| 1 | Taking down MCB, DB any Type including MCBs and making good to the disturbed walls and surface area etc all as specified and directed. |
| 2 | Taking down any type garden light fitting street light fitting including electric connection etc all as specified and directed |
| 3 | S&F LED garden light (Bollard type) light fitting luminaries of 9/10 watt in round shape with 0.75 mtr height of 3000k with IP 65. PF > 0.90 complete with all accessories including necessary excavation, PCC, connections with twin core copper cable 1.5 Sqmm complete all as specified and directed |
| 4 | S&F LED Post top lantern 25 watt made in cast aluminium with decorative opal polycarbonate diffuser with IP 65protection round shape PF> 0.90 complete with all accessories including necessary Suitable Size of GI pipe and connections with 1.5 sq mm 2 run copper cable complete all as specified and directed |
| 5 | S&F energy efficient LED street light fitting of 60 Wpressure die cast aluminium housing/Body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, including electricconnection with suitable size of wire from junction box tostreet light fitting, fixing the light fitting with and including bracket made out of GI tubing lightgrade 32mm dia, 1.2, metre long bent to shape at 120 degree angel at half metre from bottom, including two Nos clamps made out of MS Flat iron of size 25x4 mm with suitable nuts and bolts for fixing of bracket including paintingto MS clamp and nut bolts withtwo coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed |
| 6 | S&F cable junction box of size 200mm x 160mm x 110mm or any otherhigher size (Suitable for Pole mounting ) complete with fixing accessories and should be insulated and made out of polycarbonate with glass fibre reinforced material having IP-65 protection accordance with IEC 60259, fixing with and including SS-304clamp of size 25X3mm including suitable nut bolts and washers and complete with following specifications and as directed (a) junction Box must meet the provision laid down in IEC 60998-1, 60670-22 to 5 and colour according to RAL-9011/7035 (b) The manufacturer of junction box shall submit a copy of IEC certificate.(c) Junction box shall be fire retardant and self-extinguishing in accordance with IEC-60695-2 to 11, DIN VDE 0304 Part-3, UL94 V-2 flammability standard. It should be tested at glow wire test for 960 degree. (d) The degree of protection of enclosure against mechanical load shall be in accordance with EN 50298 for Ik08(e) Internally embedded gasket of polyurethane/extruded silicon gasket.(f) Junction box shall have 4 pole complete with single pole MCB \"C\" curve of 6Amp rating |
| 7 | Supply, laying and testing XLPE Insulated screened PVC bedded galvanised steels strip or wire armoured electric power cable heavyduty with aluminium conductorcross section area 16 sqmm 4 core cable, 1100 volts heavy duty cable complete all as specified |
| 8 | S&F three core (3X2.5 sqmm) flexible flat/ round cable, copper conductor multi-stranded, PVC insulated and overall PVC sheathed, 1100 volt, drawn through & including Rigid non-metallic PVC conduit inclusive of all tees, bends , elbows, reducers, bell mouth tube ends, junction box and fixing accessories such as couplers, lock nuts, saddles, pipe hooks, electric connector etc. laid in ground complete all as specified and directed |
| 9 | S&F sheet metal enclosure for DB\"s SPN 230 volts 4 way double door complete all as specified and directed |
| 10 | S&F240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SPN and current carrying capacity 32 Amp in the MCB DB complete with connection testing and commissioning complete all as specified |
| 11 | S&F 240V , 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB complete with connectiontesting and commissioning complete all as specified |
| 12 | Supply, install testing and commissioning weather and vermin proof LT feeder pillar box (Panel Board) factory fabricated outdoor type totally enclosed made out of 3 mm thick sheet metal enclosure of suitable size, with angle iron frame of MS angle 50 X 50 X 6 mm suitable for operation on 3 Phase 4 wire, 440 volts 50 Hz system , with hinged panel doors (covers ) on two sides with handles, bottom gland plate and locking arrangement consisting suitable and sufficient Nos circular cable entry holes at bottom only with suitable PVC/Rubber bushes to prevent ingress of water/ rubber bushes to prevent ingress of for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated (15 micron) grey hammer tone with one coat of including connecting with LT armoured incoming and outgoing cables and including required sizes of cable lugs and angle iron stand with PCC work complete all specified and directed and consisting following.(a) Aluminium bus bar of 150 Amp current rating capacity, lengthas actually required at site for 3 phase and neutral, mounted on epoxy/FRP bus bar insulator(b) MCCB 63 Amps 4 Pole 16 KA, 415 V - 01 No for incoming(c) MCB 32 Amp 4 pole 10 KA , 415V-03 No for outgoing (d) MCB SPN 32 Amp 10 KA 230 V - 03 Nos for outgoing (e) Digital multifunction meter for indication of current, voltage etc with necessary CTs - 01No(f) LED type indicator lamp Red/ Yellow / Bluecolour -01 set (g) Necessary internal wring with copper conductor incl lugs and thimbles |
| 13 | Supply and laying double wall corrugated pipe (DWCP) size of 50/38, Non-metallic resistanced to compression typo 450, resistance to impact, normal, resistance to bending pliable resistanced to external influence,ingress protection: IP 67, resistance against corrosion: without protection, resistance to flame propagation, non flame propagation conforming to IS-16205 (part-24) 2017 including necessary jointing material le snap fit coupler with ruvver ring, sealing plug, tees , bend, angle bend etc for passing electrical cable complete all specified and directed. |
| 14 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting outsoft/ loose soil and making good disturbed surfaces complete all as specified and directed |
| 15 | Returning, filling in , including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.. |
| 16 | Removing excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.Note :-A Sum of Rs. 4,970.00 will be deducted on account of credit for dismantling/ demolished/ taking down material. Please refer detail on srl page No. 18 (Schedule of credit) of Tender Documents. |