| Sl. No. | Item Description |
| 1 | Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding fittings but includingswitches, ceiling roses, pendants, regulators, sockets, etc.and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed. |
| 2 | M&L for concealed point wiring with PVC insulated unsheathed multistranded FRLSH copper conductor in and including PVC conduitwith cable 1.5 Sqmm size 1100 volts grade conforming to IS:694 and terminate to flush box of required size suitable mounting modular switches and sockets/ sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top covers including single core multi stranded FRLS copper conductor 1.5 Sqmm PVC insulated cable as earth wire connected to earth and common earth dollydrawn in same concealed conduit for one light/fan/wall fan/exhaust fan/bellpoint controlled by one No, one way 5/6/10 Amp switch complete all as specified and as directed.Note: Cutting chases for concealed type point wiring including making good the same with plaster/putty and Modular boxes with cover plate/ sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top covers will be deemed to be included in quoted rate. |
| 3 | Allas per item serial No 2 here-in-before butfor One 3 pin 5/6/10 Amp switch socket outlet on independent board. |
| 4 | Allas per item serial No 2here-in-before butfor One 3 pin 5/6/10 Amp switch socket outlet on same board with other switches. |
| 5 | All as per item serial No 2 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cableand earthcontinuity wire with 2.5 Sqmm cable for 6 pin 15/20 Amp socket outlet on independent board. |
| 6 | M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathedFRLS cable, 1100 volts grade IS-694marked, with multistranded copper conductors and earthcontinuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly)laid/fixed with and including PVC Casing and Caping on walls/ceiling, and with sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top covers for one light/fan/exhaust fan/bell point controlled by one number one way 5 /6/10 Amp switch complete all as specified and as directed. |
| 7 | Allas per item serial No 6 here-in-before butfor One 3 pin 5/6/10 Amp switch socket outlet on independent board. |
| 8 | Allas per item serial No 6here-in-before butfor One 3 pin 5/6/10 Amp switch socket outlet on same board with other switches. |
| 9 | All as per item serial No 6 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cableand earthcontinuity wire with 2.5 Sqmm cable for 6 pin 15/20 Amp socket outlet on independent board. |
| 10 | S & F switch piano, flush type single pole one way 5/6 Amps 230/240 volt complete all as specified and as directed. |
| 11 | S&F socket outlet 3 pin, 2-in-1, 5/6 Amps, flush type240 volts complete all as specified and as directed |
| 12 | S & F switch piano, flush type single pole one way 15/16/20 Amps 230/240 volt complete all as specified and as directed. |
| 13 | S & F Socket outlet 2 in 1, 3 pin, 5/15 amps or 6/16 Amp, flush type, 240 volts complete all as specified and as directed. |
| 14 | S & F stepped type electronic fan regulator, flush type complete all as specified and as directed. |
| 15 | S&F in repairs, socket outlet 3 pin, 2-in-1, 5/6 Amps, flush type240 volts complete all as specified and as directed |
| 16 | S&F in repairs,stepped type electronic fan regulator, flush type complete all as specified and as directed. |
| 17 | S&F Modular switch 1 way 6A/10A, 1 module, single pole240 volts complete all as specified and as directed. |
| 18 | S&F Modular socket6/10 Amp, 2/3 pin combined2 module complete all as specified and as directed. |
| 19 | S&FModular switch 1 way 16/20 Amp, 1 module complete all as specified and directed. |
| 20 | S&FModular socket, 6/16 Amp or 10/20 Amp, 2/3 pin combined 2 module 240 volts, shuttered type complete all as specified and as directed. |
| 21 | S&F Modular stepped type electronic fan regulator 120W two module size, flush typecomplete all as specified and as directed. |
| 22 | S&F lamp holder, insulated, PVC / polycarbonate /bakelite body complete all as specified and as directed. |
| 23 | S & F ceiling rose surface bakelite, 65x50mm three terminal complete all as specified and as directed. |
| 24 | S&F in repairs, Modular switch 1 way 6/10 Amp, 1 module, single pole one way complete all as specified and as directed. |
| 25 | S&F in repairs, Modular switch 1 way 16/20 Amp, 1 module complete all as specified and directed. |
| 26 | S&F in repairs,Modular socket6/10 Amp, 2/3 pin combined2 module complete all as specified and as directed. |
| 27 | S&F in repairs,Modular socket, 6/16 Amp or 10/20 Amp, 2/3 pin combined 2 module 240 volts, shuttered type complete all as specified and as directed. |
| 28 | S&F in repairs, Modular stepped type electronic fan regulator 120W two module size, flush typecomplete all as specified and as directed. |
| 29 | S&F in repairs, Modular metal flush box 3 module complete all as specified and as directed. |
| 30 | S&F in repairs, Modular metal flush box 6 module complete all as specified and as directed. |
| 31 | S&F in repairs, Modular metal flush box 12 module complete all as specified and as directed. |
| 32 | S&F in repairs,white cover plate with frame 3 module complete all as specified and as directed. |
| 33 | S&F in repairs,white cover plate with frame 6 module complete all as specified and as directed. |
| 34 | S&F in repairs,white cover plate with frame 12 module complete all as specified and as directed. |
| 35 | S&F in repairs,galvanised iron sheet Box thickness not less than 1mm as in concealed wiring of any type and any size complete all as specified and as directed. |
| 36 | S&F in repairs, PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 200 mm x 150 mm and 50 mm deep in complete all as specified and as directed. |
| 37 | S&F in repairs, PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 175 mm x 100 mm and 50 mm deep in complete all as specified and as directed. |
| 38 | S&F integral LED 4ft luminaire of CRCA / extruded aluminium housing and PC diffuser (Diffuser-Non yellowing type). The luminaire should have a 20 Watt LED with colour consistency SDCM< 5,CRI> 80 and colour temperature - 4000 to 6500K, Luminaire shall be designed to emit at least 2400 nominal lumens at a system efficacy of at-least 120 lumen/watt, power consumption should not be more than 20W (+5%). the life of fixture (including Driver): 50000 burning Hrs.@ L70B50 Lumen maintenance @ design ambient temp 50 deg C. The electronic driver used shall have a power factor >0.95 and THD < 10% suitable for an operating voltage range of 150-270V AC current Ripple<5% internal surge protection should be minimum 4KV, electrical insulation class should be Class I &driver should be of class B serviceability. The luminaire should be at least IP20 & IK02 rated. The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have in house NABL accredited lab conduct LM79, type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for luminaire manufacturer along along with sample approval. The LED Luminaire & It\"s driver both should be BIS registered contractor shall submit the following reports before supply of material for approvals LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer type test certificate for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver including dismantling of old tube light fitting of any descriptioncomplete all as specified and as directed. |
| 39 | S&F in repairs Environmentally friendly, ultra modern, energy saving, Pressure die cast housing 10 W LED bulkhead with IP66 protection and IK09 impact resistance suitable for surface and wall mounting applications comprising of high brightness LEDs complete all as specified and as directed.Make:- Philips Model : WT202W LED10S CW PSU S3 PC/WT202W LED10S NW PSU S3 PC or Havells Model HEXAFT10WLED857SSYMBOPC or equivalent Model of make Crompton /Bajaj/Wipro. |
| 40 | S&F in repairs, Decorative wall light fixture made up of Polycarbonate suitable for lamp (B22) including suitable size LED Bulb(9W) etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.Make:- Havells Model CITY 1/CITY 3 Cat No LHDL02160099/LHDL06160099 or equivalent Model of make Philips/Crompton /Bajaj/Wipro. |
| 41 | S&F in repairs , LED luminaire 600 mm x 600 mm, 40 watts, 220 Volts, AC, recessed/surface, white/warm type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver andflexible copper conductor cable of suitable size complete all as specified and as directed. |
| 42 | S&F LED street light fitting of high-quality group control enabled integrated LED Bldg Security light with a minimum system lumen of min 4900 lm and system wattage not less than 35W with a nominal system efficacy of 140 lumen/watt. The LED used shall have CCT of 5700K, SDCM ≤ 5 and CRI≥70. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure die-cast aluminum, to withstand extreme environments. The spigot shall be part of “Single Piece Pressure Die-cast housing” & shall not be bolted to the luminaire housing to ensure robust design. The name of the brand should be embossed/engraved & should not be mentioned using sticker/screen printing. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. The luminaire LED shall have declared Lifetime of 50K hours@L70B50. The product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 & impact resistance shall be IK10. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 20 KV/10KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The Driver should be asphalt potted & should be a BIS approved driver. The driver shall have operating voltage of 120V to 270V, PF≥0.95 @ full load, THD≤10% @ full load. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547 & IEC 61000-3-2.The luminaire driver & it’s SPD shall be of the same make/manufacturer as that of LED luminaires.Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with Sample Approval. The LED Luminaire & it\"s driver both should be BIS registered. The contractor shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test report for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete including taking down old unserviceable light fittingcomplete all as specified and as directed. |
| 43 | S & F security lightbracket made out of GI pipe 32mm dia medium grade (bent to shape as directed ), 1.0 M long, fixed with MS flat iron clamps made out of 40 mm x 6 mmwith nuts, bolts, washers and other connected items of required size, suitable for steel tubular poles/wall and painting with one coat of aluminium paint over a coat of red oxide zinc chrome primer including taking down old bracket complete all as specified and as directed. |
| 44 | M&L for Sub main wiring with 2 runs of 4 sqmm, single core, FRLSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC concealed conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4 sqmm single core FRLSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and as directed. Note: (i) 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit altogether shall be measured as one unit.(ii) Cutting chases for concealed submain wiring for the above point and making good in cement mortar is deemed included in quoted rate. |
| 45 | M&L for Sub main wiring with 2 runs of 6 sqmm, single core, FRLSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC concealed conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6 sqmm single core FRLSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and as directed. Note: (i) 2 run of 6 Sqmm cable and 1 run of 6 Sqmm cable along with conduit altogether shall be measured as one unit.(ii) Cutting chases for concealed submain wiring for the above point and making good in cement mortar is deemed included in quoted rate. |
| 46 | S & F in repairs, Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp 240V complete all as specified and as directed. |
| 47 | Disconnecting all electric connection and taking down old DBs (any type of Vertical load line/TPN/ SPN DBs) and making good to the disturbed surfaces to match the existing surface complete all as specified and as directed.Note – Temporary connection for power supply shall be done by contractor. |
| 48 | Refixing only old serviceable MCB DB of any size at existing or any other location with proper fixing and PCC work and connecting with MCB complete all as specified and as directed. |
| 49 | S&F in repairs,MCCB3P, 125 Amps 415 V, Icu16 KA, thermal magnetic complete all as specified and as directed. |
| 50 | S & F in repairs, factory made, sheet steel distribution boards, TPN, 4 Way, double door, protection class IP-43 with min 100 Amp rating copper bus bar, provision for FP MCB as incomer and SP MCBs as outgoing complete and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and as directed . Make :- Legrand Cat No 5076 70 or L&K Cat No DETPE004DDS or equivalent. model in Siemens / Schneider/Havells |
| 51 | S & F in repairs, single pole & neutral DBs 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed.Make :- Legrand Cat No 5076 11 orL&K Cat No DESPN008DDS or equivalent model in Siemens / Schneider/Havells. |
| 52 | S & F in repairs, single pole & neutral DBs 12 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed.Make :- Legrand Cat No 5076 12 orL&K Cat No DESPN012DDS or equivalent model in Siemens / Schneider/Havells. |
| 53 | S&FMCB four pole40 to 63 Amps in accordance with IS/IEC 60898-1, 415 V, 50 Hz,10 kA,C-series rupturing capacity providing in DB complete all as specified and as directed.Make:- L&K Cat No :BB40400C to BB40630C, or Legrand Cat No 4087 00 to 4087 02 or equivalent model of make Siemens/Schnider/HagerABB/Havells |
| 54 | S&FMCBs, SPN 6 to 32 Amps, 10 KA,\"C\" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 55 | S&FMCBs, SPN 40 to 63 Amps, 10 KA,\"C\" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 56 | S&FMCBs, SP 6 to 32 Amps, 10 KA, \"C\" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 57 | S&FMCBs, SP 40 to 63 Amps, 10 KA, \"C\" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 58 | M & L for 40 mm bore GI pipe (Light grade) fixed with wall with maximum span of 4.0 meters suitable for hanging of ceiling fan of size 1200mm/1400mm sweep including necessary cutting hole in brick/stone wall and making good the same with PCC 1:2:4 type C1 (Using 20 mm graded crushed stone aggregate) as required complete all as specified and as directed. |
| 59 | Taking down fan of any type/make and size of AC ceiling fan, carefully from fan hook,and transportingto MES E/M store yard,and refixing on same location or other locationcomplete all as specified and as directed. Note:-Cost of repairing including replacement of spares if any will be measured and paiid seperatelyunder relevent items of this schedule. |
| 60 | Strip opening of ceiling fan1200 /1400 mm sweep, cleaning thoroughly bush & ball bearing by petrol, washing/cleaning fan blades with caustic soda thoroughly, provision of fresh greasing, replacement of worn out/defective unserviceable parts (wherever necessary) reassembling the same and testing the fan on full load to entire satisfaction of Engineer-in-Charge.Note:- (i) Replacement of defective/ unserviceable parts shall be measured and paid separately in respective items as supply only. |
| 61 | Strip opening, Cutting the existing copper winding of AC ceiling fan1200 mm//1400mm sweep and rewinding the armature (Rotor) with super enamelled copper wire of suitable size includingprovision of twisted twin core flexible wire upto 0.7 metres long size 24/0, 020 (ISI marked) all insulating materials including greasing, varnishing, heating and drying complete includingsatisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge.Note:- (i) Replacement of defective/ unserviceable parts shall be measured and paid separately in respective items as supply only. (ii) Ball bearing of size 6201/6202 suitable for ceiling fan deemed to be included in quoted rate. |
| 62 | Taking down exhaust fan/wall fan of size 200mm to 450mm sweep of any make and transporting from any locationto MES E/M store yard, and refixing on same location or other location carefully after repairing,washing by petrol ,greasing, replacement of worn out/defective unserviceable parts (wherever necessary) assembling the same includingprovisionof twisted twin core flexible wire upto 0.7 meterslong size 24/0, 020 (ISI marked) and testing the fan on full load to entire satisfaction of Engineer-in-Chargecomplete all as specified and as directed.Note:- Cutting the existing copper winding, rewinding, Replacement of defective/ unserviceable parts if required shall be measured and paid separately under respective items . |
| 63 | Cutting the existing copper winding of AC exhaust fan200mm to 300mm sweep and rewinding the armature (Rotor) with super enamelled copper wire of suitable size includingprovision of twisted twin core flexible wire upto 0.7 mtrs long size 24/0, 020 (ISI marked) all insulating materials including varnishing, heating and drying complete incl satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge. |
| 64 | Allas per item serial No 63 here-in-before butfor exhaust fan/pedestal fan/wall fan of size 380/400/450mm sweep complete all as specified and as directed. |
| 65 | Supply only condenser ISI marked 230/240/250 volts AC 2.5 Mfd suitable for ceiling fan.(Make : Usha/Asian/EPCOS/Universal). |
| 66 | Supply only condenser ISI marked 230/240/250 volts AC 3.15 Mfd suitable for ceiling fan.(Make : Usha/Asian/EPCOS/Universal). |
| 67 | Supply only plastic canopy upper & lower of any size and make of ceiling fan fixed with suitable size of screws complete all as specified and as directed. |
| 68 | Supply only down rod 15mm dia GI pipe heavy duty 45 cm long including machining/ threading/drilling hole of size suitable for nuts and bolts washer and split pin suitable for any size and make of fan complete all as specified and as directed. |
| 69 | Supply only rubber reels including shackle clamp, bolts, nuts, washers split pins of appropriate size as required complete all as specified and as directed. |
| 70 | Supply only blade (set of 03) suitable for 1200 mm sweep complete all as specified and as directed. |
| 71 | Supply only ball bearing of size 6201/6202 suitable for ceiling fan 1200/1400mm sweep complete all as specified and as directed. Make : NBC/SKF/SBBI |
| 72 | Supply only ball bearing suitable for exhaust fan 300/380/450 mm sweep complete all as specified and as directed.Make : NBC/SKF/SBBI |
| 73 | Remelting to worn out shaft of fan motor turning complete to obtain the standard dia of shaft for fixing standard size bearing/bushes to ceiling fan of size1200/1400mm sweep of any make complete all as specified and as directed. |
| 74 | S&F Electric cable PVC insulated with copper conductor (flexible cable) round sheathed 1100 volts confirming to IS-694 of size-0.50 Sqmmtwin core for connecting fan to electric system including dismantling of old wire complete all as specified and as directed. |
| 75 | M & L for painting of ceiling fan 1200mm/1400mm sweepcomplete with blades with synthetic enamel paint Duco by spraying including filling cavities with filler, ones coat after cleaning all dust etc and writing MES No with synthetic enamel black paint complete all as specified and as directed. |
| 76 | Allas per item serial No 75 here-in-before butfor exhaust fan of size 200mm/300mm sweep complete all as specified and as directed. |
| 77 | Allas per item serial No 75 here-in-before butfor exhaust fan of size 380mm/450mm sweep complete all as specified and as directed. |
| 78 | S & F in repairs, single phase exhaust fan motor of 300 mm sweep having ,copper wound, AC, 230 Volts, 50 HZ, ISI marked complete with all standard accessories complete all as specified and as directed. |
| 79 | S & F in repairs, Exhaust fan blade metal typesuitable for 300 mm exhaust fan or as per site requirement complete all as specified and as directed. |
| 80 | S&F in repairs, Exhaust fan Frame metal type of size up to 300 mm sweep as per existing size suitable for any make including bolt, nut, if required etc complete all as specified and as directed. |
| 81 | S & F in repairs, single phase exhaust fan motor of 380/450 mm sweep having 1400 RPM Speed,copper wound, AC, 230 Volts, 50 HZ, ISI marked complete with all standard accessories complete all as specified and as directed. |
| 82 | S & F in repairs, Exhaust fan blade metal typesuitable for 380/450 mm exhaust fan or as per site requirement complete all as specified and as directed. |
| 83 | S&F in repairs, Exhaust fan Frame metal type of size up to 380/450 mm sweep as per existing size suitable for any make including bolt, nut, if required etc complete all as specified and as directed. |
| 84 | Taking out old unserviceable louvers of any type at bldgupto G+3 storey, supply and fixing exhaust fan louver of size 300/350 mm sweep made out of MS sheet complete including making good the disturbed surface of wall both inner and outer side and match with the existing complete all as specified and as directed. NOTE- Contractor will make all arrangement of safety devices and necessary T&P, and department will not be held responsible for any kind of accident and damage caused to man and machinery. |
| 85 | Taking out old unserviceable louvers of any type upto G+1 storey, supply and fixing exhaust fan louver of size 450 mm sweep made out of MS sheet complete including making good the disturbed surface of wall both inner and outer side and match with the existing all as specified and directed.NOTE- Contractor will make all arrangement of safety devices and necessary T&P, and department will not be held responsible for any kind of accident and damage caused to man and machinery. |
| 86 | Taking down carefully storage type water heater of 25/35/50 litres capacity (Geyser) after disconnecting inlet/outlet/vent pipes, electric/earth connections etc cleaning of the body inlet/outlet/vent pipes, stop valve, non return valves etc leakage arresting of inner copper/steel tank by wielding/brazing etc reassembling the geyser by replacing gaskets worn out nuts washers etc refixing the same in position,reconnecting all inlet/outlet/vent pipes electric/earth connections and carrying out testing for proper functioning all as directed by Engineer-in-Charge.Note : Non return valve, stop valve, bib tap/ PVC connection/Copper connections cable, glass wool, element, thermostat,indicator etc shall be measured separately. |
| 87 | Supply only heating element 1.5Kw/2.0Kw with round/triangular base, push and clamp fixing type suitable for 25/50 Liters capacity geysers complete all as specified and as directed. |
| 88 | Supply only thermostat switch for 25/50 Ltrs Geyser, 230 V, 30 degree to 90 degree centigradetemp range to be set at 70 degree to50 degreecenti grade suitable for water heater complete all as specified and as directed. |
| 89 | Supply only non return valve of suitable sizefor geyser complete all as specified and as directed. |
| 90 | Supply only glass wool for insulation of tank as approved complete all as specified and as directed. |
| 91 | Supply only indicator lamp suitable for 25/35/50 Ltrs geysers as per existing sample in green and red colour complete all as specified and as directed. |
| 92 | Supply only heavy duty PVC connection pipe 15 mm bore dia, 450 mm long, suitable for hot & cold water supply with chromium plated brass screwed nuts at both ends with washers for making water connection of inlet & outlet from geyser to GI pipe 15mm bore dia complete all as specified and as directed.Supply and fixing in repalcementconnection pipe 18 Inch long and 15 mm bore flexi connection pipe for both hot and cold watersuitable for storage water geyser Complete all as specified and directed. |
| 93 | S&F in repairs, Geyser SS assembly/aperture platefor housing Heating element, 6/8/9 Holes type for 50/35/25 ltr for storage type Geyser complete all as specified and as directed. |
| 94 | S&F in repairs, SS container suitable for Geyser 25/35 ltr with MS collar complete all as specified and as directed. |
| 95 | S&F in repairs, polycarbonate Plug top 15 Amps, 3 pin 240 Volts complete all as specified and as directed. |
| 96 | S & F GI tubing 20mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors including dismantling of old tubing complete all as specified and as directed. |
| 97 | S & F GI tubing 25mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors including dismantling of old tubing complete all as specified and as directed. |
| 98 | M&L for Servicing and maintenance of solar water heater of capacity upto 300 litre FPC type cleaning tank and collector with acid and water including replacement of connector, socket, PVC pipe all as specified and directed.Note: Job will be carried out on rooftop and existing system installed at a height of 25 m above the normal ground level, necessary requirement of T & P for execution of work is deemed to be included in unit rate. |
| 99 | taking down old unserviceable broken solar water heater flat plate collector of 100 Litre capacity from existing system installed at roof top (Approx 25m from normal ground level)by unscrewing complete nuts, bolts and screws and removal of other filaments/accessories like inlet and outlet water supply pipe lines, valves etc.complete all as specified and as directed. Note: Job will be carried out on rooftop and existing system installed at a height of 25m above the normal ground level, necessary requirement of T & P for execution of work is deemed to be included in unit rate. |
| 100 | supply, fixing, commissioning and testing of stainless steel flat plate collector for solar water heater of capacity 100 litre (total system capacity 200/300litre) 250 Kpa, roof mounted complete with all connected accessories and connection of water supply pipe line for input and output supply and suitable for existing system complete all as specified and as directed. Note: - (i) PCC, grouting, foundation work for channel shall be included in quoted rate.(ii) Job will be carried out on rooftop and existing system installed at a height of 25 m above the normal ground level, necessary requirement of T & P for execution of work will be included in unit rate. |
| 101 | Taking down / dismantling carefully existing solar water heater tank of capacity 300 litre by unscrewing all fitments and water supply pipe lines and removal of tank from the system complete including any minor work required at site complete all as specified and as directed.Note: Job will be carried out on rooftop and existing system installed at a height of 25 m above the normal ground level, necessary requirement of T & P for execution of work will be included in unit rate. |
| 102 | supply ,fixing, commissioning and testing of stainless steelsolar water heater tank of capacity 300 litre ,(total system capacity 300litre) roof mounted complete with all connected accessories and connection of water supply pipeline for input and output supply and suitable for existing system complete alas specified and as directed including Tank stand of required size , PCC, grouting ,foundation work shall be included in quoted rate. Note: Job will be carried out on rooftop and existing system installed at a height of 25 m above the normal ground level, necessary requirement of T & P for execution of workwill be included in unit rate. |
| 103 | M&L for Cross arms, bracings, supports, clamps, eye hook and back plates fabricated from structural steel sections including pole clamps, stay clamps, D clamps nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and including two coats of aluminuum paint over a coat of red oxide primer including dismantling of old cross arms complete all as specified and as directed. |
| 104 | S&F in repairs,fountain light any colour any type as per existingsample , waterproof5/6Wcomplete all as specified and as directed. |
| 105 | Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation, laying of pipe or for shafts, wells cesspits, man holes, pier holes, laying of cable etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed. |
| 106 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in soft / loose soil complete all as specified and as directed. |
| 107 | Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed. |
| 108 | Supply, laying and testing XLPE Insulated , PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 35 sqmm 3.5 core laid in trenches /floor or fixed on wall/pole in existing or new location including brass compression cable glands, terminal lugs etc,including dismantling of old cable of any description complete all as specified and as directed. |
| 109 | M&L for sand cushioning with dry river sand in trenches for cushioning of underground cable including spreading, leveling, punning down the thickness of sand upto 18cm and consolidated complete all as specified and as directed.Note: Punned thickness of sand cushioning will be measured and paid. |
| 110 | M&L for sub class ‘B’ old size well burnt brick laid flat in trenches with length of brick perpendicular to length of cable, over the cable forprotection of LT cable complete all as specified and as directed. |
| 111 | M & Lfor earthing in replacement complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers, galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cm X 5 cm with 10mm dia TMT bars 8 cm C/c both ways andone handle for lifting made out of 8 mm dia TMTbar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I including dismantling of old earthing complete all as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy