| 1 | Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 2 | Group C |
| 3 | Wiring for light / power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 4 | Wiring for light/ power plug with 4X4 sq. mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 2 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 5 | Wiring for circuit / submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required |
| 6 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 7 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 8 | 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire |
| 9 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 10 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 11 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 12 | 2 x 1.5 sq. mm |
| 13 | 3 x 1.5 sq. mm |
| 14 | 4 x 1.5 sq. mm |
| 15 | 5 x 1.5 sq. mm |
| 16 | 6 x 1.5 sq. mm |
| 17 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 18 | 20 mm |
| 19 | 25 mm |
| 20 | Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 21 | 5/6 amps switch |
| 22 | 15/16 amp switch |
| 23 | 3 pin 5/6 amp socket outlet |
| 24 | 6 pin 15/16 amp socket outlet |
| 25 | Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches in recess etc as required. |
| 26 | 4 Module (125mmX75mm) |
| 27 | 6 Module (200mmX75mm) |
| 28 | 8 Module (125mmX125mm) |
| 29 | 12 Module (200mmX150mm) |
| 30 | Supplying and fixing musical / Ding Dong call bell suitable for D.C./A.C. single phase, 230 volts, complete as required. |
| 31 | Supplying and fixing Two Module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 32 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 33 | Supplying and fixing 3 pin 5 Amp Ceiling Rose on the existing junction box/wooden block including connection etc. as required. |
| 34 | Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 35 | 125 Amp, 16 KA, TPMCCB |
| 36 | 160 Amp, 16 KA, TPMCCB |
| 37 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB\"s (but without MCB\"s and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 38 | 4 way (4 + 12), Double door |
| 39 | 8 way (4 + 24), Double door |
| 40 | 12 way (4 + 36), Double door |
| 41 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 42 | Single pole |
| 43 | Single pole and neutral |
| 44 | Double pole |
| 45 | Triple pole |
| 46 | Triple pole and neutral |
| 47 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \"C\" curve SPN MCB complete with connections, testing and commissioning etc. as required. |
| 48 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 49 | 63 amps |
| 50 | 100 amps |
| 51 | Supplying of following sizes XLPE insulated PVC inner sheathed Copper/Aluminium conductor Armoured /un-Armoured cable of 650/1100V grade conforming to IS: 7098(Part 1) 1988 with upto date amendments, including laying in the existing RCC/ HUME/ METAL pipe or fixing on wall surface with suitable clamps or in the existing masonry open duct etc. as required. |
| 52 | 3½ X 35 sq. mm Aluminium Conductor Armoured Cable |
| 53 | 3½ X 50 sq. mm Aluminium Conductor Armoured Cable |
| 54 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 55 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 56 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 57 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 58 | 3½ X 35 sq. mm (32mm) |
| 59 | 3½ X 50 sq. mm (35mm) |
| 60 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 61 | Supply, Installation, Testing and Commissioning of 4 feet, 20 Watts (+/- 2 Watts) energy efficient linear box LED batten light having 6500K colour temp., minimum 1900 Lumens, 95 Lumen/watt efficacy and0.9 power factor along with all accessories suitable for operation on 230 Volts, 50 Hz Single Phase AC Supply complete as required. |
| 62 | SITC of 300 mm sweep fresh air fan With metallic body and net i/c connection with 2x1.5 sqmm cu. Conductor FR PVC cable etc as reqd at site. ( M/s Havells Ventilair-DS or Equivalent model of Usha, Bajaj, Khaitanor other similar superior make ). |
| 63 | Supplying and Fixing 36 Watt, 600mm x 600mm (Nominal dimension) size, 36 Watt, Recess Mounted LED Luminaires in Metallic CRCA Powder Coated Housing, High efficiency Diffuser & integrated electronic driver slim LED Light Fitting which provides soft-light and glare-free symmetrical illumination complete with accessories i/c connection with 1.5 sq.mm copper conductor wire, testing as required.(Philips/Crompton/Havells or Similar Superior Make &Model to be got approved before supply). |
| 64 | SITC of18 W Surface mounted Squre slim panel LED downlighter with LED and all other accessorieson ceiling suitable for 240Volts AC supplyi/c connection with 1.5 sq.mm. copper conductor wire etc. as reqd. (Philips/Crompton/Havells or Similar Superior Make &Model to be got approved before supply). |