| 1 | B&R PORTION:Demolition of cement concrete unreinforced in ground floors pavings nexc 15 cm thickness below or above ground levels complete all as specified and directed. |
| 2 | M&L for 75 mm thick cement concrete Type D-2, 1:4:8 (40mm graded aggregate) as in sub base complete all as specified and directed. |
| 3 | M&L for chequered PU glossy finishes coloured cement concrete tiles size 30cm x 30cm x 25 mm thick set ,jointed and pointed in colour cement and pigment and fixed with cement slurry in floors including 20mm thick screed bed or bedding layer in CM 1:4 complete all as specified and directed. |
| 4 | Removing building materialsto a distance up to 5 KM under, beyond the lead incl in the rates incl loading, unloading and stacking at the destination complete all as specified and directed. |
| 5 | Surface excavation not exc 30cm deep and averaging 15cm deep and and getting out in hard or dence soil complete all as specified and directed. |
| 6 | Excavating in post holes in Hard/dense soil (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed. |
| 7 | M&L for providing and laying at or near ground level factory made kerb stone of M25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete all as specified and directed. |
| 8 | M&L for one coat of synthetic enamel paint in any approved pattern and colour including preparation of new surface of kerb stone/ concrete/ plaster surface exc 10cm width or girth not otherwise provided complete all as specified and directed. |
| 9 | M&L for PCC 1:3:6type C2 Cement concrete in foundations, filling and mass concrete complete all as specified and directed. |
| 10 | Removing excavated material of hard /dense soil exc. 1.50 km but n exc. 5 km and depositing out side the MOD land complete all as specified and directed. |
| 11 | M&L for Hard core of broken stones or boulders of gauge not exe 63mm, deposited spread, levelled in layers n exc 15 cm thick incl watering and rolling with power roller 8 to 12 Ton complete all as specified and directed by Engr-in-charge. |
| 12 | M&L for Cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as in sub base, 75mm thick, finished fair and even without using extra cement, complete all as specified and directed. |
| 13 | M&L for cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in coping, band, bed plates and similar items including weathering slightly rounded or chamfered angles and througting, complete all as specified and directed. |
| 14 | M&L for Sand for 50 mm thick filling under interlocking paver block including watering and consolidation complete all as specified and directed. |
| 15 | M&L for Machine pressed precast concrete interlocking coloured paver block with ceramic/glossy finish any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade complete all as specified and directed By Engr-in-charge. |
| 16 | S&F MS works for fencing post and struts including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting, etc conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 17 | M&L for Mild Steel round bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for securing and supporting of of wiremesh confirming to Gd.I, IS-432 or Fe-290 (Gde-E-165) complete all as specified and directed. |
| 18 | Fixing only chain link MS galvanised fencing of any size with GI wire including line wires any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and directed. |
| 19 | Supply only galvanisedchain link fencing 3.40 mm dia & 100x100 meshincluding line wireswtn. exc 4.00 Kg/Sqm complete all as specified and directed. |
| 20 | S&F mild steel screw bolt (machine made) with square or hexagonal head at one end, screwed other, fitted with washer and one hexagonal or square n exc 5cm long and 10mm dia complete all as specified and directed. |
| 21 | M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors;door in fencing ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 for portionsframedandhungas gates,includingpintlehinges, stops,hand-made sliding bolts, etc complete all as specified and directed. |
| 22 | M&L for preparation of new or previously untreated surfaces, of steel and iron work of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of Red oxide complete all as specified and directed. |
| 23 | M&L for preparationof new or previously untreated surfaces of steel of any description, n exc 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 24 | Supply and plantaion of grass selection No 1(A1 quality grass) by dibbling root method complete all as specified and directed.Note :-(1) The following activities/work to be carried at site for plantation of grass selection No 1-(a) Levelling the existing dense/hard soil averaging 10cm level after loosening and filling soft loose soil 20mm thickness on entire park area sufficient to grow up A1 quality grass. (b) Ploughing of whole site in soft /loose/ordinary soil upto the depth of 20 cm and removing all the unwanted material such as stone, weeds tree root etc which are not suitable for healthy growth of grass.(c) Dressing and leveling the soil to a required gradient and slope on completion of work mentioned in Note (a) and (b) above after loosening the soil.(d) Mixing of fertilizer and manure evenly by manually as under and as directed.Manure :- (i) Old cow dung or Okhla sludge at a rate of 2.25 cutz c foot for 10 Sqm.Fertilisers :-(i) Neem kholi at the rate of 2 kg for 10 Sqm(ii) Benemeal at the rate of 1 kg for 10 Sqm(iii) D.A (16.42) at the rate of 0.15 kg for 10 Sqm(iv) BHC dust 10% or lindance dust at the rate of 0.15 kg for 10 Sqm(e) Fine dressing a top soil after mixing the manure and fertilizer to required slope.(f) Watering the area for fine dressing of soil after one week till the soil get water upto.(g) Fine dressing of surfaces of top soil to require slop and gradient towards the manholes.(h) Plantation of grass @ 10 Cm do both way by dibbling root method(2) Rates include supply and transportation of manure, Fertilizers, sweet, earth,soft soil filling, ATT Chemical & sand complete all as specified and directed. |
| 25 | Maintenance of all plants, shrubs, Hedges, grass etc for a period of 06 month after date of completion by employing 3 (three) skilled Gardener per day to ensure healing up keep,of watering plant, pour manure, carryout periodic tilling and use pesticides, cutting grass and removing unwanted grass & plants at work site complete all as specified and directed.Note :-(i) During the period any plant, shrubs, grass etc is found dead, not true to name or size as specified or not in satisfactory growth plat of approved size & shape shall be replaced by the contractor.(ii) If contractor fail to comply above points the work will be carried out through other agency and amount will be recovered from the earnest money and 10% of reserved money (10% of contract amount will be kept for guarantee period.(iii) Supply & application of manure, sweet earth sand, ATT Chemical & pesticides etc, Fertilisers etc are included in the quoted unit rate during Maintence period. |
| 26 | E&M PORTION:Supply, installation, testing and commissioning of hi wall split AC units indoor/outdoor complete with cordless remote control unit, having minimum 3 star rated and with cooling and heating function of capacity 1.5 TR complete set with all connected accessories complete all as specified and directed by Engineer-in-Charge.Make : Blue Star/Hitach/Daikin/Voltas |
| 27 | Supply, installation, testing and commissioning of hi wall split AC units indoor/outdoor complete with cordless remote control unit, having minimum 3 star rated and with cooling and heating function of capacity 2.0 TR complete set with all connected accessories complete all as specified and directed by Engineer-in-Charge. Note for Ser No 26 & 27 : (i)Fixing charges is deemed to be included in the quoted rate. All fixing materials deemed to be included in the quoted rate.(ii) The rates includes connection copper piping as per site requirement including jointing & brazing work. The cost of required T&P for this work is deemed to be included in this quoted rate. Nothing extra to be paid on this account. Make : Blue Star/Hitach/Daikin/Voltas |
| 28 | S&F Voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V - 270V with output voltage stabilized at 230 V with accuracy of± 2.5% and of capacity 3.0 KVA complete all as specified and directed. |
| 29 | S&F Gravity Feed type Gaseous Chlorinator complete set as per manufacturer\"s instruction of capacity 2.0 to 5.0 Kg/hr for water supply installation at NSB-I. The Chlorinator complete set includes PVC piping arrangement including fixing accessories from Chlorinator set to under ground sump to make it fully functional complete all as specified and directed by Engineer-in-Charge. Note : (i) The complete materials and labour cost is deemed to be included in this rate. Necessary exavation cost is included in this rate. Nothing extra shall be paid on this account. (ii) The chlorinator to be fixed on wall. Necessary fixing materials and labour charges is deemed to be included in this rate. Nothing extra shall be paid on this account. |
| 30 | S&F Chlorine gas Cylinder suitable to store minimum 15 kgs of chlorine gas with connected fixing accessories complete all as as per manufacturer\"s instruction complete all as specified and directed by Engineer-in-Charge. |
| 31 | S&F Chlorine gas suitable for treatement of water complete all as specified and directed by Engineer-in-Charge. Notes. (i) Transportation charges for collection of empty gas cylinder from site and after filling of gas the same return to the site is deemed to be included in this rate. Nothing extra paid on this account.Note: (a) Srl Item No 03.00, 07.00, 11.00, 12.00, 14.00 to 16.00, 18.00, 19.00, 24.00 & 26.00 to 29.00 of BOQ are major items for the subject tender and material in respect of these items shall be procured within one month after placing of work order and produced before Engg in Charge alongwith original purchase vouchers as per direction of Garrison Engineer and shall obtain a certificate from Engg in charge that material in respect of above mentioned items have been submitted in the office of Engg in charge in their safe custody.(b) Materials in respect of Freakishly low declared items if any at the time of acceptance of contract shall be procured within one month after placing of work order and submit the same in the office of Engg in charge alongwith original purchase vouchers in their safe custody and shall obtain a certificate from Engg in charge. |