| 1 | Schedule \"A\" |
| 2 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor, complete all as specified and directed by Engineer-in-Charge. of following size:- |
| 3 | 120 sqmm 3.5 core |
| 4 | 50 sqmm 3.5 core |
| 5 | 25 sqmm 4 core |
| 6 | Material & Labour for LT panel Board cubical KIOSK Outdoor type compact 415 Volts AC 50 Hz, fabricated of Thermoplastic (Polycarbonate), insulated, shock proof, dust proof, water proof, anticorrosive and confirming to IP 55 complete including Aluminium bus bar of 300 Amp capacity 4 strip mounted on porcelain insulated & enclosed in chamber & connection from incoming and outgoing with comprising of following :- NOTE : (a) The contractor should submit the IP Test Report and Verification of short circuit withstand Test report issued by CPRI in respect of LT Panel.(b)Contractor shall submit the drawing for approval prior to place the order.Make of Panel : Hensel/C&S/L&TMake of MCCB/MCB : Legrand/L&T/Schneider/Hager(a) Incoming - MCCB200 Amp FP 25 KA - 01 No (b) Outgoing - MCCB 100 Amp FP 18 KA-02 Nos (c ) MCB 80 Amp TP 16 KA-02 No(d ) MCB 63 Amp TP 10 KA-02 No(e) Digital panel meter for Amp, Volt, KWH, power factor and other parameter flush mounting of size 96 x 96 mm(f) Aluminium Bus bar RYB and N of 300 Amp capacity one set |
| 7 | Material & Labour for LT panel Board cubical KIOSK Outdoor type compact 415 Volts AC 50 Hz, fabricated of Thermoplastic (Polycarbonate), insulated, shock proof, dust proof, water proof, anticorrosive and confirming to IP 55 complete including Copperbus bar of 150 Amp capacity 4 strip mounted on porcelain insulated & enclosed in chamber & connection from incoming and outgoing with comprising of following :- NOTE : (a) The contractor should submit the IP Test Report and Verification of short circuit withstand Test report issued by CPRI in respect of LT Panel(b)Contractor shall submit the drawing for approval prior to place the order.Make of Panel : Hensel/C&S/L&TMake of MCCB/MCB : Legrand/L&T/Schneider/Hager(a) Incoming - MCCB125 Amp FP 25 KA - 01 No (b) Outgoing - MCCB 63 Amp TP 16 KA-03 Nos (c ) MCCB 40 Amp TP 16 KA-02 No(d) MCB 32 Amp TPN, 10 KA \"C\" curve- 02 Nos(e) Digital panel meter for Amp, Volt, KWH, power factor and other parameter flush mounting of size 96 x 96mm(f) CopperBus bar RYB and N of 400 Amp capacity one set |
| 8 | Supply and fixing mild steel galvanised earth strip of size 25 x 4 mm with epoxy insulators and fixing screws etc for earth continuity conductors to test point terminal, complete all as specified and directed by Engineer-in-Charge. |
| 9 | Material & Labour for bore Earthing 150mm bore for Earthing with galvanised steel pipe electrode, 40mm bore, medium grade, 3 metres length, top edge of GI pipe not less than 1.25 metres below ground level, connected with Earthing lead of 25 x 4mm GI strip to the Earthing test point and filling of charcoal dust, salt etc and testing on completion, complete all as specified and directed by Engineer-in-Charge. Note: IR Value should be less than 5 Ohms.Note: GI earth strip of size 25 x 4 including installation 7.5 Mtr is deemed to be included in the unit rate. |
| 10 | Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth for foundation / fixing pole / laying cable and pipe line etc., or for man hole etc., not exceeding 10 sqm on plan and getting out in hard soil, complete all as specified and directed by Engineer-in-Charge. |
| 11 | Returning filling in including spreading levelling, watering and well ramming in layers not exceeding 25cm thick using suitable excavated hard soil, complete all as specified and directed by Engineer-in-Charge. |
| 12 | Removing excavated soil to a distance exceeding 50 Metre but not exceeding 100 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point, complete all as specified and directed by Engineer-in-Charge. |
| 13 | Supply & Fixing of 4 Mtr. (Above ground) Ornamental Cast iron MS Pole with Single arm bracket of total height 04 Metre nominal above the founding top level with decorative orbit plus S round arm length 1000mm, with unbreakable SG iron base fabricated with cast iron embellishment, joints, column, sections etc with MS vertical shaft. Height of pole is inclusive with height of bracket as shown in drawing. The pole should be painted with polyurethane paint of approved colour finish including pole foundation with nut & bolts, MCB 6 Amps, complete all as specified and directed by Engineer-in-Charge. MAKE :Havells Cat part No: EROSPOLET03074M or equivalent Utkarsh/Bajaj |
| 14 | Supply & Fixing of Aesthetically designed IP 66 LED post Top with aluminium enclosure, powered with high power LEDs as light source and die casted heat sink exhibiting classic Victorian look with symmetrical light distribution, suspended mounting arrangement and excellent heat dissipation for long life of capacity 72 W LED suspension type decorative light fitting, Grey, complete all as specified and directed by Engineer-in-Charge. MAKE :Havells Cat part No: EROSPT73WLED757PSYMTOPC or equivalent Bajaj/Wipro |
| 15 | Supply and laying of XLPE insulated and PVC armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of size 16 Sqmm 4 Core laid in trenches / along the wall/pole including making good the disturbed surfaces of walls/floor etc., complete all as specified and directed by Engineer-in-Charge. |
| 16 | Supply and laying 50/38mm Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface of the inner wall confirming to IS14930 (Part-II) for protection, complete all as specified and directed by Engineer-in-Charge. |
| 17 | Supply & Fixing automatic street light switch NATURE SWITCH for automatic switching of streets lights based on lux level of natural light. The sensor (nature switch) along with suitable power contactor, MCB and support terminals should be enclosed in pole /wall mountable enclosure made out of rust proof, electric shock proof, termite proof and FR grade special moulding compound conforming to IP-54. The contactor, MCB and circuit wiring 16 sqmm copper shall be suitable, complete all as specified and directed by Engineer-in-Charge. Make :- Model No. SWADEEP-02EC-5kW3P (3 PHASE) of Healer or equivalent to Havells /L&T |