Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | M&L in replacement for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional arealaid in trenches / duct or fixed to wall / passing through pipe on pole with suitable size cable glands, crimping type cable lugs for stranded aluminum conductor of following sizes complete all as specified and directed :- |
| 2 | 4 Core X 25 Sqmm |
| 3 | 3.5 Core X 35 Sqmm |
| 4 | 3.5 Core X 50 Sqmm |
| 5 | 3.5 Core X 70 Sqmm |
| 6 | 3.5 Core X 95 Sqmm |
| 7 | 3.5 Core X 120 Sqmm |
| 8 | 3.5 Core 150 Sqmm |
| 9 | 3.5 Core 185 Sqmm |
| 10 | 3.5 Core 240 Sqmm |
| 11 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/Steel pole, laying of cable in trenches etc and getting out in hard / densesoil complete all as specified and directed. |
| 12 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed. |
| 13 | Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 14 | M&L filling riddled earth in trenches forcushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 10 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed.Note :- Thickness of riddle earth cushion after punning down only shall be measured for payment. |
| 15 | M&L brick protection with common burnt brick sub class ‘B’ of size 230 x115 x75 mm for cable protection complete all as directed by Engr-in-charge. |
| 16 | Supply and Lay reinforced precast concrete cable cover LV, Type I,flat, size 250x150x40 mm complete all as specified and directed. |
| 17 | Supply, lay, commissioning and testing of cable jointing Kit Heat shrinkable type for 1100 V grade cable for straight through jointwith jointing material and accessories suitable forLT UGcable of size16 to 50 Sqmm, 3.5 Core complete all as specified and directed. |
| 18 | All as per item No 8.00 above but suitable foraluminium conductor cable of sizefrom 70 sqmm, 3.5 Coreto 95 Sqmm, 3.5 Core |
| 19 | All as per item No 8.00 above but suitable foraluminium conductor cable of sizefrom 120 sqmm, 3.5 Coreto 150 Sqmm, 3.5 Core |
| 20 | All as per item No 8.00 above but suitable foraluminium conductor cable of sizefrom 185 sqmm, 3.5 Coreto 240 Sqmm, 3.5 Core |
| 21 | Supply, lay, commissioning and testing of cable jointing Kit for 1100 V grade cable for outdoor End termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size16 to 50 Sqmm, complete all as specified and directed. |
| 22 | All as per item No 12.00 above but suitable foraluminium conductor cable of sizefrom 70 sqmm, 3.5 Coreto 95 Sqmm, 3.5 Core |
| 23 | All as per item No 12.00above but suitable foraluminium conductor cable of sizefrom 120 sqmm, 3.5 Coreto 150 Sqmm, 3.5 Core |
| 24 | All as per item No 12.00 above but suitable foraluminium conductor cable of sizefrom 185 sqmm, 3.5 Coreto 240 Sqmm, 3.5 Core |
| 25 | Cutting the existing road/PCC surface straight by manual, depth and width not less than 1 mtr below ground level for passing of underground cable and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed. |
| 26 | Supply & lay in repairs Galvanised Iron tubing 40 mm bore, light grade in protection of cable at road crossing/hard standing/pole protection fixed with MS clamps of size 40 X 4 mm, nut bolts and washer as per site requirement including taking down old unserviceable pipes complete all as specified anddirected. |
| 27 | Supply & lay in repairs Galvanised Iron tubing50 mm bore, light grade in protection of cable at road crossing/hard standing/pole protection fixed with MS clamps, nut bolts and washer as per site requirement including taking down old unserviceable pipes complete all as specified anddirected. |
| 28 | Supply & lay Galvanised in repairs Iron tubing80 mm bore, light grade in protection of cable at road crossing/hard standing/pole protection fixed with MS clamps, nut bolts and washer as per site requirement including taking down old unserviceable pipes complete all as specified anddirected. |
| 29 | Trimming/pruning and removing of tree branches or any other foreign objects from HT/LT over head conductor and clearing the OH Line of any type and size for one span of any length in 2 way /4 way/6 way conductor system. Notes: (i) Insulators of any type, connectors and ACSR conductor of any size required at site will be measured and paid separately under relevant item of this schedule. (ii) The contractor is responsible for provision of Necessary T & P including craneand safety equipments to complete the job. |
| 30 | Cutting unaxious green growth and grass by manual labour or by machine at all 11 KV Electric Installation premises/around 2/4 Pole structure/ along the boundary fencing and removing rubbish from the site of work complete all as specified and directed. |
| 31 | Supply, Installation, test and Commissioning in replacement of factoryfabricated, out door type, LT Panel Board made out of 3.15 mm thick CRCA Sheetwith projected Globe roof for rain water protection Dust and Vermin Proof,Double door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embededwith 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installation complete all as specified and comprising of the following :– |
| 32 | (a) Aluminium bas bar 600 amps rating ,4 strips in 3 phase and half neutral, supported with suitable size of heavy duty porcelin stand lock with suitable sizeof brass nut, bolts and washer with heat shrinkable PVC sleeving.The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral.(b)MCCB 4 Pole 400 Amps 36 KA -01 No. Microprocessor release (Incoming)(c)MCCB 4 Pole 250 Amps 25 KA -01 No. Thermal magnetic release (Outgoing)(d)MCCB 4 Pole 200 Amps 25 KA -02 Nos. thermal magnetic release (Outgoing) (e) Indicator LED Type for RYB set of 3 - 01 set(f) Voltmeter 0-500 Volt Digitalwith selector switch - 01 No (g) Ammeter 0 to 600 Amps amps Digital with CTs and selector switch - 01No (h) Control wiring with PVC insulated multi stranded copper conductor, insulators for busbar mounting3 Nos of suitable CT\"s and accessoriesNote: (i) All Internal connectionbetween MCCB and Bus bar shall be connected by aluminium strip of suitable size and capacity.(ii) All MCCB to be connected with both side Spreader Link.(iii) Cable alley to be provided for connection of outgoing cablesThe rate shall deemed to be include in the item rate |
| 33 | Supply, installing, testing and commissioning, factory made and tested,LT panel board outdoor type, weather, vermin proof, cubical type, platform mounted, suitable for 415 volts, 3 phase 4 wire 50 Hz AC supply system all as specified and directed, with necessary bus bar arrangement with insulated bus bar 600 Amps rating , 4 strips in 3 phase and half neutral fashion, the panel should be dust proof,made out of 3.15mm thick CRCA mild steel sheet with 50x50x6mm angle iron frame with necessary earth work excavation, hinged doors, front and rear opening and locking arrangement and duly powder coated on the out side and inside, cable glands and lugs for incomming and out going cable etc, independent chamber to accommodate complete all as specified and directed including following accessories :-(b)MCCB 4 Pole 315 Amps 36 KA -01 No. Thermal magnetic release (Incoming)(c)MCCB 4 Pole 100 Amps 16 KA -05 No. Thermal magnetic release (Outgoing)(e) Indicator LED Type for RYB set of 3 - 01 set(f) Voltmeter 0-500 Volt Digitalwith selector switch - 01 No (g) Ammeter 0 to 600 Amps amps Digital with CTs and selector switch - 01No (h) Control wiring with PVC insulated multi stranded copper conductor, insulators for busbar mounting3 Nos of suitable CT\"s and accessoriesNote: (i) All Internal connectionbetween MCCB and Bus bar shall be connected by aluminium strip of suitable size and capacity.(ii) All MCCB to be connected with both side Spreader Link.(iii) Cable alley to be provided for connection of outgoing cablesThe rate shall deemed to be include in the item rate |
| 34 | Supply, Installation, test and Commissioning in replacement of factoryfabricated, outdoor type, LT FEEDER PILLAR BOX made out of 3.15 mm thick CRCA Sheet of suitable sizewith projected Globe roof for rain water protection Dust and Vermin Proof,Double door withboth side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs, and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installation complete all as specified and comprising of the following :–(a) Aluminium bas bar of 200 Amps - 04 Nosin 3 phase and half neutral fashion, supported with suitable size of heavy duty porcelain stand lock with suitable sizeof brass nut, bolts and washer with heat shrinkable PVC sleeving.The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral.(b) MCCB 100amps, 415 volt,16 KA Breaking capacity4 pole Electromagnetic release duly connected to Bus Bar asINCOMING- 01 Nos |
| 35 | Supply , fixing , connecting and commissioning and testing ofoutdoor type (automatic and manual operation) power factor improvement panel of capacity 100 Kvarincluding interconnection with LT panel with appropriate size of electric cable for transformer (Outdoor/Indoor) type panel factory made, weather proof , dust and vermin proof suitable for 1100 V/440 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 3.15mm thick CRCA sheetand having four Nos angle ironlegs made out of 50 x 50 x 6mm 90 cm long angle iron below frame with front door and Side/Back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with siemensgrey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground upto 45 Cms in PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles with on line monitring of Power Factor on web based application as specified and directed by Engr-in-Charge. |
| 36 | Incoming feeder:- |
| 37 | A. Incommer MCCB 160- Amp , Three Pole, Termal based release with adjustable O/L ,Adj S/C SettingFront Face, 16 KA rupturing capacity, Ics=100%Icu, Isolation with Positive Break Indication with Double Break Contacts, Standard Extended Rotary Handle, Spreaders, Phase Barrier.- 1 No |
| 38 | B.Metering Section- DigitalAmmeter (0-150)Amps, digital Volt Meter (0-500)Volts , RYB Indicating Lamps ,1 Set Control fuses, CTs.3 |
| 39 | C. Insulated Busbar of Aluminium of 150A Capacity for 3 phase,, fixed on Insulators, Busbar Should be PVC Sleeved with red. Yellow. Blue Colour, Busbar Support should be of smc/dmc - 1 set. |
| 40 | D. Multi 10 Step 440V, 5A (144 x 144) microprocessor based power factor controller provided in the command module for target power factorsetting,automaticadjustmentofdeadbankratio,digitalpower factor display. |
| 41 | Outgoing feeder :- |
| 42 | E. Accessories for5 KVAR heavy duty box type Capacitor Bank - 2 Nos :-Capacitor Duty Contactor 5 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA withstd. duty capacitor on indicators and selector switch. |
| 43 | F. Accessories for10 KVAR heavy duty box type Capacitor Bank - 3 Nos :-Capacitor Duty Contactor 10 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 20 A having breaking capacity 10 KA withstd. duty capacitor on indicators and selector switch. |
| 44 | G. Accessories for20 KVAR heavy duty box type Capacitor Bank - 3 Nos :-Capacitor Duty Contactor 20 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 63 A having breaking capacity 10 KA withstd. duty capacitor on indicators and selector switch. |
| 45 | H. Ventilating fans of required size to dissipate the heat liberated by capacitor unites complete with automatic switching on/off of fans depending upon the temperature of the pane; 230vac 1500rpm, 160cu.m/h flying leads |
| 46 | J. 10 Stpes Automatic Power Factor controllersteps Relay Micro proccessor based for switchting ON and OFF of capacitors to Display of voltage ,current,Active power ,apparent Power display of COS Ø ,THD voltage ,THD current,alarm indication for defective step,low power factor and axcesstemperature.The relay having volt freec/o contact,automatic detection and uses of optimum capacitor capable of 4 Quadrant operation and any phase offset requirement.Switching programm :LIFO combi Filter ,manual mode built in under and over voltage release with auto reset large voltage input band of 90V to 440 volt ,45 to 65 HZ,current measuring 10MA-5A suitable for CT x/1A andx/5A commissing without additional setting and programming.Three decimal power reading .Phasing out of fault capacitor bank Automatically . |
| 47 | K. All accessories prewired with suitable size copper Wirewith stand high temperature, housed in cubical panel made out of 3.15mm thick CRCA Sheet factory made duly powder coated front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer. Note: APFC Panel shall be manufacturedby original manufacturer only. The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf failing which panels so manufactured will not be accepted. |
| 48 | Supply , fixing , connecting and commissioning and testing ofoutdoor type (automatic and manual operation) power factor improvement panel of capacity 80 Kvarincluding interconnection with LT panel with appropriate size of electric cable for transformer (Outdoor/Indoor) type panel factory made, weather proof , dust and vermin proof suitable for 1100 V/440 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 3.15mm thick CRCA sheetand having four Nos angle ironlegs made out of 50 x 50 x 6mm 90 cm long angle iron below frame with front door and Side/Back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with siemensgrey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground upto 45 Cms in PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles with on line monitring of Power Factor on web based application as specified and directed by Engr-in-Charge. |
| 49 | Incoming feeder:- |
| 50 | A. Incommer MCCB 160- Amp , Three Pole, Termal based release with adjustable O/L ,Adj S/C SettingFront Face, 16 KA rupturing capacity, Ics=100%Icu, Isolation with Positive Break Indication with Double Break Contacts, Standard Extended Rotary Handle, Spreaders, Phase Barrier.- 1 No |
| 51 | B.Metering Section- DigitalAmmeter (0-150)Amps, digital Volt Meter (0-500)Volts , RYB Indicating Lamps ,1 Set Control fuses, CTs.3 |
| 52 | C. Insulated Busbar of Aluminium of 150A Capacity for 3 phase,, fixed on Insulators, Busbar Should be PVC Sleeved with red. Yellow. Blue Colour, Busbar Support should be of smc/dmc - 1 set. |
| 53 | D. Multi 10 Step 440V, 5A (144 x 144) microprocessor based power factor controller provided in the command module for target power factorsetting,automaticadjustmentofdeadbankratio,digitalpower factor display. |
| 54 | Outgoing feeder :- |
| 55 | E. Accessories for1 KVARheavy duty box type Capacitor Bank - 1 Nos :-Capacitor Duty Contactor 1 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor, on indicatorsand selector switch. |
| 56 | F. Accessories for2 KVARheavy duty box type Capacitor Bank - 2 Nos :-Capacitor Duty Contactor 2 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. |
| 57 | G. Accessories for5 KVARheavy duty box type Capacitor Bank - 1 Nos :-Capacitor Duty Contactor 5 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA withstd. duty capacitor on indicators and selector switch. |
| 58 | H. Accessories for10 KVARheavy duty box type Capacitor Bank - 3 Nos :-Capacitor Duty Contactor 10 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 20 A having breaking capacity 10 KA withstd. duty capacitor on indicators and selector switch. |
| 59 | J. Accessories for20 KVARheavy duty box type Capacitor Bank - 2 Nos :-Capacitor Duty Contactor 20 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 63 A having breaking capacity 10 KA withstd. duty capacitor on indicators and selector switch. |
| 60 | K. Ventilating fans of required size to dissipate the heat liberated by capacitor unites complete with automatic switching on/off of fans depending upon the temperature of the pane; 230vac 1500rpm, 160cu.m/h flying leads |
| 61 | L. 10 Stpes Automatic Power Factor controllersteps Relay Micro proccessor based for switchting ON and OFF of capacitors to Display of voltage ,current,Active power ,apparent Power display of COS Ø ,THD voltage ,THD current,alarm indication for defective step,low power factor and axcesstemperature.The relay having volt freec/o contact,automatic detection and uses of optimum capacitor capable of 4 Quadrant operation and any phase offset requirement.Switching programm :LIFO combi Filter ,manual mode built in under and over voltage release with auto reset large voltage input band of 90V to 440 volt ,45 to 65 HZ,current measuring 10MA-5A suitable for CT x/1A andx/5A commissing without additional setting and programming.Three decimal power reading .Phasing out of fault capacitor bank Automatically . |
| 62 | M. All accessories prewired with suitable size copper Wirewith stand high temperature, housed in cubical panel made out of 3.15mm thick CRCA Sheet factory made duly powder coated front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer. Note: APFC Panel shall be manufacturedby original manufacturer only. The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf failing which panels so manufactured will not be accepted. |
| 63 | Supply , fixing , connecting and commissioning and testing ofoutdoor type (automatic and manual operation) power factor improvement panel of capacity 120 Kvarincluding interconnection with LT panel with appropriate size of electric cable for transformer (Outdoor/Indoor) type panel factory made, weather proof , dust and vermin proof suitable for 1100 V/440 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 3.15mm thick CRCA sheetand having four Nos angle ironlegs made out of 50 x 50 x 6mm 90 cm long angle iron below frame with front door and Side/Back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with siemensgrey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground upto 45 Cms in PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles with on line monitring of Power Factor on web based application as specified and directed by Engr-in-Charge. |
| 64 | Incoming feeder:- |
| 65 | A. Incommer MCCB 160- Amp , Three Pole, Termal based release with adjustable O/L ,Adj S/C SettingFront Face, 16 KA rupturing capacity, Ics=100%Icu, Isolation with Positive Break Indication with Double Break Contacts, Standard Extended Rotary Handle, Spreaders, Phase Barrier.- 1 No |
| 66 | B.Metering Section- DigitalAmmeter (0-150)Amps, digital Volt Meter (0-500)Volts , RYB Indicating Lamps ,1 Set Control fuses, CTs.3 |
| 67 | C. Insulated Busbar of Aluminium of 150A Capacity for 3 phase,, fixed on Insulators, Busbar Should be PVC Sleeved with red. Yellow. Blue Colour, Busbar Support should be of smc/dmc - 1 set. |
| 68 | D. Multi 10 Step 440V, 5A (144 x 144) microprocessor based power factor controller provided in the command module for target power factorsetting,automaticadjustmentofdeadbankratio,digitalpower factor display. |
| 69 | Outgoing feeder :- |
| 70 | E. Accessories for10 KVARheavy duty box type Capacitor Bank - 3 Nos :-Capacitor Duty Contactor 10 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 20 A having breaking capacity 10 KA withstd. duty capacitor on indicators and selector switch. |
| 71 | F. Accessories for20 KVARheavy duty box type Capacitor Bank - 2 Nos :-Capacitor Duty Contactor 20 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 63 A having breaking capacity 10 KA withstd. duty capacitor on indicators and selector switch. |
| 72 | G. Accessories for25 KVARheavy duty box type Capacitor Bank - 2 Nos :-Capacitor Duty Contactor 20 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 63 A having breaking capacity 10 KA withstd. duty capacitor on indicators and selector switch. |
| 73 | H. Ventilating fans of required size to dissipate the heat liberated by capacitor unites complete with automatic switching on/off of fans depending upon the temperature of the pane; 230vac 1500rpm, 160cu.m/h flying leads |
| 74 | I. 10 Stpes Automatic Power Factor controllersteps Relay Micro proccessor based for switchting ON and OFF of capacitors to Display of voltage ,current,Active power ,apparent Power display of COS Ø ,THD voltage ,THD current,alarm indication for defective step,low power factor and axcesstemperature.The relay having volt freec/o contact,automatic detection and uses of optimum capacitor capable of 4 Quadrant operation and any phase offset requirement.Switching programm :LIFO combi Filter ,manual mode built in under and over voltage release with auto reset large voltage input band of 90V to 440 volt ,45 to 65 HZ,current measuring 10MA-5A suitable for CT x/1A andx/5A commissing without additional setting and programming.Three decimal power reading .Phasing out of fault capacitor bank Automatically. |
| 75 | J. All accessories prewired with suitable size copper Wirewith stand high temperature, housed in cubical panel made out of 3.15mm thick CRCA Sheet factory made duly powder coated front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer.Note: APFC Panel shall be manufacturedby original manufacturer only. The firms specified cannot authorize any other vendors to manufacture APFC Panels on their behalf failing which panels so manufactured will not be accepted. |
| 76 | M&L for preparation of old painted surfaces for outdoor/indoor Amf panel/LT Panel of any size with applying two coat of synthetic enamelled grey paint after removing all dust & rust and paint shall confirm to IS 2032complete all as specified . |
| 77 | Supply&Fixing in replacement of Auto/Manual selector swtich in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. |
| 78 | Supply & Replace in replacement MCCB along with both side spreader link and nut bolts of appropriate size in exisitng LT Panel box/ Feeder Pillar boxes (KIOSK),in MCCB DBsof capacity 315-400 Amps, 4 Pole, 35 KA, 415 Volt including disconnecting/taking out existing old unsv/burned MCCB complete all as specified and directed. |
| 79 | All as per item No 30.00 here in before but of capacity 250 Amps, 4 pole, 36 KA |
| 80 | All as per item No 30.00 here in before but of capacity 200 Amps, 4 pole, 36 KA |
| 81 | All as per item No 30.00 here in before but of capacity 160 Amps, 4 pole, 36KA |
| 82 | All as per item No 30.00 here in before but of capacity 125 Amps, 4 pole, 16 KA |
| 83 | All as per item No 30.00 here in before but of capacity 100 Amps, 4 pole, 16 KA |
| 84 | All as per item No 30.00 here in before but of capacity 63 Amps, 4 pole, 16 KA |
| 85 | Supply & Replace in replacement MCCB along with both side spreader link and nut bolts of appropriate size in exisitng LT Panel box / Feeder Pillar boxes (KIOSK),in MCCB DBsof capacity 250 Amps, 3 Pole, 35 KA, 415 Volt including disconnecting/taking out existing old unsv/burned MCCB complete all as specified and directed. |
| 86 | All as per item No 37.00 here in before but of capacity 200 Amps, 3 pole, 36 KA |
| 87 | All as per item No 37.00 here in before but of capacity 160 Amps, 3 pole, 36 KA |
| 88 | All as per item No 37.00 here in before but of capacity 63 Amps, 3 pole, 16 KA |
| 89 | S& F in replacement of MCB , SP 6-32 Amps ,C curve with breaking capacity 10 KA, including disconnecting / taking out existing old unsv/burned isolator complwte all as specied and directed |
| 90 | S&F in replacement MCB, TP 25-63 Amps, \"C\" Curve with breaking capacity 10KA, including disconnecting/taking out existing old unsv/burned Isolator complete all as specified and directed. |
| 91 | S&F in replacement MCB, SPN 32 Amps, \"C\" Curve with breaking capacity 10KA, including disconnecting/taking out existing old unsv/burned Isolator complete all as specified and directed. |
| 92 | M& L in repairs Advance Maintenance Free G.I. SAFE EARTHINGElectrodewith PIPE of not less than 50 mm outer dia) and two meterlength, The electrode should be ofgalvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm7.5 m . The GI Electrode shall be pre-filled with Crystalline Conductive Material (CCM). The GI electrode shall be surrounded with 25 kg Backfill compoundto provide maximum contact between the electrode and Back Fill Compound.connected to earthing test point including excavation, earth work, PCC pit, RCC cover 50 mm thick, lifting rod andtesting on completion, complete all as specified and directed.Make: ASHLOK/GRAVIN/TRUE POWER/JVM |
| 93 | S&F in replacement of Galvanised Iron Strip 32x6mm with Saddles and fixing Screws for Roof/Earth Conductors and Down Conductors above Ground including taking down unserviceable Strip, complete all as specified and as directed.NOTE : All Joints should be joined by Brazing or by using of nuts and bolts& washers. |
| 94 | S&F in replacement of Galvanised Iron Tubing/Pipe 40mm bore (dia), light grade for Strip Protection, fixed in Walls/Floors with suitable type of Clamps, etc. including taking down unserviceable GI Tubing/Pipe, complete all as specified and as directed. |
| 95 | S&F in repairs cable route indicator for LT UG cable of 1100 volts bolted with 25x5 mm flate iron member of height 0.60 mtrs and 80 mm CI plate embeded in PCC 1:3:6 type C2 of size 15x15x20 cm block complete all as specified. |
| 96 | Repair/maintenance, excluding major spares but including regualr maintenance of the Automatic Power factor correction panel capacity up to 200 KVARs and upto 12 stages installed atvarious locations at MCEME area including carrying out complete maintenance/ repairs as required of all the sub systems viz. basedcontrol panels, feeder pillar, APFC relay, Power capacitor bank, Power contactors, Control wiring, Monitoring CT,MCBs/ MCCBs for isolation (with all the accessoires) anybreakdownmaintenance and replacement of unserviceable parts, refixingof old serviceable parts/ new parts if anyproject completion and trouble shooting responsibility also lies with contractor including following provisions complete all as specified and directed. Notes:-(i) Rate quoted by tenderer is deemed to be inclusive of checking of system fortnightly, replacement of defective control wiring, small part such as Push button, lugs any auxilary contact, auto selctor switch etc and necessary servicing repair by expert technician and register will be maintaned for the same.(ii)The scope of work includes the labour charges required for removing, repairing, refixing, carrying out electrical termination, capacitors bank, APFC relay, power contactor, contol CT, MCBs/ MCCB and fixing/installing/testing and commissioning the complete system.(iii) Capacitors bank, APFC relay, power contactor, control CT, MCBs/ MCCBshall be measured and paid seperatly. |
| 97 | S&F in replacement of On-Load changeover switch (In sheet steel enclosure), (Side Handle), 4 pole of capacity 615 Amps, 415 Volts, 50 Hz, complete all as specified and directed. |
| 98 | S&F in replacement of off-Load changeover switch (In sheet steel enclosure),(Side Handle), 4 pole of capacity 200 Amps, 415 Volts, 50 Hz,complete all as specified and directed. |
| 99 | S&F off-Load changeover switch (In sheet steel enclosure),(Side Handle), 4 pole of capacity 100 Amps, 415 Volts, 50 Hz, complete all as specified and directed. |
| 100 | Supply and fix power contactor MCX-42 of having capcity 360 Amps 4 pole 2NO+2NC complete all as specified and directed.Make :- L&T Cat part No CS97022 or equivalent HPL / Schneider |
| 101 | Supply only of aluminium cable lugs of following sizes :- |
| 102 | 16to 25 Sqmm Size |
| 103 | 35to 50 Sqmm Size |
| 104 | 70to 95 Sqmm Size |
| 105 | 120to 150 Sqmm Size |
| 106 | 185to 240 Sqmm Size.Make : Dowell/Jaison. |
| 107 | Supply and fix in replacement of powerfactor correction capacitor, 5 KVAR, heavy duty 440 volts 50 Hz complete including taking down old unserviceable capacitor complete all as specified and directed. |
| 108 | All as per item No 59.00 here-in-before but 10 KVAR Capacitor Bank |
| 109 | All as per item No 59.00 here-in-before but 15 KVAR Capacitor Bank |
| 110 | All as per item No 59.00 here-in-before but 20 KVAR Capacitor Bank |
| 111 | All as per item No 59.00 here-in-before but 25 KVAR Capacitor Bank |
| 112 | S&F in replacement APFC relaywith auto-set functiont7/8 stage APFC relayMake:- L&T/ HPL/HAVELLS |
| 113 | Supply and fixing in replacement only capacitor duty contactor suitable for rating 5 kVAR ,50Hz,440v,3-ph,3-pole in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.Make: Schnieder/L&T/Seimens |
| 114 | All as per item No 65.00 above but 10 KVAR capacitor duty contactor |
| 115 | All as per item No 65.00 here-in-before but 20 KVAR capacitor duty contactor |
| 116 | All as per item No 65.00 here-in-before but 25 KVAR capacitor duty contactor |
| 117 | M&L in repairs Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size Complete all as specified and as directed |
| 118 | M&L for shingle or gravel, levelled and consolidated to gradient required of 50 to 75 mm spread thickness as specified for tranformer yards etc all as specified and directed. |
| 119 | Supply & Layingof Insulating mats 2.5mm thick made of Elastomer (a generic term that includes rubbers, latex and elastomeric compounds that may be natural or synthetic or a mixture or a combination of both) for use as floor covering for the protection of workers on ac and dc installations with the system voltages up to 11 kV ac and 240 V dc and as per Cl 5 of IS15652 latest Class B Cat II of Size 1m X 2m complete with Relevant Test Reports and fixing on floor with suitable adhesives complete all as specified and as directedNote:- the mat should be permanently pasted with the help of suitable adhesive/resin. All joints and comers shall be filled/coveredwith insulating material of matching colour. Matching colour and matching designed tapes should be used to maintain an aesthetic look of the installation. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail