| 1 | S/F the following size/modules G.I box along with modular base and cover plate for modular switches in recess etc as reqd. |
| 2 | 1 or 2 modules (75mmX75mm) |
| 3 | 3 module (100mmX75mm) |
| 4 | 4 module (125mmX75mm) |
| 5 | 6 module (200mmX75mm) |
| 6 | 8 modules (125mmX125mm) |
| 7 | 12 modules (200mmX150mm) |
| 8 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed heavy class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B |
| 9 | Supplying and drawing the following size FRLS of PVC insulated copper conductor single core cable in the existing surface /recessed steel/ PVC conduit as reqd. |
| 10 | 1 x 1.5 sqmm |
| 11 | 2 x 2.5 sqmm |
| 12 | 2 x 4 sqmm |
| 13 | 2 x 6 sqmm |
| 14 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit as required.2 x 16 + 1 x 6 sqmm |
| 15 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor cable in the existingand earthing the point with 1.5 sqmm copper cable etc as reqd. at site Group B |
| 16 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
| 17 | 5/6 amps switch |
| 18 | 3 pin 5/6 amp socket outlet |
| 19 | 15/16 amps switch |
| 20 | 6 pin 15/16 amp socket outlet |
| 21 | Bell push |
| 22 | S/F of suitable size G.I box with modular plate and cover in front or surface in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB \"C\" curve including ,painting etc |
| 23 | Supplying and fixing of modular blanking plate on the existing modular plate and switch box excluding modular plate as reqd. |
| 24 | S/F of suitable size G.I box with modular plate and cover in front or surface in recess including providing and fixing 6 pin 5/6 & 15/16A modular socket outlet and 15/16 A modular switch, connection etc |
| 25 | S/F of brass batten/angle holder including connections etc as reqd |
| 26 | Supplying and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 27 | S/F of following sizes of heavy class PVC conduit/Batten along with all accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 28 | 25 mm |
| 29 | 20mm |
| 30 | Earthing with G.I pipe 4.5 metre long 40mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required. |
| 31 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required |
| 32 | Supplying and fixing 3 pin 5 amp ceiling rose on the existing junction box/wooden block including connection etc as reqd. |
| 33 | Supplying and fixing of call bell/buzzer suitable for single phase 230 volt complete as required. |
| 34 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way double door |
| 35 | 12 way double door |
| 36 | 8 way double door |
| 37 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 38 | Supplying and fixing following 63 amp, double pole, 240 volts, DP MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 39 | Supply, installation, testing and commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush less Direct Currnet ( BLDC) Motor, class of insulation: B3 nos blades, 30 cm long down rod, 2 nos canopies, shackles kit, safety rope, copper winidng , Power factor, not less than 0.9 service value ( CM/M/W) minimum 6.00 , Air delivery minimum 219 Cum/min 350 RPM ( tolerance as per IS: 374-2019) , THD less than 10% remote of electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C ( max) insulation resistance more than 2 mega ohm, suitable for 230 volt 50 HZ single phase 415 volt AC supply , earthing etc complete as reqd. |
| 40 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundincluding excavation, sand cushioning, protective covering andrefilling the trench etc as required. |
| 41 | Upto 35 sq. mm |
| 42 | Supply, Installation, testing and commissioning of pre-wired, single box fitting with one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 1xT-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm |
| 43 | Supply, Installation, testing and commissioning of pre-wired, wall mounted fancy white light, suitable for installation of LED bulb, 220-240 V, 50 Hzcomplete i/c all accessories but without bulb etc. including connection, etc. complete as required. Make Philips, Cat No. Cat No.Comet wall fancy light B22 or equivalent model of Thorn/Trilux |
| 44 | Wall light |
| 45 | Supply, Installation, testing and commissioning of 10 watt, LED bulkhead pressure die cast housing with IP65 protection and IK09 impact resistance suitable for surface and wall mounting applications., 220-240 V, 50 Hzcomplete i/c all accessories etc directly on surface including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. Make Philips, Model endura LED Bulkhead, Cat No.WT202W LED10S CW PSU S3 PC or equivalent model of Thorn/Trilux |
| 46 | Supplying , fixing of one number XLPE insulatedand PVC sheathedaluminium armoured conductorpower cable confirming to1.1 KV grade of following size direct in ground including excavation, sand cushioning , protective covering and refilling the same etc as reqd. |
| 47 | 4 x 16 sqmm |