| Sl. No. | Item Description |
| 1 | INTERIORFloor Base Preparation and Leveling: Preparation of existing floor by cleaning, filling, and leveling using cementitious screed mix (1:3) to achieve uniform surface finish, including surface hardener, curing, and protection for final flooring installation. |
| 2 | Vitrified Tile Flooring: Supply and installation of premium double-charged vitrified tiles (600x600mm / 800x800mm), slip-resistant, with matching skirting up to 100mm height. Joints filled with epoxy grout; includes adhesive, edge trims, and finishing. |
| 3 | Epoxy/PU Flooring for Service Zones: Supply and laying of industrial-grade self-leveling epoxy/polyurethane flooring (2–3mm thick) for high-traffic kitchen/service areas, including primer coat, leveling compound, and top sealant with anti-slip finish. |
| 4 | Gypsum False Ceiling System: Fabrication and installation of suspended ceiling using G.I. frame system with 12.5mm gypsum boards, joint treatment, and acrylic emulsion paint finish. Includes provision for cut-outs for lighting and HVAC diffusers. |
| 5 | MDF Composite Panelling with PU Finish: Fabrication and installation of decorative MDF-based composite wall panels with grooves, finished with high-quality PU paint in matte or satin finish. Panels to be factory-cut for precision and installed on concealed framework. |
| 6 | Natural Wood Veneer Cladding: Application of premium-grade natural wood veneer panels on MDF substrate, finished with melamine polish, inclusive of edge banding, adhesive, and surface protection coat. |
| 7 | Acoustic Fabric Panels: Supply and installation of fabric-covered acoustic panels with mineral wool infill for noise reduction, fixed with concealed aluminum framework as per acoustic consultant’s specification. |
| 8 | Feature Wall Finishes and Textured Paint: Surface preparation and application of decorative textured paint with graphic patterns and signage backdrops as per design intent, including protective clear coat. |
| 9 | Dining Tables: Supply and installation of dining tables (average size 3’x3’) with solid wood or HPL top, powder-coated steel base, and polyurethane protective finish. All edges to be rounded and structurally stable for public use. |
| 10 | Dining Chairs: Ergonomically designed dining chairs made of powder-coated mild steel frame with upholstered seat and backrest, finished with performance fabric suitable for high-traffic use. |
| 11 | Booth Seating Units: Custom-built fixed seating booths with wooden framework, high-density foam cushioning, leatherette/fabric upholstery, and integrated laminate-topped tables as per layout. |
| 12 | Service Counter & Back-End Furniture: Modular counter assembly comprising solid surface countertop, stainless steel kick plates, storage drawers, and display façade with branding panels; includes kitchen back-area stainless steel tables and shelving. |
| 13 | Ambient Lighting System: Supply and installation of LED recessed downlights, track lights, and cove lights (warm white 3000K) with electronic drivers, including wiring, conduits, and mounting accessories as per approved layout. |
| 14 | Feature and Decorative Lights: Designer pendant, wall-mounted, and hanging luminaires for aesthetic enhancement, including wiring and mounting. |
| 15 | Electrical Distribution & Wiring: Copper wiring with PVC conduits, modular switches, DB panels, sockets, and load balancing as per electrical consultant’s drawings and IS standards. |
| 16 | Acoustic Ceiling Panels and Baffles: Supply and installation of sound-absorbing ceiling panels/baffles made of glass wool or polyester fiber with fabric finish, suspended on MS framework as per manufacturer’s recommendation. |
| 17 | HVAC Duct Insulation and Air Diffusers: Thermal and acoustic insulation of ducts using nitrile rubber insulation, along with aluminum air diffusers and dampers installed for uniform air distribution. |
| 18 | Carpet Tiles in Lounge Zone: Installation of 500x500mm commercial-grade nylon carpet tiles with anti-static and fire-retardant backing, adhesive fixing, and trimming. |
| 19 | Wayfinding and Digital Signage: Supply and installation of internal wayfinding signage with LED backlighting, acrylic letters, stainless steel trims, and digital display boards integrated with branding content. |
| 20 | Thematic Graphics and Wall Branding: Execution of thematic artwork and wall graphics using vinyl prints, digital murals, and laser-cut logo panels as per approved design. |
| 21 | Hardware, Fixtures & Joinery Accessories: Provision of all minor joinery hardware, SS fittings, brackets, adhesive sealants, hinges, screws, and touch-up materials required for completion of works. |
| 22 | AQUASITC of minimum 35MM Acrylic Tunnel Blocks A large, curved tunnel structure made of 35 mm thick acrylic sheets (transparent plastic stronger than glass). Used in aquariums, water parks, or zoo exhibits so visitors can “walk through” while being surrounded by aquatic life. Acrylic is preferred over glass because it’s clearer, stronger, and can be molded into curved shapes. With Side Concrete Wall The acrylic tunnel is usually embedded into or supported by reinforced concrete walls. Concrete provides structural strength and stability, ensuring the tunnel withstands water pressure and external loads. |
| 23 | SITC of Tunnel Interior DécorThis is all about aesthetic design inside the acrylic tunnel to create a natural underwater environment: Artificial Rockwork & Cave Structures – made of FRP/fiber or concrete, textured and painted to look realistic. |
| 24 | SITC of minimum 25MM Acrylic Pillar Tanks |
| 25 | SITC of minimum 19mm Glass TanksThese are large display tanks made of 19 mm thick glass.Thickness (19 mm) is chosen for strength so that tanks can withstand high water pressure (especially for lengths of 6–8 feet).Used for displaying aquatic life in aquariums, tunnel side galleries, or standalone exhibits. |
| 26 | SITC of Min 19mm Glass TanksThese are large display tanks made of 19 mm thick glass.Thickness (19 mm) is chosen for strength so that tanks can withstand high water pressure (especially for lengths of 6–8 feet).Used for displaying aquatic life in aquariums, tunnel side galleries, or standalone exhibits. |
| 27 | SITC of minimum 12mm Glass TankMaterial: 12 mm clear float or toughened glass.Framing/Bracing:* Euro-bracing on top to reduce flexing.* MS/SS angle stand support (stand is covered separately |
| 28 | SITC of minimum 19mm Toughened Glass Selfie Tank* Material: 19 mm toughened safety glass (clear, low-iron for maximum transparency). |
| 29 | SITC of Glass tanks (Min 12 mm & Min 19 mm) are very heavy once filled with water.* Example:o 8’ x 2’ x 4’ (19 mm glass) ≈ 1,800 liters → ~1.8 tons of weight (water + glass).o 6’ x 2’ x 4’ tank ≈ 1.3 tons of weight.* Such loads cannot sit on wooden or flimsy structures → requirecustom steel angle stands. |
| 30 | SITC of the following items1. Oxygen Supply – deliver air via diffusers/air stones to maintain dissolved oxygen.2. Water Movement – prevent stagnant water zones inside tanks.3. Support Filtration – power under-gravel filters, sponge filters, and bio- filters.4. Backup Safety – in case of power outage to main pumps, blowers can maintain fish survival for several hours. |
| 31 | SITC of airline Inline Connection Valves* Small control valves fitted onto PVC airline pipes that distribute air from the central Air Blower.* They regulate and control air supply to each individual tank.* Installed inline (on the main or branch airline). |
| 32 | SITC of external Power Filters* External Power Filters (often called canister filters) are standalone filtration units placed outside the aquarium. |
| 33 | SITC of listed item1. Mechanical Filtration – sponges & filter floss trap solid waste.2. Biological Filtration – ceramic rings, bio balls encourage nitrifying bacteria growth.3. Chemical Filtration – activated carbon removes odors & discoloration.4. Water Oxygenation – water returning from top adds surface agitation→ increases oxygen. |
| 34 | SITC of back Glass Blue Poster* A printed or solid-colored vinyl sheet/poster fixed on the back side of aquariums.* Creates a blue background that enhances the viewing effect of fish, plants, and décor.* Standard practice in public aquariums to provide a natural ocean-likeappearance instead of showing bare walls or plumbing. |
| 35 | Supply, installation, testing, and commissioning of heater units of various capacities, aligned to the tank sizes and specifications mentioned in line items |
| 36 | Supply, installation, testing, and commissioning of stone, Gravels & SandThis item covers the substrate materials used inside aquariums for both:1. Functional purposes (biological support, anchoring plants, shelter for fish).2. Aesthetic purposes (natural look & décor). Includes:* Stones/Rocks: Large decorative pieces (basalt, slate, river stone, lava rock).* Gravel: Medium-sized pebbles (3–8 mm) for base layers.* Sand: Fine substrate (0.5–2 mm) for bottom cover. |
| 37 | Supply, installation, testing, and commissioning of Fiber Decoration & Other Artifacts (Inside Tanks) |
| 38 | Supply, installation, testing, and commissioning of fiber Decoration & Other Artifacts (Outside/Back of Tanks)Thematic decorative panels and structures made from fiber- reinforced plastic (FRP), installed outside the aquariums or on back walls to create an immersive environment for visitors.Examples include: Artificial rock backdrops & cave walls. Coral reef & ocean scene panels. Shipwrecks, ruins, or themed façades. Sculptures, textured walls, or underwater-themed murals. |
| 39 | Supply, installation, testing, and commissioning of Plantation (Live & Plastic)Aquarium plants, both live (natural aquatic plants) andplastic/artificial replicas, used for aquascaping and thematic display.* Live Plants: True aquatic species (grow underwater, support ecosystem).* Plastic Plants: High-quality, aquarium-safe replicas used where real plants cannot survive (marine tanks, low-light tanks, or purelydecorative setups). |
| 40 | Supply, installation, testing, and commissioning of the listed items1. Aquarium Accessorieso Nets, scrapers, magnets for glass cleaning.o Suction cups, clamps, tubing extras.o Spare pipes, joints, valves.2. Consumableso Water conditioners, dechlorinators, pH buffers.o Test kits for ammonia, nitrate, nitrite, salinity.o Salt mix for marine tanks.3. Maintenance & Safetyo Backup heaters, spare lights.o Waterproof gloves, tools for handling tanks.o Safety gear for staff.4. Small Décor/Enhancementso Additional fiber props, shells, driftwood replicas.o Small background stickers, tank labeling plates.5. Logistics & Handlingo Packaging material, protective sheets.o Local transport of small items.o Loading/unloading support. |
| 41 | Supply, installation, testing, and commissioning of Aqua-LightsAquarium lighting systems designed to enhance the visual appealof tanks while also supporting the biological needs of fish, corals, and plants. |
| 42 | Supply, installation, testing, and commissioning of Front Panel Covering of All TanksAesthetic and protective coverings applied to the front-facing panels of all aquariums, which visitors see.It’s not the tank glass itself, but the finishing framework & cladding that:* Enhances presentation.* Conceals structural/support elements. Provides a uniform professional look. |
| 43 | ◆ Functions1. Main Attraction – the live fish & aquatic animals are the soul of the aquarium project.2. Thematic Display – freshwater, marine, Amazon, coral reef, and selfie tanks require different species.3. Biodiversity Showcase – educates visitors about aquatic ecosystems.4. Revenue Driver – unique or exotic species are the main draw for tourism & ticketing. |
| 44 | SITC of all logistics, handling, installation, and on-site fabrication activities required to bring the aquarium project to life after procurement of tanks, equipment, décor, and live stock.It ensures that all components — from massive acrylic panels to delicate fish— are safely transported, installed, and commissioned. |
| 45 | HVACFour Way Cassette type VRF Indoor UnitsSupply, installation, testing and commissioning of following minimu capacity 4- way/2 way/radial flow as per approval VRV Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, max noise level 60dB @ 400 cfm per TR(minimum) complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature fresh airprovision compatible for Remote2.0 TR Four Way Cassette type AC Unit |
| 46 | 3.2 TR Four Way Cassette type AC Unit |
| 47 | 4.0 TR Four Way Cassette type AC Unit |
| 48 | Outdoor Units of VRF System24.0 HP Capacity |
| 49 | 26.0 HP Capacity |
| 50 | VRF System Remote ControllerSupply / Installation / Testing and Commissioning of Cordlesss remotes for VRF indoor units( For Hi Wall Type IDUs ) |
| 51 | 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thickinsulation |
| 52 | 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thickinsulation |
| 53 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thickinsulation |
| 54 | 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thickinsulation |
| 55 | 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thickinsulation |
| 56 | 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thickinsulation |
| 57 | 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thickinsulation |
| 58 | 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thickinsulation |
| 59 | 24.0 HP Capacity |
| 60 | 26.0 HP Capacity |
| 61 | outdoor units of suitable size as per requirement. As perspecification/drawings and as directed by Engineer In Charge. |
| 62 | 2CX 1.5 Sq.mm |
| 63 | Power Cabling to individual Outdoor units with PVC conduits. ( From Power Panel to VRF ODU ) |
| 64 | Supply,instalation,estingnd Commissioning of canera Mounting,1 xNetwork Video Recorder (NVR) 2MP/4 Channel/ H265 + compression/ 1SATA/ 2TB Storag Managed Switch,1x3 KVA Online 15min Battery Backup (Legrand/Vertiv), NetworkCable, Connectors, Outdoor Cubical Rack (IP66) and other Associate Accessories complete and inculuding CMC and AMC. |
| 65 | Communication Cable between Outdoor Units & Indoor Units with PVC conduits |
| 66 | Transportastion , Lifitng and Shifting at Site |
| 67 | Excavation in foundation in ordinary soil, loam, clay or sand including lift upto 1.5 m & lead upto 30m Including filling watering & ramming of excavated earth into the trenches or into the space between the building & the sides of foundation trenches or in to the plinth removal & disposal of surplus earth as directed by the engineer in charge upto a distance of 30m from the foundation |
| 68 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. from the site of work & including watering, dressing etc. Rate includes cost of all materials, labour and T&P etc. required for proper completion of the work. (including royalty) |
| 69 | Cement concrete with 4 cm. (1½\") gauge approved stone, ballast, approved coarse sand and cement in the proportion of 8:4:1 including supply of all materials, labour and T&P etc. |
| 70 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement contentin design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M25 grade with minimum cement content of 300 kg /cum (All works upto plinth level :) |
| 71 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M25 grade with minimum cement content of 300 kg /cum (All works upto plinth level :) |
| 72 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement contentin design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra Concrete of M25 grade with minimum cementcontent of 300 kg /cum (All works above plinth and upto floor V level) |
| 73 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement contentin design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra Concrete of M25 grade with minimum cementcontent of 300 kg /cum (All works above plinth and upto floor V level) |
| 74 | First Class brick work in 1 : 4 cement & fine coarse sand mortar in foundation & plinth including supply of all materials labour & tools and plants etc. required for proper completion of the work. |
| 75 | First Class brick work in 1 : 4 cement & fine coarse sand mortar in super structure, including necessary cutting and moulding of bricks as required and also including honey comb brick work. Thickness of wall not to be less than 1.5 brick thick. |
| 76 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5 mm nominal size derived from natural sources) |
| 77 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 78 | Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement: 3 fine sand) : Flush / Ruled/ Struck or weathered pointing |
| 79 | 15mm thick cement plaster with cement mortar in proportion of 1:4 cement and coarse sand. |
| 80 | Mild steel or iron in plain work such as reinforced concrete or reinforced brick- work (when not included in an over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and wastage and over lapping & hooks |
| 81 | Providing and laying rectified glazed ceramic floor tiles of size 600x600 mm, of 1st quality conforming to IS:15622, of approved make, in all colours, shades, except white, ivory, grey, fume red brown, laid on 20 mm thik cement mortar 1:4, jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 82 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured. |
| 83 | Finishing walls with water proof cement paint of aprooved make and quality on new work with two coats to give an even shade, including supply of all material, labour and T&P etc. required for proper compilation of the work. |
| 84 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) |
| 85 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC contentless than 50 gram/litre |
| 86 | Providing and fixing Ist quality ceramic glazedtiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 87 | Excavation in foundation in ordinary soil, loam, clay or sand including lift upto 1.5 m & lead upto 30m Including filling watering & ramming of excavated earth into the trenches or into the space between the building & the sides of foundation trenches or in to the plinth removal & disposal of surplus earth as directed by the engineer in charge upto a distance of 30m from the foundation |
| 88 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. from the site of work & including watering, dressing etc. Rate includes cost of all materials, labour and T&P etc. required for proper completion of the work. (including royalty) |
| 89 | Cement concrete with 4 cm. (1½\") gauge approved stone, ballast, approved coarse sand and cement in the proportion of 8:4:1 including supply of all materials, labour and T&P etc. |
| 90 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement contentin design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.Concrete of M25 grade with minimum cementcontent of 300 kg /cum (All works upto plinth level ) |
| 91 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement contentin design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra Concrete of M25 grade with minimum cementcontent of 300 kg /cum (All works above plinth and upto floor V level) |
| 92 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement contentin design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra Concrete of M25 grade with minimum cementcontent of 300 kg /cum (All works above plinth and upto floor V level) |
| 93 | First Class brick work in 1 : 4 cement & fine coarse sand mortar in foundation & plinth including supply of all materials labour & tools and plants etc. required for proper completion of the work. |
| 94 | First Class brick work in 1 : 4 cement & fine coarse sand mortar in super structure, including necessary cutting and moulding of bricks as required and also including honey comb brick work. Thickness of wall not to be less than 1.5 brick thick. |
| 95 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5 mm nominal size derived from natural sources) |
| 96 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 97 | Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement: 3 fine sand) : Flush / Ruled/ Struck or weathered pointing |
| 98 | 15mm thick cement plaster with cement mortar in proportion of 1:4 cement and coarse sand. |
| 99 | Mild steel or iron in plain work such as reinforced concrete or reinforced brick- work (when not included in an over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and wastage and over lapping & hooks |
| 100 | Providing and laying rectified glazed ceramic floor tiles of size 600x600 mm, of 1st quality conforming to IS:15622, of approved make, in all colours, shades, except white, ivory, grey, fume red brown, laid on 20 mm thik cement mortar 1:4, jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 101 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured. |
| 102 | Finishing walls with water proof cement paint of aprooved make and quality on new work with two coats to give an even shade, including supply of all material, labour and T&P etc. required for proper compilation of the work. |
| 103 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:13.47.1 New work (Two or more coats applied @ 1.43 ltr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) |
| 104 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC contentless than 50 gram/litre |
| 105 | Providing and fixing Ist quality ceramic glazedtiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 106 | DOOR/ WINDOWS/FALSE CEILING - AQUA WORLDProviding and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns as per CPWDSpecification 2019, to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm and secondaryintermediate cross-T of size 24x32 mm of length 600 mm to formgrid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6 mm thick with precut hole on both 25 mm flange to pierce into 12x50 mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directionsof the Engineer-in-Charge. With 15 mm thick tegular/butt edged without perforation plain/designer light weight calcium silicate Anti-Microbial Bio-Safe coated false ceiling tiles Confirming to JIS-Z2801 and ASTM G-21 |
| 107 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Teesections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 108 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. |
| 109 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 110 | Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.Using R3 series with frame (98mm & above) x (40mm & above) & both glazed and fly screen sash (30mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height upto 1.8m). |
| 111 | Fixed window / ventilator with mullion / transom.Using R1 series with frame (33mm & above ) x (35mm & above) & mullion (33mm & above) x (50mm & above). (Height upto 0.90 metre) |
| 112 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns as per CPWDSpecification 2019, to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm and secondaryintermediate cross-T of size24x32 mm of length 600 mm to formgrid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6 mm thick with precut hole on both 25 mm flange to pierce into 12x50 mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directionsof the Engineer-in-Charge. With 15 mm thick tegular/butt edged without perforation plain/designer light weight calcium silicate Anti-Microbial Bio-Safe coated false ceiling tiles Confirming to JIS-Z2801 and ASTM G-21 |
| 113 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Teesections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 114 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. |
| 115 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 116 | Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.Using R3 series with frame (98mm & above) x (40mm & above) & both glazed and fly screen sash (30mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height upto 1.8m). |
| 117 | Fixed window / ventilator with mullion / transom.Using R1 series with frame (33mm & above ) x (35mm & above) & mullion (33mm & above) x (50mm & above). (Height upto 0.90 metre) |
| 118 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 119 | Supply & fixing of power plug with 15 amp 250 volts flush type switch & 5 pin 15 amp 250 volts flush type socket in suitable M.S. box of 175 mm * 100mm * 50 mm size with bakelite sheet cover 3 mm thick fixed with brass machine screws & washers complete in all respect. |
| 120 | Supply & wiring of sub main with FR P.V.C. insulated 1100 volts grade single core copper conductor cable in heavy gauge P.V.C. coduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting complete with FR PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit.2 x 4.00 sq. mm. With 1 x 2.5 sq.mm. Earth wire In 20 mm dia conduit. |
| 121 | 2x 6 sq. mm. With 1 x 4 sq.mm. Earth wire In 25 mm dia conduit. |
| 122 | 2 x 16 sq. mm. With 1 x 10 sq.mm. Earth wire In 32 mm dia conduit. |
| 123 | Supply and laying of heavy duty PVC conduit complete with bend and other accessories as required and 14 S.W.G. fish steel wire etc. in slab alongwith reinforcement before concreting and plastering complete in all respects.20 mm dia. PVc conduit |
| 124 | 25 mm dia. PVC conduit |
| 125 | S/F of surface / flush mounting TPN Distribution board without MCB complete in all respects as directed at site 12 WAYS Cat(A) |
| 126 | Supply and fixing of 6 Amp to 32 Amp MCB(10KA)C Curve Cat(A) |
| 127 | Supply Fixing and making commection of 30 MA E.L.C.B. (Earth leakage circuit breaker) of din/R.C.C.B. rail mounting complete in all respects as per direction and satisfaction of engineer-in-charge.40 Amp 2 Pole |
| 128 | Supply & burrying of safe earthing electrode T-39 (Hot Dip Galvanized), Length up to 3000mm, outer pipe 76mm inner Dia 38mm terminal Dia 12mm, outer GI pipe of 16 SWG and inner GI pipe of 12 SWG with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixtuer (CCM) Having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of rataining capacity along with 30cm squre C.I. frame with hinged cover & masonry housing. (From electrode terminal to switch board, cost of 25 x 3 GI, strip will be extra)Make:as approved in U.P.P.W.D., & C.P.R.I. Certified |
| 129 | Supply & Laying of 25mm x 3mm G. I. strip from earth electrode directly in the ground as required complete in all respect. |
| 130 | S/F of single light wall bracket on matching M.D.F.E.G. board base etc. complete in all respects.Category AAA |
| 131 | Supply & fixing of Recess/Surface/Pendent mounting round 6 to 8 Watt LED down lighter having powder coated die cast Aluminium housing with heat sink, diffuser/reflecter, and driver set complete in all respect. Category AAA |
| 132 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube on surface complete in all respect.Category AAA |
| 133 | Supply and Fixing of LED Tube Light with batten suitable for up to 2X22 watt LED tube light fitting complete including tube on surface complete in all respect.Category AAA |
| 134 | Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects. |
| 135 | Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects. |
| 136 | Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. |
| 137 | Supply & fixing hexagonal/Round G.P. Fan box of approved make made up of 1.0 mm thick ISI marked G.P. Sheet spot welded four to Eight holes of 25.4mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screwed fitted with 300mm round zink coated M.S. Bar x 12mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material labour, T & P etc required for proper completion of the work. |
| 138 | S/F of danger board fabricated from 10 gauge M.S. sheet as per E/I rules. |
| 139 | Supply & Erection of factory fabricate & wired metal clad dust and vernim proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB\"s (Four pole 36 KA with thermal magnetic release) switches complete and instrument chamber etc. completed in all respects. The instrument chamber shall be seprated and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F, KW etc) in each phase with touch type selector switches for different readings , intrument fuses, current transformer etc. the panel board shall have suitable capacity electrolytic aluminium busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB\"s shall be completed with suitable cable and boxes, compression glands and indicating lamp on incoming etc. The job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have Ammeter.The panel board shall be fabricated with CRCA shee with a minimum thicness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B only.Incoming 200Amp. MCCB-1No. Outgoing 100 Amp MCCB-1 No & 63 Amp MCCB-3Nos |
| 140 | Supply & erection of AC 1200mm Sweep, 220/240 Volts, 50 Hz ceilling fan with standard down rod, blades including connection etc. complete as required-BEE-5 Star rated |
| 141 | Supply & erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required-Make: USHA Cat No. TURBO JET DLX300 mm sweep |
| 142 | E-ELECTRICALWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 143 | Supply & fixing of power plug with 15 amp 250 volts flush type switch & 5 pin 15 amp 250 volts flush type socket in suitable M.S. box of 175 mm * 100mm * 50 mm size with bakelite sheet cover 3 mm thick fixed with brass machine screws & washers complete in all respect. |
| 144 | Supply & wiring of sub main with FR P.V.C. insulated 1100 volts grade single core copper conductor cable in heavy gauge P.V.C. coduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting complete with FR PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit.2 x 4.00 sq. mm. With 1 x 2.5 sq.mm. Earth wire In 20 mm dia conduit. |
| 145 | 2x 6 sq. mm. With 1 x 4 sq.mm. Earth wire In 25 mm dia conduit. |
| 146 | 2 x 16 sq. mm. With 1 x 10 sq.mm. Earth wire In 32 mm dia conduit. |
| 147 | Supply and laying of heavy duty PVC conduit complete with bend and other accessories as required and 14 S.W.G. fish steel wire etc. in slab alongwith reinforcement before concreting and plastering complete in all respects.20 mm dia. PVc conduit |
| 148 | 25 mm dia. PVC conduit |
| 149 | S/F of surface / flush mounting TPN Distribution board without MCB complete in all respects as directed at site .12 WAYS Cat(A) |
| 150 | Supply and fixing of 6 Amp to 32 Amp MCB(10KA)C Curve Cat(A) |
| 151 | Supply Fixing and making commection of 30 MA E.L.C.B. (Earth leakage circuit breaker) of din/R.C.C.B. rail mounting complete in all respects as per direction and satisfaction of engineer-in-charge.40 Amp 2 Pole |
| 152 | Supply & burrying of safe earthing electrode T-39 (Hot Dip Galvanized), Length up to 3000mm, outer pipe 76mm inner Dia 38mm terminal Dia 12mm, outer GI pipe of 16 SWG and inner GI pipe of 12 SWG with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixtuer (CCM) Having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of rataining capacity along with 30cm squre C.I. frame with hinged cover & masonry housing. (From electrode terminal to switch board, cost of 25 x 3 GI, strip will be extra)Make:as approved in U.P.P.W.D., & C.P.R.I. Certified |
| 153 | Supply & Laying of 25mm x 3mm G. I. strip from earth electrode directly in the ground as required complete in all respect. |
| 154 | S/F of single light wall bracket on matching M.D.F.E.G. board base etc. complete in all respects.Category AAA |
| 155 | Supply & fixing of Recess/Surface/Pendent mounting round 6 to 8 Watt LED down lighter having powder coated die cast Aluminium housing with heat sink, diffuser/reflecter, and driver set complete in all respect. Category AAA |
| 156 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube on surface complete in all respect.Category AAA |
| 157 | Supply and Fixing of LED Tube Light with batten suitable for up to 2X22 watt LED tube light fitting complete including tube on surface complete in all respect.Category AAA |
| 158 | Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects. |
| 159 | Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects. |
| 160 | Supply and fixing of 16 gauge MS drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. |
| 161 | Supply & fixing hexagonal/Round G.P. Fan box of approved make made up of 1.0 mm thick ISI marked G.P. Sheet spot welded four to Eight holes of 25.4mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screwed fitted with 300mm round zink coated M.S. Bar x 12mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material labour, T & P etc required for proper completion of the work. |
| 162 | S/F of danger board fabricated from 10 gauge M.S. sheet as per E/I rules. |
| 163 | Supply & Erection of factory fabricate & wired metal clad dust and vernim proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB\"s (Four pole 36 KA with thermal magnetic release) switches complete and instrument chamber etc. completed in all respects. The instrument chamber shall be seprated and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F, KW etc) in each phase with touch type selector switches for different readings , intrument fuses, current transformer etc. the panel board shall have suitable capacity electrolytic aluminium busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB\"s shall be completed with suitable cable and boxes, compression glands and indicating lamp on incoming etc. The job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have Ammeter.The panel board shall be fabricated with CRCA shee with a minimum thicness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B only.Incoming 200Amp. MCCB-1No. Outgoing 100 Amp MCCB-1 No & 63 Amp MCCB-3Nos |
| 164 | Supply & erection of AC 1200mm Sweep, 220/240 Volts, 50 Hz ceilling fan with standard down rod, blades including connection etc. complete as required-BEE-5 Star rated |
| 165 | Supply & erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required-Make: USHA Cat No. TURBO JET DLX300 mm sweep |
| 166 | E-PLUMBINGProviding and fixing soil, waste and vent pipes :100 mm diaCentrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 |
| 167 | Providing and fixing fittings/ accessories for C.I. PipeProviding and fixing collar :100 mmSand cast iron S&S as per IS - 3989 |
| 168 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 mm dia Sand cast iron S&S as per IS - 3989 |
| 169 | Providing and fixing heel rest sanitary bend100mm diaSand cast iron S&S as per IS - 3989 |
| 170 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast Iron/Cast Iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :100 mm dia pipe |
| 171 | Providing and fixing 100 mm dia C.P. grating of approved quality and colour |
| 172 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter :100 mm |
| 173 | E-PLUMBINGProviding and fixing soil, waste and vent pipes :100 mm diaCentrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 |
| 174 | Providing and fixing fittings/ accessories for C.I. PipeProviding and fixing collar :100 mmSand cast iron S&S as per IS - 3989 |
| 175 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 mm dia Sand cast iron S&S as per IS - 3989 |
| 176 | Providing and fixing heel rest sanitary bend100mm diaSand cast iron S&S as per IS - 3989 |
| 177 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast Iron/Cast Iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. :100 mm dia pipe |
| 178 | Providing and fixing 100 mm dia C.P. grating of approved quality and colour |
| 179 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter :100 mm |
| 180 | UNDERGROUND TANK Excavation in foundation in ordinary soil, loam, clay or sand including lift upto 1.5 m & lead upto 30m Including filling watering & ramming of excavated earth into the trenches or into the space between the building & the sides of foundation trenches or in to the plinth removal & disposal of surplus earth as directed by the engineer in charge upto a distance of 30m from the foundation |
| 181 | Cement concrete with 4 cm. (1½\") gauge approved stone, ballast, approved coarse sand and cement in the proportion of 8:4:1 including supply of all materials, labour and T&P etc. |
| 182 | Providing and laying in position ready mixed or site batched design mixcement concrete for plain cement concrete work; using coarse aggregateand fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommendedproportions as per IS: 9103 to accelerate / retard setting of concrete, toimprove durability and workability without impairing strength; includingpumping of concrete to site of laying, curing, carriage for all leads; butexcluding the cost of centering, shuttering and finishing as per directionof the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement contentin design mix shall be payable separately. In case the cement contentin design mix is more than 110% of the minimum specified cementcontent, the contractor shall have discretion to either re-design the mixor bear the cost of extra cement. Concrete of M25 grade with minimum cementcontent of 300 kg /cum (All works upto plinth level :) |
| 183 | Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform |
| 184 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 185 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 186 | 15 mm cement plaster in single coat on plinth 1 cement: 4 course sand in plinth. |
| 187 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar |
| 188 | Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg |
| 189 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. |
| 190 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe |
| 191 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round P.V.C. pipes including bed concrete as per standard design:150 mm diameter P.V.C. pipe |
| 192 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 193 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 194 | WATER TREATMENT PLANTExcavation in foundation in ordinary soil, loam, clay or sand including lift upto 1.5 m & lead upto 30m Including filling watering & ramming of excavated earth into the trenches or into the space between the building & the sides of foundation trenches or in to the plinth removal & disposal of surplus earth as directed by the engineer in charge upto a distance of 30m from the foundation |
| 195 | Cement concrete with 4 cm. (1½\") gauge approved stone, ballast, approved coarse sand and cement in the proportion of 8:4:1 including supply of all materials, labour and T&P etc. |
| 196 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). Slabs |
| 197 | Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform |
| 198 | R.C.C. work with cement approved course sand & 2 cm (3/4’’) gauge approved stone ballast in the proportion 1 : 1.5 : 3 ( 1 cement : 1.5 sand : 3 agg.) in walls excluding supply of reinforcement and its bending but including its fixing and bending the same with 24 B.W.G. G.I. binding wire and including necessary centering & shuttering etc. & also including supply of all materials, labour and T.P. etc. required for completion of work. Binding wire cost being included in the item. |
| 199 | Mild steel or iron in plain work such as reinforced concrete or reinforced brick- work (when not included in an over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and wastage and over lapping & hooks |
| 200 | 15 mm cement plaster in single coat on plinth 1 cement: 4 course sand in plinth. |
| 201 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar |
| 202 | Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg |
| 203 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. |
| 204 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm dia. R.C.C. pipe |
| 205 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round P.V.C. pipes including bed concrete as per standard design:150 mm diameter P.V.C. pipe |
| 206 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 207 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 208 | External fire hydrant landing valve with stand post |
| 209 | 100 mm dia MS heavy-duty external ring main |
| 210 | 100 mm dia MS vertical riser |
| 211 | Internal hydrant landing valve with hose cabinet |
| 212 | 63 mm dia hose reel |
| 213 | 65 mm dia MS branch piping |
| 214 | Fire stopping for riser |
| 215 | Automatic sprinkler heads |
| 216 | 32 mm MS branch lines |
| 217 | 65 mm MS header |
| 218 | Sprinkler test & drain assembly |
| 219 | Flexible sprinkler drops |
| 220 | Addressable fire alarm control panel |
| 221 | Smoke/heat detectors |
| 222 | Manual call points |
| 223 | Hooters with flasher |
| 224 | FRLS fire alarm cable |
| 225 | Response indicators |
| 226 | Programming & integration |
| 227 | 6 kg ABC extinguishers |
| 228 | 4.5 kg CO2 extinguishers |
| 229 | 9 L foam/water extinguishers |
| 230 | Commissioning of extinguishers |
| 231 | Fire water storage tank |
| 232 | Electric fire pump |
| 233 | Diesel fire pump |
| 234 | Jockey pump |
| 235 | Pump control panel |
| 236 | Suction & delivery piping |
| 237 | Power & control cabling |
| 238 | Earthing works |
| 239 | Photoluminescent exit signs |
| 240 | LED exit sign boards |
| 241 | Floor path marking |
| 242 | Fire escape route plans |
| 243 | Training session |
| 244 | Hydraulic testing |
| 245 | System commissioning |
| 246 | As-built drawings & documentation Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |