| 1 | Supply and fix in replacement CPVC pipe of size 75 mm inner dia in trenches high pressure CPVC pipes shedule40pipes and plain CPVC shedule80fittings includingall necessay fittings, like Elbow, Tee, Socket , Reducer, bushings , step over bends ,end caps, End plugs, etcand with CPVC solvents cement including taking down old unserviceble GI pipes pipes complete all as specified and directed by Engineer in charge .Make: Supreme/Eurotech /Astral/SFMC |
| 2 | Supply and fix in replacement CPVC pipe of size 50 mminner dia in trenches high pressure CPVC pipes SDR-11 & plain CPVC SDR 11 fittings includingall necessay fittings, like Elbow, Tee, Socket , Reducer, bushings , step over bends ,end caps, End plugs, etcand with CPVC solvents cementincluding taking down old unserviceble pipes complete all as specified and directed by Engineer in charge .Make: Supreme/Eurotech /Astral/SFMC |
| 3 | Supply and fix in replacement CPVC pipe of size 25 mminner diain trenches high pressure CPVC pipes SDR-13.5 & plain CPVC SDR 11 fittings includingall necessay fittings, like Elbow, Tee, Socket , Reducer, bushings , step over bends ,end caps, End plugs, etcand with CPVC solvents cement including taking down old unserviceble pipes complete all as specified and directed by Engineer in charge .Make: Supreme/Eurotech /Astral/SFMC |
| 4 | Excavation in trenches not exe. 1.5 M in depth and not exe 1.5 M in width including getting out for laying pipes etc including forming bottom surface to required level in soft/Dis integrated rocksoil complete all as specified and directed by Engineer in charge |
| 5 | Returning, refilling including spreading levelling watering and well ramming in layers not exce. 25 cm thick complete all as specified and directed by Engineer in charge |
| 6 | Removing the surplus soil to a distance not exe. 50 M and depositingwheredirected at a level not exe. 1.5 M from the starting poing complete all as specified and directed by Engineer in charge . |
| 7 | M & L for CPVC Ball Valve of size 50 mm dia suitable for CPVC pipe incl necessary fittings and taking down old unserviceble vall valvecomplete all specified and directed. Make: Supreme/Eurotech /Astral/SFMC |
| 8 | M & L for CPVC Ball Valve of size 40 mm dia suitable for CPVC pipe incl necessary fittings and taking down old unserviceble vall valvecomplete all specified and directed. Make: Supreme/Eurotech /Astral/SFMC |
| 9 | M & L for CPVC Ball Valve of size 25 mm dia suitable for CPVC pipe incl necessary fittings and taking down old unserviceble vall valvecomplete all specified and directed. Make: Supreme/Eurotech /Astral/SFMC |
| 10 | Supply and fix Gun metal Gate / Globe valve with iron wheel head, screwed both ends suitable for fixing with CPVC pipe of outer dia 50 mm and taking down old unsrviceble valvescomplete all as specified and as directed by the Engineer-in-charge. |
| 11 | Supply and fix Gun metal Gate / Globe valve with iron wheel head, screwed both ends suitable for fixing with CPVC pipe of outer dia 40 mm and taking down old unsrviceble valvescomplete all as specified and as directed by the Engineer-in-charge. |
| 12 | Supply and fix Gun metal Gate / Globe valve with iron wheel head, screwed both ends suitable for fixing with CPVC pipe of outer dia 25 mm and taking down old unsrviceble valvescomplete all as specified and as directed by the Engineer-in-charge. |
| 13 | M & L for seven stage cleaning and sterlization of inside UG sump reservoir / OHT of following capacitythrough bacterioligical treatment by using TERBAC GS, TERBAC-G-65 and ULTRA VOILET Ray, Make : Rays cleantech or equivalentProcess of seven stager are as under :-1. First stage is to draing out the water by using exist valve or high capacity dewatering system.2.Second stage is cleaning all the algae formation inside the tank by using TERBAC G10a laboratory tested branded chemical of the company and scrubbing the walls of the tanks.3. Third stage is fresh water cleaning by high speed jet pump.4. Fourth stage and first bacteria screening is decertification by using TERBAC-G5 a Govt Laboratory certified brannded halogen compound.5. Fifth stage is cleaning the floor of water tank by industrial vaccum cleaner.6. Sixth stage is the secord bacteria screening and sterilizing method by using ultra voilet ray within the tank and kills all suspended bacteria.7. Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified, branded strong oxidizing agent TERBAC-G65 |
| 14 | Note : 1- Company will submit govermnet laboratory test certificate of TERBAC-G5, TERBAC-G65, Fix the sticker mentioning the date of cleaning and name of site and also provide certificate confirming the completion of steriliztion of water tanks metnioning the name of station and date of cleaning. 2- Quoted rate shall deem to be inclusive of cost of scaffolding and disposal of sludge/scale/sediments upto a distance of n.exc 50m from work site as directed)3: contractor will not allow more than one day to do work inside each OHT to prevent interruption of water supply to users4 : all required safety equipments (gumboot,helmets safety belts,safety googles ,torch light etc )and necessary insurance for sefety of working staff to execute the work is responsibility of contractor |
| 15 | Cleaning ofSump of Capacity 250000 GLN ( NEW NWC ) Note : Rate are include cost of removing of sludges muds deposited inside the tankto a distance not exe. 50 M and depositingwheredirected at a level not exe. 1.5 M from the starting poing complete all as specified |
| 16 | Cleaning of UG Tank of CapacityCapacity 1,00,000 GLN ( At Main Pump House and NEW NWC ) |
| 17 | Cleaning of UG Tank of Capacity of Capacity 50,000 GLN ( At Main Pump House, Offs MD Accn Area & Sailer Area) , |
| 18 | Cleaning of UG Tank of Capacity of Capacity 25,000 GLN ( Ward Mess Pump House ) |
| 19 | Cleaning of UG Tank of Capacity 15,000 GLN ( At DSCMD Accn ) |
| 20 | Cleaning of UG Tank of Capacity10,000 GLN ( Civ MD Accn ) |
| 21 | Cleaning of OHTof Capacity 50,000 GLN (Nousena Bagh ) |
| 22 | Cleaning of OHTof Capacity75,000 GLN ( Eklavya OH Tank ) |
| 23 | M&L for cross arm ,bracings,support,clamps and back plates fabricated from structural steel section including nuts, bolts,washer, welding ,drilling hole for bolts ,bending in any shape or size as indicated or directed and inclusive of one coat of aluminium primer,one under coat and one finishing coat of aluminium paint for for repair /repalcement of portion of existing ladderat OHT as per existing specification / frame /cover for valve chamber etc complete all as specified and as directed |
| 24 | M & L forDismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m |
| 25 | M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick burried directly in gorund (earth pit not less than 2.25 Mtr normal ground level),and top edge of earth plate not less than 1.5 mtr below normal ground level,using galvanised iron strip 25×4mm as earthing lead with bolts, nuts & check nuts, and washers of galvanised iron protection pipe light grade of 40 mm dia and watering pipe medium grade of 20 mm dia and filled with alternate layer of charcoal and common salt, watering funnel with wire mesh, earth pit chamber and cover CI frame PCC 1:3:6 type C-2 all as shown in electrical plate No-3 of SSR part-I of 2009 connected to earthing test point all as specified and indicated including all earth work excavation, returning filling and disposal of surplus soil and testing on completion. |
| 26 | Supply, Fix and testing Smart Digital 5-levels % Indicator stage type with mechanism to detect & display the Water level in an Underground/ Overhead tank., fixed on Wall / OHT with necessary PVC Corrosion free enclosure, corrosion & maintenance free Magnetic sensors. Buzzer alarm sounds on Low & High Levels. Including necessary fittings on sensing the water level from OHT of Height up to 21 MTrs /UG Sump of Depth at 6.0Mtrs completeMake: Sinetrac |
| 27 | S & F 3 core PVC insulated and sheated , un armoured multi stranded copper conductor cable of size 4.0 Sq mm complete all as specified and directed |
| 28 | Supply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall for protection of underground calbes of size 40 mm outer diawith all fittings. laid in trenches / road/ nallah or fixed along wall. poles or laid under floor (including cutting floor/Road and making good to match with existing adjoining surface etc for cable protection all as specified(excavation and earth work shall be measured and paid separately) |
| 29 | M & L forTaking out vertical submersible pump motor set from existing borewell of capacity from 2.0 HP to7.5 HP capacity , dismantling pump complete after disconnecting all electrical connections and repair/overhauling including replacement of followingworn outparts as per sample Note : (i) Spares required for replacement shall be measured and paid as \"Supply only\" under respective items.(ii) Reassembling, lowering in sewage sump to its original place , testing and transport will be included in quoted rate. |
| 30 | Supply only Gun metal bush of capacity , complete all as specified & directed. |
| 31 | Supply only impeller, complete all as specified and directed. |
| 32 | Supply only impeller key, complete all as specified and directed. |
| 33 | Supply onlyneck ring (bronze), complete all as specified and directed. |
| 34 | Supply onlyguide ring, complete all as specified and directed. |
| 35 | Supply onlylock bolt for impeller , complete all as specified and directed. |
| 36 | Supply only shaft sleeve, complete all as specified and directed. |
| 37 | Supply only shaft coupling (screwed), complete all as specified and directed. |
| 38 | Supply only couplingpin & bush, complete all as specified and directed. |
| 39 | Supply onlyball bearing, complete all as specified and directed. |
| 40 | Supply only lock bolt for shaft coupling, complete all as specified and directed. |
| 41 | All as per item No. 21.11but top shaft, complete all as specified and directed. |
| 42 | M & L for replacement of foot valve brass 50 MM dia Pipe complete including taking tp suction lines from UG sump of depth max up to5.0 Mtrs and lowering after replacemnt of foot valve complete all as specified. |
| 43 | M & L for replacement of foot valve brass 80 MM dia Pipe complete including taking tp suction lines from UP sump of depth max up to5.0 Mtrs and lowering after replacemnt of foot valve complete all as specified. |
| 44 | M & L for replacement of foot valve brass 100 MM dia Pipe complete including taking tp suction lines from UP sump of depth max up to5.0 Mtrs and lowering after replacemnt of foot valve complete all as specified. |
| 45 | Material and labour for development of tube well byat the site including dismatling existing GI/CPVC/HDPE bore well pipes up to 80 Mtrs depthincluding taking up submersible pumps and flushing of bore well with air compressor of capacity 250PSI/1000 Cum and related accessories at leat 3.0 hours till water discharge is free from sand and potable water and to achieve maximum discharge capacity includingnecessary development complete and lowering submersible pump with GI/CPVC/HDPE borewell pipes complete including testing of borewell all as specified and directed.(Note: (i) Unit rate quoted under this items shall deemed to be inclusive of transportation of tools and equipments as required to the site of work and removing the same after completion of work(ii) Verticality test of the tube well structure shall be carried out and the cost of the same shall be deemed to be included in unit quoted rate) |
| 46 | M & L for Testing of water samples from Sourceinside the INS MAndovi from OHT/Sump/Bore Wells/Any service Tanks and testing in Govt Lab / Govt Approved PVT Labs for Bacterial and chemical testing of water sample to find out the Total Coliforms,E. coli (Faecal Coliforms) , PH , Nitrates: ,Nitrates and Turbiditycomplete includingtaking the samples in every QE /As and when required as directed by Engineer in Charge.Note: The M & L for collection ofsamples including NEw Container as per LAb standards, Transportaion Cost up to Labis included in Unit rate. |
| 47 | Supply, fabricating, installation, in replacementself illumnatedacrylic LED Sig Board factory made withfixed on wall /iron frame as directedLetter Length30 cm max up to 40 cm Letter Thickness5 cm max up to6 cmCustomized Design of letters back-lit signage including embedding the signage baord firmly with the wall/ MS Angle frame/as per approved Art work and nomenclature as given below :- Note: Nomenclatureof sign board include letters/Logos etc complete as directed. |
| 48 | Box with frame :- 25 x 25 mm square pipe (18 G) frame with cross supports @ spacing not exceeding 1.0 m on the box length including 20 mm x 20 mm MS Square pipe (18 G) stifferenrs duly white enamel painted in 2 coats over a coat of zinc oxide iron primer, depth of box should not be less than 165 mm,Side, Top, Back and bottom Panels :- Made out of 24 gauge chemically treated GI Sheets duly precoated / powder coated with white MATT finish coating on both inner and outer surface. Top panel to have 24 guage precoated drip cap (fixed with pop rivet or machine moulded to shape) of 25 mm on front and side to prevent damages due to rain etc.The bottom panel should be provided with access door fixed with ss screws and suitable housing for LED drivers.LED Module :-LED 12V Module beam angle >=150 degrees with IP rating >= 64, 0.72 W/70 Lumens per module of 3 LEDs with 7000 to 8000 K colour temperature, Make : Tridonic/ Osram / Cree / GELED power supply :-Input 230 V AC, power supply should be CPCC (Constant power constant current) of 30W/60W/120 W each.Graphics :-Graphics shall be computer plotter cut with translucent cast vinyl matching the colour specification of the installation. |
| 49 | M & L for servicing of filtration plant at water supply installations including removing the existing gravels in sand filter , complete painting of filtration plant including replacing unserviceble nuts , bolts of cover plate complete : Location Main Pump House , Swimming Pool Note: Work Shall be done through the OEM /auth service partner of OEM (Ion Exchange) Sand/grave/pubblesrequired for replacement is measured and paid seperately under respective items. |
| 50 | Supply and fill in replacementpebblessize 1\" /1.5\"mm in sand filter including getting out from the filter all as per specified and directed by Engr-in-charge. |
| 51 | Supply and fill in replacementpebblessize 1\" - 3/4\"mm in sand filter including getting out from the filter all as per specified and directed by Engr-in-charge. |
| 52 | Supply and fill in replacementpebblessize 3/4 \" 1/2 \"mm in sand filter including getting out from the filter all as per specified and directed by Engr-in-charge. |
| 53 | Supply and fill in replacement coresesiliexsize 1/2 \" 1/4 \"mm in sand filter including getting out from the filter all as per specified and directed by Engr-in-charge. |
| 54 | Supply and fill in replacementcoresesiliexsize 1/4 \" 1/10 \"mm in sand filter including getting out from the filter all as per specified and directed by Engr-in-charge. |
| 55 | Supply and fill in replacementgraded sand in sand filter including getting out from the filter all as per specified and directed by Engr-in-charge. |
| 56 | Supply and fill in replacementof Activated Carbon including getting out from the filter all as per specified and directed by Engr-in-charge. |
| 57 | M& L for surface excavation at water supplyinstallations , not exceeding 30 cm deep and averaging 15 cm deep and getting out soft / loose soilremovingshrubs, small trees height up to 1.0 Mtrs , removing the grass from route as directed , Note : (i) Rate includesremoving all waste material and grass not excceding 250 Mtrs distance from installation ,depositing where directed at a level not exceeding 1.5 Mtrs above the starting pointand cleaning of yard , Complete all as specified and directed by EIC.(ii) Repeated cleaning in each installation shall be measured and paid seperately with time interval of minimum 2 months. |
| 58 | M & L for laying of weed control mat sorrounding area of Over Head Tank /UG Sump , insid etheWater supply Installations of Sizethicknessless than100 GSM ans Size1.0/1.2 widthX 100 Mtrs length of roll laid in level surface with 7 inch (18 cm) High Quality PVC Nails forfirm hold for Weed Mat at earth surfaces in regular intervals ( In Between5 Mtrs) complete alla s specified and as directed. |
| 59 | Supply and fixfire retardant insulated syntheticmatforLT , 1100 Voltof 2.0 mm thick+/- 10% conforming to IS , tested for breakdown strength, ageing properties, insulation resistance, effect of acid,Alkaline, Diesel & transformer oil ,leakage current test,fire testetchaving the width of 1000mm +/-20mm complete as required sutable and using adhasive and alied chemical and scaling of all part s of all joints and border ends and fixingtape making good as paste near LT panel boards complete all as specified and as directed.Make: Vardhaman/Jyothi/Cease fire/Qquivalent |
| 60 | S & F junction box made from SMC/FRP sheet ready made of size300X 200X105mm with aluminium bus bar of100Amp capacity for RYB andhalf for neutral made in suitablesize fixed inside the junction box with necessary supporting insulators fixed on hylem sheet ,MS sheet steel fixed inside the bottom portion of box to connect the cable gland complete , entire assemblyfixed to pole /Wall with MS clamp 25 X 5 mm and nuts & bolts, or inside the Copping of pole /Post top including MCB SP 6 Amp 10 KA 240 V - 1 No, with necessary sizecopper lugs for connecting cables from junction box to fittings complete all as directed by Engineer-in-Charge . Make: Sintex (right hinged)Hensal |
| 61 | S & F LT feeder piller box 2.0 mm thick in doortype, CPRI approvedwith63Ampcopper bus bar for RYB and neutral with necessary control wiringconsisting of following :- Incomming Main MCCB 40 Amp,4 pole16KA - 01 Nos Multi function meter for V-A-F -01 NosIndicating Lamp for RYB- 01 Set Out Going MCB TPN - 16 Amp - 02 NosMPCB15-20 Amp with O/L , SC and Single phase Preventer- TPN16 Amp 10 KA- 02 Nos Fully automaticStarter for10 HP Pump Motor Cat No SS96255POVO Make L&T now L& K- 02 Nos Curent Transformer 20/ 25- 5Amp - 06 Nos Push Buttonfor Start/Stop- 04 NosLED Indicating LampON/Off /Trip - 06 Nos MCB 6 Amp - 02 Nos Note: (i) Panel Shall be floor Mounted Inside the Pump House.(ii) Minor Variation in Range of Starter /MPCB CT shall be selected as pe the Make approved. |
| 62 | S & F LT feeder piller box 3.15 mm thick Out doortype, CPRI approvedwith40Ampcopper bus bar for RYB and neutral with necessary control wiringconsisting of following :- Incomming Main MCCB 32 Amp,4 pole16KA - 01 NosMulti function meter for V-A-F -01 NosIndicating Lamp for RYB- 01 Set Out Going MCB TPN - 16 Amp - 01 NosMPCB15-20 Amp with O/L , SC and Single phase Preventer- TPN16 Amp 10 KA- 01 Nos Fully automaticStarter for10 HP Submersible Pump Motor Cat pt No -CS94091SOAO Make L& T now L&K - 01 Nos Curent Transformer 20/ 25- 5Amp - 06 Nos Push Buttonfor Start/Stop- 04 Nos LED Indicating LampON/Off /Trip - 06 Nos MCB 6 Amp - 02 Nos Note: (i) Panel Shall be floor Mounted outside(ii) Minor Variation in Range of Starter /MPCB CT shall be selected as pe the Make approved. |
| 63 | S & F LT feeder piller box 2 mm thick In doortype, CPRI approvedwith40Ampcopper bus bar for RYB and neutral with necessary control wiringconsisting of following :- Incomming Main MCCB 32 Amp,4 pole16KA - 01 Nos Multi function meter for V-A-F -01 NosIndicating Lamp for RYB- 01 Set Out Going MCB TPN - 16 Amp - 01 NosMPCB15-20 Amp with O/L , SC and Single phase Preventer- TPN16 Amp 10 KA- 01 Nos Fully automaticStarter for 5/ 7.5 HP Submersible Pump Motor Cat Ot No-CS94091SOVO Make L&T now L& K- 01 Nos Curent Transformer 20/ 25- 5Amp - 06 Nos Push Buttonfor Start/Stop- 04 Nos LED Indicating LampON/Off /Trip - 06 Nos MCB 6 Amp - 02 Nos Note: (i) Panel Shall be floor Mounted inside Pump room (ii) Minor Variation in Range of Starter /MPCB CT shall be selected as pe the Make approved. |
| 64 | Supply and fix in replacement HDPEpipe OF pressure rating 6 KGF/ SQ CMof size 50mm inner dia in bore wellincludingall necessay fittings, like Elbow, Tee, Socket , Reducer, bushings , step over bends ,end caps, End plugs, etcand with including taking upold unserviceble GI pipes pipes complete all as specified and directed by Engineer in charge .Make: Supreme/Eurotech /Astral/SFMC |
| 65 | S&F PVC insulated, PVC sheathed , stranded copper conductor as inflat submersible water proof cable of size 16 sqmm 3 core1100 volts gradeincl taking down old one complete as specified and directed. |
| 66 | S&F PVC insulated, PVC sheathed , stranded copper conductor as inflat submersible water proof cable of size 10 sqmm 3 core1100 volts gradeincl taking down old one complete as specified and directed. |
| 67 | S&F PVC insulated, PVC sheathed , stranded copper conductor as inflat submersible water proof cable of size 6 sqmm 3 core1100 volts gradeincl taking down old one complete as specified and directed. |
| 68 | M & L for painting of Incoming and outgoing pipes of OHT / Sumps with standard colour code for CI pipe of Sixe100/150 MM Dia complete all as specified. |
| 69 | M & L for MS Pipe of sise150 MM dia with Necessary Bend , Tee , weldeding as required at size including necessary fittings to join with existing GI/CI pipe lines complete all as specified and as directed. |
| 70 | M & L for MS Pipe of sise100 MM dia with Necessary Bend , Tee , weldeding as required at size including necessary fittings to join with existing GI/CI pipe lines complete all as specified and as directed. |
| 71 | M & L CIFittingfor Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. \"Y\" junction, double branch, cross (flange sockets or socket and spigot) collars, caps and plugs all complete all as specified and as directed.size up to 150 mm bore |
| 72 | S&F in replacementbutter fly valve in any positionof size150 MM dia includingrubber gasget, nut, bolts, washers including taking down unserviceablevalvecomplete all as specified and directed. |
| 73 | S&F in replacement NRVin any positionof size100 MM dia includingrubber gasget, nut, bolts, washers including taking down unserviceablevalvecomplete all as specified and directed. |
| 74 | Supply fixing in and replacement of unserviceableAutomatic pressure switchfor 1 HP to 2 HP booster pumpall as specified and as directed.. |
| 75 | supply and fixing in replacement ofsurge tank (booster tank) suitable for booster pump including taking out the old one all as specified and as directed.. |
| 76 | Supply and fixingin repalcement of manifolder /Connector asswembly for booster pump 5 way suitable for booster pump including taking out the old one all as specified and as directed. |
| 77 | Supply andFixing in repalcement of Non return valve 25 mm for booster pump complete all as specifed and as directed |
| 78 | Supply and fix in replacement of Pressure gauge 0-5 Kg /cm2 for booster pump complete all as specified and as directed |
| 79 | Supply and fix in replacement Motor of capacity0.75/1.0 HPfor booster pump complete all as specified and as directed |
| 80 | M & L for dismantling of existing damaged valve pit complete and costruction of new brick masonary valve pit chamber of size 600 x 600 x 600mm (internaldimension)including,PCC,brickwork and MS sheet cover 2.0 mm thick,MS angle iron frame size 25mm x 25mm x 6mm around of valve pit,locking arrangement withpainting all steel surfaces with two coats of sythetic enamel paint over a coat of red oxide primer complete. |
| 81 | M & L for dismantling of existing damaged valve pit complete and costruction of new brick masonary valve pit chamber of size 450x 450 x 450mm (internaldimension)including,PCC,brickwork and MS sheet cover 2.0 mm thick,MS angle iron frame size 25mm x 25mm x 6mm around of valve pit,locking arrangement withpainting all steel surfaces with two coats of sythetic enamel paint over a coat of red oxide primer complete. |
| 82 | Supply and fix in replacement panel mount digital voltmeter 0-500 Volt complete |
| 83 | Supply and fix in replacement panel mount digital Ammeter0-50 Ampcomplete |
| 84 | Supply and Fix in replacemnet LED type indicating lamp complete |
| 85 | Supply and Fix in replacemnet CT\"s50/ 5 Amp complete |
| 86 | Supply and Fix in replacemnet CT\"s 100/ 5 Amp complete |
| 87 | Note: An amount of Rs 48295.00 on account of Credit Schedule for Schedule A Part II shall be deducted from the total amount of BOQ to arrive at Contract Sum. |