| 1 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Up to 35 sqmm |
| 2 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm |
| 3 | Supplying, installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range-15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, THD <10% as per IEC 61000-3-2, P .F.>=0.95, IP-66,IK-10, CRI >80, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement,, suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000 ° K 4000 °K / 5700 ° K /6000° K / 6500 °K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90 deg * C ) 45 watt |
| 4 | LED Flood Light, powder coated pressure die cast aluminum (Systemlumen efficacy >135 lm/Watt) Supplying, installation, Testing &Commissioning of Flood Light, powder coated pressure die cast aluminumbody with built in or separate driver as per the requirement with Driverefficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz,Operating temp range -15 deg to 50 deg centigrade, internal surge protection of5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and overvoltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30deg120deg as per the application and the project requirement deg., suitable tiltable fitting, life time (LED,Driver & electrical circuitry) of minimum 50000Burning Hours with 70% of initial Lumen maintained till life ends as perLM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation ColorMatching) <5, Maximum power consumption should not more than thespecified rating and Fixture shall be of relevant BIS standard complete in allrespect i/c connections with 1.5 sq mm FRLS, PVC insulated copperconductor single core cable and earthing etc. as required with Minimum 5 yearOEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80Test report from NABL lab for alltesting required for LED fixtures as perBIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminumhousing such that LED junction temperature shall not rise above 90°C): 100 Watt |
| 5 | Supplying & drawing following sizesof FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required .(a) 3 x 1.5 sq. mm |