| 1 | Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for foundation etc. orfor shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sq. m on plan and not exc 1.5m in depth and getting out in soft/loose soil, complete all as specified.Note :- During the execution of work, In case of any damage to tha GAS pipe line ,water supply pipe , electric cable etc , the contractor will have to get it repaired/ replaced at his own cost and noting extra payble on this acount. |
| 2 | All as per item No 1 here in before but depth exceeding 1.5 m and not exceeding 3.00M |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all as specified. |
| 4 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 5 | Demolition and breaking up old unserviceable salt glazed stoneware/pvc/ SN8 pipe 150mm bore at any depth set in cement morter incl PCC bed complete all as specified and directed. |
| 6 | All as per srl item no. 05here-in-before but 200 mm internal dia of pipe. |
| 7 | M&L for PCC 1:4:8 type D-2(using 40mm graded crushed stone aggregates) bedding forsewage lines of 150mm bore incl packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed. |
| 8 | All as per sl item No 7 above but for bed of sewage line of 200mm bore. |
| 9 | S&F class SN-8, dia of pipe 150mm & thickness of pipe as specified in IS 16098 (Part-2):2013, clause 6.3.1 table no 5 structured wall polythelene piping system (pipe with online/offline coupler and elastomeric sealing ring) with non smooth external anular corrugated and smooth internal surface (DWCP) for non pressure underground sewerage & drainage application polythylene piping fitted with help of coupler attached with one end of pipes, sliding over the elastomeric sealing rubber ring placed on the specified valley of the corrugation at the spigot end, lowering the same into the trench, laying at prescribed gradient, depth and alignment, testing the water tightness of the joint, ensuring the continuity tests of the specified pipe segments etc including all necessary fittings (cost of fittings, rubber rings, gaskets etc includded) complete all as specified and directed by Engineer-in-charge. |
| 10 | All as per sl item No 9 above but for dia of 200mm bore. |
| 11 | M&L for Cutting into existing manholes for connecting 150/200 mm bore of pipe new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified. |
| 12 | Demolition of brickwork built in cement mortar including all quoins ,arches ,pillars etc complete all as specified and directed. |
| 13 | M&L for brick work with subclass `B` bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified. |
| 14 | M&L for PCC 1:3:6 type C-2 using 40mm crushed graded stone aggregate as in foundation, filling and mass concrete complete all as specified and as directed. |
| 15 | M&L for cement concrete1:2:4 type B-1 (using 20mm graded crushed stone aggregate as in coping and similar works including necessary form work complete all as specified. |
| 16 | Taking down Cement /Grit Plaster, any description on brick walls or on concrete surfaces including raking out Joints, hacking for key, scrubbing down with Water, etc., and removing same from the Site(s), complete all as specified and as directed. |
| 17 | M&L for Rendering 15mm thick on any face of brick work in cement mortar 1:4, finished plastered surfaces even and smooth without using extra cement, complete all as specified and as directed. (WPC measured and paid separetly) |
| 18 | M&L for Rendering 15mm thick on inside face of of brick work in cement mortar 1:3 in manhole & drain, finished plastered surfaces even and smooth with using extra cement, complete all as specified and as directed.(WPC measured and paid separetly) |
| 19 | M&L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings .complete all as specified (Payment for providing grooves shall be made separately). |
| 20 | M&L for Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge |
| 21 | Supply only water proofing compound ISI marked complete all as specified and as directed. |
| 22 | M&L for preparation new surfaces of walls and cornices spoiled bysmoke soot, moulds, moss and efflorescent salts and tradingoil and greasy spots by scraping and washing with water and applying two coat of cement base paint complete all asspecifiedand directed by Engineer-in-Charge. |
| 23 | M&L for complete removal of existing treatment from old decorated plastered surfaces of walls and cornices spoiled bysmoke soot, moulds, moss and efflorescent salts and tradingoil and greasy spots by scraping and washing with water and applying two coat of cement base paint complete all asspecifiedand directed by Engineer-in-Charge. |
| 24 | M&L for providing cement concretetype B-I , 1:2:4(using 20 mm graded crushed stone aggregate)as in drain ,channels , roof kerbs or mud stops, rounded or chamfered on edges complete all as specified . |
| 25 | M&L Mechanically Operated truck mounted desludger with 12000 Ltrs capacity tanker having water fitted high pressure jet machine for cleaning and 12000 Ltrs capacity truck mounted with sucker machine for desludging of sewage line, soak wells , septic tank etc shall be used by the contractor as per scheduled programme in writing and completion on each job to the entire satisfaction of Engineer-inh Charge as instructed. Note :- (a) Per day means 8 working hours in a day excluding stand by period due to any sort of reason .(b) In case contractor fails to deploy the machine as per schedule programme a recovery of Rs 1500 per day shall be deducted from his payment. |
| 26 | Demolition of reinforced cement concrete of any description and in any position & removed all rubbish from MOD land complete all as specified. |
| 27 | M&L for RCC (Nominal mix) type B-1, 1:2:4 (20mm graded aggregate) in bend ,beam , cover slab ,columns, pillars, piers, posts and struts, complete all as specified and as directed by Engr-in-charge |
| 28 | M&L mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending, spirally for hopping for columns, hooking ends, and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S or Fe-410-0 complete all as specified & directed. |
| 29 | M&L for Rough finished flat surfaces concrete Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels,antilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. all as directed by Engr-in-Charge |
| 30 | S&F in repair Precast Cement concrete (M-30 Grade of concrete) manhole / drain cover of size 1000mm x 500mm x 80mm thick srounded with steel strip 80x1.25mm Reinforced as per manufacturer\"s design in Munufactured proccess laid over drain/MH inculding removed old cover from MOD land complete all as specified and as directed by Engr-in-Charge. |
| 31 | S&F in repair Precast Cement concrete (M-30 Grade of concrete) manhole/drain cover of size 750mm x 750mm x 70mm thick srounded with steel strip 70x1.25mm Reinforced as per manufacturer\"s design in Munufactured proccess laid over drain/MH inculding removed old cover from MOD land complete all as specified and as directed by Engr-in-Charge. |
| 32 | S&F in repair Precast Cement concrete (M-30 Grade of concrete) manhole/drain cover of size 600mm dia & 75m thick with srounded with steel strip 75x1.25mm Reinforced as per manufacturer\"s design in Munufactured proccess laid over drain/MH inculding removed old cover from MOD land complete all as specified and as directed by Engr-in-Charge. |
| 33 | S&F in repair Precast Cement concrete (M-30 Grade of concrete) GT cover of size 500mmx400mm x50mm thick or as per site requirement with one handle & 150mm dia notch in cover inculding removed old cover from MOD land complete all as specified and as directed by Engr-in-Charge. |
| 34 | Demolition of cement concrete in ground floors of any description and in any position not otherwise specifically provided(un reinforced) complete all as specified. |
| 35 | M&L 75mm thick cement concrete 1:3:6type B2 using 40mm graded stone aggregate as in plinth protection Complete all as specified. |
| 36 | M&L providing 75mm thick cement concrete 1:4:8 type D-2 using 40mm graded aggregate in sub base of floor complete all as specified and directed by Engr-in-Charge. |
| 37 | M&L 100mm thick Cement concrete type B-2,1:4:8 (40 mm gradd aggregate) graded stone aggregate in sub base of floor complete all as specified and directed by Engr-in-Charge. |
| 38 | M&L for 100mm thick Ready Mixed Cement Concrete ( M-25) as stamp concerting in floors ,sub base ,base etc & preparing a concrete floor with a textured, imprinted finish to resemble natural materials like stone or brick. The process includes preparing a base, pouring concrete, applying color hardener, and using release agents and stamps to create the desired pattern. Finally, the surface is sealed for protection and enhanced color including formwork to edges of concrete flats, breaks in floors, openings in concrete floors , horizontal or sloping complete all as specified and directed by Engr-in-charge. |
| 39 | M&L for pre cast Kerb stone with plain fair faces 300mmx300mmx100 mm or any size (as per site requirements) of PCC 1:1 ½ :3of shape as approved jointed in 1:6 cement mortar incl all excavation, embedding in ground and removing surplus spoil upto 500 Mtr distancecompleted all as specified and as directed by Engr-in-Charge. |
| 40 | M&L Preparation of old/ new Brick ,stone, concrete, asbestos cement or plastersurfacesof anydescriptionnot otherwise described, over10 cm widthor girth and applying two coat of synthetic enamel paint all asspecifiedand directed by Engineer-in-Charge. |
| 41 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and directed by Engr-in-Charge. |
| 42 | M&L for coloured chequered Cement concrete tile glazed finish 300mm x300 mx25mm or 400mmx400mmx25mm, machine pressed; set jointed and pointed in neat cement slurry in floors, with grey cement and pigments laid over 15 mm thick screed be in CM 1:6 complete all as specified. |
| 43 | S&F for Machine pressed precast concreteinterlockingglazed paver block with grey cement andpigment ofany shape and size conforming to IS 15658 - 2006 of 60 mm thickness, M - 35 grade etccomplete all as specified and directed. |
| 44 | M&L for 50 mm thick Sand filling under floors or in foundations including watering and consolidation. |
| 45 | M&L for hard core using broken stone or boulders of gauge not exc 63mm, deposited, spread, levelled, watered and well rammed to a true surface,complete all as specified and directed by Engineer-in-Charge. |
| 46 | M&L for Up rooting of trees and accumulated mud and grass on top of roof and around of wall by dismantling brick works in any mortar and mix PCC plastered surface of any description not exc 30 cm girth of trees and disposal of unserviceable material to a distance n.exc 50M including and making good to match with existing surface of double storey with necessary scaffolding complete all as specified and as directed. |
| 47 | Dismantling of concrete, asbestos,PVC pipesof any dia and discription from trenches or with walls etc complete all as specified. |
| 48 | M&L for 110mm bore PVC ( SWR) pipes, single socketed, in any length with rubber ring, joints, laid in trenches or in floorsall as specifid and directed. |
| 49 | M&L for 110mm bore PVC ( SWR) pipes, single socketed, in any length with rubber ring, joints fixed to wall all as specifid and directed. |
| 50 | M&L for PVC (SWR) bends of 110mm radius complete all as specified. |
| 51 | M&L for 75mm bore PVC ( SWR) pipes, single socketed, in any length with rubber ring, joints, laid in trenches or in floorsall specifid and directed. |
| 52 | M&L for PVC (SWR) bends of 75mm radius complete all as specified. |
| 53 | M&L in repair stack clamps for 75/100 bore pipe as in repairs out of 50mm by 5mm flat iron and 16mm dia round iron stays incl bolt and nuts and securingend of stays to wall or roofs complete all as specified and as directed. |
| 54 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete as directed by Engr-in-Charge. |
| 55 | S&F for 2mm thick fibre glass reinforced translucent plain sheeting fixed with coach screw and washer in roof, wall etc. complete all as specified. |
| 56 | S&F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws complete all as specified. |
| 57 | S&F Pre-Painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall,fixed with self tapping screws complete all as specified. |
| 58 | S&F 8 mm thick Polycarbonate reinforced coloured plain sheeting fixed with coach screws and washers in roofs,vertical surfaces etccomplete all as specified and directed by Engr-in-Charge. |
| 59 | Supply only Chain link MS galvanisd fencing, any size or type. |
| 60 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire etc complete all as specified and directed. |
| 61 | Restriainingresecurigincluding making good staples or tighting of cross wire galvanised barbed wire in any dia of wire or any spacing all as specified and directed by Engr-in-Charge. |
| 62 | S&F in repair Galvanised. 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails strain-ing bolts,including, securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins , etc, as directed (each line wire to be measured) complete all as specified. |
| 63 | S&F in repair 950/650/450 mm dia (as directed by Engr-in-Charge) concertina coil reinforced punched(chrome razor or blade wire with barbed top of 0.5mm thick galvanised sheet and core wire of dia 2.5mm of high tensile steel wire incuding galvanised MS staples/ Clips for tying at crossing complete including taking down of existing concertina coilall as specifiedand directed by Engineer–in-Charge |
| 64 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 65 | S&F for Mild steel work as in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 including cutting etc complete all as specified.including dismantling of existing truss. |
| 66 | S&F for MS as in postsand struts in fencing angle including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron fillets (for securing with mesh etc including all necessary drilling bolting or riveting etc and similar work confirming to Fe-290 (Gde-E-165 quality-B. Note:-Posts/struts of angle iron made to shape shall be welded to existing angle iron bracket of security wall, contractor shall make his own arrangement for welding for boundary wall by using gen sets or any alternative arrangement all as specified and directed by Engr-in-Charge. |
| 67 | Expanded metalweight n .exc 4 kg/sqm , cut to length, Bent to shape required incl welding and tying with and including annealed mild steel wire not less than 0.9 mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified. |
| 68 | M&L preparation of new steel surface and apply two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 69 | Demolition of trellis work(jafri) including taking as under of battens in trellis (post and rails measured separately). |
| 70 | M&L for providing precast cement concrete1:2:4 type B-0 using 12.5mm graded aggregate louvres and jallies, 35mm thick (measured solid), including all mouldingsset in CM 1:4 complete all as specified. |
| 71 | M&L for Pre-Cast RCC (1:1.1/2:3) (12.5 mm graded crushed stone aggregate) as in pillars of any shape, size & design as approved by Engr-in-Charge and making groves for insert of jafri jallies and fixed with existing jallies/ new jallies as inserting with CM 1:3 completed all as specifed and directed by Engr-in-Charge. |
| 72 | S&F Aluminium composite panel sheet 3mm thick of approved make joint with silicon/adhesive as per manufacturer instrction incl with necessary MS framed workas required shape and sized by welding etc in ceiling/coloumns and in vertical surface complete all as specified and directed. Note : 1. Framed work rates shall be inclusive in ACP Rates .2. Colour and pattern of Sheet will be appoved by GE 3.The rates of necessary scafolding and working platform is included in quoted rate and work isto be carried at approximate 10mtr height. |
| 73 | S&F Precast Prefabricated cement concrete column of requred size and shape suitable with proper size channel for fixing of Pre Fabricated RCC wall pannel of requred size as per site requirent including fixing of cloumns to a required depth as per manufacture\"s instruction incl demolition of existing Rcc column/ copping complete all as specified and directedNote : The excavation of post holes, fixing with PCC Type B1- 1:2:4 and making good surface is included in Quoted rates. |
| 74 | S&F Precast Prefabricated RCC Wall panel of 50 mm to 60 mm thick with suitable size fixed properly in prefaricated columns and sealed properly with filling materials as per manufacture instructions incl demolition of existing Precast Prefabricated RCC Wall panel or RCC jallies ,complete all as specified and directed. |
| 75 | S&F Double side writing informatory stainless steel (304 grade) reflecting Sign Boards size 4\"x2.5\" having with Aluminium sheet base of 2mm thickness having retro reflective tape base and colour and matter both side of sign board will be furnished by Engr-in-Charge.The frame of Sign board shall be 30mmX30mm Square stainless steel pipe and having two legs of stainless steel round pipe 6\" to 7\" long Each of 3\"\" outer dia circular pipe the board shall be grouted in PCC work of size 350x350x 450mm including taking down of existing complete all as specified and as directed. |
| 76 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises |
| 77 | M&L for coloured Glazed ceramic tiles in vertical surface 450x300X7mm or 600X300X7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match on 10 mm thick backing coat in CM 1:4 complete all as specified and directed. |
| 78 | M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM 1:4 complete. |
| 79 | M&L for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchover 15 mm thick screed bed in CM 1:4 complete. |
| 80 | M&L for Parking tile/Out Door coloured ceramic tiles 8 to 9 mm thick (square/rectangular) area of each tiles exceeding 0.06sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified |
| 81 | S&F in repair one piece square model water closet floor mounted Square Commode (White) S trap - white ceramic western commode (white) shape-Elongated type,size 685x360x720mm weight not less 20 Kg \"S\" trap and slim seat cover & fittingas per Cera Cat Part No S1013164 or equivalent complete all as specified and directed by Engr-in-Charge. |
| 82 | S&F in repairbib taps 15mm bore long body (for iron pipe) cast copper alloy fancy type chormium plated butter fly handle screwed down completeall as specified and as directed by Engineer-in-Charge. |
| 83 | S&F factory made WPC jali combining WPC board/Fancy designer type grating and WPC frame 100% solid WPC (wood polymer composite) railing of required length and of 2\" to 2.5\" height , comprising of virgin PVC resin of K value 58-60 (Suspension Grade) , Calcium Carbonate and natural fibres (Wood Powders/rice husk//wheat husk) and non toxic additives, made from single extrusion process, WPC foam board with having minimum density 650kg/cbm and WPC frame having minimum density 780kg/cbm manufactured by an ISO 9001-2015 certified Company, having good screw holding capacity (screw withdrawal strength of 2000N (Face) & 1100N (Edge) , Minimum comprising of 50N/mm2, Modules of elasticity 850N/mm2 and resistance of speed of flame of class A category with property of being termite/Borer free water /Moisture proof and fire resistance. For WPC railing WPC jali to be fixed with WPC frame of size 75x50mm with necessary supporting lengths at vertical as well as horizontal at wall frames to be fixed with 3\"x3\" GI \"L\" or SS cleats to support vertical frame lengths including demolition / dismantling of existing WPC or RCC jallies with frames complete all as specified and as directed. (Make : Rajshree or equivalent as approved by GE) (Note : The said item shall be fixed over boundary walls/roof tops and in any other positions as per requirement at site and cost of frame is included in the quoted rates) |