| 1 | Taking downoflight fittings of any type size and modelcomplete all as specified and directed. |
| 2 | Taking downofbrackets of any type size and modelcomplete all as specified and directed. |
| 3 | Dismantlingsteel poles/struts of any size and removing off the sitecomplete all as specified and directed. |
| 4 | Taking down/out unserviceable UG Cables of any Cross Sectional Area and Connections including Bricks, GI Pipes, etc. of any descriptions, laid in Trenches and/or fixing with Walls/Poles including Segregating of Serviceable Materials viz Bricks, Cables, GI Pipes, etc. and keep in Safe custody for re-use, complete all as specified and as directed. |
| 5 | Material and labour for steel tubular poles complete with cast iron base palate, final taper plug bolts, nuts & screws as specified type 410 SP-22 8.50 meter long including painting all external exposed steel surfaces with two coats of aliminium paint over a coat of red oxide zinc chrome primer including marking pole numbers in a 15 cm dia yellow circle with number writting with blacksyenthic paint/ Stricker, includingpainting strips in alternate from top of coping upto 1.50m height, with three strips of black syenthaticpaint & two strips of Yellow/ Sky blue paint(as per existing pattern through out the circumference of pole), including and all internal surfaces and external surfaces upto the planting depth shall be painted with two coats of black bitumenous paint complete all as specified and as directed (Note:- Earth work, PCC work, shall be measured and paid separately.) |
| 6 | S&F Cable Junction Box 155X210X92 mm in size, made out of thermoplastic, having IP 66 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32 -02 No & M-25 -01 No) fixed on poles with Aluminium clamps of size 25x3mm, nuts, bolts, washers etc. including taking out of old unserviceable cable junction box complete all as specified and as directed. |
| 7 | Supply and passing through steel tubler pole/service connection, 1100 volts grade multicore,FR, round insulated copper conductor and sheathed flexible cable,multistranded, three coreofnominal cross sectonal area1.5 Sq mm,for connection of security light from junction box through pole /conduit with all terminals complete all as specified and as directed. |
| 8 | S&Fsingle arm bracket made of 40mm dia 1.0mtr long for security light ,with mounting MS clamp of flat iron size 25X5 mm of suitable length 02 pairs including nut bolts etc of suitable size and painting to MS clamp with two coats of aluminium paints over a coat of red oxide metal primer all as specified and directed by Engr In charge. |
| 9 | M&L for earthing complete with galvanised steel earth plate electrodesize 600 x 600 x 6 mm thick, burried directly in ground, (Earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below ground level connected to galvanised iron strip 32 x 6 mm as earthin lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion, surrounded from all sides by mixture of charcoal and common salt and electrode by means of steel and GI pipe Md grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specifiedNOTES 1. The unit rate includes for protection pipe and GI strip dia from top of earth plate upto 7.5 meter above ground level. NOTE:-1. The unit rate includes for protection GI pipe of 40 mm and watering pipeof 20 mm bore including excavation for earth pit in any type of soil/ disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to achieve desired result as the soil resistiviy is very high. 3.The cost ofGI strip of size 32 x 6 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately.4. All the joints in GI strip and connection with Earth Plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5. Cost ofwelding and nut bolts are deemed to be included in the unit rate. |
| 10 | Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole, laying of cables, pipes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soilNote : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding. |
| 11 | Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed. |
| 12 | Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed. |
| 13 | M&L Sand Cushioning (dry) in trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE : For the purpose of Payment, Punned thick-ness of Sand Cushioning only shall be Measured and Paid ) |
| 14 | Supply and laying well burnt Bricks , locally available best quality (sub class \"B\" bricks) laid in trenches perpandicular to U/G cable for cable protection complete all as specified. |
| 15 | Laying only in trenches or passing through pipe, XLPE insulated,heavy duty,galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 50 sqmm 3.5 core.Note : Cable will be issued under Sch B free for laying only |
| 16 | Laying only in trenches or passing through pipe, XLPE insulated,heavy duty,galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 10 sqmm 4 core.Note : Cable will be issued under Sch B free for laying only |
| 17 | S & F 40 mm High density polyethylene pipe (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed . |
| 18 | S&F Galvanised Iron Pipe 40mm Bore (dia) ‘Light Grade’ for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. |
| 19 | Labour only for Horizontal Boring for PassingProtection Pipe up to 80mm Bore (dia), under Road /Foot Path, not exc. 10.00 mtr in a Single Length, complete all as specified and as directed. Note : Pipe to be measured separately. |
| 20 | M&L for PCC (1:2:4)type B1 (using 20 mm gradedaggregate) as in coping for pole including form work and finishing the surfaces even and smooth,dismantling etc complete all as specified and as directed. |
| 21 | M&L for PCC 1:3:6 type C2 (using 40 mm gradedaggregate) as in foundation for pole etc complete all as specified and as directed. |
| 22 | Supply and fixing CRCA sheet steel duly phosphatized and powder coated with 7 tank process,wall/pole mounted/floor mounted,degree of protection IP 54,pre-wired,liberal terminal space,louvers provided on both sides for proper heat heat dissipation,manufactured by an ISO 9001 certified company,door locking by panel lock and provided for pad locking available,with auto/manual selection switch,astronomical programmable time switch( Operating voltage 220-240 Volt AC),three phase,MCB TPN 63 Amp(coil voltage 240 Volt AC) ,Power Contactor 65 Amp,TP,Astronomical timer,terminal blocks,maximun load 12KW, complete all as specified and as directed. |
| 23 | Fixing onlyLED street light fitting 100Watt 230 V AC outdoor type including necessary connection complete all as specified.Note : Street light will be issued under Sch B free for fixing only. |
| 24 | Fixing only LED Flood light fitting 200Watt 230 V AC outdoor typecomplete all as specified and directed.Note : Flood light will be issued under Sch B free for fixing only. |