Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Schedule \"A\" Part-I (B/R Work) |
| 2 | S&F in repairs 32 / 40mm bore CP waste coupling (half or full threaded) for discharge pipe (minimum weight 45gms) complete all as specified and directed. |
| 3 | S&F in repairs 32/40 mm dia bore PVC flexible pipe for wash hand basin / urinal, complete all as specified and directed. |
| 4 | S&F in repairs 15mm size PVC connections with PTMT nuts of length 600mm, complete all as specified and directed. |
| 5 | S&F in repairs 100mm dia CP grating doom, complete all as specified and directed. |
| 6 | S&F in repairs 125mm dia CP grating doom with waste hole, complete all as specified and directed. |
| 7 | S&F in repairs CP Health faucet fixed with spring action and lever along with flexible shower hose with brass nut of length 1.5m fitted in the existing water connection in the toilets, complete all as specified and directed. |
| 8 | S&F in repairs CP Jet Spray of Standard size for EWC alongwith CP connection and all fittings as fixed, complete all as specified and directed. |
| 9 | S&F in repairs 600mm long towel rail of PTMT fixed with and including chromium plated brass screw and wooden / plastic cleats(minimum weight 190gms), complete all as specified and directed. |
| 10 | S&F in repairs plastic water closet seat cover closed pattern with flat bottom cover and mild steel chromium plated or aluminized hinging device, complete all as specified and directed. |
| 11 | S&F in repairs 15mm bore bib tap, cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed for iron pipe or for brass ferrule, complete all as specified and directed. |
| 12 | S&F in repairs 15mm bore Stop valve / angle valve, cast copper alloy, chromium plated, fancy type, screwed down high pressure with capstan head, complete all as specified and directed. |
| 13 | Attending complaints related to plumbing / water supplyand obtaining completion from user including minor repair such as replacement of washers, tightening of taps, tightening of check nuts / unions / sockets / PVC connection etc and making water supply functional in case of blockage, refixing of GI pipe joints, application of white cement where required, complete all as specified and directed. |
| 14 | Attending complaints related to carpenter work and obtaining completion from user including repair/easing of doors re-fixing or tightening of doors, windows, resecuring of door/window wire guage, (fixing only) builders hardwares, helical door spring including use of all types ofnails, screws etc which are required to make good the work, complete all as specified and directed. |
| 15 | Taking down aluminium door / window shutter of any size n exc 2.5 Sqm each & refixing in the same position / opening after easing and adjusting, tightening of joints or changes of hinges, screws, cleats, beadings, rubber gasketetc, as per site requirement to make functional the shutter, complete all as specified and directed. |
| 16 | Taking down and refixing of shutters in same openingafter easing and adjusting of any description exc 1 Sqm and n exc 2 Sqm each including resecuring / changing of builders hardware, complete all as specified and directed. |
| 17 | S&F in repairs PVC syphon kit, complete all as specified and directed. |
| 18 | S&F in repairs 15mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic bal screwed for iron pipe (minimum weight 142 gms), complete all as specified and directed. |
| 19 | S&F in repairs 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic bal screwed for iron pipe (minimum weight 210 gms), complete all as specified and directed. |
| 20 | S&F in repairs brass spindle of full or half turn for taps/ stop cocks/ pillar taps/ CP mixer etc,complete all as specified and directed. |
| 21 | S&F in repairs 250mm mild steel helical door spring rat tail type including collar plate and welding if required or otherwise fixed with screw on wooden frames, complete all as specified and directed. |
| 22 | S&F in repairs 150mm size Aluminium anodised, barrel tower bolts of extruded section, complete all as specified and directed. |
| 23 | S&F in repairs 100mm size Aluminium anodised, barrel tower bolts of extruded section, complete all as specified and directed. |
| 24 | S&F in repairs 150mm size Aluminium handles, cast type, anodised complete all as specified and directed. |
| 25 | S&F in repairs 100mm size Aluminium handles, cast type, anodised complete all as specified and directed. |
| 26 | S&F in repairs 100mm long floor door stopper of aluminium alloy body and tongue with rubber cover ends, complete all as specified and directed. |
| 27 | S&F in repairs 100mm long medium weight, cold rolled mild steel Butt hinges, complete all as specified and directed.. |
| 28 | S&F in repairs 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts, complete all as specified and directed. |
| 29 | S&F in repairs 12mm thick designer particle boards or tiles for insulation and acoustic purposes, 60cm x 60cm in size, including painting of matching colour of existing surface, complete all as specified and directed. |
| 30 | S&F in repairs 6mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame work, complete all as specified and directed. |
| 31 | S&F in repairs 15mm bore hot and cold water mixer with swan neck for WHB chromium plated quarter turn screwed down, including necessary fittings, complete all as specified and directed. |
| 32 | S&F in repairs 15mm size sink mixer for mixing hot & cold water, cast copper alloy chromium plated with capstan heads, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe, complete all as specified and directed. |
| 33 | S&F in repairs 15mm bore chromium plated wall mixer 3-in-1 system wall mixer with overhead and hand shower arrangement with connecting legs, wall flanges and wall bracket for hand shower, complete all as specified and directed. |
| 34 | S&F in repairs 10 litre capacity PVC valveless, Syphonic action type, flushing cistern low level, white with inlet ball valve, float and handle including brackets and PVC flush pipe etc., complete all as specified and directed. |
| 35 | S&F in repairs vitreous china wash basin white flat back,size550x400 mm, with & including 32mm dia PVCwaste pipe and waste coupling with & including angle iron brackets of suitable size & length or erecting stand etc., complete all as specified and directed. |
| 36 | S&F in repairs Vitreous china squatting pan, Orissa pattern, of size 580 x 440mm, white, white with integral foot rest and P or S trap (Excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etc. and cement concrete bedding complete all as specified in SSR, complete all as specified and directed. |
| 37 | S&F in repairs Vitreous China wash down water closet pan (pedestal pattern),white (excluding flushing cistern ) including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, PVC cover sheet in same colour etc., complete all as specified and directed. |
| 38 | S&F in repairs for 15mm bore tubes, medium grade, galvanised, with all fitting, ( such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc.) and fixed complete to and ceiling with clips, wall hooks, wooden plugs or laid in floors including screwing and waste and for forged bends on piping as required, complete all as specified and directed. |
| 39 | S&F 500 litres capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic bal screwed for iron pipe (minimum weight 210 gms) including dismantling existing water tank and removing from site, complete all as specified and directed. |
| 40 | S&F 1000 litres capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic bal screwed for iron pipe (minimum weight 210 gms) including dismantling existing water tank and removing from site, complete all as specified and directed. |
| 41 | Cleaning and removing all scale and dirt, etc. from tanks and from mouths of circulating pipes, etc of capacity upto 500 litres and refixing the float valve with plugging including writing letter i.e. \"TANK CLEANED ON ......................(Date)\" not exc. 100mm height with synthetic enamel paintand wash tank in every 3 months, complete all as specified and directed. |
| 42 | Cleaning and removing all scale and dirt, etc. from tanks and from mouths of circulating pipes, etc of capacity exc 1000 litres and upto & including 2000 litres and refixing the float valve with plugging including writing letter i.e. \"TANK CLEANED ON ......................(Date)\" not exc. 100mm height with synthetic enamel paintand wash tank in every 3 months, complete all as specified and directed. |
| 43 | S&F in repairs for 600mm x 450mm bevelled edge mirror of selected quality glass mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed |
| 44 | S&F 3mm thick sheet glass ordinary quality and glazing with oil putty / wooden beading in squares not exceeding 0.50 Sqm including hacking old glass, complete all as specified and directed. |
| 45 | S&F in repairs 20 mm dia stainless steel drapery rod standard quality including steel funnel and steel brackets, complete all as specified and directed. |
| 46 | S&F in repairs sink with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm, complete all as specified and directed. |
| 47 | Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) exc. 1.5 Sqm but n exc 4.0 Sqm and credited to the contractor, complete all as specified and directedNote: The damaged portion of the tiles / rendering shall be made good with the same material to match with the adjacent surface. |
| 48 | S&F pressed steel frame for doors with one rebates size of frame 125x60 mm including necessary fixing lungs hinges lock strike plate etc. including PCC, 1:3:6, type C-0 (using 12.5 mm graded crushed stone aggregate) as in back filling of pressed steel frame, complete all as specified and directed. |
| 49 | S&F 35mm thick 2nd class hardwood plain framed, panelled shutter (two panel), factory made, with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, complete all as specified and directed. |
| 50 | S&F 35mm thick 2nd class hardwood, factory made, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a), complete all as specified and directed. |
| 51 | S&F 150mm size Aluminium handles, cast type, anodised, complete all as specified and directed. |
| 52 | S&F 150mm size Aluminium anodised, barrel tower bolts of extruded section, complete all as specified and directed. |
| 53 | S&F 250mm aluminium alloy, anodised, sliding door bolt with hasp, staple & fixed clips of sheet, cast or extruded section & fixed bolts & sliding bolts of extruded section or cast aluminium alloy, complete all as specified and directed. |
| 54 | S&F mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18 in steel / wooden shutter of door & windows, complete all as specified and directed. |
| 55 | Preparation of new wood and wood based surfaces of any description exc 10cm with or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed. |
| 56 | Taking down shutters of any description size of shutter exc 1 Sqm but n.exc 2 Sqm and removing from site complete all as specified and directed. |
| 57 | S&F 30mm thick Factory made Solid Panel PVC Door Shutter (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing, complete all as specified and directed. |
| 58 | S&F 100mm size Aluminium handles, cast type, anodised, complete all as specified and directed. |
| 59 | S&F 100mm size Aluminium anodised, barrel tower bolts of extruded section, complete all as specified and directed. |
| 60 | S&F 100mm long butt hinges, medium weight, cold rolled mild steel, and fixed, complete all as specified and directed. |
| 61 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 62 | M&L framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings conforming to Fe-290 (GdeE165) (exclusive or steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing, complete all as specified and directed. |
| 63 | M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St-240, complete all as specified and directed. |
| 64 | S&F in repairs 0.63mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, with L-type or J-type or cranked hook bolts, in roofs, walls etc. with grade of zinc coating, complete all as specified and directed. |
| 65 | S&F in repairs 0.63mm thick Galvanised, Plain mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating, complete all as specified and directed. |
| 66 | Preparing new zinc (or galvanised) surfaces to receive painting of any description over 10cm width or girth, by coating with mordant solution including washing and cleaning, etc. steel and iron surfaces and applying two coats of synthetic enamel paint over one coat red oxide primer, complete all as specified and directed. |
| 67 | Preparation of new steel surface and iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over red oxide primer, complete all as specified and directed. |
| 68 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and directed. |
| 69 | M&L for brick work with sub-class `B\" bricks (using old size bricks), straight or curved on plan exceeding 6m mean radius built in CM 1:6, Complete all as specified and directed. |
| 70 | All as per Ser item No 68.00 here in before but except bricks. |
| 71 | M&L for brick work with sub class \"B\" bricks (using old size bricks) straight or curved on plan to any radius in half brick thick wall radius, built in CM 1:4, complete all as specified and directed. |
| 72 | M&L 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 and finishing even and smooth without using extra cement using integral water proofing compound, complete all as specified and directed. (WPC shall be measured and paid separately). |
| 73 | Preparation of new surface of wall and applying two coats of cement base paint over one coat of primer, complete all as specified and directed. |
| 74 | M&L 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 and finishing even and smooth without using extra cement, complete all as specified and directed. |
| 75 | Preparation of newly plastered wall surfaces by using necessary filling compound of Altek/Birla white 1mm thick wall careputty to obtain smooth / even surface using sand paper and applying two coats of oil bound diameter over a coat of primer, complete all as specified and directed. |
| 76 | M&L for 10mm thick rendering on fair faces on brick or concrete surfaces in CM 1:6, fair finished the surfaces even and smooth without using extra cement including taking down cement plaster, complete all as specified and directed. |
| 77 | Preparation of old decorated plastered or unplastered surfaces of wall including filling of holes, cracks and undulating surface with cement wall care putty making surface even and smooth and applying one coat of distemper oil emulsion paint (OBD), complete all as specified and directed |
| 78 | Preparation of old decorated plastered or unplastered surfaces of wall including filling of holes, cracks and undulating surface with cement wall care putty making surface even and smooth and applying two coats of distemper oil emulsion paint (OBD), complete all as specified and directed |
| 79 | Preparation of old painted steel & iron surfaces of any description over 10cm width or girth and applying One coat synthetic enamel paint, complete all as specified and directed. |
| 80 | Preparation of old painted wood surfaces and wood based materials of any description over 10cm width or girth and applying one coat synthetic enamel paint, complete all as specified and directed. |
| 81 | Complete removal of existing treatment from brick walls or concrete surfacesincluding scraping down smoke soots, moulds, moss and trading oil and greasy spots etc including cornices, pilasters etc (Plastered or un plastered surfaces) and applying two coats of plastic emulsion paint over a coat of primer, complete all as specified and directed. |
| 82 | M&L for strong silicone sealant suitable for roof leak hole, metal leak, gap filling etc. hole size n exc 5x5mm including necessary fitting and scaffolding height upto 15m, complete all as specified and directed. |
| 83 | S&F artificial grass 35mm DL of 3 Tone (Pure green) colour any type of approved shades shall be SR sealant for joint filling etc complete all as per manufacturer instruction and as directed including taking down oldartificial grass, complete all as specified and directed. |
| 84 | S&F wall panelling / cladding of aluminium composite panel of any colour any type of approved shades made out of 3mm thick aluminium composite panel material consisting of 2mm thick mineral core sandwiched between two aluminium sheets (each 0.5mm thick). The aluminium composite panel wall panelling / cladding sheet shall be coil coated, with Kynar 500 based PVDF lumiflon based fluoropolyer resign coating of approved colour and shade on exposed face and polymer (service) coating on the face fixed over and including base frame fabricated with aluminium square pipe of size 25mm x 40mm with 1mm wall thickness including stainless steel screws, nuts bolts, washers cleats, weather silicone sealant for groove filling etc. complete all as per manufacturer instruction and as directed including taking down oldpanelling / cladding, complete all as specified and directed. |
| 85 | S&F in repairs 1.25mm thick of laths of steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, push pull or manual type, complete all as specified and directed. |
| 86 | Taking down the existing rolling shutters from the existing opening and refixing the same in position after carrying out necessary repairs including oiling, greasing, easing out etc., complete all as specified and directed. |
| 87 | S&F Ball bearing for rolling shutter complete all as specified and directed. |
| 88 | S&F Safety lever locks mild steel with 4 levers for rolling shutter complete all as specified and directed. |
| 89 | S&F in repairs aluminium powder coated aluminium window having three track (minimum thickness of powder coating 50 micron) with aluminium section 92mm X 31.75mm (Weight bottom section 1.070 kg/m, top section 0.933 kg/m, shutter section 40mm X 18mm (weight of handle section 0.417 kg/m) interlock 0.547 kg/rm mounted on bearing to slide on tracks plain anodized in approved shade including supply andfixing of 5mm thick plain glass and wire mesh, PVC track gasket, EPDM rubber gasket on glass of weather tightening along with locks, handle including sealing gap with marble surfaces with silicon sealants making it water proof in all manner etc. complete all as specified and directed. |
| 90 | S&F in repairs aluminium powder coated ventilator (minimum thickness of powder coating 50 micron) having fixed glass with aluminium section having section 50.80mm x 25.40mm (weight 0.489 kg/m) glazing clear section (weight 0.109 kg/m) with plain anodized including supply and fixing of 5mm thick plain glass making frame and glass water tightening making it good etc., complete all as specified and directed. |
| 91 | S&F for powder coated aluminium grill (Thickness or powder coating not less than 50 micron) of approved design / pattern, with approved standard section and fixed to the existing window frame with C.P. brass / stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved powder coated aluminium standard section around the opening, complete all as specified and directed. |
| 92 | Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. |
| 93 | M&L for Glazed ceramic tile 300x600x06-7mm thick (coloured) on vertical surfaces such as wall, dados etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 10mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 94 | M&L for Light shade Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 95 | M&L for Light shade Vitrified Ceramic tiles 8 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in Skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick backing coat CM 1:4, complete all as specified and directed. |
| 96 | M&L for 20mm thick granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick screed bed in CM 1:4 and including demolition of existing stone slab and tiles, complete all as specified and directed. |
| 97 | M&L for 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and direction. |
| 98 | Demolition of cement concrete (unreinforced) of any description in any position, complete all as specified and directed. |
| 99 | M&L for 75mm thick plain cement concrete, 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in sub base, complete all as specified and directed. |
| 100 | M&L for 75mm thick plain cement concrete, 1:3:6, type C-2 (using 40mm graded crushed stone aggregate) as in pavement / plinth protection, plinth protection shall be laid in alternate bays and joints shall be filled with bitumastic gola with 80/25 bitumen (1 part bitumen mixed with 3 part of sand) finishing surface even and smooth without extra cement, complete all as specified and as directed. |
| 101 | M&L for 20-25mm thick machine cut Kota stone slab flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing / grinding and polishing upto mirror finish complete over and including 20mm thick screed bed in CM 1:6, complete all as specified and directed. |
| 102 | M&L for 20-25mm thick machine cut kota stone slab as in riser of steps, skirting, dado and pillar jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing & polishing over and including 15mm thick backing coat in CM 1:6, complete all as specified and directed. |
| 103 | Schedule \"A\" Part-II (E/M Work) |
| 104 | Taking down carefully (copper/aluminum) unsv point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point ,socket point or power point includingfixture and fitting such as switches , ceiling roses, pendants , regulators , sockets , light fitting etc. removing material to store for keeping in safe custody or for taking credit( credit for above items should be made asper conditions seperately) and making good the disturbed surfaces of wall/floor or ceiling to match with existing surfaceand finishing the surfaces as per existing,complete all as specified and directed. |
| 105 | M&L for Point wiring for one light / fan point / exhaust fan controlled by one way switch on Independent boardwith 1.5 sqmm PVC insulated and unsheathed fire retardant low smoke and halogen (FRLSH) copper conductor single core multi stranded copper cable confirming to IS:694 (2010) using approved colour code for phase and neutral as per IS code drawn through non metallic PVC rigid concealed conduit heavy mechanical stress (HMS) grade in accordance with IS:9537 (Part 3) having wall thickness not less than 2.0mm thick and minimum 20mm external dia but shall be increased as per actual site requirement in accordance with clause No 19.125 of SI Part I ( ISI marked)including conduit accessories like bends, tees, junction boxes etc with all accessories suitable for modular/conventional type fitment, provision for fixing of modular flush boxes of appropriate size and dimensions for fixing ofpiano switches / sockets / regulator etc., including PVC insulated and unsheathed FRLSH 1.5 sqmm multi stranded copper conductor cable (green color) as continous earthlead wire connected to common earth and earth dolly, complete all as specified and directed. Note: (i) For concealed point wiring cutting chases for conduit shall be measured and paid seperately (ii) For sinking boxes cutting chases for conduit shall be measured and paid seperately |
| 106 | All as per Ser item No 103.00 here in above but 3 pin 6 Amps socket outlet point controlled by one switch on same board. |
| 107 | All as per Ser item No 103.00 here in above but 3 pin 6 Amps switch socket outlet point on independent Board. |
| 108 | All as per Ser item No 103.00 here in above but 2 way point wiring. |
| 109 | All as per Ser item No 103.00 here in above but bell point controlled by one bell push switch 6 amps 240 volts |
| 110 | All as per Ser item No 103.00 here in before but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmmfor 15 Amps power point. |
| 111 | S&F Modular switch 1 way, 6 Amp, 230 volts ,1 Module, complete all as specified anddirected. |
| 112 | S&F Modular switch 2 way, 6 Amp, 230 volts ,1 Module, complete all as specified anddirected. |
| 113 | S&F modular bell push switch with indicator 6 Amp 240 volte, 1 Module, complete all as specified and directed. |
| 114 | S&F Modular switch 1 way, 16 Amp, 240 volts ,1 Module, complete all as specified and directed. |
| 115 | S&F modular Socket6 Amp, 230 volts,5 Pin universal, 2 Module, complete all as specified and directed. |
| 116 | S&F Modular socket 6/16 Amp (euro socket), 250 volts, 2 Module, complete all as specified and directed. |
| 117 | S&F modular step type fan regulator suitable for 120 watt 250 volts, 2 Module, complete all as specified and directed. |
| 118 | S&F in repairs lamp holder / batten holder Polycorbonate type with back plate suitable for batten fitting including supply & fixing of 10 Watt retrofit lamp, complete all as specified and directed. |
| 119 | S&F Ceiling rose, surface bakelite 65 x 50 mm, 3 terminals fixed on PVC Round Block, complete all as specified and directed. |
| 120 | S&F in repairs 18/20 Watt (White/warm white) LED baton fitting 4 feet length including drivershaving energy consumption, 230 V ,50Hz, 6500K, not less than 800 lumen prewired, complete all as specified and directed. |
| 121 | S&F in repairs 9 Watt light fitting bulk head luminaries with lamp holders etc. complete with all accessories and including connecting up with twin core twisted flexible cable suitable size of 230V, 50HZ, complete all as specified and directed. |
| 122 | S&F in repairs LED 12 Watt fittings with surface mount, down lighters, including driver with rated voltage 240 V, 50 Hz, complete all as specified and directed. |
| 123 | S&F in repairs Energy efficient surface mounted 2\"X2\" grid Ceiling LED fitting 36/40W rated voltage 240 V, 50Hz combination with profiled and flat diffuse, complete all as specified and directed. |
| 124 | S&F in repairsLED baton fitting 2\" length including drivershaving energy consumption, 10/11W (White/warm white),230 V, 50Hz, 6500K, not less than 800 lumen prewired, complete all as specified and directed. |
| 125 | S&F in repairs building security lightLED25W with Lumen O/P 1800 with driver withrated voltage 240 V, 50Hz,including mounting GI (made out of 25 mm dia light grade pipe 0.8 m bent two shape including FI clamps nut bolts etc., complete all as specified and directed. |
| 126 | S&F sheet metal enclosure epoxy powder coated or polysterene insulated material double door type, vertical triple pole & neutral (VTPN) 4 Way with in built MCCB 125Amps ICs=ICu, 415 volts with 200 Amp rated bus bar flush /surface mounting double door, complete all as specified and directed. |
| 127 | S&F in repairs sheet metal enclosure MCB distribution board single pole & neutral, 240 volts, 08 way with IP-43 IK-09 protection double door complete with appropriate size bus bar, neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification, complete all as specified and directed. |
| 128 | S&F in repairs sheet metal enclosure MCB distribution board single pole & neutral, 240 volts, 12 way with IP-43 IK-09 protection double door complete with appropriate size bus bar, neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification, complete all as specified and directed. |
| 129 | S&F in repairs MCB triple pole and neutral ISI marked, C series, working on 415 volts 50HZ AC supply for incoming and outgoing controllingsystem capacity 63 Amps, 10 KA breaking capacity, complete all as specified and directed. |
| 130 | S&F in repairs 100 Amps MCCB, 3 pole 16 KA working on 415 Volts 50 HZ AC supply, complete all as specified and directed. |
| 131 | S&F MCBsingle pole ISI marked `C\" seriesworking on 240 volts 50HZ AC supply for incomming & out going controlling system of capaicty 63 Amps 10 KA breaking capacity etc all as specified and directed. |
| 132 | S&F MCB of single poles and current carrying capacity 6 to 32 Amp,240V, 10 KA \"C\" curve, in the MCB DB complete with connection testing and commissioning, complete all as specified and directed. |
| 133 | S&F MCBsingle pole and neutral ISI marked `C\" seriesworking on 240 volts 50HZ AC supply for incomming & out going controlling system of capaicty 40 Amps 10 KA breaking capacity etc all as specified and directed. |
| 134 | S&F MCBsingle pole and neutral ISI marked `C\" seriesworking on 240 volts 50HZ AC supply for incomming & out going controlling system of capaicty 63 Amps 10 KA breaking capacity etc all as specified and directed. |
| 135 | S&F in repairs metal clad plug & socket board single pole and neutral enclosure with 3 pin and earth plugs and socket complete with one single pole 20 Amps MCB, 415 Volts, C type, complete all as specified and directed. |
| 136 | S&F in repairs metal clad plug & socket board triple pole and neutral enclosure with 3 pin and earth plugs and socket complete with one triple pole MCB 32 Amps, 415 Volts, C type, complete all as specified and directed. |
| 137 | S&F 25 Litre capacity storage type water heater (Geyser), BEE 5 Star rated, vertical wall mounting type made out of CRCA outer body stainless steel storage tank, titanium enamelled heating element thermostat, thermal cutout, glass wool including 15 mm, 450 mm long (cold water pipe ), 15 mm, 450 mm long armourd pipe (hot water pipe) etc complete including making necessary electrical and water connections with 2.5 sqmm 3 core copper multistandred cable with top indicator plug top 15 amp from geyser connection to socket including hold fast for fixing of new geyser and writing the MES No. including taking down old unserviceable water heater (Geyser) and deposited to store yard of AGE E/M, complete as specified and directed. |
| 138 | S&F 6 Sqmm, two core aluminium service cable including taking down old unserviceable cable, complete all as specified and directed. |
| 139 | S&F ceiling fans complete with blades, down rods, electronic regulator and accessories 230V, 1200 mm sweep, minimum air delievery 210 CFM with service value 6.00, BEE 5 star rated with brushless direct current motor (BLDC) including taking down old unserviceable ceiling fans after disconnecting the wire from ceiling rose and deposited to store yard of AGE E/M, complete all as specified and directed. |
| 140 | Sub main wiring with three runs of single core PVC insulated multistranded un-sheathed FRLS cable of size 6.0 Sqmm with stranded copper conductor, drawing into concealed PVC conduit / surface batten (including PVC conduit of requisite dia and accessories) with one run of continuous PVC insulated multistranded unsheathed FRLS cable earth wire of size 6.0 Sqmm (in green volour) including taking out unserviceable sub main wiring, complete all as specified and directed. Note : Note : 3 runs of 6 sqmm copper cable & 1 run of 6 sqmm copper cable in and including 25mm PVC conduit shall be measured as one unit. |
| 141 | Sub main wiring with two runs of single core PVC insulated multistranded un-sheathed FRLS cable of size 4.0 Sqmm with stranded copper conductor, drawing into concealed PVC conduit / surface batten (including PVC conduit of requisite dia and accessories) with one run of continuous PVC insulated multistranded unsheathed FRLS cable earth wire of size 4.0 Sqmm (in green volour) including taking out unserviceable sub main wiring, complete all as specified and directed. Note : Note :2 runs of 4 sqmm copper cable & 1 run of 4 sqmm copper cable in and including 25mm PVC conduit shall be measured as one unit. |
| 142 | M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 metre deep below ground level) vertically, with top edge of the plate not less than 1.25 mtr below normal ground level, connected to galvanized iron wire 4mm dia by means of nuts, bolts, washers of GI steel all as shown on electrical plate No 3 of MES Schedule Part I connected to earthing test point and testing on completion with and including necessary excavation and earth work, earth electrode, earthing lead from electrode to equipment/substation, adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4)type B-1 (using 20mm gradedcrushed stone aggregate) 40mm thick cover, reinforced with 6mm dia bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 15 mm dia with funnel and wire mesh,and 40 mm dia GI light grade earth lead protection pipe, complete all as specified and directed.Note: (i) The unit rate includesmain earthing lead/strip from earth electrode to test point up to 7.5 meter (ii) In case measured value of earth resistance is recorded more than 1.0 ohms then the earthing shall be re done by the contractor without any extra cost to the department. |
| 143 | S&F in repairs 200 to 250mm sweep ventilation / exhaust fan, made out of plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding, complete all as specified and directed. |
| 144 | Supply, laying, jointing and testing XLPE insulated of cross sectional area 10 Sqmm 2 Core, PVC inner sheathed, armoured with galvanised steelstrip or wire, heavy duty, LT underground cable ISI marked with aluminium conductor 1100 volt grade laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking out existing old unserviceable cable, complete all as specified and directed.Note:- Earthwork, sand cushion, cable cover if required will be measured and paid separately under respective items of this Schedule. |
| 145 | Supply, laying, jointing and testing XLPE insulated of cross sectional area 16 Sqmm 4 Core, PVC inner sheathed, armoured with galvanised steelstrip or wire, heavy duty, LT underground cable ISI marked with aluminium conductor 1100 volt grade laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking out existing old unserviceable cable, complete all as specified and directed.Note:- Earthwork, sand cushion, cable cover if required will be measured and paid separately under respective items of this Schedule. |
| 146 | S&F in repairs LED post top light fitting 40W with all fixing accessories fitted on pilar or poles including making suitable foundation for anchoring in PCC 1:2:4, type-B-1, complete all as specified and directed. |
| 147 | S&F in repairs LED bollard lightlight fitting 10W with all fixing accessories fitted onincluding making suitable foundation for anchoring in PCC 1:2:4, type-B-1, complete all as specified and directed. |
| 148 | S&F in repairs 12 Watt LED focus light4 way outdoor wall, warm white, complete all as specfied and directed. |
| 149 | Deduction to be made from BOQ for Schedule \"A\" Part-III (Credit Schedule from dismantling / taking down items) worth Rs 1,41,865.00 during AOC. (Note :- Tenderers shall not quote for this Schedule) |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail