| 1 | Earth work in surface excavation not exceeding 30cm in depth but exceeding 1.5m in width as well as 10 sqm on plan incluidng getting out and disposal of excavated earth upto 50m and lift upto 1.5 m as directed by Engr -in- charge (i)All kind of soil |
| 2 | Excavation work in ordinary soil by mechanical means ( hydraulic excavator) / manual means in foundation trenches or drains ( not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottom lift upto 1.5m incluindg getting out the excavated soil and disposal of surplus excavated soils as directed within a lead of 50 mtr |
| 3 | Providing and laying 1:4:8 ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size derived from natural sources) in position cement concrete of specified grade excluding the cost of centering and shuttering. All work upto plinth level |
| 4 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolanna / Ordinary Portlamd / portland slag cement admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete , to improve durability and workability without impairing strength incluidng pumping of concrete to site of laying, curing, carriage for all leads, but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engr-in- Charge for the following graded or concrete all works uptoplinth level . (i) Concrete of M-25 grade with minimum cement content of 330 Kg/ Cum for beam, lintel |
| 5 | Centering and shuttering including strutting, propping etc and removal of form for floor, Roof etc |
| 6 | Steel reinforcement for RCC workready to use \"cut and bend\" rebars of approved make from factory / workshop to construction site including placing in position and binding all complete above plinth level . (i)Thermo / Mechanically Treated bars of grade Fe- 500D or more |
| 7 | Demolishing brick work in cement mortarmanually / by mechanical means includng stacking of serviceable materials and disposal of unserviceable materials within 50 meter leads as per direction of engr -in- Charge |
| 8 | Brick work with common burnt clay F.P.S ( non modular ) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in cement mortar (1:6) complete |
| 9 | 15mm thick rendering in CM (1:4) on fair faces of brick work or concrete surfaces and finished the surface fair and even without using extra cement complete . |
| 10 | Demolishing cement concrete manually / by mechanical means including disposal of materials within 50 metres as per direction of Engr -in- Charge(i) Nominal concrete (1:3:6) or richer mix ( i/c equivalent design mix ) |
| 11 | Chequerred precast cement concrete tiles 22mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc complete on 20mm thick bed of cement mortar (1:4) ( 1 cement : 4 coarse sand) :- (i) Light shade pigment using white cement |
| 12 | Dismantling tiles work in floors and roof laid in cement mortar including stacking materials within 50 metres lead. (i)for thickness of tiles 8mm to 25mm |
| 13 | Providing and laying Double chargevitrified tiles size 600 x 600mm in floor in different size ( thickness to be specified by the manufacturer ) with water absorption less than 0.08 % and conforming to IS : 15622 of approved brand & manufacturer, in all colours and shade , laid on 20mm thick cement mortar 1:4 jointing with grey cement slurry @ 3.3 kg/Sqm incluidng grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily. |
| 14 | Providing and laying vitrified tiles in different sizes ( size of tiles 600 x 600 mm) ( thickness to be specified by manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours & shade , in skirting, riser of steps , over 12mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand), jointing with grey cement slurry @ 3.3 Kg / Sqm including grouting the joint with white cement & matching pigments etc complete |
| 15 | Making floor 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sandderived from natural sources : 6 graded stone aggregate 20mm nominall size derived from natural sources)well rammed and consolidated and grouted with fine sand. , dressing & finishing the top smooth. |
| 16 | Removing dry or oil bound distemper, water prooofing cement paint and the like by scrapping , sand papering and preparing the surface smooth including necessary repairs to scratches etc complete |
| 17 | Distempering on old work ( wall/ ceiling) ( one or more coats)with 1st qualityacrylic distember ( Ready mix ) having VOC content less than 50 grams/ litre of approved brand over a coat of water thinnable cement primerand manufacturer to give an even shade |
| 18 | Distempering Two or more coats on new workwith Ist quality acrylic distemper , having VOC ( Volatile Organic Compound) content less than 50 grams / litre of approved brand and manufacture of required shade and colour and Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface complete as per manufacturer\"s specification |
| 19 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 20 | Finishing wall New work ( Two or more coats applied @ 1.43 litre/ 10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10 Sqm with 100 % premium acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistance as per IS 15489 :2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade ( Company Depot tinted ) with silicon additives |
| 21 | Finishing wall with Acrylic smooth exterior paint on old work ( one or more coats applied @ 0.83 ltr/ 10 Sqm of required shade complete all as specified |
| 22 | Providing and fixing 18mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window cills, facias and similar locations of required size, approved shade , colour and texture laid over 20mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joint treated with white cement mixed with mateching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to edges to give high gloss finish etc complete at all levels (i)Granite stone slab colour black, chery / ruby Red , area of slab upto 0.50 Sqm |
| 23 | Steel work in built up tubularhot finished welded type tubes ( round, square or rectangular hollow tubes etc) trusses etc including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer incluidng welding and bolted with special shaped washers etc complete |
| 24 | M&L for steel anchor bolts of length 15cm long, dia of neck 10 to 12 mm complete fixed in position complete all as directed |
| 25 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified |
| 26 | S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges and valley gutters, fixed with self tapping screws as specified |
| 27 | Painting tosteel surfacewith synthetic enamel paint of approved brand and manufacture of required colour to give an even shade one or more coats of old surfaces complete |
| 28 | S&F 150 mm PVC (SWR) pipe single socketed in any length with rubber ring joints fixed to walls including all fittings (such as bends, elbows, Tee, short pieces, connectors, backnuts, diminishing pieces, caps,plugs and unions etc)complete all as directed. |
| 29 | M&L for Stainless steel framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings inclduding of steel sheeting or other covering, running rails and guides and hanging and locking arrengement; also fastening and fixing completeall as directed |
| 30 | S&F in repairs false ceiling with light weight calcium silicate tiles of spin tone surface textured \"Aerolite\" make or equivalent of size 595*595mm having 15mm thick densified micro look edge in true horizontal level suspended on silhouette profile suspension system of Grid made from hot dipped G.I steel section potary stitched double webbed power coated white.fixed to ceiling with 6mm dia and 50mm long dash fastener, 4mm dia G.I adjustable rods with galvanized level adjustment clips spaced as required at any heights as per specifications,including taking down existing ceiling board with frame work complete all as per direction of Engineer-in-charge. |
| 31 | Dismantling doors, windows and clerestory windows ( steel or wood) shutter including chowkhats, architrave, holdfasts etccomplete and stacking within 50 metres lead :- (i) of area 3 Sqm and below |
| 32 | providing and fixing pressed steel door frames conforming to IS: 4531, manufactured from commercial mild steel sheet of 1.60mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50 x 25mm, or base ties of 1.60mm, pressed mild steel welded or rigidly fixed together by mechanical means, incluidng M.S pressed butt hinges 2.5mm thick with mortar guards, lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre- treatment of the surface as directed by Engineer -in- Charge :-(i) Profile \"E\" fixing and adjustable lugs with split end tail to each jambs |
| 33 | S&F35 mm thick factory made pressed moulded panelled door of single or multi panel texured masonite moulded door fabricated using well seasoned and chemically treated solid second class hardwood styles, rails and panels made out of tubular core bonded with PF synthetic resin confirming to BWP grade IS: 848. Both faces shall be covered by hot pressing with high density fibre (HDF) of 2.8 to 3 mm thick imported masonite skin. The door\"s colour, texture design shall be approved by GE completeas specified and directed. |
| 34 | S&F 150 mm butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, with brass screws complete all as directed. |
| 35 | S&F 250 mm long brass, sliding door bolt with sand or die-cast brass hasp,staple (bolt type) and fixing bolt with rolled or drawn brass bolts andcomplete all as specified and directed. |
| 36 | S&F 200 mm longbrass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts complete all as specified and directed. |
| 37 | S&F 150 mm extruded brass handles,fabricated type polishedcomplete all as specified and directed. |
| 38 | S&Ffloor door stopper of brass body and tongue and with hard drawn steel spring 140 mm longwith screws. |
| 39 | Cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, etc and removing rubbish exc.1.5 km but nexc 5.00 km outside MOD premises. complete all as specified and directed. |
| 40 | S&F wooden frame with stainless steel wire cloth 304 grade stainlesssteel with 0.254 mm (30 gauge) dia of steel wire and 0.95 mm width of aperature and fixed along with aluminium anodised mesh of size 10x10x1.0mm thick fixedwith tinned tacks or galvanised wire staples etc fixed to brick wall / concrete at any hight any specification complete all as specified and directed. |
| 41 | Providing and fixing aluminiuim extruded sectionbody universal type hydraulic door closer ( having brand logo with ISI , Is : 3564, embosedon the body, door weight upto 36 to 80 kg and door width from 701 to 1000mm) with double speed adjustable with necessary accessories and screws etc complete |
| 42 | S&FSS cylindrical lock suitable for 30 to 40 mm thick shutter with duplicate keys complete. Make: Godrej/Link/Sheel |
| 43 | S&F Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers, properly rolled on glass panes without any wrinkle including removal of existing unserviceable film on windows/doors complete all as directed.Make : GARWARE OR EQUIVALENT |
| 44 | M&L of Herbal Pest Control Treatment organic method for internal and external walls will be carried out for termites, wasps, Bees, ants, fleas, cockroaches, rats, mice, lizards, rodents,and squirrels ans etc and use plant-based, non-toxic, eco-friendly, and biodegradable medicines, insecticides, and pesticides in treatment process and for termaite using chemical chemical 350ml per hole (Bayer Agenda EC25 Chemical or Equalent), at 300mm intervals including drilling holes at 45 degree and replugging them with white cementand treatment will be carryout in entair three BHK flats with Servent qtr including Cupbords as directed. Note : 1. Contractor should be provide Test certified for non-toxicity and No side effects by a recognised testing laboratory.2. Contractor should be provide 12 Months guarentee for treatment. |
| 45 | Shifting of UPS system with batteries and shiftting of phase reversal box from existing location to new location and fixing again with necessary connection with removing material and makingdisturb surface of wall floor of existing location. |
| 46 | M&L for earthing complete with Galvanised steel earth plate electrode 60cm x 60cm x 6.3mm, buried directly in ground( earth pit not less than 2.25 mtrdeep below ground level) with top edge of the plate not less than 1.5m below ground level connected to and including GIstrip 25x4 mm protected with GI medium grade pipe 15mm dia for earth electrode upto test point or upto 7.5 mtr whichever is less by means of bolts, nuts, check nuts and washers all shown in electrical plate No 3 (of SSR part-I) connected to earthing test point all as specified or indicated including provision of necessary excavation and earth work of any type of soil, PCC pit , RCC cover, 50mm thick with 8mm dia TMT bar @ 100cm c/c both way , 20mm bore light grade watering pipe, water funnel, 40mm bore GI medium grade protection pipe, comman salt, charcoal dust, returning filling, in of soil, removal of soil to a distance of not exceeding of 50 mtr etc, including testing on completion complete. |
| 47 | Earthing with copper earth plate 600 mm x600x3mm thickincluding accessories,and providing masonry enclosure with cover plate having locking arrangement and watering pipeof 2.7 metre long etc.With charcoal/coke and salt as required. |
| 48 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS is PVC insulated copper conductor, single core cable in surface/ recessed as required 4 x4 sq. mm + 2x4 sq. mm earth wire |
| 49 | S&F LayingLT UG cable heavy duty armoured with aluminum conductor multistranded PVC insulated and sheathed with suitable lugs including taking out old unserviceable cable complete all as directedfor following sizes: - 3.5 core x 35 Sqmm |
| 50 | Supply & fabrication of LT Panel BoardCPRI approved cubical type made of 2 mm thick sheet steel indoor typewith IP 43 grade of protection CRCA sheet powder coated with support of angle iron of 50 x 50 x 6 mm with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors PVC sleeved Aluminium bus bar of400Amps, 415V capacity for each phases andhalf neutral fixed on suitable insulator all housed in suitable bus bar chamber and cable alley andprovision and fixing of LED digital Voltmeter,Ammeter with built in selector switch, CTs of suitable ratio, and pilot indication lampsconnecting incoming and out going cables with suitable cable glands etcwith suitable PCC foundationscomplete testing and commissioning complete andconsisting the followingMCCB,4P,250 Amp 36 KA -01No (I/C)MCCB,4P,63 Amp 10 KA -06 Nos |
| 51 | Provision and fixing Chlorinated Polyvinyl Chloride (CPVC) 20 mm nominal dia pipe having thermal stability for hot &cold water supply,including all CPVC plain & brass threaded fittings,including fixing the pipewith clamps at 1.00 m spacing.this includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. |
| 52 | Supply and fixing 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 53 | SP 5 To 32 AMP |
| 54 | SPN 40 to 63 AMP |
| 55 | Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 10 sq mm ,4 core, 1100 Volts grade. |
| 56 | Supplying and fixingMCB DB 6 way, SPN, double door, IP 43 protection sheet steel enclosure duly powder coated fixed in recess/ flush in wall inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar |
| 57 | Supplying and fixing 30 A, 415V,TPN Industrial type socket outlet with 4 pole and earth, metal enclouse plug top along with30 A \"C\" curve TP MCB in sheetsheet steel enclosure on surface/ recess along with chained metal cover for the socket outlet and complete connection testing and commissioning. |
| 58 | Supply and fix MCCB 250A, 36KA, 415V TPN, 50 HZincluding sheet metal enclosure on surface or in recess complete with connection |
| 59 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick using soil complete all as directed. |
| 60 | Removing excavated material to a distance exc 250m but n exc. 500m and depositing where directed at a level n exc. 1.5m above the starting point (Soils) complete all as directed. |
| 61 | Supply and spreading naturaldry, clean river sand in trenches for cushioning of cable complete all as directed. |
| 62 | M&L for brick protection with common burnt bricks sub class ‘B’ of size 230x115x75mm for cable protection complete all as directed. |
| 63 | Supply and fixing 250Amps change over switch indoor enclosure 2 mm/1.6mm CRCA sheet with powder coating,including aluminium bus bar links minimum 250 mm clearence from bottom to link ends complete all directed |
| 64 | Supply and install split type air conditioner of capacity 1.5 TR complete with indoor/outdoor complete witil cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2. complete all as directed. |
| 65 | Supply and fix Voltage stabilizer of capacity 4KVA for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5%. |
| 66 | Supplyinstallation testing and commissioning of silent Diesel Engine driven , generating set 415 volts, 100 KVA / 80 KW 3 phase0.8 power factor 50Hz, 1500 RPM, Liquid Cooled, With all complete all connected acessories in all respects for commissioning of the DG Set, with CPCB -IV+ type latest approved and, self excitedself regulated brushless AC generator installed including accoustic enclosure suitable for ambient condition at Hyderabad including testing carried out by the contractor in presence of IEM, Engr-in-Charge & rate included of DG Set testing is deemed in quoted rate including AMF panel and confirming to condition under IS 4722/1460, BS 5514/2613/5000 ISO 8526/3046 with the following |
| 67 | Alternator - Standard design alternator, Power Rating 100 KVA/ 80 KW, 3 Phase 4 wire,415 Volts, 50 HZ, Power factor 0.8(lagging)Current 203 Amps,net output at site after considering derating for per site conditions at 0.8 (lagging) power factor, 1500 RPM, Cooling Water cooled, Aspiration Turbo charged, air cooled self regulated screen protected drip proof IP 23 enclosure brushless design with widing in pole faces, insulating class \"H\" and voltage regulation of +1% at rated voltage from no load to full load, A1 The alternator shall be conforming to BS 2613/5000 and shall be in position to generate supply with frequency regulation with in +1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS-2613/5000/IS-4722.Make of the Alternator : |
| 68 | Diesel Engine : Minimum 156 BHP capacity, multi stroke, 6 Cylinder,TurboChargedDiesel Engine suitable for 100 KVA coupled with alternator and after considering derating as per site conditions after generating and reducing power consumed by accessories, directly coupled through flexible coupling, multi cylinder, multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS-5514 with an overload capacity of 10% for one hour in 12 hours continous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessoires shall be as under :- Insulation class - \"H\" , Temperature rise class - \"H\" ,Excitation- Self excited Regulation performance - The voltage is kept constant with + 1%, manual voltage adjustment with in + 5%. ,Frequency Regulation + 1% Suitable size & suitable number of runsof UG copper cable (Control cable) from Alternator to AMF & RAW Power to AMF Panel is deemed to be include is quoted rate. |
| 69 | (i)Flywheel with housing(ii) Cooling System : Mounted radiator with fan and belts(iii)Cooling Water Pump : Centrifugal type belt driven(iv) Exhaust System : As per OEM reccommendation/specification.(Exhaust system high should be building hight + 03 mtr)(v)Starting System:- Electric Self Starter with maintenance free batteries including battery charging alternative belt driven.(vi)Batteries :- 24 Volts DC electrical batteries ofsuitableAH rating, complete connected with copper cable PVC sheathed conductor multistranded leads of suitbale length from self starter to the battery terminals complete with initial charge and initial fill of electrolite all as specified and directed.(vii)Fuel tank of adequate capacity :- As per OEM norms and specifications designed for above capacity of DG Set. |
| 70 | AMF Panel : Auto Main Failure (AMF) Panel made out 14/16 Gauge CRCAsheet weather proof powder coated conforming to IS 8623 totally enclosed dust and vermin proof with front and rear openings of 415 Volts, 3 Phase, 4 wireAC 50 HZ having aluminium bus bar of capacity required to carry current at 100% load of 100 KVA DG Set with three phase and half neutral colour coded pre-wired with copper flexible cable, all as specified with the following accessories, control cable from Gen Set to AMF Panel.Contactor of Suitable capacity 4 pole with required nos as per OEM, TP contactor for netural for both suppliesSuitable capacity of MCCB, 4 Polefor both supplies CTs 150/5A for both the supplies Push buttons Indication Lamps 2 over load + earth leakage relayMulti functional digital meter for KWH, KVA, KW, Amps, Volts, frequency, power factor etc.SMPS Battery charge 24 V, with trickle and boost charging.ON/OFF Switch.Automatic/Manual Switch.Hooter. Voltage sensing relay.Six window anunciator for fault indications. |
| 71 | Acoustic Enclosure : Enclosure is free standing floor mounted factory built and modular in construction to facilitate easy assembly at work site and will be drop over housing type. It will consist of acoustically treated panel housed in sheet metal will provide easy access for maintenance, repairs and operation. The enclosure is custom to suit conditions, with the following features :- |
| 72 | (i) Custom built product for various equipments, with ensure the optimum performance without duration.(ii) 16SWG (1.6mm) thick CRCA sheet to be used for enclosure panel to ensure longer life against weathing action. High quality acoustic insulation materials to be used as per IS 8183 for maximum sound absoption. Acoustic layers are supported by perforated sheets.(iii)Sheet metal component of the enclosure should undergo various stages of surface treatment prior to painting which leads to be better life of the enclosure against weathering action.(iv) Specialpaint treatment with pure polyster powder/epoxy to be provided for better weather resistance.(v)Well designed ventilation system to be provided to put out the heat from the chamber efficiently.(vi) For effective acoustic/weather sealinga special type weather sealing gaskets, new frame rubber gaskets to be used. |
| 73 | (xiv) The batteries should be placed inside the enclosure inside the DG Set on a suitable insulated platform.(xv)The DG set should be provided with external emergency stop push button.(xvi)Provn of 2 Nos 11 Watts LED lamp fitting of approved Make incl wiring inside canopy with single switch controlled.(xvii)Fuel gauge to be provided with the neck of fuel tank.(xviii) Tools as per manufacturers with the box.(xix)Invents of suitable company be manufacture.Making of foundation for placement of DG Set as per site requirement and including provision of anti-vibration pads are deemed to be included in duoted rate. |
| 74 | Supply and Fix XLPE insulated, armoured heavy duty electric cable withaluminium conductor, 1100 volts grade, cross-sectional area 120 sq. mm 3.5 Core |