| 1 | Desitliting of covered nallah/ covered drain (which will include continuous covering for 5 mtr. & above length at a stretch) including removing of stone patties, Ferro cement drain covers, dismantling of existing C.C. flooring etc. & re-placing the same (without mortar & C.C. etc.) after deslilting of nallah, spacing of opening should not be more than 5 mtr. or as per direction of engineer in charge with all lead & lift complete in all respect. |
| 2 | Dismantling of existing structures like culverts, bridges, retaining walls, CC road and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 50 metres as directed by Engineer.Cement Concrete Grade M-15 and above and PCC blocks |
| 3 | 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 ( 1cement : 5 coarse sand) with joints finished flush.Red sand stone |
| 4 | Providing and laying un-reinforced, plain cement concrete mix with Concrete Mixer & vibrator pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed as per approved mix design, laid, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints etc including all material, labour, machinery, lighting, guarding and maintenance of diversion.PCC M-20 |
| 5 | Random rubble masonry with hard stone in foundation and plinth :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 6 | Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 20 mm cement plaster of mix :1:6 (1 cement : 6 fine/ coarse sand) |
| 7 | Providing and fixing of reinforced Ferro-Cement drain covers designed for \"A\" class loading duly marked on cover with dequate steel reinforcement having thickness 75mm to 150mm anti corrosive bitumen painted M.S. plate , Rim and M.S. lifting hooks, Admixtures like plasticizer, bond improving compound, shrinkage, resistance compound, abrasion resistant complete as per approved design etc. |
| 8 | Standard Size 600x800mm for span 300 to 450mm |
| 9 | Standard Size 1000x800mm (100mm thick) for span 451 to 700mm |
| 10 | Standard Size 1500x600mm (125mm thick) for span 701 to 1200mm |
| 11 | Standard Size 2100x500mm for span 1201 to 1500mm |
| 12 | Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. Please Enable Macros to View BoQ information |