| 1 | Supply of 11000 lumens LED Flood Light fixture, powder coated pressure die cast aluminium body of thickness ≥ 1.5 mm with built in or separate driver as per the requirement with minimum lumen efficacy 110 lm/Watt output, Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50hz, internal surge protection >4 KV, Driver efficiency >85%,THD< 10%, P. F.≥0.95, IP-66,IK ≥07, CRI ≥70, life time of minimum 50000 Burning Hours, CCT 6000°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not be more than 110% of the specified rating etc. complete as required as per the specifications with Minimum 5 year OEM warranty. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. |
| 2 | Supply of 4180 Lumens Capacity 2x2 ft. surface/recess mounted LED fixture with powder coated CRCA housing thickness ≥0.5mm,minimum lumen efficacy 110 lm/Watt output, Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50Hz, internal surge protection of >2 KV , THD < 10% , P. F.≥0.95, IP20, CRI ≥80, UGR (Unified Glare Rating)≤ 19,life time of minimum 50000 Burning Hours with, CCT 6000°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not be more than 110% of the specified rating etc. complete as required as per the specificationswith Minimum 5 year OEM warranty. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. |
| 3 | Supply of 4180 Lumens Capacity LED surface mounted Batten light of Powder coated die cast/ Extruded aluminium body (Thickness ≥ 1.5 mm for PDC aluminium or ≥ 1.0 mm for Extruded aluminium ), minimum lumen efficacy 110 lm/Watt output, Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50Hz, internal surge protection of >2 KV , THD < 10% , P. F.≥0.95, IP20, CRI ≥80, UGR (Unified Glare Rating)≤ 19,life time of minimum 50000 Burning Hours with, CCT 6000°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not be more than 110% of the specified rating etc. complete as required as per the specificationswith Minimum 5 year OEM warranty. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. |
| 4 | Supplying and fixing of following ways surface/ recess mounting, Horizontal type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, prewired, with tin copper bus bar, common neutral link, earth bar, din bar for mounting MCBs of 63A FP, ELCB 100 mA, Four Pole Contactor , Astronomical timer, SP MCB as outgoing, suitable for 8 Module incomer as required. (Without MCB, ELCB, Contactor , Timer) |
| 5 | 4 way (8 +6+12), Double door |
| 6 | Supply of 3½ core × 35 Sq.mm size of 1.1 KV grade multicore aluminium conductor XLPE insulated and PVC sheathed armoured cable as per IS : 7098:1988 Part 1 with upto date amendments. |
| 7 | 3.5C X 35 Sq.mm |
| 8 | Supply of 3×2.5 Sq.mm size of 1.1 KV grade multicore aluminium conductor XLPE insulated and PVC sheathed armoured cable as per IS : 7098:1988 Part 1 with upto date amendments. |
| 9 | 3C X 2.5 Sq.mm |
| 10 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 11 | 3½ X 35 sq. mm (32mm) |
| 12 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size Upto 35 sq. mm etc as required (In the existing RCC / HUME /Stoneware/METAL PIPE). |
| 13 | Upto 35 Sq.mm |
| 14 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size Upto 35 sq. mm etc as required On cable tray / Raceways. |
| 15 | Upto 35 Sq.mm |
| 16 | Laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 17 | Upto 35 Sq.mm |
| 18 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering |
| 19 | Upto 35 Sq.mm |
| 20 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required.2 x 1.5 sqmm +1 x 1.5 Sq.mm |
| 21 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required.2 x 2.5 Sq.mm +1 x 2.5 Sq.mm |
| 22 | Installation, testing and commissioning of pre-wired, LED Light fitting/Flood light of all types, complete with all accessorieslike flexible hose, Junction Box, Connector etc. directly on ceiling/ wall/ metal, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 23 | Supplying and fixing of 63 Amps rating, Four pole, 415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 24 | Supplying and fixing 6A to 32 A rating, Single pole, 240 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 25 | Supply & installation of SMC box (similar to Hensel: KV6104 or equivalent)with arrangemet of fixing Four Pole MCB as required. |
| 26 | Supply & installation of Cable junction box IP 66/67 with PE Inlay (similar to Hensel: KF 0202 or equivalent)with necessary arrangement. |
| 27 | Supply of 1 row 12 modules with PE+ N terminals IP-65 Distribution boxes (Similar to Hensel -kV9112 M OR Legrand or equivalent) with DIN channel and metric knock outs for cable entry etc., as required. |
| 28 | Supply of 1 row 4 modules with PE+ N terminals IP-65 Distribution boxes (Similar to Hensel -KV7104 OR Legrand or equivalent) with DIN channel and metric knock outs for cable entry etc., as required. |
| 29 | Supply of 1 row 18 modules with PE+ N terminals IP-65 Distribution boxes (Similar to Hensel -KV9118 M OR Legrand or equivalent) with DIN channel and metric knock outs for cable entry etc., as required. |
| 30 | Supply and fixing of Twilight switches of 16 A (Similar to Legrand Cat No. 4126 23 or equivalent) for switching lighting circuit \"ON\" and \"OFF\"based on light conditions with IP65 protection etc., as required. |
| 31 | Supply and fixing of 2P, 30 mA, 24 A Earth leakage RCCB. |
| 32 | Supplying and fixing of 25 mm dia GI conduit along with accessories in surface /recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 33 | Supplying and making end termination with IP66 weather proof fully insulated Brass cable gland (Similar to Hensel: GSC20 or equivalent) and aluminium lugs of suitable size for 4c x 6 sq.mm./3c x 4 sq.mmsize of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 34 | Fixing of DB Boxes of following sizes on surface/recess complete with connecting, testing of commisioning as required. 1 row 4 modules/8 modules/12 modules/18 modules . |