| 1 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion from cement concrete and making good disturbed ground complete all as specifed and directed. |
| 2 | Excavation for post holes in any type of soil (or in similar hole ) each n.exc 0.50 Cum including dismantling PCC including disposal of surplus n.exc 50m complete all as specifed and directed. |
| 3 | M&L forPCC 1:3:6 type C-2 (20mm graded aggts) in foundation filling and mass concrete all as specified and directed |
| 4 | M&L for posts and struts in fencing of angle, tee including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or FE 310-0 complete all as specifed and directed. |
| 5 | Fixingchain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specifed and directed. |
| 6 | Supply only Chain link fencing with or without line wires,any type andmesh size and any type of standards and dia of wire ( as directed by Engineer-in-charge) fixed with rails, staining bolts etc including provision of binding wire including dismantling existing unserviceable fencing complete all as specifed and directed..( rails, staining bolts will be measured in seperate Item) |
| 7 | S & F in Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long and 5 to 10mm dia of shank complete all as specified and directed |
| 8 | S&F, TMT steel bars 10mm dia and over, cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specifed and directed. |
| 9 | M & L for Preparation new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specifed and directed. |
| 10 | M & L for Galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc as complete all as specified & directed. |
| 11 | S&F Punched Tape Concertina Coil (including spike and handle) with 56 loops and dia 600mm, Max covered length 8 RM, having a core wire of high carbon spring steel of high tensile strength. The punched tape and copre wire (2.5 + 0.35mm dia) shall be heavy galvanized (IS-1730) (Wire-275GSM & strip-200 GSM) to provided protection against out door exposure. The punched tape shall mechanically crimped over the core wire and then formed into a coil at various parts of the periphery of the coil. The width of strip as 19mm and spacing of blades 24.00 + 0.5 mm C/C. The weight of each coil shall be 8 + 5% Kgs without packing material and coil lenth 8 Mtr (maximum) when opened up each coil would with bituminzed hessian cloth for providing protective packing Ref specification No CQAE/5660/1620/a for raw material and drawings IMGA-0112/B (Sheet 1 of 2), IMPD-1821, IMPD-1822 complete all as specified & directed. |
| 12 | Demolition of cement concrete (Reinforced) of any description and any position not other wise specifically provided reinforcement cut as required to facilitate demoltion complete all as specifed and directed. |
| 13 | M& L for Plain cement concrete type D-2, 1:4:8 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed. |
| 14 | M & L for Reinforced cement concrete (design mix) M-25 (using 20mm graded crushed stone aggregate) as in foundation including raft footing, foundation beam, plinth beam, bases of columns etc basement slab under reamed piles and mass concrete complete all as specified and directed. |
| 15 | M & L for Reinforced cement concrete (design mix) M-25 (using 20mm graded crushed stone aggregate) as in beams, cantilivers, bressummers, lintels over 1.5 m span complete all as specified and directed. |
| 16 | M & L for Reinforced cement concrete (design mix) M-25 (using 20mm graded crushed stone aggregate) as in Columns, pillars, piers, posts and struts, complete all as specified and directed. |
| 17 | Use and waste of formwork to sides of concrete foundation, footings, bases of columns, raft and raft beams, sides & soffits (if any) of foundation and plinth beams and similar work, vertical or to batter including rough finished surfaces of concrete complete all as specified and directed. |
| 18 | Use and waste of formwork to sides of pillars, struts, piers, columns and stanchions including rough finished surfaces of concrete, square, rectangular or polygonal in sections concrete, complete all as specified and directed. |
| 19 | Use and waste of form work to sides and soffits of flat, lintels etc rough finished etc complete all as specifed and directed. |
| 20 | S & F in TMT bars 10mm dia & over cut to length bent to shape required including, cranking, bending spirally, hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified and directed. |
| 21 | All as per Srl item No.20 here-in-before but 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders, complete all as specified and directed. |
| 22 | Demolition of brick work, stone/boulder masonry built in cement mortar completeall as specified and directed. |
| 23 | Brick work with sub class \"B\" (old size) bricks, straight or curved on plan to any radius built in cement sand mortar 1:6, complete all as specified and directed. |
| 24 | All as per item 23 above but except bricks complete all as specifed and directed. |
| 25 | M&L for walling of random rubble uncoursed, well bonded laid dry in retaining walls, abutments and similar works complete all as specified and directed. |
| 26 | Taking down cement plaster on brick or stone surfaces etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specifed and directed. |
| 27 | M & L for Rendering 15mm thick in cement mortar 1:4 including water proofing compound as per manufacturer instructions on other than fair faces of brick work finished even and smooth without using extra cement, complete all as specified and directed. |
| 28 | S & F mild steel of grade Fe-290 (Grade E-165) in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets ( for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. and similar work, complete all as specified and directed. |
| 29 | Dismantling of Barbed wire in fencing of any description complete all as specifed and directed. |
| 30 | S & F in repairs Galvanized, 2 strand, steel barbed wire 2.24 mm dia., barbed with 2 mm dia., barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanized mild steel pins etc.,(each line wire to be measured separatley) complete all as specifed and directed. |
| 31 | Restraining & resecuring existing barbed wire of any type incl making good staples etc any type of standard rails straining bolts including securing or tying at crossings with and provision of galvanised mild steel wire staples or steel pins etc (each line wire to be measured separatley) complete all as specifed and directed. |
| 32 | S & F in Galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc as complete all as specified & directed. |
| 33 | M&L for preparation of newly plastered surface of wall applying two coat of cement base paint over a one coat of alkali resistant primer, complete all as specified and directed. |
| 34 | M & L for Preparation ofold decorated plastered or unplastered surface including cleaning by brooming down with steel wire brushing, scraping down smoke soot, moulded, moss, efflorscent salt, trading oil and greasyspots andapplying one coat of cement base paint on walls of external surfaces complete all as specifed and directed. |
| 35 | All as per itme no 38 above here-in-before but applying two coat of cement base paint on walls of external surfaces complete all as specifed and directed. |
| 36 | M & L for Preparation of new steel surfaces or iron works of any description, over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 37 | M & L for Preparation of old painted steel surfacesof any description not otherwise described over 10cm width or girth, and applying one coat of synthetic enamel paint complete all as specified. |
| 38 | S & F in Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165complete all as specIfied. |
| 39 | M & L for Plain cement mortar (1:2:4) type B-1 using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, formwork (straight or curved complete all as specified and directed. |
| 40 | M & L for Forming square grooves in plaster n exc 12mm deep and n exc 15mm on face at junction of Rcc and brickwork complete all as specifed and directed. |
| 41 | S&F PVC 75 mm Dia (SWR) pipes single socketed, in any length with rubber ring joints,Uses as weep hole complete all as specifed and directed. |
| 42 | Supply only liquid water proofing compound complete all as specified and directed. |
| 43 | M&L for providing precast cement concrete(type B0 1:2:4 12.5mm graded aggregate) louvres and jallies, 25mm thick (measured solid), including all mouldings and form workincluding demlation of oldlouvres and jallies complete all as specified and directed. |
| 44 | M&L for walling of random rubble uncoursed, well bonded laid dry in retaining walls, abutments and similar works complete all as specified and directed. |
| 45 | Demolition of cement concrete in ground floor and paving n.exc 15cm thickness(below & above GL) unreinforced complete all as specifed and directed. |
| 46 | M&L for 75 mm thick PCC1:4:8 type D-2 using 40mm graded as in sub base of floor, hard standing (40 mm graded stone aggregate), finishing even and smooth without using extra cement to received tiles including necessary form work etc completeall as specified and directed. |
| 47 | M&L in repair 60mm thick machine pressed precast concrete interlocking paver block (glossy finish) of M-35 Gde of approved shape, size and colourconferming to IS 15658-2006 and laid over and including 25mm thick gridcushion complete all as specified anddirected. |
| 48 | M&L in repair 80mm thick machine pressed precast concrete interlocking paver block (glossy finish) of M-35 Gde of approved shape, size and colourconferming to IS 15658-2006 and laid over and including 25mm thick gridcushion complete all as specified anddirected. |
| 49 | M&L in repair chequered cement concrete tiles with grey cementand pigment of size 30cmX30cmX25mm thick ,set and jointed and pointed in neat cement slurry in floor etc over and including 15mm thick screed bed in CM 1:6complete all as specified and directed. |