|
| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils in soft/loose soil complete all as specified and directed. |
| 3 | Removing excavated material exc 250 m but not exc 500 m and depositing where directed all as directed complete all as specified and directed. |
| 4 | M&L forPCC type D2 ,1:4:8 (Using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 5 | S&F TMT Bars 10mm dia and over, cut to length, bent to shape required, inculding cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 6 | Ditto all as per item No 5.00 here-in-before above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed. |
| 7 | Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and directed. |
| 8 | M&L for RCC (nominal mix) type A1 1:1.5:3 (using 20mm graded stone aggregate)in foundations, including rafts, footings, foundation beams; plinth beams; bases for coloumns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 9 | Use and waste of form work to sides of pillars, posts, struts,piers, columns and stanchions for rough finished flat surfaces of concrete, square, rectangular or polygonal, complete all as specified and directed. |
| 10 | M&L for RCC (nominal mix) type A1 1:1.5:3 (using 20mm graded stone aggregate)in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 11 | Use and waste of form work to side and soffits of floor or roof beams, beam haunchings,girders, bressummers, lintels beam,tie beam, cantilevers, shelves including supports, overhangs, etc. also splays between floors and rough finished, complete all as specified and directed. |
| 12 | M&L for RCC (nominal mix) type A1 1:1.5:3(using 20mm graded stone aggregate)in Beams, cantilevers, bressummers,tie beam,lintelsover 1.5m span complete all as specified and directed. |
| 13 | M&L for hardcore of gauge not exceeding 63 mm of broken stone, deposited, spread and leveled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 14 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parkingetc.,of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 15 | M&L for Pre-cast cement concrete block masonry with solid blocks type C1, 1:3:6 ( 20 mm graded aggregate) exc. 10 cm in width and setting in mortar 1: 6 ,complete all as specified and directed. |
| 16 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smoothwithout using extra cement. including mixing of water proofing compound wherever required as per manufacturers instructions complete all as specified and directed.(Note: WPC shall be measured & paid separately). |
| 17 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces incement mortar 1:6, finished even and smooth with out using extra cement complete all as specified and directed. |
| 18 | Dismantling structural steel work of any description and any position including doors, gate,fencing,framed trusses complete all as specified and directed. |
| 19 | Dismantling Plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 20 | S&F mild steeltubulartrussed, purlins, fencing posts,crane gantries rails and fastenings including special shaped washer etc complete using ERW or induction butt welded tubes Conforming to IS 1161-1979 grade St -240 including distance pieces, cleats , nut & bolt any size & length complete all as specified and directed. |
| 21 | S&F Mild steel Plates (plain or chequered) Fe-410- W(Gde-E-250)quality B channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed. |
| 22 | S&F Mild steel screw bolts diameter of neck in 12mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,exc 5cmn exc 10cm long complete all as specified and as directed. |
| 23 | S&F Mild steel flats (40x6mm thick)forhand rails, wind ties, posts and struts in fencing screwed or welded to shape as directed, including all necessary drilling, bolting or riveting etc., and similar work confirming to Fe 410-O or Fe 310-O complete all as specified and as directed. |
| 24 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheeting 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws/J hooks and bolts as reqd and the sheets shall be crimped to desired shape complete all as specified and as directed.Note: The rate quoted shall be inclusive of crimping as required on site. |
| 25 | M&L Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 26 | S&F Gl frame work for seamless ceiling including provision of 10 mm th Gypsum ceiling board comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and as directed. |
| 27 | S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed. |
| 28 | M&L for two coats of Distempering on wall with distemper oil emulsion white or tinted over primer over a coat of 3mm thick wall care putty, including preparation of new surface all as specified. |
| 29 | S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed. |
| 30 | S&F 19mm thick plywood 7 ply with BWR type BB, fixed with adhesive and screws for top, bottom and sides ofworking table / shelves/ wall mounted shelvesof any shape to required size, pattern/design,including necessary fixing to wall with necessary fixing bolts and accessories for wall mounting and floor bush for work stations complete all as specified and as directed. |
| 31 | S&F 0.90mm thick decorative laminate type I of surface finish(colour & pattern as approved) fixed with approved adhesive as per manufacturers instruction finished to approved size forworking tables/ shelves/ wall mounted shelvesof any shape of any pattern and design etc complete all as specified and as directed. |
| 32 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dresses stonework and precast concrete articles complete all as specified and as directed. |
| 33 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 34 | M&L Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of cement mortar 1:6 complete all as specified and as directed. |
| 35 | All as per item No 34.00 here-in-before but as in skirting over and including 10mm thick rendering on brick work or concrete surfaced wall as backing coat of cement mortar 1:4 complete all as specified and as directed. |
| 36 | M&L for 50mm thick Cement concrete type B1, 1:2:4 (40mm graded stone aggregate) as in flooring, foot path, hard standing, plinth protection, bases of water tanks etc complete all as specified and as directed. |
| 37 | M&L for 75 mmthick PCC 1:2:4 type B1 (using 20 mm gradedstone aggregate) including finishing the surface even and fair complete all as specified and directed. |
| 38 | M&L for coloured designed chequered cement concrete tiles of a size 300x300x25mm thick withwhitecement & pigment in floorsetc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including a 20 mm thick screed bed of cement mortar 1:6 complete all as specified and directed. |
| 39 | M&L for coloured non skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding. 0.18 sqm, in floors etc. set and jointed in neat cement slurry over and including a 15 mm thick screed bed of cement mortar 1:6 and pointed with white or coloured cement to match complete all as specified and as directed. |
| 40 | M&L for Coloured Glazed ceramic design tiles 350x 250x 7mm/450X 300X 7mm thick, on vertical surfaces such as skirting, dados and risers to stepsetc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and as directed. |
| 41 | S&F 110 mm dia PVC SWR pipes single socketed, in any length with rubber ring joints,laid in trenches orfixed with floor including necessary fixing cleats/ clamps, complete all as specified and directed. |
| 42 | S&F in repairs 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed with wall including necessary fixing cleats/ clamps complete all as specified and directed. |
| 43 | S&F in repairs PVCbends of 110 mm dia complete all as specified and directed. |
| 44 | S&F in repairs PVC bends of 75 mm dia complete all as specified and directed. |
| 45 | S&F Rotational moulded polyethylene water storage tanks of white colour triple layered (ISO certified) (cylindrical vertical with closed top ) hoisted and fixed in positionall as specified in Sch “A”of capacity 1000 liter, including 20 mm bore Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified. |
| 46 | M&L for 20mm thick Granite of any type work (table rubbed and polished) in cooking plateform, widow sill, step, wall lining and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade granite over andincluding a15mm thick screed in cement mortar 1:6 complete all as specified and as directed.. |
| 47 | Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed. |
| 48 | Complete removal of existing treatment and M&L for preparation of old surface and applyingtwo coats of Distempering wall with distemper oil emulsion white or tinted through mechnical means over a coat of 1mm thick wall care putty complete all as specified and directed. |
| 49 | Complete removal of existing treatment of walls and applying two coats of exterior emulsion paint (weather coat) through mechnical means over a coat of approved primer complete all as specified and directed. |
| 50 | Complete removal of existing treatment and preparation of old painted surface of any description not otherwise described wood and wood based surfaces over 10 cm width of girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 51 | M&L for preparation of old decorated surface of ceiling including washing, rubbing down and stopping of distempered and painted surfaces and applying one coat of distemper oil emulsion through mechnical means on ceiling complete all as specified and directed. |
| 52 | S&F 20 mm diaUPVC pipe of pressure rating 10 Kgf/cm2 with all fittings and fixed to wall /laid in floor complete all as specified and as directed. |
| 53 | S&F25 mm dia UPVC pipe ofpressure rating 10 Kgf/cm2 with all fittings and fixed to wall /laid in floor complete all as specified and as directed. |
| 54 | S&F in repairs table top wash basin ofsize 565X425X140mm ,white colourof Jaquar makeCat No-KUS-WHT 35935/ JDS-WHT-0547 complete all as specified and directed. |
| 55 | S&F in repairs premium quality 15mm pillar tap with wall flange chromium plated, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 56 | M&L for clay moulded terracota jalli blocks of intricate design, patterns and shapes , kiln burnt, size of each block 220x220×63 mm, binded using approved adhesive, fixed to mild steel frame work as required and colouring the tiles with terracota shade for aesthetic appearance complete all as specified and directed.Note:- Mild steel work shall be measured and paid separately. |
| 57 | M&L for point wiring with 1.5 sqmm PVC insulated,unsheathed, FRLS multistrandedcopper conductor 1100 volts grade cable in and including heavy grade PVC Casing & CappingISI markedbroken white or of cream colour with all accessories such as tee,bend,joint cover etc, round/ square PVC blocks at junction for batten holders, ceiling rose etc ,screws, gutti / roul plugs PVC all as per site requirementsincluding fixing on stone walls / brick masonary walls /ceilings /floors etcmodular MS sunken boxes with earth dollyfor mounting of modular switches/ sockets/regulator etc and 1.5 sqmm PVC insulated,unsheathed, FRLS multistrandedcopper conductor 1100 volts grade cableas continuous earth lead connected to common earth dolly complete all as specified and colour coding of cables such as Phase- Red, Neutral-Black, and Earth-Green.and making good to disturbed surfaces/wall with plaster& matching with the existing colour of wall/floor etc complete all as specified & directed for the following :- |
| 58 | One light point controlled by one single pole 5 Amps switch. |
| 59 | One ceiling fan/wall fan point controlled by one single pole 5 Amps switch. |
| 60 | One 5 pin socket point 5 Amps on independent board. |
| 61 | One 5 pin socket point 5 Amps on same board with other switches. |
| 62 | All as per item 57.00 here-in-before but for power point wiring with 2.5 SqmmPVC insulated, unsheathed, FRLS multistranded copper conductor 1100 volt grade cable and 2.5 SqmmPVC insulated, unsheathed, FRLS multistranded copper conductor 1100 volt grade cable as continuous earth lead for 6 pin 15 Amp switch socket outlet onindependent board complete all as specified & directed. |
| 63 | S&F Modular switch , 1 Module single pole one way10 Amps complete all as specified & directed. |
| 64 | S&F Modular socket , 2 Module6 Amps, 5 pin, 230 volts AC complete all as specified & directed. |
| 65 | S&F Modular switch , 1 Module single pole one way16 Amps complete all as specified & directed |
| 66 | S&F Modular socket , 2 Module6/16Amps, 6 pin, 230 volts AC complete all as specified & directed. |
| 67 | S&F Modular white cover plate with frame, 3 module complete all as specified and directed. |
| 68 | S&F Modular white cover plate with frame, 6 module complete all as specified and directed. |
| 69 | S&F Modular white cover plate with frame, 8 module complete all as specified and directed. |
| 70 | S&F Modular metal flush box 3 module complete all as specified and directed. |
| 71 | S&F Modular metal flush box 6module complete all as specified and directed. |
| 72 | S&F Modular metal flush box 8 module complete all as specified and directed. |
| 73 | S&FPVC ceiling rose 65 x 50 mm surface type with 3 terminals 230 volt complete all as specified & directed. |
| 74 | S&F LED Light fitting, 4 feet1x20 Watts, 220 volts, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of size 1.5 sqmm from ceiling rose complete all as specified & directed. |
| 75 | S&F LED mirror Light fitting 2 feet, 10 Watts, 220 volts, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable ofsize 1.5 sqmm from ceiling rose complete all as specified & directed. |
| 76 | S&F LED light fitting of size600 mm x 600 mm, 36 watt, white/warm white as per site requirement220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor wire of size 1.5 sqmm complete all as specified & directed. |
| 77 | S&F LED light fitting outdoor type 10 wattbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed. |
| 78 | S&F LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose includingbrackets made out of 50 mm dia light grade GI pipe 1.50 mtr long bent to shape and size as per site requirement for fixing ofstreet light fitting on poles/ walls including Flat Iron clamps=02 Nos of size 30x5mm made to shape incl nuts,bolts & washerscomplete all as specified & directed. |
| 79 | S&F BLDC ceiling fans complete with blades, down rods, electronic regulator and accessories, AC single phase 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE Five star rated with brushless direct current motor (BLDC) and remote system to control all the function of fan complete all as specified & directed . |
| 80 | S&F Sheet metal enclosure for DB\"s double door VTPN 04ways including 01 No MCCB 125 Amp 4 pole 25 KAto be used as incomer and outgoing as MCB single pole, deep drawn with 200 Amps rated copper bus bar 415 V, complete all as specified & directed. |
| 81 | S&F Sheet metal enclosure for DB\"s double door SPN, 8 ways when MCBs to be used single pole and neutral, with 200 Amps rated copper bus bar 230Volt, complete all as specified & directed by Engineer-in-Charge. |
| 82 | S&F Sheet metal enclosure for DB\"s double door SPN, 12 ways when MCBs to be used single pole and neutral, with 200 Amps rated copper bus bar 230 Volt, complete all as specified & directed. |
| 83 | S&F MCB SPN, 40 Amps, 230 V, C- series with breaking capacity of 10 KA complete all as specified & directed. |
| 84 | S&F MCB SP, 6-32 Amps, 230V, C- series with breaking capacity of 10KA complete all as specified & directed. |
| 85 | M&L for sub main wiring with two single core 2.5 sqmm PVC insulated ,unsheathed , FRLS multistrandedcopper conductor 1100 volts grade cable in and including heavy grade PVC Casing & CapingISI markedbroken white or of cream colour with all accessories such as tee,bend,joint cover etc, screws, gutti / roul plugs PVC all as per site requirements including fixing on surface on stone walls / brick masonary walls /ceilings /floors etc with 2.5 sqmm PVC insulated,unsheathed, FRLS multistrandedcopper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete and making good to disturbed surfaces/wall with plaster & matching with the existing colour of wall/floor etc all as specified and colour coding of cables such as Phase- Red, Neutral-Black, and Earth-Green complete all as specified & directed. Note-Two runs of 2.5 sqmm single core cable and one run of 2.5 sqmm earth wire including PVCcasing & capping together shall be measured as one unit. |
| 86 | M&L for sub main wiring with two single core 4 sqmm PVC insulated ,unsheathed , FRLS multistrandedcopper conductor 1100 volts grade cable in and including heavy grade PVC Casing & CapingISI markedbroken white or of cream colour with all accessories such as tee,bend,joint cover etc, screws, gutti / roul plugs PVC all as per site requirements including fixing on surface on stone walls / brick masonary walls /ceilings /floors etc with 4 sqmm PVC insulated,unsheathed, FRLS multistrandedcopper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete and making good to disturbed surfaces/wall with plaster & matching with the existing colour of wall/floor etc all as specified and colour coding of cables such as Phase- Red, Neutral-Black, and Earth-Green complete all as specified & directed. Note-Two runs of 4 sqmm single core cable and one run of 4 sqmm earth wire including PVCcasing & capping together shall be measured as one unit. |
| 87 | M&L for sub main wiring with two single core 6 sqmm PVC insulated ,unsheathed , FRLS multistrandedcopper conductor 1100 volts grade cable in and including heavy grade PVC Casing & CapingISI markedbroken white or of cream colour with all accessories such as tee,bend,joint cover etc, screws, gutti / roul plugs PVC all as per site requirements including fixing on surface on stone walls / brick masonary walls /ceilings /floors etc with 6 sqmm PVC insulated,unsheathed, FRLS multistrandedcopper conductor 1100 volts grade cable as a continuous earth wire and connected to common earth dolly complete and making good to disturbed surfaces/wall with plaster & matching with the existing colour of wall/floor etc all as specified and colour coding of cables such as Phase- Red, Neutral-Black, and Earth-Green complete all as specified & directed. Note-Two runs of 6 sqmm single core cable and one run of 6 sqmm earth wire including PVCcasing & capping together shall be measured as one unit. |
| 88 | M&L for Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron wire 4 mm dia as earth lead up to test point with suitable size GI nuts/bolts, washers,check nut and brazed properly up to main board,LT panel etc and adequate quantity of charcoal and salt 15 cm around the earth plate including earth pit in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregates,40mm thick precast RCC cover in 1:2:4 reinforced with 8mm dia TMT bars 3 Nos both way including CI cover 10 mm thick with hingedand frame of angle iron 25x25x6mmwith 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil and including medium grade GI watering pipe 20mm bore with funnel and wire mesh and medium grade GIprotection pipe 15 mm bore up to main board complete all as shown in electrical plate no 3 of MES schedule Part-I , connected to earthing testing point and testing on completion complete all as specified and directed.Notes: (i) The unit rate includes 15 mm dia GI pipe up to 7.5m for protection of earth lead. (ii) The unit rate includes galvanised iron wire 4 mm dia from earth electrode to test point up to 7.5 meter (iii) In case measured value of earth resistance of each earthingis recorded more than 3 ohms then the earthing shall be re done by the contractor without any extra cost to the Govt till desired result is obtained (iv) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge / JE E/M and proper record shall be maintained duly signed by all concerned. (v) Earth resistance tester will be provided by the contractor. It should be caliberated from authorised company/ lab. |
| 89 | S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing 4 mm dia galvanised iron or steel wire complete all as specified and directed. |
| 90 | Taking down carefully ceiling fan from ceiling,painting of ceiling fans complete, with one coat of synthetic enamel paint by spraying including filling cavities with filler, cleaning all dust etc. and refixing of ceiling fan in same position in serviceable conditionincluding provision of three core 1.5 sq mm cable from ceiling rose to fan connector complete all as specified and directed. |
| 91 | Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting pointcomplete all as specified and directed. |
| 92 | M&L for sand cushioning to under ground cable with locally available dry sand for protection of cable 8cm thick before laying of cable and 15 cm thick after laying and stretching the cable below the bricks/PCC cover ,punning of sand using suitable T&P as per site requirementcomplete all as specified and directed. Note- Punned thickness of sand i.e 18 cm shall be considered for measurement purpose. |
| 93 | Supply and laying un-reinforced precast concrets cable cover class LV, Type 1, flat, size 250x150x40 mm complete all as specified and directed. |
| 94 | S&F LED post-top light fitting 25 watts made in die-cast aluminium bottom housing and spun aluminium top reflector with decorative clear acrylic diffuser and IP 65 protection withLED light completeall as specified & directed . Make: Bajaj BGCTN 25 W LED WW or tehcno-commercially equivalent of Havells,CG. |
| 95 | Supply and laying in trenches /laid in floor/duct/drawn through conduit XLPE insulated,screened, PVC bedded, galvanized steel strip or wire armouredheavy duty electric cable 1100V grade with aluminum conductor of cross sectional area10 sqmm 2 core connecting with panel,DB with suitable size lugs complete all as specified and directed. |
| 96 | M&L for 50 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, includingnew Flat Iron clamps=02 Nos of size 50x6mm made to shape incl nuts,bolts & washers complete all as specified and directed. |
| 97 | S&F with pole/wall/pillar PVC cable loop box, size not less than 200 mm x 140 mm x 95 mm, out door type, IP 65including 4 Nos aluminum connector mounted on porcelain insulators with oneMCB SP 6 amps 230 volts connected to street light/gate fitting sub main wire and usingFI clampsof size 20mm x3 mm for fixing of PVC cable loop boxwith pole,including nuts,bolts & washers and connecting thecables to bus bars withusing suitable size GI nut, bolts and washers and aluminum lugs etc andcomplete all as specified & directed. |
| 98 | S&F copper flexible cable three core of size 1.5 sqmm PVC FRLS insulated and sheathed 1100 volts grade including 20 mm dia PVC conduit heavy dutycomplete all as specified & directed. |