| Sl. No. | Item Description |
| 1 | Schedule \"A\" |
| 2 | Taking down carefully burnt out aluminium/copper point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets, fluorescent tube light fittings etc., to be measured and paid for separately) removing materials to store for schedule of credit and making good to the disturbed surfaces of walls ceilings and floors etc., complete all as specified and directed by Engineer-in-Charge. |
| 3 | Disconnecting of unserviceable sub main wiring of any size and including steel conduit and accessories & removing from site and making good the disturbed surfaces including painting, complete all as specified and directed by Engineer-in-Charge. |
| 4 | Disconnecting electric connection and taking down old unsv MCB DBs, of any capacity including MCBs, complete all as specified and directed by Engineer-in-Charge. |
| 5 | Material & Labour for point wiring using ISI marked 1.1 kV grade single core FR-LSH flexible cable, conforming to IS: 694-1990, having multi-drawn thin strands of electrolytic copper conductors in existing conduit/ Provision of PVC cassing capping as per site requirement size conforming to IS: 8130- 1984 and insulation conforming to IS: 5831- 1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25mm size PVC medium grade surface/recessed casing capping, modular cover-plates and frame complete all as specified in IS: 732- 1989, complete all as specified and directed by Engineer-in-Charge.NOTE: Circuit wire from DB to switch boards shall be included in quoted rate. Note (i) Existing Modular sheet metal box should not be removed (ii) Mounting plate and cover plate of existing size is to be replace and rate are deemed to be included in quoted rate.(iii) PVC cassing capping measured and paid under relevant Item. |
| 6 | One light /fan/exhaust point controlled by one, one way switch |
| 7 | One light point controlled by 2, Two way switch |
| 8 | One 5 pin socket outlet 5/6 amps on the same board. |
| 9 | One 5 pin socket outlet 5/6 amps on independent board. |
| 10 | One bell point controlled by one, one way switch. |
| 11 | Material & Labour for point wiring using ISI marked 1.1 kV grade single core FR-LSH flexible cable, conforming to IS: 694- 1990, having multi drawn thin strands of electrolytic copper conductors, conforming to IS: 8130- 1984 and insulation conforming to IS: 5831- 1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25mm size PVC medium grade surface/recessed cassing capping conforming to IS: 537 (Part 3)-1983, colour-coded as specified in IS: 11353-1985, and including modular cover plates complete all as specified in IS: 732- 1989, complete all as specified and directed by Engineer-in-Charge. Note:- (i) Existing Modular sheet metal box should not be removed (ii) Mounting plate and cover plate of existing size is to be replace and rate are deemed to be included in quoted rate. |
| 12 | One 16 Amp socket outlet, independent, with cables 4.0 mm² size |
| 13 | Supply & Fixing in replacement of modular type 6 Amp one-way SP switch, conforming to IS: 3854-1997 with finger proof terminal, complete all as specified and directed by Engineer-in-Charge. |
| 14 | Supply & Fixing replacement of modular type 16 Amp one-way SP switch, conforming to IS: 3854- 1997 with finger proof terminal, complete all as specified and directed by Engineer-in-Charge. |
| 15 | Supply & Fixing replacement of modular type 2/3 pin combined shuttered type 6 Amp socket conforming to IS: 1293- 2005, complete all as specified and directed by Engineer-in-Charge. |
| 16 | Supply & Fixing replacement of modular type 2/3 pin combined shuttered type 6/16 Amp socket conforming to IS: 1293- 2005, complete all as specified and directed by Engineer-in-Charge. |
| 17 | Supply & Fixing replacement of modular type 6 Amp bell-push conforming to IS: 8884- 1978 with finger proof terminal, complete all as specified and directed by Engineer-in-Charge. |
| 18 | Supply & Fixing replacement of Bell multi music type 230 Volt, complete all as specified and directed by Engineer-in-Charge. |
| 19 | Supply & Fixing in replacement of modular type 120 W step fan regulator of 2 module size, conforming to IS: 11037-1984, complete all as specified and directed by Engineer-in-Charge. |
| 20 | Supply & Fixing in replacement of 6 Amp, 250 V high quality robust surface/flush type polycarbonate/PVC ceiling rose, conforming to IS: 371- 1979, having 2/3 terminals and outside diameter not less than 63.5mm, complete all as specified and directed by Engineer-in-Charge. |
| 21 | Supply & Fixing in replacement of Modular switch 2 way 6 Amp, 1 module, complete all as specified and directed by Engineer-in-Charge. |
| 22 | Supply and fixing in replacement of PVC Modular surface box, complete all as specified and directed by Engineer-in-Charge. of following size:- |
| 23 | 1 or 2 Module of size 85mm x 85mm |
| 24 | 3 Module of size 85mm x 115mm |
| 25 | 4 Module of size 85mm x 145mm |
| 26 | 6 Module of size 132mm x 135mm |
| 27 | Supply and fixing in replacement of Modular cover plate with frame, complete all as specified and directed by Engineer-in-Charge.of following size:- |
| 28 | 1 or 2 Module of size 85mm x 85mm |
| 29 | 3 Module of size 85mm x 115mm |
| 30 | 4 Module of size 85mm x 145mm |
| 31 | 6 Module of size 132mm x 135mm |
| 32 | Supply & fixing in replacement of switch piano flush button, 240 volts, 6 Amps, single pole, one way (ISI marked), complete all as specified and directed by Engineer-in-Charge. |
| 33 | Supply & fixing in replacement of Socket outlet 2 in 1, 3 pin, 5 Amp flush type (ISI marked), complete all as specified and directed by Engineer-in-Charge. |
| 34 | Supply and fixing in replacement of Socket outlet 3 pin, 16 Amp, flush type, complete all as specified and directed by Engineer-in-Charge. |
| 35 | Supply and fixing in replacement of switch piano flush button 230 V, 16 Amps, Single pole, one way ISI marked, complete all as specified and directed by Engineer-in-Charge. |
| 36 | Supply and fixing of MCB DB sheet enclosure double door type, single pole and neutral 240 V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 16 way type, complete all as specified and directed by Engineer-in-Charge. |
| 37 | Supply and fixing of MCB DB sheet enclosure double door type, single pole and neutral 240 V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 12 way type, complete all as specified and directed by Engineer-in-Charge. |
| 38 | Supply and fixing of MCB DB sheet enclosure double door type, single pole and neutral 240 V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 8 way type, complete all as specified and directed by Engineer-in-Charge. |
| 39 | Supply and fixing of MCB DB sheet enclosure double door type, single pole and neutral 240V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 4 way type, complete all as specified and directed by Engineer-in-Charge. |
| 40 | Supply and fixing of MCB DB sheet enclosure double door type, triple pole and neutral 415 V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 6 way type, complete all as specified and directed by Engineer-in-Charge. |
| 41 | Supply and fixing of amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and directed by Engineer-in-Charge.of following size:- |
| 42 | MCB 6 to 32 Amps, single pole |
| 43 | MCB 32Amps, double Pole / SPN |
| 44 | MCB 40 to 63 Amps, double Pole / SPN |
| 45 | Supply and fixing of 415V 10KA \"C\" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning, complete all as specified and directed by Engineer-in-Charge.Of Following size:- |
| 46 | MCB, TP 25 to 63 Amps |
| 47 | MCB, TPN / FP 16 to 32 Amps |
| 48 | Material & Labour for sub-main wiring using ISI marked 1.1 kV grade single core FRLS flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831-1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25mm size in existing conduits / PVC Cassing capping surface/recessed conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall / ceiling / floor with painting, complete all as specified and directed by Engineer-in-Charge.NOTE: 01 run of phase conductor, 01 run of neutral conductor, 01 run of earth continuity conductor and 01 run of PVC Cassing capping shall be measured as one length. |
| 49 | 2 x 6.0 Sqmm + 1 x 6.0 Sqmm earth wire |
| 50 | 2 x 4.0 Sqmm + 1 x 4.0 Sqmm earth wire |
| 51 | 2 x 2.5 Sqmm + 1 x 2.5 Sqmm earth wire |
| 52 | Material & Labour for sub-main wiring using ISI marked 1.1 kV grade single core FRLS flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25mm size in existing conduits / PVC Cassing capping surface/recessed conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor with painting, complete all as specified and directed by Engineer-in-Charge. NOTE: 03 run of phase conductor, 01 run of neutral conductor, 02 run of earth continuity conductor and 01 run of PVC Cassing capping shall be measured as one length. |
| 53 | 4 x 6.0 Sqmm + 2 x4.0 Sqmm earth wire |
| 54 | 4 x 4.0 Sqmm + 1 x 2.5 Sqmm earth wire |
| 55 | Supply and fixing in replacement of casing capping of 25mm x 12mm size, complete all as specified and directed by Engineer-in-Charge. |
| 56 | Supply and fixing in replacement of casing capping of 32mm x 16mm size, complete all as specified and directed by Engineer-in-Charge. |
| 57 | Supply & Fixing in replacement of wall mounted LED Tube light fitting 1 x 10 W LED (6500K), 2 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified and directed by Engineer-in-Charge. |
| 58 | Supply & Fixing in replacement of wall mounted LED Tube light fitting 1 x 20W LED (6500K), 4 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified and directed by Engineer-in-Charge. |
| 59 | Supply & Fixing in replacement of LED Luminaires recessed mounted down lighter 18 watt 5700K system efficiency not less than 100lm/watt, thd<10% single phase including connecting cable from ceiling rose to terminal block of luminaires, complete all as specified and directed by Engineer-in-Charge. |
| 60 | Supply & Fixing in replacement of 6 W LED down light with multiple beam tilting angles, no UV radiation and dimmable ballast, complete all as specified and directed by Engineer-in-Charge. |
| 61 | Supply & Fixing in replacement of square shape slim recessed mounted LED down light of capacity 36 Watt (2ft x 2ft) with die cast housing finished in white powder coating, complete all as specified and directed by Engineer-in-Charge. |
| 62 | Supply & Fixing in replacement of square surface mounted LED down light of capacity 36 Watt (2ft x 2ft) with die cast housing finished in white powder coating, complete all as specified and directed by Engineer-in-Charge. |
| 63 | Supply & Fixing in replacement of 80 Watt LED bay light made of PDC aluminium housing with direct modular IP Lens, potted driver, 10 KV SPD, IP66and with system efficacy of 12lm/ including connecting cable from ceiling rose to terminal block of luminaires, complete all as specified and directed by Engineer-in-Charge. |
| 64 | Taking down ceiling fan 1200mm/1400mm sweep and Exhaust fan upto 250mm sweep complete servicing, painting of fan blade and body, repair of fan motor and replacement of worn out parts such as capacitor and bearing hanging of ceiling fan/Exhaust fan in situ, complete all as specified and directed by Engineer-in-Charge.Note: (i) Rewinding of fan motor will be measured and paid separately. |
| 65 | Dismantling of fan (1200mm sweep) motor, cutting of burnt winding of rotor and rewinding with same gauge copper wire winding with insulated material and reassembling, complete all as specified and directed by Engineer-in-Charge. |
| 66 | Dismantling of Exhaust fan 250/300mm sweep motor, cutting of burnt winding of rotor and rewinding with same gauge copper winding wire with insulated material and reassembling, complete all as specified and directed by Engineer-in-Charge. |
| 67 | Dismantling of Exhaust fan Plastic Body 250/300mm motor, and replace with new motor and reassembling, complete all as specified and directed by Engineer-in-Charge. |
| 68 | Supply and fixing in replacement of BLDC fan Printed circuit board(PCB) assembly with remote for 1200mm sweep suitable for existing, complete all as specified and directed by Engineer-in-Charge. |
| 69 | Supply only capacitor 2.5/3.15 mfd AC 230 volts for ceiling fans 1200/1400mm sweep and any make, complete all as specified and directed by Engineer-in-Charge. Make:- Epcos/ Unistar/ Usha/Bajaj or equivalent |
| 70 | Supply only capacitor 4 mfd suitable for exhaust fans 250/300mm sweep, complete all as specified and directed by Engineer-in-Charge.Make:- Epcos/ Unistar/ Usha/Bajaj or equivalent |
| 71 | Supply and fixing in replacement of ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), complete all as specified and directed by Engineer-in-Charge. |
| 72 | Supply and fixing in replacement of exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm, complete all as specified and directed by Engineer-in-Charge. |
| 73 | Dismantling electric/water connection and taking down of storage type water heater, servicing, cleaning of inner tank etc. at site and replacement of burnout parts etc. and re-fixing in situ, complete all as specified and directed by Engineer-in-Charge.Note- worn out parts shall be measured as separately. |
| 74 | Supply and fixing in replacement of spare parts of Geyser |
| 75 | Supply only Heating element 1.5 KW with rubber gasket. |
| 76 | Supply only Thermostat as per sample/suitable to 25 Ltrs capacity ISI marked. |
| 77 | Supply only Hot/Cold water connection pipe 450 mm length. |
| 78 | Supply only Geyser assembly as per sample suitable for 25 ltr capacity Make: Bajaj Model : Cladia |
| 79 | Supply only Indication lamp red and green suitable for geyser as required |
| 80 | 16 Amps top plug suitable as per existing socket |
| 81 | Supply and fixing in replacement of electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc., complete all as specified and directed by Engineer-in-Charge. |
| 82 | Material & Labour for annual servicing of Split Air conditioner cap 1.5/2.0 ton by disconnecting electric connection from its stabilizer or its electric board and remove the front cover or indoor AC unit and cleaning it with pressurized water and nylon brush, re-fixing the front cover of indoor unit. Remove the outer cover of outdoor unit and covered the condensing unit with ploythene/plastic cover so that water shall not be entered in the motor while cleaning the unit and filter with pressurized water then apply one coat of descaling solution and clean with wire mesh brush /nylon brush to the condensing coil of outdoor unit and greasing of all moving parts. Cleaning of Cooling and condenser coil of indoor and outdoor unit shall be properly carried out without damaging other parts. Checking and making serviceable electrical connection of DBs, Stabilizer, wiring of ACs as per site condition and tightening all electrical connection, complete all as specified and directed by Engineer-in-Charge.Note:- Replacement of defective parts with new parts shall be measured and paid separately under respective items in the schedule. |
| 83 | Material & Labour for detecting the cause of leakage in any type/capacity of 1.5/2 ton inverter / non inverter AC and ensuring the complete system leak proof and charging of refrigerant gas with appropriate quantity including testing for smooth functioning, complete all as specified and directed by Engineer-in-Charge.Notes :-(i) Dismantling of unserviceable compressor, cost of refrigerant gas and re-installation of serviceable compressor after repairing are deemed to be included in the quoted rates. |
| 84 | Taking down of outdoor/indoor unit of split type AC of capacity 1.5 tonne by duly dismantling copper coil, electrical connections mounting etc. and re-installing the same in new position with replacement MS bracket, and toping up of refrigerant gas and other items as per site requirement, complete all as specified and directed by Engineer-in-Charge. |
| 85 | Material and labour for maintenance of air conditioner 1.5/2.0 ton capacity, Split type unit with replacement of old/unsv spare parts mentioned as under or as per manufacturer instructions including testing on load, complete all as specified and directed by Engineer-in-Charge. |
| 86 | Supply & Fixing in repair over load protector suitable range and capacity |
| 87 | Supply & Fixing in repair Running capacitor of 36/45/50/60 + 5/6 mfd suitable for 240 volts 50 HZ AC Supply |
| 88 | Supply & Fixing in repair capacitor of 2.5 mfd suitable for blower fan motor of1.5/2.0 ton AC |
| 89 | Supply & Fixing in repair thermostat switch of suitable for 1.5/2.0 ton AC |
| 90 | Supply & Fixing in repair Contactor relay of suitable for 1.5/2.0 ton AC |
| 91 | Supply & Fixing in repairs Blower motor of 1/7 HP to 1/6 HP 230 volts 930 RPM, 20 Watt, 3 speed for indoor unit of split AC 1.5/2.0 TR of existing make complete |
| 92 | Supply & Fixing in repairs condenser fan motor 1/8 to 1/12 HP, 900/1400 RPM, 60 Watt suitable for 1.5/2 TR split AC outdoor unit, single phase, of existing make complete.Make:- LG/Bluestar/Voltas or as per existing make of AC at site. |
| 93 | Supply & Fixing in repairs Pre-air filter made up of PVC for indoor unit of split AC suitable for any make and description complete. |
| 94 | Supply & Fixing in repairs PVC fan blower assembly for 1.5 /2TR split AC\"s any make |
| 95 | Supply & Fixing in Replacement ofPrinted circuit board(PCB) with suitable for non-inverter type Split AC1.5/2.0 TR of any capacity, model and make as per existing complete with necessary electrical connection. |
| 96 | Material & Labour for replacement of defective cut open compressor/Uncut compressor suitable for air conditioner with new compressor filled with capila D and charging of refrigerant gas up to required capacity after flushing the complete refrigerant system including repair to leakage if any in refrigerant piping and replacement of filter complete for split type AC\"s, complete all as specified and directed by Engineer-in-Charge. of the following capacity |
| 97 | 1.5 ton capacity |
| 98 | 2.0 ton capacity |
| 99 | Supply & Fixing in repairs/replacement of condenser fan motor for outdoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make, complete all as specified and directed by Engineer-in-Charge. |
| 100 | Supply & Fixing in repairs / replacement of blower motor for indoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make, complete all as specified and directed by Engineer-in-Charge. |
| 101 | Supply & Fixing in replacement of Printed circuit board(PCB) with hand set of indoor and display unit suitable for Inverter type Split AC 1.5/2.0 TR of any capacity, model and make as per existing complete with necessary electrical connection, complete all as specified and directed by Engineer-in-Charge. |
| 102 | Supply & Fixing in repairs of Printed circuit board(PCB) with hand set of outdoor and display unit suitable for Inverter type Split AC 1.5/2.0 TR of any capacity, model and make as per existing complete with necessary electrical connection, complete all as specified and directed by Engineer-in-Charge. |
| 103 | Material & Labour for replacement of outdoor condenser unit of copper with 2 run of copper pipe of outdoor unit of split type AC 1.5/2.0 TR, complete all as specified and directed by Engineer-in-Charge. |
| 104 | Material & Labour for replacement of swing motor 230 Volt for 1.5/2.0 Ton indoor unit of split AC, complete all as specified and directed by Engineer-in-Charge. |
| 105 | Supply & Fixing in repairs Blade set of fan motor of outdoor unit, made out of Aluminium sheet Suitable for shaft bore dia 1/2\" and fan dia 16\"/ 18\" in existing air conditioner split type, complete all as specified and directed by Engineer-in-Charge. |
| 106 | Supply & Fixing in repairs Blade set of fan motor of outdoor unit, made out of PVC Suitable for shaft bore dia 1/2\" and fan dia 16\"/ 18\" in existing air conditioner split type, complete all as specified and directed by Engineer-in-Charge. |
| 107 | Supply & Fixing in repairs copper tubing of size 3/8\" suitable for split AC with nitrile self-adhesive foam wrapped with PVC insulation all around the pipe line, complete all as specified and directed by Engineer-in-Charge. |
| 108 | Supply & Fixing in repairs copper tubing of size 5/8\" suitable for split AC with nitrile self-adhesive foam wrapped with PVC insulation all around the pipe line, complete all as specified and directed by Engineer-in-Charge. |
| 109 | Supply and fixing in repair flexible PVC pipe for condense water outlet for Split AC as per existing, complete all as specified and directed by Engineer-in-Charge. |
| 110 | Material & Labour for charging of refrigerant R-410/R-22/R-32 gas to air conditioner or as per existing /manufacturer instructions suitable for split air conditioner cap 1.5 ton after flushing out the entire refrigerant, vacuum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas, as per manufacturer instructions, as mentioned above, complete all as specified and directed by Engineer-in-Charge. |
| 111 | All as per item no 67 above but for 2.0 ton capacity complete as per manufacturer instructions, complete all as specified and directed by Engineer-in-Charge. |
| 112 | Supply & Fixing in replacement of remote for split AC 1.5/2 Ton unit suitable for existing make and model including with battery, complete all as specified and directed by Engineer-in-Charge. |
| 113 | Supply & Fixing in replacement of outdoor unit stand of metal including fixing accessories such as nut bolt washers and fastener for 1.5/2 Ton outdoor unit, complete all as specified and directed by Engineer-in-Charge. |
| 114 | Material and labour for servicing/cleaning of water cooler of storage capacity/ nominal cooling capacity(Ltrs/hr) 80/40 & 120/60 litres with the use of anti-scaling agent for internal steel water tank, outer body and condenser coil of water cooler, Removal of dust and other deposited material for the various functional equipment using smooth nylon brush, cleaning of drainage for speedy water removal and checking of electrical connection to compressor and other electrically operated equipment’s, cleaning of fins and tubes of condenser, repair/replacement of PUF thermal insulation, checking of refrigerant leakage and functionality of water tap, complete all as specified and directed by Engineer-in-Charge. |
| 115 | Supply and fixing in replacement of hermetically sealed compressor of water cooler of capacity 40 ltr/hr suitable for R134a gas, single phase alongwith capacitor and relay, including gas charging in the system and testing of water cooler, complete all as specified and directed by Engineer-in-Charge.Make : Copeland/Tecumseh.Note : Cost of cutting of existing worn out compressor will be deemed to be included in unit rate. |
| 116 | Taking out burnt unserviceable condenser fan motor, and replacement with new electric motor, single phase 230V of water cooler 40ltrs/hrs with condenser fan blade, complete all as specified and directed by Engineer-in-Charge. |
| 117 | Supply and fixing in replacement of following items of water cooler |
| 118 | Thermostat for water cooler capacity 40/80 ltr/hrs. |
| 119 | Push type Bib tap Cast copper alloy 15mm Push type chromium plated. |
| 120 | PVC Connection with brass unions at both ends with brass nuts, suitable for fixing to 15mm dia GI Pipe. |
| 121 | Supply & Fixing in repair / replacement of over load protector suitable range and capacity for Refrigerator |
| 122 | Material and labour for carrying out repair /maintenance/ servicing of Refrigerator of any capacity by periodic cleaning of internal and external parts, cleaning of water collection area and checking of electrical circuit repair/ replacement of unserviceable/worn out spares and accessories to make the Refrigerator in good working condition, complete all as specified and directed by Engineer-in-Charge. Note: Defective spares required for replacement shall be measured and paid separately under respective items. |
| 123 | Material and labour for maintenance of Refrigerator any capacity with replacement of old/unsv spare parts as under including testing on load, complete all as specified and directed by Engineer-in-Charge. |
| 124 | Supply & Fixing in repair condenser suitable for Refrigerator of 195/ 250/ 300 ltr cap |
| 125 | Supply & Fixing in repair cooling effect transmitting fan motor suitable for Refrigerator of 195/ 250 / 300 ltr cap |
| 126 | Supply & Fixing in repair Compressor Relay suitable for Refrigerator of 195/250 / 300 ltr cap or as per existingMake KCL/Rentrol /Indofos |
| 127 | Supply & Fixing in repair thermostat suitable for Refrigerator of 195/250 / 300 ltr cap |
| 128 | Supply & Fixing in repair Compressor suitable for Refrigerator of 195 / 300 ltr cap or as per existing |
| 129 | Supply & Fixing in repair frost free fan motor suitable for Refrigerator of 195 / 300 ltr cap or as per existing |
| 130 | Supply & Fixing in repair defrost timer suitable for Refrigerator of 195 / 300 ltr cap or as per existing |
| 131 | Material & Labour for charging of refrigerant R-134a gas to Refrigerator for the following capacities as per existing /manufacturer instructions after flushing out the entire refrigerant, vacuum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas, as per manufacturer instructions, as mentioned above, complete all as specified and directed by Engineer-in-Charge. |
| 132 | Refrigerator cap 230/250 Ltrs |
| 133 | Earthing complete with galvanised steel earth plate electrode 60cm × 60cm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less ‘than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to Earthing test point all as specified or indicated including testing on completion, including taking down old unserviceable Earhting, complete all as specified and directed by Engineer-in-Charge. |
| 134 | Material and labour for painting of the transformer 100 KVA to 400 KVA, RMU, VCB and CSS Body complete by removing old paint by scrapping and providing spray painting with epoxy paint of approved (suitable for existing colour) make duly marking/writing MES/SM No., complete all as specified and directed by Engr-in-Charge. |
| 135 | Material and labour for painting of the transformer 500 KVA to 1000 KVA, RMU, VCB and CSS Body complete by removing old paint by scrapping and providing spray painting with epoxy paint of approved (suitable for existing colour) make duly marking/writing MES/SM No., complete all as specified and directed by Engr-in-Charge. |
| 136 | Taking out UNSV HT UG cables of any sizes from trenches, complete all as specified and directed by Engr-in-Charge. |
| 137 | Supply & Laying of HT underground cable 11000 volts grade, XLPE insulated screened PVC bedded, armoured with galvanised round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts, fixed on poles/walls with proper size saddles and clamp laid under roads/ path/drain/ culverts or encased in GI pipe fixed & testing and commissioning, complete all as specified and directed by Engr-in-Charge.for following size of cable:- Note : for Item No 81 Removing of interlocking/Paver blocks, tiles and re-fixing with the same location and making good the disturbed surface is deemed to be included in quoted rate.(ii) Fixing accessories for cable laying such as clamps and nut bolts are to be included in quoted rate. |
| 138 | 120 Sqmm 3 Core |
| 139 | 185 Sqmm 3 Core |
| 140 | 240 Sqmm 3 core |
| 141 | Supply & Fixing in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for Straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 coreXLPE armoured aluminium conductor cable,complete all as specified and directed by Engr-in-Charge.for following size of cable |
| 142 | 95 Sqmm 3core |
| 143 | 120 to 185 Sqmm 3core |
| 144 | 240 Sqmm 3core |
| 145 | Supply & Fixing in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for Indoor type termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductorcable of size 120 to185 Sqmm, complete all as specified and directed by Engr-in-Charge. |
| 146 | Supply & Fixing in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for Outdoor type termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductorcable of size 120 to185 Sqmm, complete all as specified and directed by Engr-in-Charge. |
| 147 | Supply & Fixing in replacement air break switch triple pole, 11KV, mechanically operated mounted on polymeric insulators and steel frame, with operating mechanism worked from ground level, for current rating up to 200 amps complete withincluding insulators horizontal /vertical rod and operating pipe of suitable size and length including taking down the old unserviceable air break switch, jumper connections and reconnecting of suitable size and length and making connection to new AB switchgang operated, complete all as specified and directed by Engr-in-Charge.Make: Jaipuria / Atlas / Pactil |
| 148 | Supply & Fixing in replacement of Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo am for 11 KV (triple pole set -1)as per existing make and model and directed at site, complete all as specified and directed by Engr-in-Charge. |
| 149 | Preventive Maintenance and Servicing, 11/0.433 KV Step down Transformer Indoor and Oil Cooled type by disconnecting carefully electric connection on primary & secondary side, Checking both side HT bushing, bushing rod, opening top cover of the transformer by unscrewing nuts, bolts, washers etc., rectify the oil leakages issues, if noticed any from the entire body of the transformer, during servicing and re-fixing the top cover of transformer according to previous system. Servicing of the transformer must be done through OEM or authorised personnel including maintaining and submitting the inspection and testing records of each transformer to the Engr-in-Charge. Note 1. :-Inspection of transformer shall involve :-(a) Checking of all clamps, nuts, bolts including core bolts & cover fixing bolts etc.(b)Checking all brazing’s, joints, tap heads, gaskets and connection joints.(c)Checking all terminations / connections inside/outside the transformer.(d)Checking of off load tap changer assembly, checking the moving and fixed contacts for contact wear and connection to winding.(e)Conducting the test on core and windings as per IS like ratio, magnetic imbalance, short circuit, IR Value, High Voltage Test etc. in presence of Engr-in-Charge.Note 2. :Spares used bushes studs HT/LT, bushing rod HT/LT, transformer oil, filtration of oil, buchholtz relay, Gaskets set, Off Load Change over switch etc will be measured and paid separately under respective item of BOQ.Note 3 :- The rates quoted against the item is deemed to be included for cost of Labour for lifting/transporting to civil workshop and vice-versa, if required as per site requirement. |
| 150 | 100 to 630 KVA |
| 151 | Material & Labour for Dehydration/Filtration of transformer oil at site by means of centrifuging machine in order to improve dielectric strength of oil as per IS-355. Break down voltage should not be less than 50 KV, complete all as specified and directed by Engr-in-Charge. |
| 152 | Material & Labour Transformer oil having di-electric strength of 60 KV as per IS complete for top up/ replacement, complete all as specified and directed by Engr-in-Charge.(Oil should be supplied in sealed barrel of Power/Transol brand)Note: oil shall be filled in the transformers/stabilizers to be repaired or installed at site at different locations. |
| 153 | Supply & Fixing in replacement of Silica Gel (Moisture absorbent chemical ) for breather of transformer 11 KV /433 Volt of any make / rating, complete all as specified and directed by Engr-in-Charge. |
| 154 | Supply & Fixing in replacement of oil temperature indicator gauge suitable for transformer of capacity 11KV/433 Volt, complete all as specified and directed by Engr-in-Charge. |
| 155 | Supply & Fixing in replacement of LT bushings with brass studs complete washer with nuts bolts and washers of brass of suitable size for 200 KVA to 630 KVA transformers, complete all as specified and directed by Engr-in-Charge. |
| 156 | Supply & Fixing in replacement of HT bushing with brass studs complete washer with nuts bolts and washers of brass of suitable size for 200 KVA to 630 KVA transformers, complete all as specified and directed by Engr-in-Charge. |
| 157 | Supply & Fixing in replacement of lightning arrester suitable for 11 KV as per existing make and model and directed at site, complete all as specified and directed by Engr-in-Charge. |
| 158 | Material & Labour for Maintenance/Over hauling of HT VCB 11 KV by taking shunt down with prior intimation and cleaning of HT VCB by using air blower, tightening the control circuit, Checking the all fuses, to ensure the smooth functioning of HT VCBby employingthe Skilled trades man and helper, complete all as specified and directed by Engr-in-Charge.Note: Rate Include following (i) Replacement of small piece of wire of sq area up to 1.5 sqmm Control Ckt cable) of Max length 5 Mtrs and replacement of unserviceable indicator lamps asper colour code all as specified and as directed by Engineer- In - Charge. (ii) Rack out /Down the HT VCB kept in Test position, Check the megger value of VCB terminals with body by suitable HT megger of range 5000 Volt and check the serviceability of Earthing connection by Earth megger note down the readings. |
| 159 | Supply & Fixing in replacement of charging motor suitable for 11 KV VCB 630/800 Amps as per existing make and model, complete all as specified and directed by Engr-in-Charge. |
| 160 | Supply & Fixing in replacement of closing coil 24 Volt DC suitable for 11 KV VCB 630/800 Amps as per existing make and model, complete all as specified and directed by Engr-in-Charge. |
| 161 | Supply & Fixing in replacement of Tripping coil 24 Volt DC suitable for 11 KV VCB 630/800Amps as per existing make and model, complete all as specified and directed by Engr-in-Charge. |
| 162 | Supply & Fixing in replacement of master Trip Relay 110 volt DC suitable for 11 KV VCB 630/800 Amps as per existing make and model, complete all as specified and directed by Engr-in-Charge. |
| 163 | Supply & Fixing in replacement of Auxiliary Relay 110 volt DC suitable for 11 KV VCB 630/800Amps as per existing make and model, complete all as specified and directed by Engr-in-Charge. |
| 164 | Supply & Fixing in replacement of vacuum bottle suitable for 11 KV VCB 630/800 Amps as per existing make and model, complete all as specified and directed by Engr-in-Charge. |
| 165 | Supply & Fixing in replacement of Finger contacts for 2 Nos suitable for 11 KV VCB 630/ 800 Amps as per existing make and model, complete all as specified and directed by Engr-in-Charge. |
| 166 | Supply & Fixing in replacement of indication LED lights for each phase of 230 Volt, complete all as specified and directed by Engr-in-Charge. |
| 167 | Supply & Fixing in replacement of indication panel suitable for 11 KV VCB 630/800 Amps as per existing make and model, complete all as specified and directed by Engr-in-Charge. |
| 168 | Supply & Fixing in replacement of automatic selector switch 230Volt 6 Amp, complete all as specified and directed by Engr-in-Charge. |
| 169 | Supply & Fixing in replacement of protection Relay (over short Circuit /earth fault) 110 volt DC suitable for 11 KV VCB 630/800 Amps as per existing make and model, complete all as specified and directed by Engr-in-Charge. |
| 170 | Supply & Fixing in replacement bus bar spout top for RYB suitable for 11 KV VCB 800 Amps as per existing make and model, complete all as specified and directed by Engr-in-Charge. |
| 171 | Supply & Fixing in replacement bus bar spout Bottom for RYB suitable for 11 KV VCB 800 Amps as per existing make and model. complete all as specified and directed by Engr-in-Charge. |
| 172 | Supply & Fixing in replacement of space heater and Thermostat set suitable for 11 KV VCB 800 Amps as per existing make and model, complete all as specified and directed by Engr-in-Charge. |
| 173 | Supply & Fixing in replacement of male and female spout suitable for existing PT, for 11 KV VCB of cap 630 Amps as per existing make and model, complete all as specified and directed by Engr-in-Charge. |
| 174 | Supply & Fixing in replacement of HT 11 KV drop out fuse assembly with insulator and base including fuse tube, fuse carrier top connectors incoming and outgoing connectors, complete all as specified and directed by Engr-in-Charge.Note: Rate include taking down existing unserviceable/ Faulty DO fuse assembly and fix the new one and make the incoming and outgoing connections and switch on the supply through the new DO fuse assembly all as directed by EIC. |
| 175 | Material & Labour for preventive maintenance of HT ring main unit at main receiving substation comprising of one incoming Two out going as per manufacture specification, work is to be carried out with prior intimation, and taking shut down of Ring main unit, earth the unit completely, complete all as specified and directed by Engr-in-Charge.Scope of work consist of following (a) Check and clean termination and bushing compartment(b) Checking of sealing of gland plate area(c) Checking of mechanical interlock(d) Checkclose and trip coil condition and gap setting(e) Checking of control circuit , fuses and Electrical interlocks(f) Following testshould be carried out at site (i) Test the insulation testing of each Breaker/Isolator (ii) Test Test contacts of breaker and isolators (iii)Check /Reset therelays(g) Checking/Testing of Relays as per following (i) Functional verification of Individual feeder by switch On /Off by both incoming so as to confirm with both incoming unit is functional (ii) Check the auxiliary supply and control voltage , (iii) Check the power pack unit and its Voltage. (iv) Check the CT connections, inspection and testing of closing and trip coil by using external test kit.Note: Contractor has to submit the inspection report to department after completion of work |
| 176 | Supplying and laying in replacement of synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m, complete all as specified and directed by Engr-in-Charge. |
| 177 | Supply & Fixing in replacement of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bonesin signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 25x20cm size, complete all as specified and directed by Engr-in-Charge. |
| 178 | Supply & Fixing in replacement of Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and weldingin two halves made to shape to suit the cross section of the pole, complete all as specified and directed by Engr-in-Charge. |
| 179 | Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth and getting out in hard/dense soil, complete all as specified and directed by Engr-in-Charge. |
| 180 | Returning filling in including spreading levelling watering and well Ramming in layers not exc 25 cm thick, complete all as specified and directed by Engr-in-Charge. |
| 181 | Removing excavated material not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point, complete all as specified and directed by Engr-in-Charge. |
| 182 | Material & Labour for cutting existing road/hard standing not exc 45 x 45 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well ramming watering finish surface 10 cm from top using PCC 1:2:4; including removal of surpluses soil, complete all as specified and directed by Engr-in-Charge. |
| 183 | Servicing and repair of APFC panel upto 300 KVAR by replacement of worn out spare parts and cleaning of the serviceable contactors and tightening/ checking of all internal electrical connections and accessories to maintain PF not less than 0.99 by adjusting/ calibrating the APFC relay of any type, complete all as specified and directed by Engr-in-Charge.Note: Defective parts if any will be measured and paid separately. |
| 184 | Supply & Fixing in replacement of heavy duty gas filled Capacitor 5 KVAR, 440V, 3 phase, 50 Hz, complete all as specified and directed by Engr-in-Charge.Make: L&T/Epcos/Schneider/C&S |
| 185 | Supply & Fixing in replacement of heavy duty gas filled Capacitor 10 KVAR, 440V, 3 phase, 50 Hz, complete all as specified and directed by Engr-in-Charge.Make: L&T/Epcos/Schneider/C&S |
| 186 | Supply & Fixing in replacement of heavy duty gas filled Capacitor 20 KVAR, 440V, 3 phase, 50 Hz, complete all as specified and directed by Engr-in-Charge.Make: L&T/Epcos/Schneider/C&S |
| 187 | Supply & Fixing in replacement of heavy duty gas filled Capacitor 25 KVAR, 440V, 3 phase, 50 Hz, complete all as specified and directed by Engr-in-Charge.Make: L&T/Epcos/Schneider/C&S |
| 188 | Supply & Fixing in replacement of 6 Steps APFC Relay, microprocessor based and connected items, complete all as specified and directed by Engr-in-Charge.Make: L&T/Epcos/Schneider/C&S |
| 189 | Material & Labour for apply two coat of epoxy paint on LT Panels of any size, including preparation of rusted surface of panel by means of sand paper/scrubbing of dust etc and apply one coat of epoxy based primer before painting, complete all as specified and directed by Engr-in-Charge.Note: Minor repair/ replacement of hinges suitable for screw fasteners and fixed in original position deemed to be included in unit rate. |
| 190 | Supply & Fixing in replacement of Digital time switches (SST 15 min) for street light 215 V single Phase, complete all as specified and directed by Engr-in-Charge.Make :L&T/Havells |
| 191 | Material & Labour for preparation of old painted surfaces of Steel Tubular pole upto 6 to 9 Mtr long by scarping old paint and applying Single coat of Aluminium paint including numbering of pole with black oil paint and painting the base of the pole in alternate black and Blue stripes each 30 cm (5 Strips) apart up to 1.5 Mtr height and including one coat white distempering for pole foundation above ground level shall deemed to be included in the quoted rate etc., complete all as specified and directed by Engr-in-Charge. |
| 192 | Material & Labour in replacement of Cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (heat shrinkable) and accessories suitable for 3½/ 4 core XLPE armoured Al conductor, complete all as specified and directed by Engr-in-Charge.cable of following sizes-Make-Denson/Raychem/3M, |
| 193 | 25 Sqmm to 50 Sqmm |
| 194 | 70 Sqmm to 120 Sqmm |
| 195 | 150 Sqmm to 185 Sqmm |
| 196 | Taking out UNSV LT UG cables of any sizes from trenches, complete all as specified and directed by Engr-in-Charge. |
| 197 | Supply & Laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, complete all as specified and directed by Engr-in-Charge.of cross-sectional area:- |
| 198 | 16 Sqmm 4 Core |
| 199 | 25 Sqmm 4 Core |
| 200 | 35 Sqmm 4 Core |
| 201 | 50 Sqmm 3.5 Core |
| 202 | 70 Sqmm 3.5 Core |
| 203 | 95 Sqmm 3.5 Core |
| 204 | Material and Labour for DWC pipelaying in trenches/ under floor/on walls for protection of UG cables, complete with coupler and connected accessories, including taking down old unserviceable DWC Pipe, complete all as specified and directed by Engr-in-Charge.Note: Cutting of floor/ road and making good with PCC deemed to be included in item rate.of following sizes:-Make: Rex/Poly/Gemini |
| 205 | 50/38mm |
| 206 | 63/50mm |
| 207 | 90/76mm |
| 208 | Supply & Fixing in replacement of MCB/MCCB FP, 415 V fixed type, including taking down of old unsv panel after disconnecting Existing cables and reconnecting the cables with proper lugs and glands, complete all as specified and directed by Engr-in-Charge.of following:-Make: Havells/ L&T / ABB /Schneider |
| 209 | MCCB 63/100 Amp FP, 415 V breaking capacity25 KA |
| 210 | MCCB 200 Amp FP, 415 V breaking capacity25 KA |
| 211 | MCCB 250 Amp FP, 415 V breaking capacity 36 KA |
| 212 | MCB 63 Amps FP, 415 V breaking capacity 10 KA |
| 213 | MCB 6 TO 32Amps SP, 240 V breaking capacity 10 KA |
| 214 | Dismantling and taking down the existing defective street light /flood light fitting of any type and any capacity LED street light from steel tubular pole, opening the street light fitting, checking the serviceability, remove the cable carbon and replacement of 3 Core 1.5 Sqmm size multi-stranded copper conductor including taking down old unsv 3 Core 1.5 Sqmm size copper conductor, complete all as specified and directed by Engr-in-Charge.Note:- 1.5 Sqmm 3 core size multi-stranded copper conductor etc will be measured and paid separately. |
| 215 | Supply & Fixing in replacement of street light fitting LED type 70 watts with Pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening separate driver compartment with IP66 protection and including driver unit etc and taking down old unsv any size/watt of security light, complete all as specified and directed by Engr-in-Charge. |
| 216 | Supply & Fixing in replacement of LED flood Light fitting 150 watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, including taking down old light fitting of any description, complete all as specified and directed by Engr-in-Charge.Make:Wipro/Philips/Crompton |
| 217 | Supply & Fixing in replacement of LED flood Light fitting 200 watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, including taking down old light fitting of any description, complete all as specified and directed by Engr-in-Charge.Make:Wipro/Philips/Crompton |
| 218 | Supply & Fixing in replacement of LED ornamental street light with lens & spun aluminium designer housing with clear with clear acrylic for city beautification, IP65, and with system efficacy of 100lm/ w fitting 90 watt, fixed on existing pole & connecting, including taking down old light fitting, complete all as specified and directed by Engr-in-Charge.Make:Bajaj/Crompton/Wipro/Halonix cat part no HLOSL-04-90CWL |
| 219 | Supply & Fixing in replacement of Multi standard Copper Conductor cable of size 1.5 Sqmm 3 Core, inclusive of all tees, bends, elbows, reducers and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for interconnection of cable light/looping box to street light fitting etc., complete all as specified and directed by Engr-in-Charge. |
| 220 | Supply & Fixing in repair 4 pole power contactor MCX-13, 50 Hz, complete all as specified and directed by Engr-in-Charge. Make : L&T or equivalent |
| 221 | Supply & Fixing in repair power Relay MNX - A1,/MNX - A2, 50 Hz, complete all as specified and directed by Engr-in-Charge.Make : L&T or equivalent |
| 222 | Supply & Fixing in replacement of Bldg Security light fitting LED type 25 watts with Pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening separate driver compartment with IP66 protection and including driver unit etc and taking down old unsv any size/watt of security light, complete all as specified and directed by Engr-in-Charge.Make: Wipro or equivalent from Bajaj/Philips |
| 223 | Supply & Fixing in replacement of LED Bollard 11W, IP 65, Die cast aluminium housing with polycarbonate cover, operating voltage 220-240 V, 50 Hz, pole mounted, including PCC 1:2:4 type B1 (20mm graded aggregate) base of size 300mm x 300mm and depth 600mm for fixing of Bollard with nuts bolts etc required as per site, complete all as specified and directed by Engr-in-Charge.Make : Wipro Cat No LB13/14-131-xxx-65-08or equivalent from Philips/CG/BajajNote: Apply for single coat of suitable colour distempering for bollard foundation shall deemed to be included in the quoted rate. |
| 224 | Supply & Fixing in replacement of LED Bollard 10W, IP 65, Die cast aluminium housing with polycarbonate cover, operating voltage 220-240 V, pole mounted, including PCC 1:2:4 type, base of size 300mm x 300mm and depth 500mm for fixing of Bollard with nuts bolts etc required as per site, complete all as specified and directed by Engr-in-Charge.Make : Crompton Cat No LBLSN-10-CDL or its equivalent in Bajaj/Wipro/Philips |
| 225 | Supply & Fixing in replacement of automatic street light switch (5 KW to 8 KW) Amps rating 20 Amps NATURE SWITCH for automatic switching of streets lights based on lux level of natural light. The sensor (nature switch) along with suitable power contactor, MCB and support terminals should be enclosed in pole /wall mountable enclosure made out of rust proof, electric shock proof, termite proof and FR grade special moulding compound conforming to IP-54. The contactor, MCB and circuit wiring 16/10 sqmm copper shall be suitable, complete all as specified and directed by Engr-in-Charge.Make :- Model No. SWADEEP-02EC-5KW, 3P (3 PHASE) of Healer or equivalent to Havells /L&T |
| 226 | Supply & Fixing in replacement of Pole box with 6 Amps MCB provision and suitable connector for single hose connections loop in and out 10 to 16 Sqmm 4 core aluminium armoured cable branch out 1.5 Sqmm single core copper PVC insulated cable enclosed in a thermoplastic polycarbonate enclosure which should be shock proof safe IP 66/67 weather proof, rust proof, dust proof, water proof, internally embedded gasket with provision for cable entry through IP 66/67 thermoplastic metric size glands and/or grommets enclosure size (155 x 210 x 92mm ), fixing arrangement and clamps including making connections, complete all as specified and directed by Engr-in-Charge. (Cat Part No KF 1616 Gof Make :Hensel or equivalent model of Sintex) |
| 227 | Supply & Fixing in replacement of Aluminium lugs long barrel of size 185-240sqmm, complete all as specified and directed by Engr-in-Charge.Make: Dowells or equivalent |
| 228 | Supply & Fixing in replacement of Aluminium lugs long barrel of size 120-150 sqmm, complete all as specified and directed by Engr-in-Charge. Make: Dowells or equivalent |
| 229 | Supply & Fixing in replacement of Aluminium lugs long barrel of size 70-95 sqmm, complete all as specified and directed by Engr-in-Charge. Make: Dowells or equivalent |
| 230 | Supply & Fixing in replacement of Aluminium lugs long barrel of size 35-50 sqmm, complete all as specified and directed by Engr-in-Charge. Make: Dowells or equivalent |
| 231 | Supply & Fixing in replacement of Aluminium lugs long barrel of size 16-25 sqmm, complete all as specified and directed by Engr-in-Charge.Make: Dowells or equivalent |
| 232 | Supply & Fixing in replacement Octagonal hot dip galvanised iron pole, 7m long, top dia 70mm, bottom dia 130mm, section -1 (section length- 7000mm) thick -3mm with base plate 220x220x12mm, PCD 220mm. baseplate hole dia suitable for M 20 foundation bolts, 700mm long, 4 nos weather proof reinforced door opening with junction box mounting arrangement, inbuilt junction box, \"J\" shape, EN8 foundation bolt with nuts template including RCC foundation as per manufacturer’s design conforming to IS 1786 and hot dip galvanised bracket Single arm 1000mm long for fixing of street light and two nos of MCB 6 Amp includingterminal block all as spd and directed. The foundation shall extend above surrounding levels by 200mm, complete all as specified and directed by Engr-in-Charge. Make : Wipro/Surya/ Bajaj /UtkarshNOTE :The contractor should submit manufacturer\"s foundation drawing before commencement of foundation work. Excavation/earthwork, removal and returning filling included in the quoted rate. |
| 233 | Material and Labour for painting the MS supporting structure of solar ON Grid power plant up to capacity 90/45/40/20KW, complete as per original shade with two coats of synthetic enamel paint over one coat of primer by spray gun after scrapping the existing paint, denting, filling depression with putty etc., complete all as specified and directed by Engr-in-Charge. |
| 234 | Material & Labour for bore Earthing 150mm bore for Earthing with galvanised steel pipe electrode, 40mm bore, medium grade, 3 metres length, top edge of GI pipe not less than 1.25 metres below ground level, connected with Earthing lead of 25 x 4 mm GI strip to the Earthing test point and filling of charcoal dust, salt etc and testing on completion, including taking down old unserviceable Earthing, complete all as specified and directed by Engr-in-Charge.Note: IR Value should be less than 5 Ohms.Note: GI earth strip of size 25 x 4 including installation 7.5 Mtr is deemed to be included in the unit rate. |
| 235 | Supply & Fixing in repair aluminium earth strip of size 25 x 3 mm with epoxy insulators and fixing screws etc for earth continuity conductors to test point terminal including taking down old strip, complete all as specified and directed by Engr-in-Charge. |
| 236 | Deployment of manpower, instrument, tools, and all connected accessories for testing of earth resistance of existing Earthing at provided earth test point for each earth set by competent calibrated digital earth test meter electronic type along with accessories (earth rod set with Cu wire with clips) and recording the result dully signed with date by MES representative and contractor, complete all as specified and directed by Engr-in-Charge.NOTE:- (a) Testing of each Earthing shall be carried out at the interval of 3 months and measurement shall be done each time separately and test result shall be maintained dully signed with date by MES representative and contractor. (b) Pouring of water in each earth pit is deemed to be included in the rate quoted.(c) Necessary arrangement to be made by the contractor for pouring the water in earth pits.Vehicle reqd for carrying/storage of water (upto to the site) with helper will be arranged by contractor and deemed to be included in the rate quoted.(d) Cost of Maintenance of carrying vehicle (if any) and cost of fuel reqd for veh is deemed to be included in the rate quoted. |
| 237 | Supply & Fixing in replacement of thermoplastic polycarbonate three phase connector 415 volts, IP 65/66 electric shock proof for street light pole mounted on steel channelincluding provision of 6 Amps SP MCB complete fixing arrangement all, complete all as specified and directed by Engr-in-Charge. |
| 238 | Material & Labour for marking of Earthing pit (GI earth / Copper earth / Chemical earth) with two or more coat synthetic enamel paint, colour & pattern as approved by the Engr-in-Charge, Letter size shall not be less than 50 mm, complete all as specified and directed by Engr-in-Charge. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail