| 1 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion from cement concrete and making good disturbed ground complete all as specifed and directed. |
| 2 | Excavation for post holes in any type of soil (or in similar hole ) each n.exc 0.50 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25cm including dismantling PCC including disposal of surplus n.exc 50m complete all as specifed and directed. |
| 3 | M&L forPCC 1:3:6 type C-2 (40mm graded aggts) in foundation filling and mass concrete complete all as specifed and directed. |
| 4 | M&L for posts and struts in fencing of angle, tee including cutting tops to shape as directed, drilling holes, notching for wire, Y angles wall for fencing, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or FE 310-0 complete all as specified and directed |
| 5 | Fixingchain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specifed and directed. |
| 6 | Supply only Chain link fencing with or without line wires,any type andmesh size and any type of standards and dia of wire ( as directed by Engineer-in-charge) fixed with rails, staining bolts etc including provision of binding wire including dismantling existing unserviceable fencing complete all as specifed and directed..( rails, staining bolts will be measured in seperate Item) |
| 7 | S & F in Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long and 5 to 10mm dia of shank complete all as specified and directed |
| 8 | S&F, TMT steel bars 10mm dia and over, cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specifed and directed. |
| 9 | M & L for Preparation new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specifed and directed. |
| 10 | Dismantling of barbed wire fencing of any description and any positions complete all as specified and as directed. |
| 11 | Demolition of brick work, stone/boulder masonry built in cement mortar completeall as specified and directed. |
| 12 | Demolition of cement concrete (Reinforced) of any description and any position not other wise specifically provided reinforcement cut as required to facilitate demoltion complete all as specifed and directed. |
| 13 | Demolition of cement concrete in ground floor and paving n.exc 15cm thickness(below & above GL) unreinforced complete all as specifed and directed. |
| 14 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth, for foundation, laying of cables/pipes etc, or for shaft, well, cesspits, manhole, pier holes etc, not exceeding 10Sqm on plan and not exceeding 1.5m in depth and getting out in hard/dense soil, complete all as specified and directed. |
| 15 | M&L for plain cement concrete type D-2, 1:4:8 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed. |
| 16 | M & L for TMT bars 6mm dia and over upto and incld 10mm dia as in stirrups, spacers and binders and binding with MS wire not less than 0.9mm dia (annealed) conforming to IS:1786, complete all as specified and as directed. |
| 17 | M & L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter finished fair complete all as specified and as directed |
| 18 | M & L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. finished fair complete all as specified and as directed |
| 19 | M & L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions finished fair complete all as specified and as directed |
| 20 | M&L RCC M-25 (design Mix) using 20 mm graded stone aggr as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed |
| 21 | M&L RCC M-25 (design Mix) using 20 mm graded stone aggr as in Columns, pillars, piers, posts and struts complete all as specified and as directed |
| 22 | M&L RCC M-25 (design Mix) using 20 mm graded stone aggr as in Beams, cantilevers, bressummers, lintels over1.5m span complete all as specified and as directed |
| 23 | M&L for Brick work with sub class \"B\" (old size) bricks, straight or curved on plan to any radius built in cement sand mortar 1:4, complete all as specified and directed. |
| 24 | Returning filling in, with approved excavated soil including spreading levelling watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 25 | Removing excavated material (soil) to a distance not. exc. 50 mtr and depositing where directed at a level nexc 1.5 mtr above the starting point complete all as specified and directed. |
| 26 | Taking down cement plaster on brick or stone surfaces etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specifed and directed. |
| 27 | M&L for rendering 10mm thick in cement mortar 1:4 including water proofing compound as per manufacturer instructions on fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement, complete all as specified and directed. NOTE : WPC shall be measured and paid separately. |
| 28 | M&L for rendering 15mm thick in cement mortar 1:4 including water proofing compound as per manufacturer instructions on other than fair faces of brick work finished even and smooth without using extra cement, complete all as specified and directed. NOTE : WPC shall be measured and paid separately. |
| 29 | Supply only liquid water proofing compound complete all as specified and directed. |
| 30 | S&F Galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc as complete all as specified & directed. |
| 31 | Fixing onlygalvanised 2 strand, steel barbed wire of any description(obtained from dismantling)and straining and fixing to any type of standard rails straining bolts, including aluminium paint and securing or tying at crossing with and provn of galvanised MS wire complete all as specified and as directed. |
| 32 | Fixing,Restraining,resecuring incl making good staples etc of existing barbed wire fencing complete all as specified and directed. |
| 33 | M&L Providing and fixing concertina coil fencing with punched tape concertina coil 600mm dia 10 metre openable length , having 50 Nos rounds per 6 metre length, spring core wire (2.5 mm thick) of high tensile strength of 165 Kg/Sqmm with tape (0.52mm thick) and weight 43.478 gm/ metre and fixing the same with existing Y-shape dangle iron placed 2 mapartand with 6 horizontal R.B.T (Reinforced Barbed Tape) wire, stud tied with G.I staple and GI clips to retain horizontal, incld necessary bolts, all complete as per direction of Engineer-in-Charge. |
| 34 | M&L for preparation of newly plastered surface of wall applying two coat of cement base paint over a one coat of alkali resistant primer, complete all as specified and directed. |
| 35 | S&F 18/20mm thick pre formed filler for crumple joint complete all as specified and as directed. |
| 36 | M & L Plain cement mortar (1:2:4) type B-1 using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, formwork (straight or curved complete all as specified and directed. |
| 37 | Supply and fixing Broken glass coping on top of walls in cement mortar 1:3 complete all as specified and directed. |
| 38 | M & L for Preparation ofold decorated plastered or unplastered surface including cleaning by brooming down with steel wire brushing, scraping down smoke soot, moulded, moss, efflorscent salt, trading oil and greasyspots andapplying one coat of cement base paint on walls of external surfaces complete all as specifed and directed.. |
| 39 | All as per itme no 38 above here-in-before but applying two coat of cement base paint on walls of external surfaces. complete all as specifed and directed. |
| 40 | M&L for providing precast cement concrete(type B0 1:2:4 12.5mm graded aggregate) louvres and jallies, 25mm thick (measured solid), including all mouldings and form workincluding demlation of oldlouvres and jallies complete all as specified and directed. |
| 41 | M&L 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in 15mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specifed and directed. |
| 42 | M&L for walling of random rubble uncoursed, well bonded laid dry in retaining walls, abutments and similar works complete all as specified and directed. |
| 43 | M & L for raised pointing to random rubble masnoary in CM 1:4 etc complete all as specified anddirected. |
| 44 | S & F 110mm bore PVC pipe(SWR) as in weep holes complete all as specifed and directed. |
| 45 | S&F in repair MS framed work as in grills, gratings or gates of angle or other section with necessary welding. bolting, riveting etc complete drilled for fixing of steel sheet or other covering , etc to be prepared for hanging or sliding with and including either hooks hinges so fastening and fixing complete all as specifed and directed. |
| 46 | M&L for 75 mm thick PCC1:4:8 type D-2 using 40mm graded as in sub base of floor, hard standing (40 mm graded stone aggregate), finishing even and smooth without using extra cement to received tiles including necessary form work etc completeall as specified and directed. |
| 47 | M&L in repair 60mm thick machine pressed precast concrete interlocking paver block (glossy finish) of M-35 Gde of approved shape, size and colourconferming to IS 15658-2006 and laid over and including 25mm thick gridcushion complete all as specified anddirected. |
| 48 | M&L in repair chequered cement concrete tiles with grey cementand pigment of size 30cmX30cmX25mm thick ,set and jointed and pointed in neat cement slurry in floor etc over and including 15mm thick screed bed in CM 1:6complete all as specified and directed. |