| Sl. No. | Item Description |
| 1 | M&L for Surface dressing n exc 15 cm deep and Site Clearance completeall as specified and directed. |
| 2 | Excavation in trenches in any type of soil not exc 1.5m wide and not exc 1.5m in depth and getting out in any type of soil complete all as specified. |
| 3 | Excavating over areas, exc 1.5 m and n exc 3 m deep and getting out soft/loose soil completeall as specified and directed. |
| 4 | M&L for PCC 1:4:8 type D2 ( Using 40mm graded agg) as in foundation and mass concrete complete all as specified and directed. |
| 5 | M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter completeall as specified and directed. |
| 6 | M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings,girders, bressummers,lintels, cantilevers, shelves including sup- ports, overhangs,etc. also splays between floors and beams, etc. completeall as specified and directed. |
| 7 | M&L for Formwork to sides of pillars,posts, struts, piers, columns and stanchions, etc. completeall as specified and directed. |
| 8 | M&L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified. |
| 9 | M&l for Mild steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders completeall as specified and directed. |
| 10 | M & L forReinforced cement concrete (design mix) inM-25 (20 mm graded aggregate)Foundations, including rafts,footings,foundation beams; plinth beams; bases for columns, etc.; basement slabs,under-reamed piles and mass concrete completeall as specified. |
| 11 | M & L forReinforced cement concrete (design mix) inM-25 (20 mm graded aggregate)Beams, cantilevers, bressummers,lintels over 1.5m span completeall as specified. |
| 12 | M & L forReinforced cement concrete (design mix) inM-25 (20 mm graded aggregate)Columns, pillars, piers, posts and struts completeall as specified. |
| 13 | Returning filling soft/loose soil including spreading leveling watering and well rammingin layers not exceeding 25 cum all as specified. |
| 14 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point |
| 15 | Earth filling under floors, spreading, levelling in layers n.exc 25cm thick each incld watering & well ramming as specified. |
| 16 | M&L Damp proof course 40 mm th in cement concrete 1:2:4 type B-2 to horizontal or vertical surfaces including necessary formwork |
| 17 | M & L for Damp proof course, Bitumen blown any grade, applied hot, two coats, to concrete surfaces at the rate of 1.5kg. per sq. m per coat and Polythene film, black, 50micron laid in floors complete all as specified and as directed. |
| 18 | M & L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, build in CM (1:6) complete all as specified and as directed. |
| 19 | M & L for brickwork with fly ash bricks, straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 completeall as specified and directed. |
| 20 | M & L for rendering 15 mm thickfair face of brick/concrete surfaces work in CM 1:6 finished even and smooth without using extra cement completeall as specified and directed. |
| 21 | M & L for rendering 15 mm thick on fair face of brick work or concrete surface in CM 1:4, finished even and smooth without using extra cement completeall as specified and directed. |
| 22 | M & L for Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification.over a coat of plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth. Two or more coats on new work |
| 23 | M&L for preparation of new surfaces andMaterial & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 24 | Hard core of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick watered and well rammed to a true surface. |
| 25 | M&L for 75 mm thick cement concrete type C-2, 1:3:6 (40mm graded agg) as in Sub-base to floor finishes. |
| 26 | M&L for cement concrete type C-2, 1:3:6 (40mm graded agg) 75mm thick as in plinth protection, pavement, etc. and finished the surface even and smooth without using extra cement. |
| 27 | M&L for Virified double charged tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes complete all as specified and as directed. |
| 28 | M&L for Vitrified Double charged tiles 10 mm thick (square/ rectangular) polished, area of each tilesexceeding 0.42 sqm but not exceeding 1.0 sqm, as in skirting/ dadoo etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick plaster in CM(1:4) complete all as specified and as directed . |
| 29 | Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular)of size 300 x 300 mm, joint free tiles, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15 mm th screed bed or bedding layer of mortar in CM 1:4, complete all as specified. |
| 30 | Coloured glazed ceramic tiles of size 450 x 350 x 7 mm thick as in vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match, over 10mm thick plaster in CM(1:3) on fair face of brick or concrete surface complete all as specified and directed. |
| 31 | M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like incl 20mm th screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granitecomplete all as specified and as directed . |
| 32 | M&L Reinforcement cement concrete (nominal mix) type B0-1:2:4 (12.5 mm aggregrate) inSlabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like |
| 33 | S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing. |
| 34 | S&F Factory made decorative lamination finish single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/ Chowkhat of size 65 x 125 mm comprising of virgin PVC polymer of K value 58- Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. . Note: (a) For WPC solid door/window frames,minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable.Variation in profile dimensions on plus side shall be acceptable but no extrapayment on this account shall be made.(b) The quoted rate shall be inclusive of required size and dia of M.S. hold fast/ lugs or SS dash fasteners. |
| 35 | S&F factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture, proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. Note: (a) Stainless steel butt hinges and necessary S.S screws shall be paid separately |
| 36 | Supply & Fixing SS Butt hinges medium weight cold rolled & fixed 100 mm long |
| 37 | S&F Aluminium anodised barrel tower bolts of extruded section with 150 mm long bolt complete all as specified . |
| 38 | S&F Aluminium alloy, anodised, sliding door bolt 250mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified. |
| 39 | S&F Aluminium handles, cast type, anodised of size 150mm complete all as specified. |
| 40 | Providing and fixing undermentioned factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc.all complete as per approved drawing & direction of Engineer-in-Charge.Three track three panels sliding window made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thicknessof 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. |
| 41 | Providing and fixing undermentioned factory made uPVC white colour sliding glazed window/ventilators upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc.all complete as per approved drawing & direction of Engineer-in-Charge.Two track two panels sliding window/ventilator made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9± 0.2 mm and single glazing bead of appropriate dimension. |
| 42 | Note for items no. 40 and 41(a) After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality and the quoted rate shall be inclusive of the same.(b) Single / double glass panes, wire meshshall be paid separately). (c) Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.(d) Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc.(e) For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. |
| 43 | S&Fin repair bib tap cast copper alloy fancy type chromium platedscrewed for 15mm bore completeall as specified and directed. |
| 44 | S&F in repair Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or unioncompleteall as specified and directed. |
| 45 | S&F in repair Pillar taps, cast copper alloy chromium plated, fancy type, screwed down, high pressure single leverwihout popup waste with waste with 450 mm long braided hoses screwed shanks and fly nut of 15mm bore. |
| 46 | S&F in repair concealedstop cock with fitting sleeves,operating lever &adjustable wall flange with seal valvescast copper alloy chromium platedwith long shank and cup (concealed type) fancy type screwed down high pressurescrewed both ends for pipe completeall as specified and directed. . |
| 47 | S&Fin repair Anglurstop cock cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for pipe or union fixed for 15mm bore) completeall as specified and directed.. |
| 48 | S&F in repair Towel ring square with round flange CP Brassall as specified. |
| 49 | S&Fin repair Towel rack 600 mm Long with Lower Hangers Superior finishedCP Brassall as specified. |
| 50 | S&Fin repairs Vitreous china premium/ 1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) complete in all respect all as specified. |
| 51 | S & F in repairs PVC 10 ltr. Cap. valveless syphonic action type, flushing cictern, low level, white/ coloured with inlet, ball valve, float and handle including brackets and 32 mm flushing pipe connection to pipe etc.completeall as specified and directed. |
| 52 | S&Fin repair glass shelf assembly completeall as specified and directed. |
| 53 | S&F in repair soap dish holder completeall as specified and directed. |
| 54 | S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 55 | S&F in repair 600mm x 450mm bevelled edge mirror of selected quality glass withPVCbacking as approved BY GE fixed to wall tiles/wall to slicon paste including necessary fixing arrangement completeall as specified and directed. |
| 56 | S&Fin repairVitreous Cliina wash basin, angle back, size 600x480mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets completeall as specified and directed. |
| 57 | S&F PVC connection 60 cm long fitted withPTMT nut andwasher on both ends, fixed to 15 mm bore iron pipes completeall as specified and directed. |
| 58 | Supply and layingin repair of CPVCpipes16mm dia outer boreSDR 11 &plain CPVC SDR 11 fittings/special fittings onwalls /ceilings or laying in floors complete all as specified. |
| 59 | Supply and layingin repair of CPVCpipes20 mm dia outer boreSDR 11 &plain CPVC SDR 11 fittings/special fittings onwalls /ceilings or laying in floors complete all as specified. |
| 60 | M & L PVC (SWR) floor trap/Nahani trap with grating including jointing with solvent cement dia of outlet in 75 mm completeall as specified and directed. |
| 61 | S&F 75 mm bore, PVC(SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor complete all as specified and as directed. |
| 62 | S&F 75 mm bore, PVC(SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed. |
| 63 | S&F 110 mm bore, PVC(SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor complete all as specified and as directed. |
| 64 | Supply & Fix 110mm bore PVC(SWR) vent cowl all as specified and as directed. |
| 65 | S&F 110 mm bore PVC (SWR) pipes single socketed inany length withrubber ring joints fixed to walls |
| 66 | S&Fin repair for Rotational moulded polythylene water storage tank (ISI marked multilayer) with float valve, plastic lid cover, double layered, cylindrical vertical with closed top, hoisted and fixed in position of capacity 500 ltrs includingdismantling old unserviceable tank and making connections inlcuding suitable GI wash out, over flow, nipple and including 20mm bore ball valve (minimum weigth of valve 210 gms) high pressure of PTMT with epoxy coated aluminium rod and high density plasic ball screwed for iron pipe and fixedcomplete all as specifed and directed. |
| 67 | S&F forin repairSS Gratings 100mm dia with/ withoutwaste hole, complete complete all as specified and as directed by Engr-in-Charge. |
| 68 | Material and labour Reinforced concrete pipes150 mm bore, class NP2,laid and jointed complete with collar laid in trenches and jointed in cement mortar 1:1 complete all as directed and specified. |
| 69 | Material & labour cement concrete (1: 3 : 6 ) type C-2 with using 40 mm grade stone aggregate for bed to 150 mm dia Sewage pipes including packing underand haunching against the sides ofpipes afterthey are laid and tested complete all as directed. |
| 70 | M&L for cement concrete type B-0,1:2:4 (12.5mm graded aggregate) as in coping incl surface channel of drain and manhole necessary formwork complete |
| 71 | M&L for RCC 1:2:4 type B1 as in precast cement concrete cover slab (Slab of manhole/septic tank/soak well etc) and set in CM 1:4 all as directed. |
| 72 | M&L Cement concrete type C2-1:3:6(20 MM graded aggregate)in surface channels and drains |
| 73 | M&L for 75 mm thick cement concrete type C-2, 1:3:6 (40mm graded agg) as in Sub-base to floor finishes. |
| 74 | M&L for coloured vitrified heavy duty tiles dark shade (premium quality) of size 300mm x 300mm x 10 mm thick (square/ rectangular) polishedas in steps/stairs/raiser/vertical surface etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, laid over and including 15 mm thick screed bed in cement mortar (1:6) aftercomplete all as specified and directed. |
| 75 | S&F structural steel work as in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 |
| 76 | M&L steel work as inhand rails, wind ties for roof includingsecuring bolts, posts and struts in fencing including cutting top to shape as directed drilling holes, notching for wire etc flat iron fillets for securing wire mesh etc including all necessary drilling bolting or riveting etc and similar work confirming to Fe-290 Gde E-165 |
| 77 | Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550Mpaas in roof covering / cladding to wall, fixed with self tapping screws as specified. |
| 78 | Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550Mpaas in roof covering / cladding to wall, fixed with self tapping screws as specified. |
| 79 | M&LPlates Fe-410-W(Gde-E-250) quality-B (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed. |
| 80 | M&L Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer. |
| 81 | M&Lfor 4 mm thick Non asbestos fibre cement builing board fixed in ceiling or laid/Aluminium frame work with Aluminium powder coatedsnap grid frame work as in false ceiling all as specified size of grid 605 X 605 mm with aluminiummain T section of size 36.5 X 25 mmX 1.4mm weighing 0.24 kg per running metreand cross T of size 23.5 X 26.4 X 1.4 mmweighing 0.191 kg per RM with aluminium wall angle of size 40 X 25 X 2 mm including GI supporting wire of 3mm dia . complete all as specified and as directed. |
| 82 | M&L forPCC type B-2, (1:2:4) using 40mm graded stone aggregate, concrete fdn complete all as specified and as directed. |
| 83 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbishoff the premisescomplete all as specified and as directed by Engr-in-Charge. |
| 84 | M&L for complete removal of existing treatment and applying 1mm th layer of wall care putty (Birla white or equivalent) over a coat of primer and then applying two coats of oil bound distemper after preparation of wall surfaces complete all as specified and directedby Engr-in-Charge. |
| 85 | M&L for concealed Point wiring including cutting and chasing on wall / roof surfacecontrolled by one switch with 1.50 Sqmm (nominal area) FRLS, PVC insulated 1100 volts grade multi stranded copper conductor single core unsheathed cableandFRLS, ISI marked, PVC insulated 1100 volts grade multi stranded copper conductor single core of size 1.50 Sqmm as earth continuity conductor connected to common earth dolly, not less than 1.50mm thick, drawn through in and including rigid PVCconduit (Medium Grade) of suitable size, with all fittings, ISImarked and accessories, the pipe shall be fixed with clamping and shadle including provision of mild steelterminal boxes/Sunken boxes of suitable size made with 1.22 mm thick mild steel sheet recessed in wall with a coat of black bituminus paint and providing of with 3mm thick bakelite/PVC sheet ISI marked top cover , suitable for fixing of switches / sockets / regulators etc.fixed in recess of wall with brass chromium plated screws and cap washer complete all as specified and directed for the following :- |
| 86 | (a) One light point controlled by one way switch 5/6 amps. |
| 87 | (b) One ceiling fan/Exhaut fan point controlled by one way switch 5/6 amps. |
| 88 | (c)One socket out let 5/6 amps point on the independent board |
| 89 | (d)One socket out let 5/6 amps point on the same board |
| 90 | (e) One bell point controlled by one way switch 5/6 amps. |
| 91 | All as per item No 84 above but wiring with 4.00 sq mm single coremultistranded copper conductor for one socket out let 15/16 amps and ACpoint on the independent board complete all as specified and directed |
| 92 | S&F of Modular switch, single pole, one way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed. |
| 93 | S&F of Modular switch, single pole, one way, 16 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed. |
| 94 | S&F of Modular shuttered Socket outlet 5 Pin, 6 Amp, 2 Module, 230 volts, ISI marked complete all as specified and as directed. |
| 95 | S&F of Modular shuttered Socket outlet 6 Pin, 6/16 Amp, 2 Module, 230 volts, (ISI marked) complete all as specified and as directed. |
| 96 | S&F of Modular bell push, one way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed. |
| 97 | S&F of stepped type modular electronic fan regulator 120 watt 2 module suitablefor 1200/1400 mm sweep energy saving fans,ISI marked complete all as specified and directed. |
| 98 | S & Flamp holder, insulated body, with back plate suitable for batten/anglefittings complete all as specified and directed. |
| 99 | S&FLED white glass Lamp 1x9 Watt 230V Base-22 complete all as specified and directed. |
| 100 | S&F in ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed. |
| 101 | S&F IP 20, class I, LED light 1X18 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified. |
| 102 | S&F IP 20, Class I, LED Mirror light fitting 1 x 10 W, (or nearest next higher wattage) 5700 K, wall /Surface mounted with aluminium housing 2 feet long, integrated type, with high efficiency PMMA diffuser,integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy > 95 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/square blocks, screws etc complete including 01 No 10 W LED lamp with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size including necessary taking down the old unserviceable fitting complete all as specified. |
| 103 | M&L for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 Security light fitting luminaire with high power LEDs as light source and driver of capacity 35 watts withpre wired and nacessary mounting arrangements, provision of new 3 core multistranded copper conductor cabe from ceilling rose to fitting and GI Pipe bracket made out of GI pipe medium grade 0.75 Mtr long 32 mm dia , MS clamp, nut, bolt and washers complete all as specified and directed by Engineer-in-charge. |
| 104 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver threecore flexible copper conductor cases of suitable size complete. |
| 105 | Materialand labour for concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits &making good to walls, floors etc complete, including taking down old unsv aluminium submain wiring all as specified and as directed. NOTE: Two runs of 6 sqmm conductor for main and one run of 6 sqmm conductor as earth wire with proper colour coding including one run run of PVC conduit shall be measured as one unit length. Connections of cables wit MCBs or bus bar shall be done through appropriate size brass/ copper thimbles |
| 106 | S & F of MCB, DB Vertical TPN, 415 volts 8 ways Single DOOR, IP-43, with MCCB Incomer, metal door, rated bus bars, earth bar, neutral links complete incl. blanking plates as required & fixed flush to wall/other surface complete all as specified and as directed. |
| 107 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), single door, single pole & neutral with 200 amps rated bus bar, 240Volt IP-43 protection suitable for fixing MCB\"S/lsolatorscomplete all as specified and directed. |
| 108 | S&F MCB, Triple pole & neutral 100 amps, 240 volts, ‘C’ curve, 10KAcomplete all as specified and as directed. |
| 109 | S&F MCB, Single pole & neutral, 32 to 63 amps, 240 volts, ‘C’ curve, 10KA allcomplete with and including taking down old unsv one as specified and as directed. |
| 110 | S&F MCB, Single pole, 5 to32 amps, 240 volts, ‘C’ curve, 10 KAall complete with and including taking down old unsv one as specified and as directed. |
| 111 | Material and labour for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, checknuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, includig necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 5 of SSR Part- I including testing on completion all as directed and as specified. |
| 112 | Supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including fixing clamp and with all accosaries. |
| 113 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm all as specified and as directed. |
| 114 | Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built infilter for better indoor air quality with Timer, minimum 5 star rating and EER 3.2 of capacity 1.5 TR incl all fixing accessories such as holding Metal bracket,nut bolt all as specified and as directed. |
| 115 | S&F epoxy powder coated sheet metal enclosure with socket plug top and MCB, single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps, 240 Volts, C Series current carrying capacity 10 kA, incl necessary connection complete all as specified and directed. |
| 116 | S&F Modular white cover plate with frame 1 module complete all as specified and directed. |
| 117 | S&F Modular white cover plate with frame 2 module complete all as specified and directed. |
| 118 | S&F Modular white cover plate with frame 3 module complete all as specified and directed. |
| 119 | S&F Modular white cover plate with frame 6 module with blank switches as required complete all as specified and directed. |
| 120 | S&F Modular white cover plate with frame 8 module with blank switches as required complete all as specified and directed. |
| 121 | Voltage stabilizer for automatic operation,single phase naturally air cooled indoor wall mounted type fully elecronic controlled & designed for input variation between 150 V to 285 V with output voltage stabilized at 230 V with accuracy of ± 2.5 % and of capacity 5.0 KVA. |
| 122 | Schedule of Credit |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |