVC ball valves, union sockets, nipples, elbows, reducer bushes, washers, etc., hoisting and fixing in position on existing / new platform using suitable G.I. clamps, anchor bolts and base packing, including testing and connection to existing water line, complete all as specified and directed by Engineer-in-Charge. |
| 35 | Supply and fixing of 25 mm dia gunmetal air release valve, ISI marked as per IS:14845, single ball type, suitable for water and fire hydrant pipelines, with integral needle arrangement for flow control or isolation, including all necessary accessories such as unions, sockets, nipples, Teflon tape, clamps, and connection fittings, complete all as specified and directed by Engineer-in-Charge. |
| 36 | Supply and fixing of 25 mm dia gunmetal ball valve, ISI marked as per IS:14845, single ball type, suitable for water and fire hydrant pipelines, with integral needle arrangement for flow control or isolation, including all necessary accessories such as unions, sockets, nipples, Teflon tape, clamps, and connection fittings, complete all as specified and directed by Engineer-in-Charge. |
| 37 | Supply and fixing first aid 30Mtr Hose Reel with MS construction spray painted in post office red, conforming to IS884 complete with the following as required. i) 20mm nominal internal dia water hose thermoplastic (Textile reinforced) type-2 as per IS:12585 ii) 20mm nominal internal dia gun metal globe valve & nozzle. iii) Drum and brackets for fixing the equipment\"s on wall & Connections from riser with 25mm dia stop gun metal valve & MS pipe and socket.Make : Ceasefire / Karat / Secure zone / Kirlosker / Zoloto |