| 1 | Supply and erect in true vertical position 11.00m long steel tubular swaged poles complete with cast iron base plate, finial plug, bolts, nuts & screws as specified type 410 SP-55, painting of exposed surface of pole with two coats of aluminium paint over one coat of red oxide primer, painting up to 1.20m height above coping in alternate band ( 20 cm wide strip) with two coat synthetic enamel paint over one coat red oxide primer, marking Pole No. in 10cm dia coloured yellow circle, painting of pole below ground level with two coat anticorrosive paint including taking down old swaged pole, complete all as specified and directed. (Note:- Excavation, earth work and PCC will be measured and paid separately in respective items.) |
| 2 | M&L for PCC, 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling / mass concrete etc., complete all as specified and directed. |
| 3 | M&L for plain cement concrete 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate) as in coping for pole and the like, weathering, slightly rounded or chamfered angles including necessary form work, complete all as specified and directed. |
| 4 | S&F in repairs 210 Watt LED flood light, 230 V AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed. |
| 5 | S&F in replacement PVC insulated cu stranded (FRLSH) wire 2.5 sqmm, passing through the non metallic PVC conduit from junction box to LED security light terminals. All connections should be made with proper size of thimbles, complete all as specified and directed. |
| 6 | S&F in replacement of Rigid non-metallic PVC conduit of size 20mm dia exclusive of boxes (junction / terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc., complete all as specified and directed. |
| 7 | S&F in replacement PVC weather proof junction boxes of size 250 x 200 x 100mm (Inside dimentions) with PVC connector heavy duty connector 4 way 16 amps ,one No MCB SP 6 Amps and making necessary cable connection, complete all as specified and directed. |
| 8 | S&F in repairs LED post top light fitting 40W with all fixing accessories fitted on pilar or poles including making suitable foundation for anchoring in PCC 1:2:4, type-B-1, complete all as specified and directed. |
| 9 | Surface dressing / cleaning of surrounding area of 2/4 pole structure, TR plinth sub stn including removing of tree branches, small tree plants, tarbushes etc., complete all as specified and directed. |
| 10 | Labour for cutting the bushes and plants grown near the substation / structures premises using necessary tools and plants and removing the plants from the root level at any depth and cleaning the premises completely and making good the site suitable for spreading the stone aggregate including disposing all the waste to a distance not exc 50m form the site, complete all as specified and directed. |
| 11 | S&F in repairs MCCB 4 pole415 volts fixed type 100 Amps with breaking capacity 16 KA, complete all as specified and directed. |
| 12 | S&F in repairs MCCB 4 pole415 volts microprocessor release type, 160 Amps with breaking capacity 36 KA, complete all as specified and directed. |
| 13 | S&F in repairs MCCB 4 pole415 volts microprocessor release type, 200 Amps with breaking capacity 36 KA, complete all as specified and directed. |
| 14 | S&F in repairs MCCB 4 pole415 volts microprocessor release type, 250 Amps with breaking capacity 36 KA, complete all as specified and directed. |
| 15 | S&F in repairs MCCB 4 pole415 volts microprocessor release type, 400 Amps with breaking capacity 50 KA, complete all as specified and directed. |
| 16 | S&F in repairs MS chequered plate of 6 mm thick confirming to FE-290 grade 165 including provision of lifting handle for each plate on existing cable ducts and manhole covers for semi under ground sumps including painting with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 17 | Supply, laying, jointing and testing XLPE insulated of cross sectional area 10 Sqmm 4 Core, PVC inner sheathed, armoured with galvanised steelstrip or wire, heavy duty, LT underground cable ISI marked with aluminium conductor 1100 volt grade laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking out existing old unserviceable cable, complete all as specified and directed.Note:- Earthwork, sand cushion, cable cover if required will be measured and paid separately under respective items of this Schedule. |
| 18 | All as per Ser item No 17.00 here in above but cross sectional area 16 Sqmm 4 core. |
| 19 | All as per Ser item No 17.00 here in above but cross sectional area 25 Sqmm 3.5 core. |
| 20 | All as per Ser item No 17.00 here in above but cross sectional area 95 Sqmm 3.5 core. |
| 21 | All as per Ser item No 17.00 here in above but cross sectional area 120 Sqmm 3.5 core. |
| 22 | M&L for cutting the existing bituminous / hard Standing road surfaces upto 100mm deep and 300mm wide and making good disturbed portion for laying of cable / GI pipe etc. and providing 100mm thick plain cement concrete, 1:2:4, type B-2 (using 20 mm graded crushed stone aggregate) for filling up the area of road cutting surfaces and making good the disturbed surface with existing surface, complete all as specified and directed . |
| 23 | Excavation in trenches, n. exc 1.5 m wide and n. exc 1.5m depth and getting out in for foundation of pole, stay, laying of cable and pipe in any type of soil etc all as specified and directed |
| 24 | Excavation in trenches, n. exc 1.5 m wide and exc 1.5m but n exc 3.0m depth and getting out in for foundation of pole, stay, laying of cable and pipe in any type of soil etc all as specified and directed |
| 25 | Removing excavated material to a distance n.exc 50 m & depositing where directedat a level n. exc 1.50 m above the starting point, complete as specified and directed. |
| 26 | Returing, filling in incl spreading, levelling, watering and well ramming in layers n exc 25cm thick after laying of the cables,jointing & testing complete all as specified and directed. |
| 27 | M&L for laying of bricks well burnt sub class B (old size) laid flat for cable protection width equal to the length of bricks, complete all as specified and directed |
| 28 | M&L for sand cushioning in trenches spreading and consolidation 8 cm thick before laying the cable and 15 cm of the sand after laying the cable but will be measured 18 cm after punning etc., complete all as specified and directed. |
| 29 | S&F in repairs 80mm dia GI tubing, light grade, with all fittings fixed on walls / poles for protection of cable including clamp 02 Nos of size 25x4 mm, nut bolts, washers etc, complete all as specified and directed. |
| 30 | S&F in repairs 100mm dia GI tubing, light grade, with all fittings fixed on walls / poles for protection of cable including clamp 02 Nos of size 25x4 mm, nut bolts, washers etc, complete all as specified and directed. |
| 31 | M & L for painting of steel tubular 4 pole structure of any capacity complete lenght, by applying one coat of white cement based paint after scraping / brushing and cleaning the Algae on pole and cross arms and a coat of white synthetic enamel painting to pole upto 1.5m from groundlevel shall be painted by alternate layer of black and yellow enamel paint (30 cms apart) and two coat of aluminium painting shall be done on cross arm and bracing, nut, bolts and washers etc after preperation of surfaces, complete all as specified and directed .Note - One 4 pole structure measured as one job inclusive of HT poles and cross arms complete. |
| 32 | M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 m below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32 x 6 mm (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire meshincluding necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit , internal surface of concrete shall be given 10mm thick plaster in CM 1:4 and 40 mm thick precast RCC cover 1 : 2 : 4 ,type B-1( using 20 mm graded crushed stone aggregare ) reinforced with8 mm dia TMT bars @ 75 mm c/c both ways with 12mm dia round bar as in handle including taking down of existing earthing, completeall as specified and directed. |
| 33 | NOTE: (i) The cost of earth lead and its protection pipe upto and including 7.5 m only from the top of earth electrode are deemed to be included under this item and additional earth lead , if any, required at site shall bemeasured and paid for separately under appropriate item of Schedule `A’/BOQ.(ii) Any joint in earth lead from earth electrode to test point shall not be allowed/permitted. |
| 34 | Supply, installation, testing & commissioning, LT panel cubical type of size 0.9 x 0.6 x 0.6 Metre,CPRI Approved, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, outdoor type, factory fabricated, duly powder coated inside and out side, outer cover made out of 3.15 mm thick CRCA sheet, internal cover and partition made out of 2mm thick CRCA sheet with angle iron 40mm x 40mm x 6mm and 0.5m long covered from all side with front and back openable, dust, vermin and weather proof including suitable rating Copper bus bar for 3 phase 4 wire system, wiring with suitable size coppercable and embedded in brickwork with nuts, bolts and washer etc., complete comprising of following including taking out the old unserviceable panel, complete all as specified and directed. |
| 35 | Incoming:- (a) MCCB 4 pole,125 Amp, 50 KA, 415 volts AC with adjustable thermal and adjustable magnetic setting- 01 No. (b) Aluminium bus bar 200 Amp TPN - 04 Nos(c) Digital voltmeter 0-500 volts with selector switch -01 No(d) Digital Amp meter0-200 Amp with selector switch & CT - 01 No, (e) Indicator lamp LED type (R, Y, B) complete with Bakelite fuse fitting - 01 Set(f)Onload change over switch 160 Amps with suitable handle for operating-01 NoOutgoing:- (a) MCCB 4 pole, 63 Amp, 36 KA, 415 volts AC- 02 Nos.Note: LT panel board shall be mounted on brickwork in CM 1:4 not less than 60 cm above ground level and 30 cm below ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate. |
| 36 | Supply, installation, testing & commissioning, LT panel cubical type of size 0.9 x 0.6 x 0.6 Metre,CPRI Approved, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, outdoor type, factory fabricated, duly powder coated inside and out side, outer cover made out of 3.15 mm thick CRCA sheet, internal cover and partition made out of 2mm thick CRCA sheet with angle iron 40mm x 40mm x 6mm and 0.5m long covered from all side with front and back openable, dust, vermin and weather proof including suitable rating Copper bus bar for 3 phase 4 wire system, wiring with suitable size coppercable and embedded in brickwork with nuts, bolts and washer etc., complete comprising of following including taking out the old unserviceable panel, complete all as specified and directed. |
| 37 | Incoming:- (a) MCCB 4 pole,200 Amp, 50 KA, 415 volts AC with adjustable thermal and adjustable magnetic setting- 01 No. (b) Aluminium bus bar 200 Amp TPN - 04 Nos(c) Digital voltmeter 0-500 volts with selector switch -01 No(d) Digital Amp meter0-200 Amp with selector switch & CT - 01 No, (e) Indicator lamp LED type (R, Y, B) complete with Bakelite fuse fitting - 01 Set(f)Onload change over switch 160 Amps with suitable handle for operating-01 NoOutgoing:- (a) MCCB 4 pole, 63 Amp, 36 KA, 415 volts AC- 05 Nos.Note: LT panel board shall be mounted on brickwork in CM 1:4 not less than 60 cm above ground level and 30 cm below ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate. |
| 38 | S&F in replacement of LT feeder pillar box, outdoor type, factory made, weather and vermin proof made out from 3.15mm sheet supported with legs 45cm long made of angle iron 50x50x5mm of size 1.2m x 1m x 1m with 3 Nos 0.8m Aluminium bus bar of size 40x10mm or 400 Amps for 1100 Volt post Insulator 08 Nos duly drilled hole for LT Cable connection including front and rear side openable with locking arrangment suitable for 1100 V LT and provision for incoming and outgoing LT cable connection including painting with two coats of smoke gray synthetic enamels paint over a coat of red oxide primer, complete all as specified and directed.Note:- Feeder piller box shall be mounted on brick plate form built in CM 1:4 not less then 60cm above ground level with suitable PCC foundation rendering 15 mm in CM 1:6, applying two coats and cement base paints and supported on 04 Nos angle iron with concrete base. |
| 39 | Supply, installation, commissioning and testing busbar panel of totally enclosed, outdoor type, factory fabricated, weldless cubical Kiosk in modular bolted construction type dust and vermin proof equal angle iron mounted type (IP-65 degree of protection) made out of 3 mm thick CRCA sheet, all sheet metal parts separately chemically treated with 7 tank treatment process, the panel having both side opening door with locking arrangement bus bar door lock should be easy openable, brass knob type with comfirtabley gripped PVC head nut, all doors fixed with steel higes (door should be open from left hand side to right hand side) duly painted with two coats of synthetic enamel paint powder coated, mounted on iron angle frame made out of 50 X 50X 6mm frame with 4 Nos of legs size not less than 50cms (bottom portion of the panel wrt normal ground level) fixed with nut bolts of suitable size, grouted by using foundation PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) totally tested as per IEC 61439-I,including taking down old unsv bus bar panel and comprising of following:- |
| 40 | Busbar Details : (a) Rated voltage :- 11 KV, 50 Hz.(b) Material - Copper.(c) Busbar strips arrangemets - Horizontally fixed.(d) Buabar insulation Materail - Bare.(e)Busbar position - Edge mounted Bars.(f) Busbar Size :-Busbar Width - 100 mm(g) Busbar thickness - 10 mm(h) Number of Busbar per Phase - 01(j) Busbar Length per Phase - 500mm, duly drilled holes for connections and mounted on epoxy resin cast HT support insulators for busbar support.Enclosure Details : (a) Installation of HT Busbar- Outdoor Type (Angle Iron Legs mounted).(b) HT Busbar Dimention (L x W x H) - 1200 x 900 x 750mm |
| 41 | Deduction to be made from BOQ for Schedule \"A\" Part-II (Credit Schedule from dismantling / taking down items) worth Rs 95,815.00 during AOC. (Note :- Tenderers shall not quote for this Schedule) |