| 1 | Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit with modular type switch, phenolic laminated sheet suitable M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group A |
| 2 | Wiring for Twin Control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit with modular type switch, phenolic laminated sheet suitable M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 3 | Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 4 | 2 X 1.5 sq. mm + 1 x 1.5 sq. mm earth wire |
| 5 | 2 X 2.5 sq. mm + 1 x 2.5 sq. mm earth wire |
| 6 | 2 X 4 sq. mm + 1 x 4 sq. mm earth wire |
| 7 | 2 X 6 sq. mm + 1 x 6 sq. mm earth wire |
| 8 | 4 X 6 sq. mm + 2 x 6 sq. mm earth wire |
| 9 | Supply and Fixing following modular switch/socket on the existing modular plate & switch box including connection but excluding modular plate etc.as required |
| 10 | 5/6 A switch |
| 11 | 3 Pin 5/6 A socket outlet |
| 12 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 13 | 4 way (4 + 12), Double door |
| 14 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 15 | Single Pole |
| 16 | Triple Pole & neutral |
| 17 | Triple Pole |
| 18 | Supplying and fixing following ways surface/recess mounting, vertical type, 415V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common netural link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note Vertical type MCB TPNDB is normally used where 3 phase outlets are required) |
| 19 | 4 way (4 + 12), Double door |
| 20 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel, making connection, etc as required |
| 21 | 100 Amp. 4 pole MCCB |
| 22 | 200 Amp. 4 pole MCCB |
| 23 | Supplying and fixing following rating, four pole, 415V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 24 | 63 Amp. |
| 25 | S/B Earthing with G.I. plate 600mm X 600mm X 6mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 26 | S/L of 25mm X 5mm G.I. strip at 0.50 Mtr below ground as strip earth electrode |
| 27 | Supply and fixing suitable size GI box with modular plate and cover in front on surface on in recess, including providing and fixing 6 pin 5/6 & 15/16A modular socket outlet and 15/16 A modular switch, connections etc. as required |
| 28 | Supply, Installation, Testing and commissioning of 1200 mm sweep BEE 5 star Rated, Ceiling fan with Brush Less Direct current (BLDC) Motor, Class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS:374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. Complete as required. |
| 29 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheated/XLPE aluminium conductor cable of 1.1 KV grade as required |
| 30 | 400 sq. mm 3.5 core |
| 31 | 150 sq. mm 3.5 core |
| 32 | 50 sq. mm 3.5 core |
| 33 | 25 sq. mm 3.5 core |
| 34 | Errection and Testing of 300mm exhaust Fan |
| 35 | Supply & fixing call bell/buzzer suitable for single phase, 230 V, complete as required |
| 36 | Providing and Fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.80mm dia |
| 37 | Supply and fixing of 1x22 W LED Metal body batten fitting complete lumens suitable mounting for on both surface & suspended with 5 year warrantee complete in all respect. CAT-AAA 2620 system lumens, 110Im/W, PF>0.95, THD<10% CRI>80, with 5 Year warantee. |
| 38 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 65 and above Protection complete in all respect. 6600-7920 system lumens, High power LED with lenses, >110 lm/W, PF>0.95, [potted driver set Not Circultory), Pse to Phase protection at 440V & >300V auto cut and re-start feature with 5 years warrantee |
| 39 | Supply and fixing of IP20, mid power SMD type LED light 2\"x2\" 36 watt to 46 watt, indoor recess mounting LED square fitting for armstrong Ceiling powder coated CRCA housing body, High purity/transmisivity UV stablized Non yellowwish diffuser/reflector for uniform light distribution, deteachable driver set open and short circuit protection, suitable for 24 Hr continous operation complete in all respect CAT-AA 3960-5060 system lumens, with fully covered diffuser type, >120 Lm/W, PF>0.95, THD<10% at full load, CRI>80, > with 3 Year warantee. |
| 40 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 41 | 400 sq. mm 3.5 core |
| 42 | 150 sq. mm 3.5 core |
| 43 | 50 sq. mm 3.5 core |
| 44 | 25 sq. mm 3.5 core |
| 45 | S/F of Water light oblong 10 watt LED bulkhead luminaire having pressure die cast housing with driver set confirming to IP65 and above protection, IK08, high purity/transmisivity UV Stablized Non yellowish diffuser/for uniform light distribution, detachable driver set, open and short circuit protection, suitable for 24 Hrs. continous operation complete in all respect |
| 46 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB\"s (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. |
| 47 | Incoming 400 Amp. MCCB - 1 Nos.Outgoing 200 Amp. MCCB - 1 No100 Amp. MCCB - 1 No. &63 Amp MCCB - 2 Nos. |
| 48 | S/F of 7 Watt LED Bulb |
| 49 | Supply of Fresh Air Fan 300mm Sweep metalic |
| 50 | Shock Treatmnent Chart |
| 51 | Supply & fixing of CO2 type fire extinguisher, 4.5 kg. capacity (ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 52 | Supply & fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 53 | Fire Bucket |
| 54 | S/F of Computer Board with 3 Nos. 5 Amp. Switch & socket and 15 Amp. Switch & socket complete in all respect |
| 55 | Modular type MCB protected socket with sheet steel enclouser for A.C. unit |
| 56 | S/F of 100 Amp. 4 pole changeover switch |
| 57 | S/F of Fancy wall bracket 6 to 8 Watt Please Enable Macros to View BoQ information |