| 1 | Supply and fix 15 mm borehot water pipe duly insulated with glass wool and aluminium cladding including all fittings as in wall, ceiling or laid in floor including all chase cutting in any type of surface complete all as specified and as directed. |
| 2 | Supply and fix 20 mm bore GI Pipe medium grade confirming to IS 1239:2004 (Part-4) hot water pipe duly insulated with glass wool and aluminium cladding including all fittings as in wall, ceiling or laid in floor including all chase cutting in any type of surface complete all as specified and as directed. |
| 3 | Material and labour for brick work with subclass \"B\" bricks straight or curved on plan exc 6M mean radiusbuilt in cement mortar (1:6) complete all as specified and as directed. |
| 4 | Material and labour for reinforced precast RCC (1:2:4), type B-1, using 20 mm nominal size graded crushed stone aggregate as in 75 mm thick drain cover slab and setting in cement mortar (1:4) complete with joints to match including all necessary formwork complete all as specified and as directed.Note:- Reinforcement shall be measured and paid separatly. |
| 5 | M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed. |
| 6 | Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed. |
| 7 | M & L for preparation of newly plastered surface of wall and applying two coats cement base paint over one coat of primer upto 4th storey building complete all as specified and as directed. |
| 8 | Supply and fixed in repairs 15 mm dia brass CP fancy wall mixer non telephonic for mixing hot & cold water screwed down for iron pipe complete including all fitting flange complete all as specified and as directed. |
| 9 | Excavation in trenches n exc 1.5 m wide and n exc 1.5 m in deep and getting out in soft/soft soil complete all as specified and directed |
| 10 | M & L for Cement concrete (1:4:8) type D2 (using 40 mm graded stone aggregates) as in fountation filling and mass concrete complete all as specified and as directed. |
| 11 | M&L for RCC (1:2:4) typeB1 using 20 mm graded stone aggregateasin foundation, including raft, footing, foundation beams, plinth beam, bases for column, slab for culvert etc complete all as specified and directed by Engr-in-Charge |
| 12 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and sofits (if any) of foundation and plinth beams in flate and similar work vertical or to batter rough finished surfaces of concrete complete all as specified and as directed |
| 13 | M&L forRCC (1:2:4) type B1 using 20mm graded stone aggregate in column, pillars, piers, posts and struts etc compete as specified and directed by Engr-in-Charge |
| 14 | Use and waste of form work to faces of sides of pillars, posts, struts, piers, columns and stanchions in flats vertical rough finished surface complete all as specified and directed |
| 15 | M&L for hardcore of broken bricks of guage n exc 63 mm deposited spread and levelled in layers n exc, 15 cm thick watered and rammed to a true surface complete all as specified and directed |
| 16 | S& Fmild steel (TMT) bars 10 mm dia and over, cut ot length, bent to shape required,including cranking,bending spirally for hooping for column, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed |
| 17 | S&F Mild steel (TMT) bars 5mm dia and over upto and including 10 mm dia in stirrups, spacers and binders, cut to length to shape required, including cranking bending spirally for hooping for column, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clipscomplete all as specified and as directed |
| 18 | M&L forrendering 15 mm thick with CM (1:4) on brick or concrete surfacesand mixing with WPC as per manfacturer instruction finished surfaces even and fair with out using extra cement complete all as specified and as directedNote : WPC shall be measured and paid seperately |
| 19 | Supply only intergral water profing compound |
| 20 | M&L forpreparation of new surfaces of wall and applying one coat of chalk whiting on plastered surface with alkali resistant priming paint two coats complete all as specified and directed |
| 21 | S&F rolled mild steel framed work as in doors or Gates of angle or other section with gussed plates, rails, braces etc complete drilled for fixing of stell sheeting or other covering door etc to be prepared for hanging or sliding with & including either hooks & hinges or steel hanging door also fastening and fixing complete Gde FE 410 - W or Fe E Quality A complete all as specified and directed |
| 22 | S&F rolledmild steel plates (Plain or chequred) channels, Squires or cut of notched (Ordinary and counter sunk) forming holes, without any attchment Gde Fe 410-W or Fe E-250 quality A complete all as specified and as directed |
| 23 | Returning filling in including spreading levelling watering and well ramming in layers not exc 25 cmcomplete all as specified and as directed |
| 24 | Removing excavated surplus soil to a distance exc 1.5 km and n. exc 5.0km and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified & directed. |
| 25 | M&L for Providing reinforced cementconcrete type B-l, 1:2:4 (20 mmgraded aggregate) in precastposts, fencing posts, straining or terminal posts, struts etc. forfencing, average sectional arean exc 100 sq. cm, with orwithout chamfered angles andflat, splayed, rounded or mitredtop complete all as specified & directed. |
| 26 | Design, Supply, Install, Testing and Commissioning of \"Solar Hot Water System\" (Flat Plate Collector) based on indirect transfer of heat of capacity 300 LPD with electrical heating back up complete inclusive of base foundation as per OEM direction, MS agle iron etc are included in quoted rate complete all as specified and directed. |
| 27 | Design, Supply, Install, Testing and Commissioning of \"Solar Hot Water System\" (Flat Plate Collector) based on indirect transfer of heat of capacity 100 LPD with electrical heating back up complete inclusive of base foundation as per OEM direction, MS agle iron etc are included in quoted rate complete all as specified and directed. |
| 28 | Supply and laying, 40 mm bore \"Medium grade\", galvanised, with all fitting; laid in trenchesof following sizecomplete all as specified and directed. |
| 29 | M&L for fixing 40 mm bore GM globe gate valve with iron wheel head screwed both end for iron pipe and fixed Complete all as specified and directed. |
| 30 | M&L for Cutting / drilling the existing GI pipe 50/40/25 mm dia pipe including CI/DI/GI tee, bend, tapper etc all necessary items all as specified and as directed. |
| 31 | M & L for carrying out Energy Audit for Electrical Installations and equipment (HT/ LT)held atVikram Enclave, Azadhind Nagar,Jetty & DHQ-8by BEE certifed auditor considering following scope of work and submission of audit report post analysis:-(i) Study of connected loads/ substation HT equipments i.e 2 pole structure, VCBs, Transformer, LT Panels etcas per records available in the premises,(ii) Analysis of monthly electricity bill for last one/two years,(iii) Measurements of different electrical parameters like V, I, PF, kW, kVA, kVAr, Voltage unbalance, Current Unbalance, Harmonic etc. by hand held power analyser for LT Feeders & data analysis/loss analysis & exploring further energy saving potential,(iv) Conduct trial run of existing Diesel Generating Sets for 30 minutes each & evaluation of Specific Fuel Consumption & Generation,(v) Psychometric Study of Air-conditioners (Split/Window), comprising of supply air flow, dry bulb temperature & wet bulb temperature at supply side & return side; measurements of V, I, PF & kW; Checking of Filter Condition, Evaporator Coil Condition & Condenser Coil Condition & exploring further energy saving potential,(vi) Study of Transformers, Motors & Pumps by power measurement, flow & head estimation & exploring further energy saving potential,(vii) Study of indoor & outdoor Lighting System, comprising of illumination measurements, counting of type of lighting fixture, number of lighting fixture & wattage of lighting fixture, power measurement, analysis of installed Load Efficacy Ratio, Lighting Power Density & exploring further energy saving potential,(viii) Study of Ceiling Fans, Wall Fans & Stand Fans, comprising of type of fan, number of fan & wattage of fan, power measurement, and analysis of daily energy consumption & exploring further energy saving potential. |
| 32 | Supply and Laying of Cat-6 Armoured cable complete all as specified and directed. |
| 33 | Supply and Laying of 1.5 Sq.mm 2 Core Armoured outdoor speaker cable including soft/hard soil digging and refilling complete all as specified and directed. |
| 34 | Supply and Laying of suitable size HDPE pipe including soft/hard soil digging and refilling complete all as specified and direted. |
| 35 | Supply and laying of suitable size 25mm diaHeavy duty PVC pipe including soft/hard soil digging and refilling complete all as specified and directed. |
| 36 | Supply and fixing of Speaker clamp for mounting complete all as specified and directed. |
| 37 | Supply and fixing of Cat-6 patch cord (P30 cord) complete all as specified and directed. |
| 38 | Supply and Fixing Wiring for circuit/submain wiring along with earth wireof 2x2.5 sq. mm + 1x2.5 sq. mm earth wire sizes of FRLSH is PVC insulated copper conductor, single core cable in surface/ recessed as required complete all as specified and directed. |
| 39 | M & L Switch Modular type single pole, one way 6 Amp complete all as specified and directed. |
| 40 | S & F Modular White cover plate with frame 1/2 M complete all as specified and diercted. |
| 41 | S & F Metal flush box 1/2 module complete all as specified and diercted. |