| 1 | Demolition of brick work stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified. |
| 2 | M&L for brick work with old size bricks, straight or curved on plan n.exc 6m mean radius, built in cm 1:6 complete all as specified and directed. |
| 3 | M & L for except brick work with sub class \"B\" brick straight or curved on plan exc 6m mean radius with old size bricks in CM 1:6 complete all as specified and directed. |
| 4 | Taking down cement mortar plastering on brick or stone walls, etc. including raking out joints,hacking for key,scrubbing down with water, etc. |
| 5 | M&L for 15mm thick rendering on fair faces of brick/ concrete surfaces in CM (1:6) finished even and smooth without using extra cement mixed with water proofing compound. |
| 6 | M&L for two coats of cement base paint over chalk whitening newly plastered surfaces of walls including preparation of surfaces all as specified. |
| 7 | Dismantling of posts or struts(wood, steel or RCC) any section embadded in concrete, including taking out embedded portion and making good disturbed groundall as specified anddirected. |
| 8 | Dismantling of fencing wire mesh of any type complete all asspecified and directed. |
| 9 | Dismantling ofsteel barbed wireof any type complete all asspecified and directed. |
| 10 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard dense soil. |
| 11 | M & L for cement concrete Type D2 1:4:8using40 mm graded stone aggregatein foundations, filling and mass concrete complete all as specified. |
| 12 | S & F in repairs galvanized 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing & straining & fixing to any type of standards rails straining bolts including securing or tying at crossing with & provn of galvanized mild steel wire complete all as specified anddirected. (Each line wire to be measured) |
| 13 | Supply only 10mm dia MS Round bars as in support of Chain Link Fencing all as specified. |
| 14 | Supply only chain link MS galvanized fencing of any size or type complete all as specified anddirected. |
| 15 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provission of binding wire |
| 16 | S & F mild steelbolt screwed one end with hexagonal or square nuts & washers the other end enlarged not exc 15cm long dia of neck 12mm complete all as specified anddirected. |
| 17 | M&L for posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 all as specified anddirected. |
| 18 | M&L for preparation of new steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enameled paint over a coat of red oxide primer all as specified and directed. |
| 19 | M&L for Providing, cement concrete type B1 1:2:4 using (20mm graded stone aggregate), in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses,lacing courses,parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs not provided for water troughs and the like including weathering, slightly rounded or chamfered angles and throating, all complete all as specified and directed |
| 20 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified anddirected. |
| 21 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for .Note- Rate includes for reinforcement cutting as required to facilitate demolition. |
| 22 | M&L for providing RCC (1:2:4) using 20mm graded stone aggregate as in coping, slab supported on wall, beam, lintels etc complete all as directed by Engrin charge. |
| 23 | M & L for Providing prestress precast ce- ment concrete1:2:4 type B0 in columns, posts, boundary pillars, with plain fair faces, including chamfers, weatherings, throat- ing etc. complete with joints to match as directed by Engr in charge.Note: (i)The quoted rate shall be inclusive of cost ofhigh tensile carbonized steel wire dia 3 to 4mm reinforcement , and Form work complete. (ii) Before plaing bulk order inspection of factory site shall be carried out by rep of GE for approval. |
| 24 | S&F for50 mm thick prestress precast cement concrete1:2:4 type B0 as in compound wall Modular(both Side Finish), planks/panels lockingeach otherdesign/patterns as approved by EIC ,complete all as directed by Engr in charge.Note: (i) The quoted rate shall be inclusive of cost ofhigh tensile carbonized steel wire dia 3 to 4mm reinforcement ,and Form work)(Note:columns/ poles will be measured seperately) (ii) Before plaing bulk order inspection of factory site shall be carried out by rep of GE for approval. |
| 25 | S&F for 50 mm thick1:2:4 type B0 precast cement concrete compound wall plain planks/panels lockingeach other design/patterns as approved by EIC complete all as directed by Engr in charge.Note: (i) The quoted rate shall be inclusive of cost of reinforcement , Form work)(Note:columns/ poles will be measured seperately)(ii) Before plaing bulk order inspection of factory site shall be carried out by rep of GE for approval. |
| 26 | M & L for 75 mm thick Cement concrete type C-2, 1:3:6 using(40 mm graded stone aggregate ) as in Plinth protection. |
| 27 | Supply and fix for framed work as in doors or gates of angle or other section with gusset Plate, rails,braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges and door fittings necessary rivetting/welding cutting up complete steel conf. toFe 410-W (Gde- E- 250) quality- A all as specified and directed.Note : Distrubed surfaces of wall shall be made good to true surface. |
| 28 | Dismantling structural steel work including doors, gates but excluding framed trusses complete all as specified anddirected. |
| 29 | M&L for Glazed ceramic coloured tiles of size. 300x450x7mm thick on vertical surfaces of walls such as skirting dado etc over 10mm thick backing coat in CM 1:4 and jointed in neat cement slurry and pointed in white or coloured cement to match complete.incl taking down of existing plaster/tiles/granite |
| 30 | M & L forArtificer Granite (of any type) 12-15mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting andpolishing typesover 10mm thick screed bed in CM 1:4 and jointed in neat cement slurry and pointed in white or coloured cement to match complete. incl taking down of existing plaster/tiles/granite |
| 31 | M & L forfactory made prepolished chequered cement concrete tiles 30cm x 30cm x 25mm thick Rubber moulded with grey cementandpigment, including 15mm thick screed in CM 1:6, set jointed & pointed in neat cement slurry in floors complete all as specified anddirected. |
| 32 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade as in floor/pavement with grey cement and pigment complete all as specified and as directed. |
| 33 | M&L for 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour,design & pattern as in footpath,parks,lawn ,drive ways or light traffic parking etc,of reqd strength thickness & size/shapemade by table vibratory method using PU mould laid in reqd colour & pattern over and including 50mm thick compacted bed of coarse sand,compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator,filling the joints with fine sand and cutting of paver block as per reqd size and pattern,finishing and sweeping extra sand complete. |
| 34 | M & L for Sand filling under floors or in foundationincluding watering and consolidation complete. |
| 35 | M&L for precast perforated drain cover slab RCC (1:2:4), type B1 using 20mm graded crushed stone aggregate and incluidng placing & set in CM 1:6, complete, (Size of cover 0.60x0.60mm) and 75mm thick all as specified . |
| 36 | M&L for precast perforated drain cover slab RCC (1:2:4), type B1 using 20mm graded crushed stone aggregate and incluidng placing & set in CM 1:6, complete, (Size of cover 0.60x0.75mm) and 75mm thick all as specified . |
| 37 | M&L for precast perforated drain cover slab RCC (1:2:4), type B1 using 20mm graded crushed stone aggregate and incluidng placing & set in CM 1:6, complete, (Size of cover 0.60x1.00mm) and 75mm thick all as specified . |
| 38 | Taking down and refixing of same opening of steel gate of any size including repair to pintle hinges,welding if required,Scafholding and cutting etc carriying out any other activity necessarty to make gate funcctional.(Note: The quoted rate shall be inclusive of cost ofPintle hinges,welding, Form work comolete. |
| 39 | S & F 10mm dia TMT bars and over cut to lengthbent to shape required including craking bending, spirally for hooping for columns, hooking ends and binding with mild steel wire ( annealed) not less than 0.90mm dia of wire or secruing with clips all. |
| 40 | All as sr. item No. 39 above but 5mm dia and over upto and including 10mm diain stirrups, spacers and binders, spaces etc complete all as directed. |
| 41 | Dismantling of PVC pipes 100/75 mm bore all as specified and directed. |
| 42 | S&FPVC (SWR) pipe110 mm bore single socketed in any length with rubber ring jointed levelfixed to walls complete all as specified anddirected. |
| 43 | S&F PVC (SWR) pipe75 mm bore single socketed in any length with rubber ring jointed levelfixed to walls complete all as specified anddirected. |
| 44 | S&F PVC (SWR) bends 110 mm bore complete all as specified anddirected. |
| 45 | Ditto all as per sr. item No 44 above but 75 mm bore |
| 46 | S&F for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as directed. |
| 47 | Dismantling of asbestos cement (corrugated, semicorrugated, etc.) sheets/any type of sheet in roof coverings including ridges etc complete all as specified and directed. |
| 48 | S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of anycolour (shed/Gazebo) having tensile strength of 550 Mpa as in roof covering including ridges /cladding to wall,fixed with self tapping screws as specified and directed. |
| 49 | S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of anycolour having tensile strength of 550 Mpa as in roof covering including ridges /cladding to wall,fixed with self tapping screws as specified and directed. |
| 50 | M & L for cement concrete Type C2 1:3:6using40 mm graded stone aggregatein post holes, filling and mass concrete complete all as specified. |
| 51 | Excavating in trenches, n.exc 1.5m wide and n.exc. 1.5m in depth for foundation, etc. or for shaft, wells and cesspits in soft/loose soil all as directed. |
| 52 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm all as directed. |
| 53 | Removing excavated materialbut n.exc 50 m and depositing where directed |