| 1 | Repair and preventive maintenance, servicing of DG set of capacity 10 KVA as per the OEM (Original equipment manufacturer) manual based on 250hours run / 3 Month run of the DG set, inspecting all the parts/portion for its serviceability of air intake system, fuel system, lubricating system, cooling system and electrical system and tracing out the faults, dismantling,cleaning, replacement of defective parts, and fixing of serviceable parts/refixing exist serviceable parts, rectification of leakage of fuel and oil from any parts/body of DG set, cleaning the out door body and inner body, checking and setting the parameters of system after repair and reassembling including testing on completion to the entire satisfaction of the Engr-in-Charge.Note: (i) The spare parts for servicing shall be measured and paid separately under relevent items of BOQ. (ii) The repair & servicing shall be carried out by the authorised service engineer of the manufacturer/company only. (iii) All spare parts shall be ordered to match with the existingmodel No of DGset. Engine Make:Kirloskar , Model No :EA16G1 |
| 2 | S&F lubricant Oil filter with O ring including matching with existing model of DG set 10 KVA complete all as specified and directed. |
| 3 | S&Ffuel filter element with O ringto match with the existing model of DG set 10 KVA complete all as specified and directed. |
| 4 | S&F Vbeltcogged for alternator pulley to match with the existing model of DG set 10 KVA complete all as specified and directed. |
| 5 | S&F Vbeltcogged for blower pulley complete to match with the existing model of DG set 10 KVA complete all as specified and directed. |
| 6 | M&L for calibration and cleaning of fuel injectors of DG set 10 KVA complete all as specified and directed. |
| 7 | Repair and preventive maintenance, servicing of DG sets of capacity 25 KVA as per the OEM (Original equipment manufacturer) manual based on 200hours run / 3 Month run of the DG set, inspecting all the parts/portion for its serviceability of air intake system, fuel system, lubricating system, cooling system and electrical system, inspecting, tracing out the faults, dismantling,cleaning, replacement of defective parts, and fixing of serviceable parts/refixing exist serviceable parts, rectification of leakage of fuel and oil from any parts/body of DG set, cleaning the out door body and inner body, checking and setting the parameters of system after repair and reassembling including testing on completion and entire satisfaction of of Engr-in-Charge.Note: (i) The spare parts for servicing shall be measured and paid seprately under relevent items of BOQ. (ii) The repair & servicing shall be carried out by the authorised service engineer of the manufacturer/company only. (iii) All spare parts shall be ordered to match with the existingmodel No of DGset all as directed. Engine Make:Kirloskar, Model No :HA394TCIG1 |
| 8 | S&F complete service kit including air filter, lube oil Filter, fuel filter to match with the existing model of 25KVA DG set complete all as specified and directed. |
| 9 | S&F Vbeltcogged for alternator pulley to match with the existing model of DG set 25 KVA complete all as specified and directed. |
| 10 | S&F VbeltCogged for blower pulley complete to match with the existing model of DG set 25 KVA, complete all as specified and directed. |
| 11 | S&F air filter element complete to match with the existing model of DG set 25 KVA complete all as specified and directed. |
| 12 | Repair and preventive maintenance, servicing of DG sets of capacity 62.5 KVA as per the OEM is manual based on 200 hours run / 3 Month run of the DG set, inspecting all the parts/portion for its serviceability of air intake system, fuel system, lubricating system, cooling system and electrical system, inspecting, tracing out the faults, dismantling,cleaning, replacement of defective parts, and fixing of serviceable parts/refixing exist serviceable parts, rectification of leakage of fuel and oil from any parts/body of DG set, cleaning the out door body and inner body, checking and setting the parameters of system after repair and reassembling incl. testing on completion and entire satisfaction of of Engr-in-Charge. Note: (i) The spare parts for servicing shall be measured and paid seprately under relevent items of BOQ.(ii) The repair & servicing shall be carried out by the authorised service engineer of the manufacturer/company only.(iii) All spare parts shall be ordered to match with the existingmodel No of DGset all as directed. Engine Make : Cotton Greaves , Model No : 4G11TAG22 |
| 13 | S&F complete service kit including air filter,lube oil Filter, fuel filter to match with the existing model of 62.5 KVA DG set complete all as specified and directed. |
| 14 | S&F Vbeltcogged for alternator pulley to match with the existing model of DG set 62.5 KVA complete all as specified and directed. |
| 15 | S&F VbeltCogged for blower pulley complete to match with the existing model of DG set 62.5 KVA, complete all as specified and directed. |
| 16 | M&L for calibration and cleaning of fuel injectors of DG set 62.5 KVA complete all as specified and directed. |
| 17 | M&L for cleaning the fuel tank both internally and externally by removing all the dust / sediments etc including writing of tank capacity, Date of cleaning and next due date for tank to be cleaning of DG Set 62.5 KVA complete all as specified and directed. |
| 18 | M&L for dismantling of radiator and taking it to work shop for overhauling & cleaning descaling with acid,leakage repair, welding brazing & refixing it duly repaired etc of DG set 62.5 KVA complete all as specified and directed. |
| 19 | M&L for tappet setting including replacement of gaskets and springs of DG set 62.5 KVA complete all as specified and directed. |
| 20 | S&F fuel gauge to match with the existing model of DG set 62.5 KVA complete all as specified and directed. |
| 21 | S&F fan belt to match with the existing model of 62.5KVA DG set complete all as specified and directed. |
| 22 | Repair and preventive maintenance, servicing of DG sets of capacity 82.5 KVA as per the OEM is manual based on 200hours run/ 3 Month run of the DG set, inspecting all the parts/portion for its serviceability of air intake system, fuel system, lubricating system, cooling system and electrical system, inspecting, tracing out the faults, dismantling,cleaning, replacement of defective parts, and fixing of serviceable parts/refixing exist serviceable parts, rectification of leakage of fuel and oil from any parts/body of DG set, cleaning the out door body and inner body, checking and setting the parameters of system after repair and reassembling incl. testing on completion and entire satisfaction of of Engr-in-Charge.Note:- (i) The spare parts for routine servicing shall be measured and paid seprately under relevent items of BOQ.(ii) The repair & servicing shall be carried out by the authorised service engineer of the manufacturer/company only.(iii) All spare parts shall be ordered to match with the existingmodel No of DGset all as directed. Engine Make : Kirloskar Green, Model no : 4H8901/1420055, |
| 23 | S&F complete service kit including air filter,lube oil Filter, fuel filter to match with the existingmodel of 82.5 KVA DG set complete all as specified and directed. |
| 24 | S&F Vbeltcogged for alternator pulley to match with the existingmodel of DG set 82.5 KVA complete all as specified and directed. |
| 25 | S&F VbeltCogged for blower pulley to match with the existingmodel of DG set 82.5 KVA complete all as specified and directed. |
| 26 | M&L for calibration and cleaning of fuel injectors of DG set 82.5 KVA complete all as specified and directed. |
| 27 | M&L for cleaning the fuel tank both internally and externally by removing all the dust / sediments etc including writing of tank capacity, Date of cleaning, and next due date for tank to be cleaning of DG Set 82.5 KVA complete all as specified and directed. |
| 28 | M&L for dismantling of radiator and taking it to work shop for overhauling & cleaning descaling with acid,leakage repair, welding brazing & refixing it duly repaired etc of DG set 82.5 KVA complete all as specified and directed. |
| 29 | Repair and preventive maintenance, servicing of DG sets of capacity 125 KVA as per the OEM manual based on 200hours run/ 3 Month of the DG set, inspecting all the parts/portion for its serviceability of air intake system, fuel system, lubricating system, cooling system and electrical system, inspecting, tracing out the faults, dismantling,cleaning, replacement of defective parts, and fixing of serviceable parts/refixing exist serviceable parts, rectification of leakage of fuel and oil from any parts/body of DG set, cleaning the out door body and inner body, checking and setting the parameters of system after repair and reassembling including testing on completion and entire satisfaction of of Engr-in-Charge. Note (i) The spare parts shall be measured and paid seprately under relevent items of BOQ. (ii) The repair & servicing shall be carried out by the authorised service engineer of the manufacturer/company only.(iii) All spare parts shall be ordered to match with the existingmodel No of DGset all as directed. (a) Engine Make : Crompton Greaves , Model No :4G11TAG26,(b)Engine Make : Kirloskar, Model No :4K1080TAG42, (c) Engine Make : Kirloskar, Model No :6H3501/0600777. |
| 30 | S&F complete service kit including of air filter,Lub Oil Filter, fuel filter complete to match with the existing model of 125 KVA DG set complete all as specified and directed. |
| 31 | S&F Air Filter element complete to match with the existing model of 125KVA DG set complete all as specified and directed. |
| 32 | M&L for Calibration and cleaning of fuel injectors of DG set 125 KVA complete all as specified and directed. |
| 33 | M&L for cleaning the fuel tank both internally and externally by removing all the dust / sediments etc including writing of tank capacity, Date of cleaning, and next due date for tank to be cleaning of DG set complete all as specified and directed. |
| 34 | M&L for Dismantling of radiator, taking it to work shop for overhauling & cleaning descaling with acid removal of leakage, welding brazing & refixing it duly repaired etc of DG set 125 KVA complete all as specified and directed. |
| 35 | M&L for tappet setting, including replacement of gaskets and springs of DG set 125 KVA complete all as specified and directed. |
| 36 | S&F water Pump to match with the existing model of 62.5KVA DG set complete all as specified and directed. |
| 37 | S&F fan belt complete to match with the existing model of 125KVA DG set complete all as specified and directed. |
| 38 | S&F hose Clip complete to match with the existing model of 125KVA DG set complete all as specified and directed. |
| 39 | S&F flexible Pipe to match with the existing model of 125KVA DG set complete all as specified and directed. |
| 40 | S&F water Hose Pipe to match with the existing model of 125KVA DG set complete all as specified and directed. |
| 41 | S&F water Pumpto match with the existing model of 125KVA DG set complete all as specified and directed. |
| 42 | S&F AVRplate to match with the existing model of 62.5KVA DG set complete all as specified and directed. |
| 43 | S&F alternator rubber couplingto match with the existing model of 125KVA DG set complete all as specified and directed. |
| 44 | Repair and preventive maintenance, servicing of DG sets of capacity 400 KVA as per the OEM manual based on 200hours run/ 3 Month of the DG set, inspecting all the parts/portion for its serviceability of air intake system, fuel system, lubricating system, cooling system and electrical system, inspecting, tracing out the faults, dismantling,cleaning, replacement of defective parts, and fixing of serviceable parts/refixing exist serviceable parts, rectification of leakage of fuel and oil from any parts/body of DG set, cleaning the out door body and inner body, checking and setting the parameters of system after repair and reassembling including testing on completion and entire satisfaction of Engr-in-Charge. Note (i) The spare parts for servicing shall be measured and paid seprately under relevent items of BOQ. (ii) The repair & servicing shall be carried out by the authorised service engineer of the manufacturer/company only.(iii) All spare parts shall be ordered to match with the existingmodel No of DGset all as directed. Engine Alt-583/6303/AL/19. Model No DV8TAG3, Make: Kirloskar |
| 45 | S&F complete service kit including of air filter, lub Oil Filter, fuel filter with O rings complete to match with the existing model of 400 KVA DG set complete all as specified and directed. |
| 46 | S&F Air Cleaner safety Element and air cleaner primary element for DG 400KVA complete all as specified and directed. |
| 47 | M&L for cleaning the fuel tank both internally and externally by removing all the dust / sediments etc including writing of tank capacity, Date of cleaning , and next due date for tank to be cleaning of DG set of capacity 400 KVA complete all as specified and directed. |
| 48 | M&L for Dismantling of radiator , taking it to work shop for overhauling & cleaning descaling with acid removal of leakage, welding brazing & refixing it duly repaired etc of DG set 400 KVA complete all as specified and directed. |
| 49 | Dismantling the alternator from the Diesel generator of Capacity upto 125 KVA set safely, Transporting to the workshop if required, Cutting the burnt out winding of the alternator including the insulation paper lining of the stator, Cleaning the stator and armature post, rewinding the armature or stator with same guage of copper wire of same thickness and have the same number of winds as of original winding for each set of coil precisely and compact without any unnecessary crimping or spacing, reassembling the alternatorin the DG Set giving a trial run of the DG Setcomplete all as specified and directed upto the entire satisfaction of Engr-in-Charge. |
| 50 | S&F replacement of coolant of exisitng make complete all as specified and directed. |
| 51 | S&F replacement of engine oil complete all as specified and directed. |
| 52 | Supply only distilled water complete all as specified and directed. |
| 53 | M&L for repair / overhauling of self starter 12 Volts including replacement of carbon brushes, bearing, bushes, rewinding of armature and field etc. and varnishing complete all as specified and directed. |
| 54 | S&F mineral oil based grease suitable for motors and similar applications in 10 Kg plastic sealed container complete all as specified and directed. |
| 55 | M& L for repairing of Diesel Generator set of Capacity 62.5 KVA by checking Valve seat, valve guide, checking the circuit, instrument charging generator and starting motor in the power supply system, adjusting each system to restore the dynamic performance and fastening performance of diesel engine parts with tappet setting and calibration to ensure good condition with replacement of following Parts like Upper Gasket- 02 Nos, Head Gasket- 02 Nos, Cylinder Liner- 04 Nos, Governor- 01 No complete all as specified and directed. |
| 56 | M& L for complete repairing of Diesel Generator set of Capacity 82.5 KVA by checking Valve seat, valve guide, checking the circuit, instrument charging generator and starting motor in the power supply system, adjusting each system to restore the dynamic performance and fastening performance of diesel engine partswith tappet setting and calibration to ensure good condition withdismantling, replacement and installingof following Parts like Delivery Valve- 04, cylinder Bearing- 02, Element -04, Governer Kit-01, Nozzle Testing- 04, Turbokit-01,Charger- 01 No complete all as specified and directed. |
| 57 | M& L for complete repairing of Diesel Generator set of Capacity 125 KVA by checking Valve seat, valve guide, checking the circuit, instrument charging generator and starting motor in the power supply system, adjusting each system to restore the dynamic performance and fastening performance of diesel engine partswith tappet setting and calibration to ensure good condition with dismantling, replacement and installingof following Parts like Delivery Valve- 04, Cylinder ring -04, Gasket Set-02, Nozzle Testing- 04, Turbokit-01No complete all as specified and directed. |
| 58 | S&F AVR plate to match with the existing model of 82.5 KVA DG set complete all as specified and directed. |
| 59 | S&F AVRplate to match with the existing model of 125KVA DG set complete all as specified and directed. |
| 60 | S&F AVRplate to match with the existing model of 400 KVA DG set complete all as specified and directed. |
| 61 | Supplyand fix Engine controller Panel Board for DG Set of Capacity 82.5 KVA for GENSET MODEL : KG/-82.5WS Make : Kirloskar (DSE6120MKII) along with complete wiring from the controller toEngine and alternator complete all as specified and directed. |
| 62 | Supplyand fix Engine controller Panel Board for DG Set of Capacity 125 KVA for GENSET MODEL : KG/-125KVA Make : Kirloskar along with complete wiring from the controller toEngine and alternator complete all as specified and directed. |
| 63 | Repairing of self starter replacing solenoid and winding of the armature coil upto the satisfaction and complete testing complete all as specified and directed. |
| 64 | Supply only 12 Volt, 150 AH Battery suitable for 62.5 KVA to 320 KVA Dg set having Superior Maintenance free characteristic, high charge retention characteristic, vent caps with advanced flame arrestors and micro porous filter disc to arrest acid fumes all as specified and directed by the Engr-in-Charge. |
| 65 | Supply only SMF 12 Volt, 26 AH Battery suitable for UPS set having Superior Maintenance free characteristic, high charge retention characteristic, vent caps with advanced flame arrestors and micro porous filter disc to arrest acid fumes all as specified and directed by the Engr-in-Charge. |
| 66 | Supply and fix fuel Sensorwith thermostat for the DG Set of capacity 62.5 KVA of existing make complete all as specified and directed. |
| 67 | Supply and fix fuel Sensor for DG Set of capacity 82.5 KVA of existing make complete all as specified and directed. |
| 68 | Supply and fix fuel Sensor for DG Set of capacity 125 KVA of existing make complete all as specified and directed. |
| 69 | Supply and fix Automatic Voltage Corrector for DG Setof capacity 125 KVA complete all as specified and directed. |
| 70 | Supply and fix thermostat for DG Set of capacity 82.5 KVA of existing make complete all as specified and directed. |
| 71 | Supply and fix thermostat for DG Set of capacity 125 KVA of existing make all as specified and directed by Engr-in-charge |
| 72 | Supply and fix SMPS Battery Charger for lead acid battery for Engine start applications operating input range 170 to 270V forced air Cooled, low stand by Power consumption and high efficency for 125 KVA DG set all as specified and directed by Engr-in-charge |
| 73 | Supply and fix onload changeover of Capacity 125 Amps conforming to IEC 60947-3 all as specified and directed. |
| 74 | Supply and fix in repair Spare coil suitable for ML6 Type contact all as specified and directed. |
| 75 | Supply and fix in repair 3 Pole Power contactors having AC 1 Ratings 160 Ampsconforming to IS/IEC 60497 all as specified and directed by Engr-in-charge. |
| 76 | Supply and fix in repair 3 Pole Power contactors having AC 1 Ratings 100 Ampsconforming to IS/IEC 60497 all as specified and directed by Engr-in-charge. |
| 77 | Supply & fix Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as specified and directed. |
| 78 | S&F galvanised iron steel tubing, 40mm bore, light grade with all fittings fixed complete to walls and ceiling or laid under floors complete all as specified and as directed. |
| 79 | M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5m below normal ground level, connecting to the galvanised iron earth strip 32x6mm size by means of bolls, nuts, check nuts and washers of galvanised iron and earth wire protected by provision of GI medium grade pipe 40mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agregates with 40mm thick cover of RCC (1:2:4) type B-1 including reinforcement and one handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering, perforated at bottom, 1.75 m long placed on top edge of earth plate, charcoal and common salt filled 150 mm thick all around the earth plate with fixing arrangement, funnel wire mesh and earth work in any type of soil returning filling in and removal of surplus soil to a distance not exceeding 50 m all as per electical plate No 3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. |
| 80 | Supply only Battery Chargerworking onsingle phase 230V, 50 Hz AC main supplymax current 6 Amps output Voltage 12-72 V fitted with double wound main isolated transformer, charge control and voltage controleffected by means of coarse and fine tapping switches all as specified and directed. |
| 81 | Supply only 18 Gauge 200/210 litres capacity close mouth Barrel internally Plain of Diameter 584mm and opening 50mm all as specified and directed |
| 82 | Supply only Herbicide/Weed Remover for Garden and outdoor Purpose nearthe surroundingofE/M Installations complete all as specified and as directed. |
| 83 | Repair and preventive maintenance, servicing of UPS of Capacity 20 KVAinncluding Cleaning and tightening all power connectionat input and output terminals, at all breakers and at the terminal posts and post on the rectifier and inverter legs, checking all the power Cabling for abrasion, burn Posts, overheating, swelling, leaking, checking Printed circuit Board arrangementwith replacement of following items all as directed and specified by Engr-in-charge:-(i) Supply and fix in replacement IGBT 600v/200a- 01 No suitable for and Upto 20KVA UPS all as directed by Engr-in-charge.(ii) Supply and fix in replacement driver card -01 No suitable for and Upto 20KVA UPS all as directed by Engr-in-charge.(iii) Supply and fix in replacement SMPS card - 01 No suitable for and Upto 20KVA UPS complete all as specified and directed.(iv) Supply and fix in replacement output Sensor TX PCB (350V/20-0-20) - 01 No suitable for and Upto 20KVA UPS complete all as specified and directed.(iv) Supply and fix in replacement Input Sensor TX PCB (415V/20-0-20) - 01 No suitable for and Upto 20KVA UPS complete all as specified and directed.(v) Supply and fix in replacement Charger card 360V- 01 No suitable for and Upto 20KVA UPS complete all as specified and directed. |
| 84 | Repair and preventive maintenance, servicing of 2 Ton E.O.T crane and electric control panel wiring & replace all parts, Main hoist brake Drum & Motor servicing CT gear box, motor and brake, all limit Switch and crane wheels checking, servicing, LT Gear Box, Motor Checking and servicing, Control panel install and connection properly including load testing on completion and entire satisfaction of Engineer-in-Charge with replacement of following items:Note- (i) The Cost of Spares are deemed to be inclusive in the quoted rate.(ii) All T&P items and Transportationrequired is deemed to be included in quoted rate.(iii) Load testing Certificate duly Vetted by Manufacturer shall be Produced by the Contractor after the Successful Completion of the work.(i) Supply and fix in replacement 63 A 3P 110VAC Contactor-01 No.(ii) Supply and fix in replacement 2 NO 2 NC Add Block 01 set. (iii) Supply and fix in replacement 40 A 3P 110VAC Contactor - 01 No.(iv)Supply and fix in replacement1 NO 1 NC Add Block- 01Set(v) Supply and fix in replacement 32 A 3P 110VAC Contactor -01 No.(vi)Supply and fix in replacement 8 Way Pendent Switch off ,Up down, left right and cross left right -01 No. |