| 1 | M & L for Cleaning/clearing of sewage line (including manholes except 1st manhole) 100mm to 350mm bore of any description under ground any depth, removing any type of blockage including desilting,descaling and de-chocking from drainwith combined high pressure water jetting cum suction (vacuum) type machine mounted on LMV/HMV having facility of high pressure vacuum including provision of hydraulic application through high pressure thermoplastic fiber based water jetting hose and through conical round shaped nozzle pipe and flushing after cleaning including clearing of manhole, sludge water shall be disposed of directed including taking of manhole cover and re-fixing the same after cleaning complete all as specified and directed. |
| 2 | M & L for Dewatering/Desludging & cleaning of manholeof any depth, any size, taking out water mixed with sludge and solid sludge including any foreign materials such as stones, tree hedges etc, removing and depositing sludge at a distance not less than 20 meter in a ditch including necessary excavation of pits and covering with earth & spraying unslaked lime on the covered ditch as well as around the manholes to make hygienic including necessary flushing of manholes with water after desludging complete all as specified and directed. |
| 3 | Taking out/Pumping out contaminated sewage water from septic tank/soakage well including inlet/outlet chamber after plugging incoming sewage line through combined high pressure water jetting cum suction (vaccum) type machine mounted on HCV Honey succer vehicle of capacity not less than 6000 ltrs each and facility of high pressure vaccum and removing off the same in the pit to a placet all as directed by Engineer-n-Charge. Note;One lorry unit will be considered for full load of 6000ltrs irrespective of taking out complete all as specified and directed. |
| 4 | M & L for Desludging the solid sludge from septic tank, soakage well including inlet/outlet chamber, removing out all scum, silt reduce sludge (both organic/inorganic nature) after plugging the incoming sewage line through combined high pressure water jetting cum suction (vacuum) type machine mounted on LMV/HMV and facility of high pressure vacuum and removing and dumping off the same in the tank to a place out side cantonment at the place marked for the purpose by local municipality or area controlling authority complete all as specified and directed. |
| 5 | M & L for Cleaning of soil waste pipe (cast iron/PVC/SGSW/DWCP )150/200mm borelaid in groundany slope or gradient and depth 3 mtr by roding taking out all residue from the lines/manholes including water and depositing at a distance not less than 20 mtr in ditch finally covering the ditch with earth and spraying unslacked lime on the covered ditch as well as around the manholes to make hygienic including excavation of ditch testing of line by flushing water after cleaning etc complete all as specified and directed. |
| 6 | M & L forCleaning/clearing of IWC/ EWC, gully trap /floor trap including CI pipe / PVC pipe upto first manholeby roding, taking out all residue including waste and testing by pouring water after cleaning etc complete all as specified and directed by Engr-in-Charge. (Note: Cleaning of PVC/CI pipe from first floor / ground floor embedded in floor or fixed to wall included in this item) complete all as specified and directed. |
| 7 | M & L for Cast iron oval access covers / inspection cover with bolts rubber gasket to make it water tight for 75mm/100mm bore CI fittings including taking out broken/ unserviceable cover with bolts etc and removing from site complete all as specified and directed. |
| 8 | Taking down chowkats or framesexceeding n.exc. 1.5 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed. |
| 9 | Taking downshutters of any description exc 1.00 Sqm and not exc 2.00 Sqm each complete all as specified and directed. |
| 10 | Taking down chowkats or framesexceeding 1.5 Sqm and n.exc 4.00 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed. |
| 11 | Supply and fix for PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube complete all as specified and as directed. |
| 12 | Supply and fix for factory made PVC door shutter 30mm thick (style) consisting of frame made out MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheets of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement complete all as specified and as directed. |
| 13 | S & F Aluminum anodized barrel tower bolt extruded section 150mm long complete all as specified and directed. |
| 14 | S & F in Aluminum anodized handles fabricated type of 150mm long complete all as specified and directed. |
| 15 | Excavation in trenches in any type of soil not exceeding 1.5m wide and not exceeding 1.5m wide for foundation etc or for shaft, wells, cesspits, manhole, pair house etc not exceeding 10 Sqm on plan and not exceeding 1.5 m depth and getting out in any type of soil complete all as specified and directed. |
| 16 | Returning filling in including, spreading, leveling watering and well ramming in layer not exceeding 25cm in each layer complete all as specified and directed. |
| 17 | Removing excavated material not exceeding 50 M and depositing where directed at level not exceeding 1.5m above the starting pointing complete all as specified and directed. |
| 18 | M & L for Plain cement concrete 1:4:8 as in foundation type D-2 (using 40mm graded crushed stone aggregate) as in fdn filling or mass concrete complete all as specified and directed. |
| 19 | M & L for Plain cement concrete 1:2:4 type B-1( using 20mm graded aggregate) as in benching, coping including watering slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed. |
| 20 | Demolition of brick work or stone masonry, built in CM including all quoins, arches, pillars etc. but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and directed. |
| 21 | M & L for Brick work with sub class B (old size) brick straight or curved on plan exc 6 mmean radius in CM 1:4 complete all as specified and directed. |
| 22 | All as item no 21 above but except bricks complete all as specified and directed. |
| 23 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for reinforcement cut as required to facilitate demolition, complete all as specified and directed |
| 24 | M & L for TMT mild steel bars 10MMdia and over cut to length bent to shape required including cranking bending spirally for hoping for columns, hooking ends and binding with and including mild steel wire annealed 0.9 mm dia or securing with clips complete all as specified and directed. |
| 25 | M & L for Mild Steel TMT bars 6 to 8 mm dia and over in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia, completeall as specified and directed. |
| 26 | M & L for RCC 1:1.5:3 for septic tanks slabs complete all as specified and directed. |
| 27 | M & L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick complete all as specified and directed. |
| 28 | M & L for Precast cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in manhole/drain slab cover all as specified and set in CM 1:4 complete all as specified and directed. |
| 29 | Taking down cement plaster on brick or stone wall etc including racking out joints, hacking for key scrubbing down with water etc to receive new plaster etc. complete all as specified and directed. |
| 30 | M & L for Rendering 15mm thick cement plaster in CM 1:4 on faces of brick work with or concrete WPC finished even and smooth without using extra cement complete all as specified and directed. ( WPC shall be measured and paid separately. ) |
| 31 | Supply only liquidwater proofing compound complete all as specified and directed. |
| 32 | Demolition and breaking up 150mm dia drain pipes (Salt glazed ware, AC or reinforced concrete ) and set in cement mortar all as spd and directed by Engr in Charge. |
| 33 | Demolition and breaking up 200 mm dia drain pipes (Salt glazed ware, AC or reinforced concrete ) and set in cement mortar all as spd and directed by Engr in Charge. |
| 34 | M & L for Concrete bed to drain pipes laid in trenches including packing under and haunching against the sides of pipes aftaer they are laid and tested in cement concrete 1:4:8 type D-2, using 40mm graded crushed stone aggregate for 150mm bore pipe, complete all as specified and directed. |
| 35 | M & L for Concrete bed to drain pipes laid in trenches including packing under and haunching against the sides of pipes aftaer they are laid and tested in cement concrete 1:4:8 type D-2, using 40mm graded crushed stone aggregate for 200mm bore pipe,complete all as specified and directed. |
| 36 | M & L for Salt -Glazed stoneware drain pipes 150 mm dia laind in trenches and jointed complete all as spd and directed |
| 37 | M&L for 200mm bore dia reinforced cement concrete pipes, class NP-2, laid and jointed complete with collars, complete all as specified and directed. |
| 38 | M & L for 200mm Bore / inner dia double wall, corrugated HDPE Pipe (SNB) (ISI Marked) with integral socket & necessary fitting jointing as directed & laid in trenches complete all as specified and directed |
| 39 | M & L for 150mm Bore / inner dia double wall, corrugated HDPE Pipe (SNB) (ISI Marked) with integral socket & necessary fitting jointing as directed & laid in trenches complete all as specified and directed |
| 40 | Cutting into existing manhole for connecting new drains and making good to pipes and rendering cutting out existing benching for and forming branching for and forming branch channel (1/2 round or ¼ section ) in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate smooth finished and reforming benching as specified and directed for 150mm dia of pipe complete all as specified and directed. |
| 41 | M & L for Cutting into existing manhole for connecting new drains and making good to pipes and rendering cutting out existing benching for and forming branching for and forming branch channel (1/2 round or ¼ section ) in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate smooth finished and reforming benching as specified and directed for 225mm dia of pipe complete all as specified and directed. |
| 42 | S & F in Vitreous china squatting pan “Orrisa” pattern of size 580mm “White” with \"P\" or \"S\" Trapfront or back inlet and foot rests, any pattern (excluding flushing cistern and flush pipe), connection to trap andto flushing pipe anti- syphonage pipe etc complete making good complete all as specified and directed. |
| 43 | S & F Vitreous china wash down closet pan (Pedestal pattern) white with ‘S’&\"P\"trap plastic seat cover white including connection to out going pipe & to flushing pipe, anti syphonage pipeetc complete all as specified and directed. (including making good to floor and fixing in repairs) |
| 44 | S & F in repairs, PVC valve less symphonic action type, flushing cistern, low level, white of capacity 10 ltrs with inlet , ball valve, float and and fixing arrangement complete all as specified and as directed. |
| 45 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for like pcc floor, bdrain pipe bed, hard standing etc complete all as specified and directed. |
| 46 | M & L 75mm thick PCC1:3:6Type B2 ( 40 mm graded aggregsate) as in subbase and pavings etc complete all as specified and directed. |
| 47 | M & L for 20mm thick screed screed bedding in cement mortar 1:6 as in sub base complete all as specified and directed. |
| 48 | M & LChequered cementconcrete tiles of size 30cm x 30cm x 20 to 22 mm thickglossy finish colouredand pattern in patches in floor with set & jointed in neat cement slurry and pointed in coloured cement to match the tiles laid over with grey cement and no pigment complete all as specified and directed. |
| 49 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as spd and directed |
| 50 | M & L for Glazed ceramic colored tiles 600mmx300mmx 6 to 7mm thick/450mm x300 mm x 7mm,as in patches invertical surfaces such as dado, skirting, wall etcset& jointed in neat cement slurry and pointed with coloured cement to match with tiles in over and including 10mm thick cement plaster in cement mortar 1:4. complete all as specified and directed. |
| 51 | S&FNon-skid ceramic colouredtiles 7 to 8mm thick area of each tile exceeding 0.11sqm but n exc 0.18 Sqmin floors etc set and jointed inneat cement slurry and pointed in white or coloured cement to match over 15 mm thickscreed bed or beddding layer of CM 1:6 including complete all as spd and directed. |
| 52 | Dismantling cast-iron/PVC pipes including fittings taking out of trenches or walls as required dia of pipe upto 100mm complete all as specified and directed. |
| 53 | M & L for 100mm dia Cast iron pipes with flanged ends, centrifugally cast, class A, in any length laid in trenches complete all as specified and directed. |
| 54 | M & L for 80mm dia Cast iron pipes with flanged ends, centrifugally cast, class A, in any length laid in trenches complete all as specified and directed. |
| 55 | M & L for upto 150mm bore CI Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \"Y\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete all as specified and directed. |
| 56 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls for 110mm bore complete all as specified and directed. |
| 57 | S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls for 75mm bore complete all as specified and directed. |
| 58 | S&F PVC (SWR) bends of 110mm bore complete all as specified and directed. |
| 59 | S&F PVC (SWR) bends of 75 mm bore complete all as specified and directed. |
| 60 | S&F PVC (SWR) Branch Piece double equal or unequal of 110mm bore complete all as specified and directed. |
| 61 | S&F PVC (SWR) Branch Piece double equal or unequal of 75 mm bore complete all as specified and directed. |
| 62 | S&F in repair stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays incl bolt and nuts securing ends of stays to wall or roof of 75mm bore complete all as specified and directed. . |
| 63 | S&F in repair stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays incl bolt and nuts securing ends of stays to wall or roof of100mm bore complete all as specified and directed. |
| 64 | S&F in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed. |
| 65 | Provided M & L for cleaning of all types ofblockage of Nahni traps/floor traps/bottle traps, blockages of WC\"s, rain water pipes and similar works complete all as specified and directed. Note :- 1. Labour shall be provided by the contractor on daily basis from 9:00 AM to 5:00 PM incl all Tools and Plants. Each labour shall intertain complaints everyday in working hours.2.The supervisor of Contactor shall take all complaints from the Complaint Cell and do the all on same day.3.Futhermore, the feedback shall be given by the contractor/supervisor to concened JE from all aspect. |