| 1 | Description and specification of items of work to be executed (complete work) |
| 2 | Provision for removal of modern brick work manually including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge. |
| 3 | Provision for removal of damaged doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead. |
| 4 | Providing and fixing wood frame in doors, windows, clerestory window, and other frames, fixed in position with hold fast and lug angle etc. in sal wood |
| 5 | Providing and fixing panelled or panelled and glazed shutters for doors, windows, clerestory window fixed with butt hings with necessary screw of required sizeas pre direction of engineer incharge 2nd class teak wood 30 mm thick |
| 6 | Providing and fixing aluminium fixtures for doors, windows etc like sliding door bolts, tower bolt, handle, hold fast etc . All complete. |
| 7 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty, Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm |
| 8 | Excavation in earthwork by mannual means /mechanical means in foundation trenches including dressing of sides and ramming of bottome for all lilft including getting out excavated soil and disposal of surplus soil upto 50m. |
| 9 | Providing and laying of PCCplain cement concrete 100 mm in foundation trenches and apron /pathwayof ratio (1:3:6) 1 cement : 3 coarse sand natural : 6 aggregate 20 mm nominal size natural aggregates. |
| 10 | Provision for brick work with common burnt clay brick of class designation 7.5 in foundation and plinth with cement mortar ratio (1:4) 1 cement : 4 coarse sand |
| 11 | Provision for laying brick tile edge in apron in composite mortar 1:4 (1 cement, 4 coarse sand) over bed of 20mm thick mortar including filling of joints. Curing all complete |
| 12 | Provision for pointing on tile brick work with cement mortar 1:3 (1 cement : 3 fine sand) after raking, cleaning and washing of joints complete. |
| 13 | Providing and fixing MS gate of 12 mm squar bar 100 mm cc angle frame 50x50x6 mm and bracing including holdfast fixation in position. |
| 14 | Provision for reinforced cement concrete in plinth beam, column, wall etc upto plinth level excluding the cost ofcentring, shuttering, reinforcement with ratio 1:1.5:3 (1 cement : 1.5 coarse agg. : agg 20 mm nominal size natural agg. |
| 15 | Provision for centering and shuttering including strutting, propping and removal of form for foundation column, plinth beams etc all complete |
| 16 | Provision for steel reinforcement for RCC work including straightening,cutting, bending, placing in position and binding all complete upto fifth floorusing TMT bar Fe 500D or more |
| 17 | Provision for cement plaster 12 mm thick outer side the foundation wall upto plinth level with cement mortar ratio 1:4 ( 1 cement : 4 fine sand) with combination of water proofing compound. |
| 18 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr/10 sqm (inner side white and outer side pink matching with old pattern ) |
| 19 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 20 | Providing and laying vitrified floor tiles with water absorption less than 0.08%and conforming to IS 15622, of approved make, in all color and shades laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete. size of tile 500x500 mm. |
| 21 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. (Hot finished welded tube types) |
| 22 | Providing and fixing PUF (Polyurethane Foam) panel of core thickness 50mm having density 40kg/cum and Thermal Conductivity at 10°C (Mean Temperature) 0.023 W/mk in roof complete with all accessories as per the direction of Engineer-in-charge. |
| 23 | Providing and fixing of Everest vertical fibre cement boards or PUF (Polyurethane Foam) panel of thickness 75mm having density not less than 700-800 kg/cum along with GI channels and all accessories in walls and partitions complete as per the direction of Engineer-in-charge. |
| 24 | Providing and fixing PVCrain water gutters 75 mm dia on sides of roof slope and below to ground level in cluding joining and sealing ring conferming IS 5382 and all fixtures . |
| 25 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangersof 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size specification and direction of the Engineer in Charge but excluding the cost of painting with Fully Perforated Gypsum Plaster Board of size 1200 x 2400 x 12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer-in-charge. |
| 26 | Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi- chambered frame, sash and mullion/coupler (where ever required) galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia withplastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded /mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. |
| 27 | Provision of lighting at the monument by providing solar lights of 120 watts LED with inbuilt solar panel of 5V 8W, inbuilt battery of 3.2V 25AH life Po4 and inbuilt radar sensor for movement tracking on a MS pole of 2.5 inch dia and 6 meter height including fitting and installation in cement concrete base size 400x400 and 300 mm above the GL and 600 mm below GL at the site with foot bracket and necessary bolts etc all complete |
| 28 | Providing and installation of CCTV- 3 no PTZ HD4K recording 360 degree revolving type camera (hikvision) over 7 m long MS pole 3 inch diaand 5 nos. bullet HD 5MP IP camera (hikvision) LED TV 42 inch(sumsung, LG etc) ,16 channel 5 megapixel and 8 TB Sata Hard Disk Network Video Recorder (NVR)of 30 days backup capacity, electric cable,PVC insulated Type A (4+1) RG59 coaxial copper CCTV camera cable , laying of 63mm dia (OD-63mm & ID-51mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75cm below ground level) including excavation and refilling the trench, fitting of all media connector, bracket, box, racks pole on concretebase size 400X400and 300 mm above the GL and 600 mm below GL at the site with foot bracket and necessary bolts etc all complete. |
| 29 | Providing and installation of branded electric appliances and fitting such as 2 no split AC 2 ton (voltas, lloyed) with stablizer &all fitting 5star(lloyd, voltas etc), 1 nos. (75 inches) 4K Ultra HDLED TV (LG, sumsung, sony), 2 nos. ceiling fan 1200 mm 50watts(khetan, orient etc), 2nos. exhaust fan50watts, 8 nos. fixing false ceiling LED lignt 20 watt such as (phillips/orient), 1 nos. Inverter & 2 nos. Battery Combo with Trolley for 1100 (900VA/12V) Pure Sine Wave Inverter + RC18000 150Ah Tall Tubular Battery | 36M Warranty on Inverter & Battery and all essential electric wiring single core 1.5sqm PVC insulated copper cable with pvc pipe, power points, plugs, conductor, sockets board, MCB RCCB box & GI boxof ISI standards for AC, TV, Inverter, fan, some extra pointsincludingall fitting charges all complete |
| 30 | Providing fixing & installation of sanitary/plumbing fittings such as nos. wall mounted WC size780x370x690 with all fittings,nos. wash basin size 550x400mm with all fittings, 1 nos. stainless kitchen sink size 610x460x200 with all fittings, 8 nos. waste pipe, 1000 ltr water storage tank, 1 nos. C.P. brass health faucet, 1no. 600x450 mm beveled edge mirror of superior glass, 1nos, PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide,5 nos. C.P. brass long nose bib cock, 2nos. C.P. brass stop cock,repairing of water supply pipes and vent pipes 100 mm dia UPVC pipe with S/P trap, SS cleanout, fitting , couplers, bends, tees, socket etc including fixing at wall/ceiling level supported by clamp and hanger all connection to outlets, PVC rain water pipes confirming IS 13592 type, Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site including joining , all connection inlet and outletscomplete |
| 31 | Provision for providing and installing portable cabin for watch and ward staff of size 2.44 m (L) x 2.44 m(W) x 3.0 m(H) m in off white colour over a as per specifications given below. Walls 50mm thickness Insulated panels with cam-lock interlocking system with pre-painted on the wall. Roof One side slope roof with water resistance technique. Roof will be provided so that water cannot come inside the shelter. Floor MS tube frame with wooden ply of 19mm finish with vinyl flooring mat on the top and post must be at least 10 inches above ground level. Door One complete door of size 3’ x 7’ with Hinges, door lock and handle. Window Two side sliding glass window of size 3’ x 3’ along with and stainless steel grill with window canopy on the top of windows. Electric One tube light point, one fan point and one power plug andone normal plug point will be provided along with all necessary wiring and fittings completed and 20-watt LED light with holder and one mounted table fan to be provided. |