| 1 | Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sqm on plan and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed |
| 2 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-Charge |
| 3 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified |
| 4 | M&L for PCC 1:4:8 type D-2 using 40mm graded crushed hard granite stone aggregate as in foundation, filling mass concrete complete all as specified and directed |
| 5 | M&L for brick work with sub class \"B\" bricks, straight or curved on plan exceeding 6 m mean radius built in CM 1:6 complete all as specified and directed by Engineer-in-Charge |
| 6 | M&L for brick work with sub class \"B\" bricks using old size bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed. |
| 7 | M&L for PCC 1:3:6 type C-0 (using 12.5mm graded aggregate) as in back filling of pressed steel frames, bed blocks, coping, fixing of hold fasts etc. including necessary formwork complete all as specified and directed by Engineer-in-Charge |
| 8 | M&L for rendering 15 mm thick in patches in cement mortar in 1:4 on fair face of brick work or concrete surfaces even and smooth without using extra cement and with using integral water proofing compound complete all as specified and directed |
| 9 | Supply only WPC (Integral water proofing compound) all as specified |
| 10 | S&F Reinforced concrete pipes class NP-2 laid, jointed and tested complete with collar of size 450 mm (internal dia) complete all as specified and directed by Engineer-in-Charge |
| 11 | M&L for 150mm thick concrete bed 1:3:6 type C-2 to drain pipes of 450mm (internal dia) including packing under, and haunching against the sides of pipes after they are laid and tested; in complete all as specified and directed |
| 12 | S&F Framed work such as grills, Ventilator frame, Steel Door Frame, Steel Door Shutter, gratings, cooler stand, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified. |
| 13 | Supply, installation, testing & commissioning of Hi Wall Split Units indoor and outdoor complete with cordless remote control unit and within built air ioniser and plasma filter for better indoor air quality of capacity 1.5 TR 230 voltAC 50 c/sBEE star rating as comprising of the following:-(a)1.5 Ton capacity using Eco friendly refrigerant cooling unit wall mounting type complete with remote control draining out arrangement manually adjustable cover for cool air from front with and inter connection with the condensing unit etc all as specified and directed by Engineer-in-Charge.(b) One No condensing unit of 1.5 ton capacity comprising of all fitting such as single phase electric driven compressor, condensing fan motor, condenser with fixing of stand on wall and all necessary controls and accessories all as specified and directed by Engineer-in-Charge.Note : Additional length for copper tubing if required at site shall be supply and fix by the contractor without any extra cost. |
| 14 | S&F sub main wiring with two runs of single core PVC, FRLS sheathed, insulated, copper cable of 4 Sqmm size, multi stranded, 1100 volts grade with PVC insulated FRLS copper wire 4 Sqmm for continuous earth wire drawn into and including PVC concealed conduitofsize not less than 20mm dia complete all as specifiedand directed . Note :- Two runs of 4 Sqmm copper cable and one run of 4 sqmm copper wire earth continuity conductor in conduit with accessories shall be measured as one length) |
| 15 | S&F single pole and neutral enclosure with 2 pin earth industrial plug and socket complete with one MCB SP 20 Amps all as specified and directed |
| 16 | S&F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 270 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed |
| 17 | S&F MCB SP 6 to 32 Amps, 240 V, 50 Hz AC complete all as specified and directed |
| 18 | Drawing ceiling fan from MES store yard Assembly & fixing on site ceiling fan 1200mm sweep connection from ceiling rose to fan connector complete all as specified and directed |
| 19 | Installation only refrigerator electric driven single phase 230 volts AC single 50 Hz of capacity minimum 190 Ltrs including transportation from BSO Yard to site complete all as specified |