| 1 | Schedule \"A\" B/R |
| 2 | Excavation in post holes (or similar holes) each not exceeding 0.50 cum getting out, returning, filling & ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm. watering and removing surplus soil to a distance not exceeding 50 mtr in hard/dense soil, Complete all as specified and directed by Engineer-in-Charge. |
| 3 | Material & Labour for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in fdn, filling & mass concrete, Complete all as specified and directed by Engineer-in-Charge. |
| 4 | Supply & Fixing steel work in tubular trusses including special shaped washer etc., complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240, Complete all as specified and directed by Engineer-in-Charge. |
| 5 | Material and labour for painting two coat of steel surfaces with synthetic enamel paint over one coat of red oxide primer including prep of surfaces, over 10cm in width or girth, not otherwise described, Complete all as specified and directed by Engineer-in-Charge. |
| 6 | Supply & Fixing pre-painted galvalume aluminium zinc coating GI based corrugated steel sheeting 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws/J hooks and bolts, Complete all as specified and directed by Engineer-in-Charge. |
| 7 | Excavation in trenches, not exceeding 1.5 Metre wide and not exceeding 1.5 Metre depth for foundation, laying of pipe line, etc., and getting out in soft/disintegrated rocks, Complete all as specified and directed by Engineer-in-Charge. |
| 8 | Material & Labour Plain Cement Concrete Type D-2 1:4:8 (using 40mm graded granite stone aggregate) in foundations, filling and mass concrete, Complete all as specified and directed by Engineer-in-Charge. |
| 9 | Material & Labour for Pre-cast cement concrete block masonry type C-1, 1:3:6 (20mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:4, Complete all as specified and directed by Engineer-in-Charge. |
| 10 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils, Complete all as specified and directed by Engineer-in-Charge. |
| 11 | Removing Excavated soils not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point, Complete all as specified and directed by Engineer-in-Charge. |
| 12 | Material & Labour for rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:4 and even and smooth without using extra cement, Complete all as specified and directed by Engineer-in-Charge. |
| 13 | Dismantling of floor, hearth or wall tiling, including cement mortar bedding (but not backing) and rubbish off the premises including removal of debris to a distance exceeding 1.5 but not exceeding 2.00 km, Complete all as specified and directed by Engineer-in-Charge. |
| 14 | Demolition of cement concrete (unreinforced) in ground floors and paving’s not exceeding 15 cm thickness (below or above G.L), Complete all as specified and directed by Engineer-in-Charge. |
| 15 | Material & Labour for 25mm thick cement concrete type B-0, 1:2:4 (using 12.5mm graded aggregate) as in levelling course in flooring, Complete all as specified and directed by Engineer-in-Charge. |
| 16 | Material & Labour for Heavy duty Exterior floor tiles 16mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 20mm thick screed bed or bedding layer with 1:6 cement Mortar, Complete all as specified and directed by Engineer-in-Charge. |
| 17 | Supply and fixing fabrication of stainless steel (tubular sections) gates of grade 304 including gate rollers, guides, tracks, stoppers, locks, handles, hinges, drop bolt/ground bolt and all other necessary fittings required for sliding / openable gate with bright finish, Complete all as specified and directed by Engineer-in-Charge.Note:-Type of tubular section height, width of Gate pintol hinges and alike complete will be all as directed by GE at site. |
| 18 | Material & Labour for granules textured homogeneous wall finishing system consisting of a two component system of dry granules (25 Kg per Pack) made of 92% silica particles coated with fade resistant pigment, 100% acrylic polymer bonding agent (5 Kg per pack) with the applied thickness of the coating being between 0.8mm -1.2mm to be applied on curved, smooth level plaster without key, as per manufacture directions, for usages to be applied and approved applicator of the manufacture as per the direction/ supervision of the Engineer-in-charge, all complete. The above textured coating should conform to surface spread of flame class one of BS 476:Part 7:1971 and pull off strength of the coating to meet JISA 6909 on smooth plastered surfaces, Complete all as specified and directed by Engineer-in-Charge.Make:- Bakelite Hylam Limited or equivalent make approved by the GE. |
| 19 | Material & Labour for Preparation of new plastered surfaces of walls and applying two coats of acrylic emulsion exterior grade over a coat of primer, including all necessary scaffolding etc., Complete all as specified and directed by Engineer-in-Charge. |
| 20 | Material & Labour for Cutting opening in cement concrete walls (any description)for door, window and other openings (with or without reveals) or enlarging existing openings, including trimming surfaces to receive rendering, etc., Complete all as specified and directed by Engineer-in-Charge. |
| 21 | Material & Labour for 1.5mm thick Decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer\"s instructions on 18mm thick calibrated plywood of grade BWR, type BB, fixed with screws to timber frame work, Complete all as specified and directed by Engineer-in-Charge. |
| 22 | Material & Labour for preparation of new plastered surfaces of walls, providing one coat 3mm of Birla white wall care putty to achieve smooth surfaces and applying two coats of Oil Bound Distemper of approved shade/tint over a coat of compatible priming paint, Complete all as specified and directed by Engineer-in-Charge.Make: Asian Paints/Berger/Shalimar Paints. |
| 23 | Supply & Fixing MS bands, straps, hooks, clamps, holdfast and similar small articles conforming to Fe-290-O Gde E-165, Complete all as specified and directed by Engineer-in-Charge. |
| 24 | Supply & Fixing Electric Chimney of stainless steel, wall Mounted hoods 90cm long, having convertible operating mode with max air circulation at the rate of 353 cum/hr and touch control setting model no. DWB98JR5OI, multi-layer cassette filters, auto clean steel/Grey, Complete all as specified and directed by Engineer-in-Charge. |
| 25 | Supply & Fixing in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm and fixed with stainless steel wire stapels including old or new beading, Complete all as specified and directed by Engineer-in-Charge. |
| 26 | Supply & Fixing PVC (SWR) 150mm bore pipes single socketed in any length with rubber ring joints and accessories fixed wall, Complete all as specified and directed by Engineer-in-Charge. |
| 27 | Supply & Fixing PVC (SWR) bends 150mm, Complete all as specified and directed by Engineer-in-Charge. |
| 28 | Supply & Fixing PVC (SWR) vent cowl 150mm, Complete all as specified and directed by Engineer-in-Charge. |
| 29 | Schedule \"A\" E/M |
| 30 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sqmm 4 core, Complete all as specified and directed by Engineer-in-Charge. |
| 31 | Supply and Laying, 32mm OD Double Wall Corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall for protection of underground Cable with all fittings, Complete all as specified and directed by Engineer-in-Charge. |
| 32 | Material & Labour for Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multi-stranded copper conductor FRLS cable 1100 Volts grade drawn through and including PVC heavy dutyconduit (minimum 20mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked including conduit accessories like bends, tees, junction boxes etc., fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multi-stranded copper conductor FRLS cable as earth continuity wire including modular metal flush box with cover plate and frame of required modules for mounting of modular switches, sockets and fan regulators, complete all as specified and directed by Engineer-in-Charge. for the following:- |
| 33 | For One light point /fan point controlled by one switch with cable 1.5 Sqmm |
| 34 | For one 3 pin socket outlet 5 Amps independent board withcable 1.5 Sqmm nominal area |
| 35 | Material & Labour for Point wiring complete with 2.5 sqmm single core PVC insulated but unsheathed multi-stranded copper conductor FRLS cable 1100 Volts grade drawn through and including PVC heavy duty conduit (minimum 20mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked including conduit accessories like bends, tees, junction boxes etc., fixed concealed/ recessed in wall or ceiling etc., including 2.5 sqmm PVC insulated but unsheathed multi-stranded copper conductor FRLS cable as earth continuity wire includingsunken type pressed steel terminal boxes of suitable size with 2.8mm thick Bakelite sheet white/coloured top cover for mounting of modular switches, sockets and fan regulators, complete all as specified and directed by Engineer-in-Charge. for the following:-(a) one 3/5 pin 15/16 Amps socket |
| 36 | Supply & Fixing Modular switch 1 way, 10 Amps, 1 module, complete all as specified and directed by Engineer-in-Charge. Make: Legrand (Arteour) / Schneider (zencelo) / hager (berker) |
| 37 | Supply & Fixing Modular switch 1 way, 16 Amps, 1 module, complete all as specified and directed by Engineer-in-Charge. Make: Legrand (Arteour) / Schneider (zencelo) / hager (berker) |
| 38 | Supply & Fixing Modular socket, 6 Amps, 2/3 pin combined 2 module, complete all as specified and directed by Engineer-in-Charge. Make: Legrand (Arteour) / Schneider (zencelo) / hager (berker) |
| 39 | Supply & Fixing Modular socket, 6/16 Amps, 2/3 pin combined 2 module, complete all as specified and directed by Engineer-in-Charge. Make: Legrand (Arteour) / Schneider (zencelo) / hager (berker) |
| 40 | Supply & Fixing 6 Amp, 250 V high quality robust surface/ flush type polycarbonate/ PVC ceiling rose, conforming to IS: 371- 1979, having 2/3 terminals and outside diameter not less than 63.5mm, complete all as specified and directed by Engineer-in-Charge. |
| 41 | Supply & Fixing Polycarbonate thermoplastics Vertical TPN distribution board in accordance with IEC 61439-3 which should be shock proof, Protection Class-I, earthed. IP66 in accordance with IEC 60529 (EN60529), weather proof, Corrosion free, Acid & Chemical Resistant, Impact resistant, Ultra Violet resistance according to IEC61439- 1, made of halogen & Silicone free recyclable material, internally embedded gasket with provision for cable entry through integrated flanges top and bottom with removable side walls, Impact strength IK 08 (5 joules) in accordance with IEC 62 262, should withstand Glow wire test at 960°C in accordance with IEC 60695-2- 11 flame retardant, Self Extinguishing, UL subject 94,V-2. Color: Grey, RAL 7035. VTPN DB should assembled by OEM and should pass all test or submit test copy also, complete all as specified and directed by Engineer-in-Charge. |
| 42 | Supply & Fixing of 22 Watt LED extruded aluminium batten luminaire, nominal lumen output 2000 lm, IP20, voltage range 140-270 volts PF>0.9, wall mounted, complete all as specified and directed by Engineer-in-Charge. Make: Philips Cat Part:BN 021 LED40S- 6500 PSU GR (4 ft) or equivalent in Wipro/Crompton Greaves or equivalent make mentioned in Appendix \"B\". |
| 43 | Material & Labour wall mounted fan of size 400mm sweep, maximum speed 1350 RPM, 65 watt, built in thermal overload protector, 100% copper motor, maximum air flow 65CMM, oscillation with number of speed 3 operating voltage 220-240 V and frequency 50 Hz of sizes 295mm(H) x 220mm(L) x 155mm(W) and electrical connection with 3 core flexible copper conductor cable of appropriate size from ceiling rose to the wall mounted fan, Complete all as specified and directed by Engr-in-Charge.Make:- Bajaj/ Havells / Usha / Orient or equivalent make mentioned in Appendix \"B\". |