| 1 | BOQ IOTEM NO. 01 TO 08 COMMON FOR BOTH JOBS Demolition of plain Concrete of any description and in any position not otherwise specifically provided for complete all as specified & directed. |
| 2 | Excavation in post holes ( or similar holes) each n.exc 0.50cum and getting out in soft/loose soil, returning filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25cm, watering and removing surplus soil to a distance n.exc 50mtr and making good surface etc concrete etc complete all as specified and as directed. |
| 3 | Returning filling in cluding spreading levelling watering and well ramming in layers not exc 25cm in hard dense soil. |
| 4 | Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed |
| 5 | M&L Cement concrete 1:4:8 (Type D2) in foundations, filling and mass concrete all as specified and as directed. |
| 6 | M&L for PCC 1:3:6 type C-2 (40mm graded stone aggregate) as foundations,fillin and mass concrete etc complete all as specified and as directed. |
| 7 | M&L for preparation of new surfaces of steel of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed. |
| 8 | M&L for Mild steel screw bolts(machine made) withhexagonal or squareheads at one end andscrewed the other, orscrewed both ends, eachscrewed end to be fittedwith washers and onehexagonal or squarenut,exc 30cm lbut n exc 60 cm long |
| 9 | ITEM NO. 09 TO 59 FOR JOB NO.LSA/DWP/33/LBW/2025-26Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete complete all as specified & directed. |
| 10 | Demolition of reinforced cement Concrete of any description andin anypositionnot otherwisespecifically provided for complete all as specified & directed. |
| 11 | Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc,complete all as specified & directed. |
| 12 | M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6)complete all as specified & directed. |
| 13 | Excavation in trenches not exc 1.5 mtrs depth and not exc 1.5 mtrs wide for foundation, man hole etc, not exc 10 sqm on plan in hard and dense soil etccomplete all as specified & directed. |
| 14 | M&L for PCC 1:2:4 ,type b-1 using (20mm graded stone aggregate) as bands of parapatetccomplete all as specified & directed. |
| 15 | M&L TMT 10mm dia and over cut to length, bent to shape required incl. cranking, bending and incl. mild steel wire (annealed) not less than 0.9mm dia or securing with clips. |
| 16 | M&L TMT 6mm to 8mm dia cut to length, bent to shape required incl. cranking, bending and incl. mild steel wire (annealed) not less than 0.9mm dia or securing with clips. |
| 17 | M&L for Formwork to sides of footings of concrete foundation with fair finished surfaces of concrete complete all as specified and directed. |
| 18 | M&L for Formwork to sides of columns with rough finished surfaces of concrete complete all as specified and directed. |
| 19 | M&L for Formwork to sides and soffits of lintels & beams including supports overhangs etc with rough finished surfaces of concrete. |
| 20 | M&L for Reinforced cement concrete (nominal mix) type B1 1:2:4 (20mm graded stone aggregate) Foundations, including rafts, footings, foundation beams,plinth beams; bases forcolumns, etc.; basement slabs,under-reamed piles and massconcreteand the likecomplete all as specified and as directed. |
| 21 | M&L for Reinforced cement concrete (nominal mix) type B1 1:2:4 (20mm graded stone aggregate) columns, piers, posts and struts complete all as specified and as directed. |
| 22 | M&L for Reinforced cement concrete (nominal mix) type B1 1:2:4 (20mm graded stone aggregate) Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. |
| 23 | M & L rendering 15 mm thickin CM1:6 on fair faces of brick work or concrete surfaces of wall surfacesfinished even and smooth without using extra cement complete all as specified and as directed. |
| 24 | M&L 15mm thick rendering in (CM) 1:4on fair surfaces of brick walls or concrete surfaces of wall surfacesfinished even and smooth without using extra cement complete all as specified and as directed. |
| 25 | M & L complete removal of existing treatment by scrapping ,rubbing down and washing by water , Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) over 2-3mm thick putty complete all as specified. |
| 26 | M & L preparation of new plastered surfaces of walls , Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) over 2-3mm thick putty complete all as specified. |
| 27 | M&L for Complete removal of exiting treatment and applying two coatsof oil bound distemper over one coat of wall care putty (Make : Birla/JK White) of wall incl preparation all as specified and directed. |
| 28 | M&L preparation of new plaster surfaces of wall and applying two coats of oil bound distemper over one coat of wall care puty 3mm thick on walls with alkali resistant primer all as specified. |
| 29 | Taking down chowkat or frame with shutters area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the shutters from the frame) including iron mongery and cutting holes for hold fasts & making good complete all as specified & directed. |
| 30 | Taking down chowkat or frame with shutters area not exc 1.5 Sqm each (without taking off the shutters from the frame) including irom mongrey andcutting holes for hold fasts & making good complete all as specified & directed. |
| 31 | S&F coloured Pre- painted galvalume aluminum zinc coating GI based corrugated steelsheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified all as per manufactures instruction. complete all as specified & directed. |
| 32 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding towall, fixed with self tapping screws as specified all as manufacturers instruction and complete all as specified & directed. |
| 33 | S&F aluminium powder coated frame/chowkatof aluminium door section of 80x44x1.60 to1.8 mm thick fixed with rawal plug and screw or wire expansion hold fasteners complete all as specified and as directed. make Jindal/Hindalco |
| 34 | Providing and fixing powder coated aluminium partly glazesd and partly paneled door shutter side hung type using 1.50mm thick standered door section having size of styles, toprails 83x44mm x 1.6 to 1.8mm thick where as bottom rails will be made up of 100x44mm Make: Jindal/Hindalico including necessary joining cleats glazing clips, rubber packing, anodized aluminium snap beading screws, powder coated aluminium fittings such as 100mm long 3 No. aluminium hinges B-21 ,type 01 No. aluminium tower bolt 200mm long and one no mortise lock 100mm size4 levers (vertical type) and 01 No 300mm size long aluminium sliding bolt and 02 No fancey type fiber glass 150mm dia circular handle shall be provided to each door and glazing of top panel shall be made of 5.50 thick sheet glass make - Modi/ Saint gobin and panelling shall be provided with 12mm thick exterior grade pre laiminated partical board with both side choice laminations,complete all as specified & directed. |
| 35 | S&F powder coated (min 50 micron) alumiumthree track sliding window with extructed profile of top bottom &side track for fixing 5.50mm thick tint glass fitted with glazing clip and EPDM rubber in two shutters and fixed SS wire mesh in one shutter and powder coated deco grill incl roller and handle complete all as specified and as directed. Note:-(a) Quoted rate incl 5.5mm thick tint glass, SS wire mesh, Deco Grill etc in this item.(b) Framed section 3 Track size=92x31.75x1.5mm(c)Shutter section size=40x18x1.55mm |
| 36 | S&F aluminium body door closer hydraulically regulated, designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg. and fixed. complete all as specified & directed. |
| 37 | S&F for Collapsible steel gates, top hung,consisting of channel pickets, pivotedflat bars, top and bottom runners, brasshandles etc., as specified, erected inposition and securing runners withholdfasts and brackets, complete all as specified and as directed |
| 38 | S&F mild steel section such asRoof trusses (framed), trussed,purlins, crane antries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.conforming to IS 1161-1979 Fe-290(Gde E-165) etc complete all as specified and as directed. |
| 39 | Fabrication, erection & fixing only steel work in tubular trussesincluding special shapedwasher etc. complete usingERW or induction butt weldedtubes conforming to I. S.1161 1979 grade St.-240Note :- Reuse the truss members at the site. |
| 40 | S&F mild steel Plates (plain or chequered)channels,squarecutor notched(ordinaryand countersunk)forming holes, without anyattachment conforming to IS 1161-1979 Fe-290(Gde E-165) etc complete all as specified and as directed. |
| 41 | M&L for Framed work as in doors orgates of angle or other sectionwith gusset plates, rails,braces, etc., complete, drilled forfixing of steel sheeting or othercovering. Doors, etc. to beprepared for hanging or slidingwith and including either hooksand hinges or steel hangingdoor fittings (exclusive of steelsheeting or other covering,running rails and guides) andhanging; also fastening andfixing complete |
| 42 | S&F of framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 etc. complete all as specified & directed. |
| 43 | S&F false ceiling with 4mm thick E-board Everest make white prepainted set embosed rainforced designer ceiling board of approved texure fixed with GI imposed grid frame work of size not more than 600x600mm having 24mm wide T-section runner made of 0.33mm GI sheet and angle made of 0.45mm, GI sheet suspected with 4mm dia GI wire including two coat of plastic emulsion paint over one coat primer complete all as specified.Note.All exposed surface of grid work shall be powder coated white. |
| 44 | S&F for vitrifield ceramic tiles double charged dark/light shade 10mm thick (Square/rectangular) polished area of each tile not exc 0.36 Sqm in floor etc laid over 15mm thick screed bed in CM (1:4) set and jointed in neat cement slurry and pointed in white/coloured cement to match including dismantling of floor tiles complete all as specified and directed. |
| 45 | S&F for vitrifield ceramic tiles double charged dark/light shade 10mm thick (Square/rectangular) polished area of each tile not exc 0.36 Sqm as in skirting etc laid over 10mm thick plaster in CM (1:4) set and jointed in neat cement slurry and pointed in white/coloured cement to match including dismantling of floor tiles complete all as specified and directed. |
| 46 | Dismantling plain fabric sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings |
| 47 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed |
| 48 | S&F coloured prepainted GALVALUME aluminium zinc coating GI based corrugated steel sheet 0.50mm thick having tensile strength of 550 Mpa as in roof covering cladding to wall fixed with self taping screws including necessary washers etc all as per manufacture instruction complete all as specified and as directed. |
| 49 | M&L for 20mm thick granite (of any type) work (table rubbed and polished) on walls, steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of graniteetc including roundening, machine polishing to edge to give high gloss finish etc. complete all as specified & directed. |
| 50 | S&F of stainless steel letters or figures \"INDIAN AIR FORCE ,MISSION, UNITY, INTEGRITY\" (Block.Roman, Italic or Indian) of size 250mm high x 300 mm width or actual required on siteetc complete all as specified & directed. |
| 51 | S&F of stainless steel logo of \"INDIAN AIR FORCE\"of size0.60m dia circular plate marked with letters or figures as per sampleon site complete all as specified & directed. |
| 52 | Removing existing roof treatment and preparing surfaces to the entire satisfaction of GE/Engr in Charge , cleaning of all foreign material such as gras , root, dust and roughning of brick/cocrete surfaces by wire brushes and washing down to remove dust, flushing at junctions of parapet walls complete all as specified. |
| 53 | M&L for cement concrete type B1 1:2:4 (12.5 mm graded aggregate) on roof slab all as specified. |
| 54 | Rendering 15 mm thick on fair faces ofconcrete surfaces of roof in cement mortar 1:4, mixed with liquid water proofing compound finished even and smooth without using extra cement . (Liquid water proofing compound to be measured paid separately) complete all as specified and directed. |
| 55 | Supply only Liquid water proofing compound complete all as spesified and directed. |
| 56 | M&L for supplying and appying high performance hybrid polyurea elastomericwaterproofing coating cold applied of spray/brush applied , smartcare Ulton liquid membrane at 1.5 Kg/Sqm with an elongation of 600% and tensile strength of 12.6 N/mm2 as per ASTM D2370, crack bridging ability of 3.5mm as per ASTM C1305, shore a hardness of min. 75 as per ASTM D 2240. The system includes final base preparation, epoxy primer application and applying smartcare Ultron or approved equivalent in two coats at a coverage of 1 Kg/Sqm, etc. complete as per manufacturer specification, including removal of the old waterproofing system and repairing and cleaning of the surface. |
| 57 | M&L for cheqered rubber mouled cement concrete tiles 30cm x 30cmx 25mm thick with grey cement and pigment, set,jointed and laid over 20mm thich screed bed in CM 1:6, jointed and pointed in neat cement slurry in floors, and cut and polishedincluding dismantling of floor tiles complete all as specified and directed. complete all as specified and directed. |
| 58 | S&F of Natural turbo ventilators 600mm size width complete aluminium not exc 1200mm width with mild steel powder coated brackets support on fiber glass fixed in position more than 12.5 kg complete all as specified and as directed. |
| 59 | S&F of hallow strip PVC Wall Linning consisting of 5mm thick any color/desigened PVC sheet inclusive of nails and fixing at site on wall and PVCL-beadingat top of wall lining,corner of wall,opening eadge of door & windows matching with panel as per specifications and drawing complete all as specified and as directed. |
| 60 | ITEM NO. 60 TO 71 FOR JOB NO.LSA/DWP/44/SRW/2025-26 Dismantling posts or struts (steel or RCC) any section embedded in concrete, including taking out embeded portion and making good disturbed ground and preparing post holes for providing new posts in any type of soil complete all as specified and directed. |
| 61 | Dismantling posts or struts (Steel or RCC) any section embedded in natural ground, including taking out embeded portion and making good distrubed ground and preparing post holes for providing new posts in any type of soil complete all as specified and directed. |
| 62 | Taking down carefully old galvanised stranded steel barbed wire from old RCC posts and removing from site all as directed. |
| 63 | M&L for MS work for fencing post an struts made from angle iron and flat iron in any section including cutting tops to shape, drilling holes and notching for fixing of wires etc confirming to Fe-290 or Fee-330, complete all as specified and directed. |
| 64 | Dismantling fencing wire mesh, anytype, complete all as specified and directed. |
| 65 | Supply only chain link MS zink coating 60 gms as per IS 4826 fencing of any mesh size and 3mm dia or wire complete all as specified. Note : This items shall be measured and paid as per actual weight or standard weight as per SSR which ever is less complete all as specified and directed. |
| 66 | Fixing only chain link fencing including line wire, any mesh size and any type of standards rails straining bolt etc including provision of binding wire complete all as specified and directed. |
| 67 | Refixing only chain link fencing including line wire, any mesh size and any type of standards rails straining bolt etc including provision of binding wire complete all as specified and directed. |
| 68 | M&L 5 to 10mm dia mild steel screw bolts (Machine made ) with hexagonal or square head at one end and screwed the other or screwed both ends screwed and to be bolted with washers and one hexagonal or square not exc 50mm long and dia of shank 5 to 10mm including fixed with welding to angle complete all as specified and directed. |
| 69 | S&F in repair Galvanised. 2 strand, steel barbedwire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed (each line wire to be measured) |
| 70 | M&L for preparation of new steel & iron surfaces n. exc 10cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide pimer complete all as specified and directed. |
| 71 | S&F for Concertina Coil Punched type 600mm dia , Central core wire - madefrom high tensile , spring steel - high carbon wire conforming to IS 4454/Part-/Garde-Sm duly hot dipped galvanized with diameter staring from 2.50mm, UTS 1670N/mm2, heavyzinc coating with minimum 230gms per srm. Razor punched tape - galvanized steel strip As per IS 513/D.D Grade/2004, with concertina clips heavy duty J clipsto be used for making concertina coilswhich is made from steel Fe410 complete all as specified and directed. |
| 72 | ELECTRIC ITEMSFOR JOB NO.LSA/DWP/33/LBW/2025-26 M&L for point re-wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm and earth continuity conductor with 1.5 sqmm colour codedrawn into and including concealed rigid non metallic PVC conduit medium grade not less than 25 mm diaISI marked ivory colour with all conduit fittings / fixing accessories and sunken modular GI metal boxes 1mm thick and modular cover plate with frame of approved colour for mounting modular switches, sockets etc as required for light/fan/bell wiring complete. |
| 73 | All as per Item No 72 hereinbefore but forOne 5 A socket outlet on independent Board all as specified . |
| 74 | All as per Item No 72 hereinbefore but forOne 5 A socket outlet onsameBoard all as specified. |
| 75 | All as per Item No 72hereinbefore but point re-wiring complete with 2.5 sqmm for 3 pin 5/15 A socket outlet on independent board including 2.5 sqmmFRLS grade PVC insulated unsheathed multi stranded copper conductor cable for earth continuity conductor all as specified. |
| 76 | Supply and fix in renewal of Modular switch one way 6A 230V AC 50 HZ SP one module all as specified. |
| 77 | Supply and fix in renewal of Modular switch one way 16A 230V AC 50 HZ SP one module all as specified. |
| 78 | Supply and fix in renewal of Modular socket 2/3 pin combined 6A 230V AC 50 HZ SP two module all as specified. |
| 79 | Supply and fix in renewal of Modular socket 6A/16A2/3 pin combined 230V AC 50 HZ SP two module all as specified. |
| 80 | S&F in renewal of modularbell push single pole 1 module6 Amp, 240 volt all as specified. |
| 81 | S&fin renewal of call bell , ding dong /musicalAC single phase 230 volts all as specified. |
| 82 | Supply and fix in renewal ofMCB DB SPN 8 way 230 volts, double door type with minimum capacity of 200 Amps rated bus bar including necessary dummy plate and necessary civil works all as specified. |
| 83 | Supply and fix in renewal of MCB SP 230V, 20-32 Ampscapacity all as specified. |
| 84 | Supply and fix in renewal of MCBSPN 230V, 32-63Ampscapacity all as specified. |
| 85 | S&F in renewal of Ceiling rose PVC polycarbonate all as specified. |
| 86 | Supply and fixingin renewal of wall/surface mounted integrated batten LED light luminaire of 4ft length with a system wattage of 20-22W with a nominal system lumen output of 2000-2200 lumens and a minimum system efficacy of 100Lm/W. CCT shall be 6500K and CRI ≥ 80. Housing shall be extruded aluminimum without powder coating & with IP20 protection, The luminaire shall meet IP20 rating with surge protection of 2.5KVA, THD ≤10% and PF ≥ 0.95, complete all as specifid. |
| 87 | Cutting chases in concrete wall/stone for laying PVC conduit and making good to facings where required and pointing in cement mortar 1:3, and making good, cutting not exc 20 cm girth and matching wall color incl two coats of wall colour for matching with the existing walls all as specified. |
| 88 | Material and Labour for Submain wiring with 2 runs of FRLSgradePVC copper conductor cable 4 sqmm, multistranded along with FRLS grade PVC insulated copper earth continuity conductor 4 Sqmm drawn through & includingPVC Conduit pipe 20 mm dia with all fittings complete(2x4sqmm+1x4sqmmearthwire) |
| 89 | Supply and laying XLPE Insulated armoured electric heavy power cable with aluminium stranded conductor ,1100 volts grade, cross sectional area 16 sqmm x two core complete all as specified |
| 90 | M &L for Excavation in trenches not exc 1.5 m wide and not exc 1.5m deep for laying of pipe, cable etc and getting out in soft/loose complete all as specified . |
| 91 | M&L for Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified . |
| 92 | M &L for Removing surplus excavated material to a distance not exc 50 meter and depositing where directed at level not exc 1.5m above the starting pointcomplete all as specified. |
| 93 | S&L DWC HDPE Pipe along with all aceessories like socket , bend,couplersetc ISI mark as per IS: 16205 (PART-24) including cutting,jointing,laid in trenches,wall , floor,etc as required 63 mm outer dia and 50 mm inner dia complete all as specified |
| 94 | Material and labour Earthing complete with galvanized steelearth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground(earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized earth wire of size 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 connected to earth testing point including necessary excavation, earth work, PCC pit ,RCC cover 1:2:4 B1 with 8 mm dia MS rounds 1.5 kgs, funnel ,watering pipe etc. all specified and directed including testing on completion all as specified. |
| 95 | S&F ceiling fan 1200 mm sweep BEE star rated 5 with brush less direct current(BLDC) motor ,class insulation B three no blade up to 90 cm long down rod , canopies ,shackle kit , safety rope,copper winding , PF not less than .9, service value (CM/M/W) minimum 6.00,air delivery minimum 210 cum/min,350 RPM(Tolerence as per IS: 374-2019),THD less than 10%, remote unit for speed control and all remaining accessories including safety pin,nut bolts,washers,temperature rise 75 degree C (max),insulation resistance more than 2 mega ohm suitable for 230 volts ,50 hzs includingremote control. |
| 96 | Supply and fixing LED building securitylight of 36W Led Street Light made up of pressure die cast aluminium housing with Polycarbonate cover and unique road optics for better uniformity. The luminaireshall be with higher ingress protection IP66 and impact resistance of IK07. Operating voltage range: 140-270V/50Hz, Lumen efficacy of LED >120Lm/W, CRI≥70, CCT-5700K, & SDCM<5. Powered by built-in potted LED driver gives constant light over wide voltage range. Shall have High Voltage cut-off@325V & safety from 440V (P2P) for 8 hours. Surge protection 4 kV, Power factor ≥0.95, THD ≤10 complete including 25x3 mm flat iron with bracket of GI pipe light grade 25 mm dia and length not less than 1.2 mtr end of GI pipe suitable for street light fittingcomplete all as specified. |
| 97 | Supply and fixing in replacement of Solar integral AIO streetlight withAluminium housing, reliable & robust construction with IP65 & IK08 protection. The luminare Lithium /LifePo4Battery capacity min [email protected] or 20w4.5vpvpanel power CRI >=70, System Efficacy >165lm/W, & Minimum Lumen 4000 system wattage should not be more than 25W ± 2%, if wattages increases then the size of battery & panel shall also be increased in similar percentage to maintain equal autonomy of the system. Weight not more than 2.32 kg. The fixture should have in microwave motion sensor &sensor dealy time 18 secondsLife class of LED 50000hrs@ .complete all as specified. |
| 98 | Supply and fixing LED building Floodlight of 70 W Led Street Light made up of pressure die cast aluminium housing with Polycarbonate cover and unique road optics for better uniformity. The luminaireshall be with higher ingress protection IP66 and impact resistance of IK07. Operating voltage range: 140-270V/50Hz, Lumen efficacy of LED >120Lm/W, CRI≥70, CCT-5700K, & SDCM<5. Powered by built-in potted LED driver gives constant light over wide voltage range. Shall have High Voltage cut-off@325V & safety from 440V (P2P) for 8 hours. Surge protection 4 kV, Power factor ≥0.95, THD ≤10 complete including 25x3 mm flat iron with bracket of GI pipe light grade 25 mm dia and length not less than 1.2 mtr end of GI pipe suitable for street light fittingcomplete all as specified. |