| 1 | Supply of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95 |
| 2 | Supply of XLPE insulated PVC sheathed Al. Conductor Un-Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm |
| 3 | Supply of 4 sq. mm ISI marked, FRLS PVC insulated, Single core copper conductor cable |
| 4 | Supply of 2.5 sq. mm ISI marked, FRLS PVC insulated, Single core copper conductor cable |
| 5 | Supply of 1.5 sq. mm ISI marked, FRLS PVC insulated, Single core copper conductor cable |
| 6 | SITC of 1 H.P. single phase mono self priming pumping set suitable for a head of 12 to 30 mtr. Discharge 3300to 400 LPH and suction / delivery 25X25 mm suitable to work 180 to 230 volt, A.C. supply . |
| 7 | Supply of 12\" (300mm) sweep 1400 rpm exhaust fan fan heavy duty complete with shutters, blades etc as reqd. |
| 8 | Supply of following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator) (a) 6 way , Double door |
| 9 | SITC of 30W LED Flood Light luminaire fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =30 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66 |
| 10 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface I recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 11 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group C |
| 12 | Supply of PVC batten /angle holder. |
| 13 | Supply of 6 pin 15/16 & 5/6 Amp socket outlet piano type ISI marked |
| 14 | Supply of 15/16 Amp one way switch piano type ISI marked |
| 15 | Supply of 3 pin 5/6 Amp socket outlet piano type ISI marked. |
| 16 | Supply of 5/6 Amp one way switch piano type ISI marked |
| 17 | Supply of 40 Amp, 2 pole isolator. |
| 18 | Supply of 6- 32 amps rating, SP MCB, Ccurve, 10 KA breakina capacity. |
| 19 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 20 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 21 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*4 sqmm |
| 22 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-3C*6 sqmm |
| 23 | Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2c*10 sqmm |
| 24 | P/FHot press sheet mouldedcompound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof polebox of innerdimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nosof 6 to 32 amp single pole MCB & 63 Amp. Doublepole isolator (MCB/Isolator excluded) withneutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plateofsuitable size with danger monogram property printed on the coveretc asreqd. asreqd. |
| 25 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 26 | supply and fixing of 4.5 Kg CO2 fire extinguisher (wall mounting type) as per BIS specifications (conforming to IS: 2878) |
| 27 | Refilling & testing of ABC type fire extinguisher stored pressure dry powder Mono Ammonium by Phosphate Silicon Capacity 6 Kg |
| 28 | Development of tube well with suitable capacity of air compressor i/c lowering of the necessary induction pipe or linei/c cost of fuel, hire charges of compressor etc as reqd. The development shall be considered complete when Gravel stop sinking, Discharge ceased to improve and the sand contents are not more than 10 PPM after 20 minutes of starting the pump complete as reqd. |
| 29 | Comprehensive AMC (Annual Maintenance Contract) for repair and maintenance of Tube Wells Installed at various Municipal Works for depth upto 50 metres for cost of one Tubewells with submersible p/set etc of upto 1/1.5 HP |
| 30 | Deputing following staff for attending Electrical complaints for various CTC,PTB,SI Offices, sanitary staffs rooms for 2025-26 in ward 201,204 to215(13no.s of ward) under shahdra south zone. for one year(a) Wireman -1 nos. in 1 shift(b) E/Beldar -1 nos. in 1 shift |
| 31 | Repair/Rewinding of existing 1HP mono block pump set including replacement of parts like gun metal bush/ bearing condenser, impeller etc to make the pump functional as required. |
| 32 | Supply of 9 Watt LED retrofit lamp suitable for B22 holder |