| 1 | Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding fittings but includingswitches, ceiling roses, pendants, regulators, sockets, etc.and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed. |
| 2 | M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathedFRLS cable, 1100 volts grade IS-694marked, with multistranded copper conductors and earthcontinuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly)laid/fixed with and including PVC rigid conduit concealed wiring on walls/ceiling, and with sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top covers for one light/fan/exhaust fan/bell point controlled by one number one way5 /6/10 Amp switch complete all as specified and as directed.Note : Cutting chases for concealed type wiring including making good the same with plaster/ putty is deemed to be included in quoted rate. |
| 3 | Allas per item serial No 2 here-in-before butfor One 3 pin 5/6/10 Amp switch socket outlet on independent board. |
| 4 | Allas per item serial No 2here-in-before butfor One 3 pin 5/6/10 Amp switch socket outlet on same board with other switches. |
| 5 | All as per item serial No 2 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cableand earthcontinuity wire with 2.5 Sqmm cable for 6 pin 15/20 Amp socket outlet on independent board. |
| 6 | M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathedFRLS cable, 1100 volts grade IS-694marked, with multistranded copper conductors and earthcontinuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly)laid/fixed with and including PVC Casing and Caping or surface wiring on walls/ceiling, and with sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top covers for one light/fan/exhaust fan/bell point controlled by one number one way 5 /6/10 Amp switch complete all as specified and as directed. |
| 7 | Allas per item serial No 6 here-in-before butfor One 3 pin 5/6/10 Amp switch socket outlet on independent board. |
| 8 | Allas per item serial No 6here-in-before butfor One 3 pin 5/6/10 Amp switch socket outlet on same board with other switches. |
| 9 | All as per item serial No 6 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cableand earthcontinuity wire with 2.5 Sqmm cable for 6 pin 15/20 Amp socket outlet on independent board. |
| 10 | S & F switch piano, flush type single pole one way 5/6 Amps 230/240 volt complete all as specified and as directed. |
| 11 | S&F in repairs, switch piano, flush type single pole one way 5/6 Amps 230/240 volt complete all as specified and as directed. |
| 12 | S & F switch piano, flush type single pole one way 15/16/20 Amps 230/240 volt complete all as specified and as directed. |
| 13 | S&F in repairs, switch piano, flush type single pole one way 15/16/20 Amps 230/240 volt complete all as specified and as directed. |
| 14 | S&F socket outlet 3 pin, 2-in-1, 5/6 Amps, flush type240 volts complete all as specified and as directed |
| 15 | S&F in repairs, socket outlet 3 pin, 2-in-1, 5/6 Amps, flush type240 volts complete all as specified and as directed |
| 16 | S & F Socket outlet 2 in 1, 3 pin, 5/15 amps, flush type, 240 volts complete all as specified and as directed. |
| 17 | S&F in repairs, Socket outlet 2 in 1, 3 pin, 5/15 amps, flush type, 240 volts complete all as specified and as directed. |
| 18 | S & F lamp holder, insulated, PVC / polycarbonate /bakelite body complete all as specified and as directed. |
| 19 | S&F in repairs, lamp holder, insulated, PVC / polycarbonate /bakelite body complete all as specified and as directed. |
| 20 | S&F bell push, flush type, 5/6 Amps 230/240 volt complete all as specified and as directed. |
| 21 | S&F in repairs, bell push, flush type, 5/6 Amps 230/240 volt complete all as specified and as directed. |
| 22 | S & F call bell Ding Dong AC ,230 volts single pole complete all as specified and as directed. |
| 23 | S&F in repairs, call bell Ding Dong AC ,230 volts single pole complete all as specified and as directed. |
| 24 | S & F stepped type electronic fan regulator, flush type complete all as specified and as directed. |
| 25 | S&F in repairs,stepped type electronic fan regulator, flush type complete all as specified and as directed. |
| 26 | S & F ceiling rose surface bakelite, 65x50mm three terminal complete all as specified and as directed. |
| 27 | S&F in repairs, ceiling rose surface bakelite, 65x50mm three terminal complete all as specified and as directed. |
| 28 | S&F in repairs, Modular switch 1 way 6A/10A, 1 module, single pole one way complete all as specified and as directed. |
| 29 | S&F in repairs, Modular switch 1 way 16A/20A, 1 module complete all as specified and directed. |
| 30 | S&F in repairs,Modular socket6A/10, 2/3 pin combined2 module complete all as specified and as directed. |
| 31 | S&F in repairs,Modular socket, 6/16A or 10/20Amp, 2/3 pin combined 2 module 240 volts, shuttered type complete all as specified and as directed. |
| 32 | S&F in repairs, Modular stepped type electronic fan regulator 120W two module size, flush typecomplete all as specified and as directed. |
| 33 | S&F in repairs, Modular metal flush box 3 module complete all as specified and as directed. |
| 34 | S&F in repairs, Modular metal flush box 4 module complete all as specified and as directed. |
| 35 | S&F in repairs, Modular metal flush box 6 module complete all as specified and as directed. |
| 36 | S&F in repairs, Modular metal flush box 12 module complete all as specified and as directed. |
| 37 | S&F in repairs,white cover plate with frame 3 module complete all as specified and as directed. |
| 38 | S&F in repairs,white cover plate with frame 4 module complete all as specified and as directed. |
| 39 | S&F in repairs,white cover plate with frame 6 module complete all as specified and as directed. |
| 40 | S&F in repairs,white cover plate with frame 12 module complete all as specified and as directed. |
| 41 | S&F in repairs,galvanised iron sheet Box thickness not less than 1mm as in concealed wiring of any type and any size complete all as specified and as directed. |
| 42 | S&F integral LED 4ft luminaire of CRCA / extruded aluminium housing and PC diffuser (Diffuser-Non yellowing type). The luminaire should have a 20 Watt LED with colour consistency SDCM< 5,CRI> 80 and colour temperature - 4000 to 6500K, Luminaire shall be designed to emit at least 2400 nominal lumens at a system efficacy of at-least 120 lumen/watt, power consumption should not be more than 20W (+5%). the life of fixture (including Driver): 50000 burning Hrs.@ L70B50 Lumen maintenance @ design ambient temp 50 deg C. The electronic driver used shall have a power factor >0.95 and THD < 10% suitable for an operating voltage range of 150-270V AC current Ripple<5% internal surge protection should be minimum 4KV, electrical insulation class should be Class I &driver should be of class B serviceability. The luminaire should be at least IP20 & IK02 rated. The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have in house NABL accredited lab conduct LM79, type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for luminaire manufacturer along along with sample approval. The LED Luminaire & It\"s driver both should be BIS registered contractor shall submit the following reports before supply of material for approvals LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer type test certificate for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver including dismantling of old tube light fitting of any descriptioncomplete all as specified and as directed. |
| 43 | S&F integral / batten LED 2ft, 10watt 220 V, luminaire made of CRCA / extruded aluminium housing and PC diffuser (Diffuser-Non yellowing type). The luminaire should have a LEDs with colour consistency SDCM ≤ 5, CRI ≥ 80 and CCT of 6500K. Luminaire shall be designed to emit at least minimum 1200 system lumens at a system efficacy of at-least 120 lumen/watt. Power consumption should not be more than 10W (± 5%). The Life of fixture (Including Driver):50000 burning Hrs. @ L70B50 Lumen maintenance @ design ambient temp 45 deg C. The electronic driver used shall have a power factor 0.95 and THD ≤10%, suitable for an operating voltage range of 140-270V AC, Current Ripple ≤ 5%, Internal surge protection should be minimum 4KV, electrical insulation class should be Class I & driver should be of Class B serviceability. The luminaire shall be IP20 & IK02 compliant. The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with Sample Approval. The LED Luminaire & it\"s driver both should be BIS registered. The contractor shall submit the following reports before supply of material for approvals LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredit lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver including dismantling of old tube light fitting of any description complete all as specified and as directed. |
| 44 | S&F in repairs, 15w/20W recess mounted downlighter pressure die-cast aluminium luminaire in powder coated white finish in roundprofile with optimized heat sink for efficient heat dissipation and integrated driver complete all as specified and as directed.Make: HavellsModel : VIBETRENDRDDLR15WLED840S/VIBETRENDSQDLR15WLED840SPhilipsModel : DN296B LED15S-6500 PSE WH S2 9405/ DN496 LED15S-6500 PSU WH orequivalent model in make of Crompton/Bajaj |
| 45 | S&F in repairs, Decorative wall light fixture made up of Polycarbonate suitable for lamp (B22) including suitable size LED Bulb(9W) etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. |
| 46 | S&F in repairs Environmentally friendly, ultra modern, energy saving, Pressure die cast housing 10 W LED bulkhead with IP66 protection and IK09 impact resistance suitable for surface and wall mounting applications comprising of high brightness LEDs complete all as specified and as directed.Make:- Philips Model : WT202W LED10S CW PSU S3 PC/WT202W LED10S NW PSU S3 PC or Havells Model HEXAFT10WLED857SSYMBOPC or equivalent Model of make Crompton /Bajaj/Wipro. |
| 47 | S&F in repairs , LED luminaire 600 mm x 600 mm, 40 watts, 220 Volts, AC, recessed/surface, white/warm type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver andflexible copper conductor cable of suitable size complete all as specified and as directed. |
| 48 | S&F New generation LED post top lantern, 20 Watts, 230 Volts, AC outdoor type with decorative post top for 360 degree indirect lighting IP-65 protection with impact and corrosion resistant complete with driver and lamp complete with all electrical accessories including taking down old unserviceable post top light fitting complete all as specified and as directed. |
| 49 | S&F New generation LED post top lantern, 35/40 Watts, 230 Volts, AC outdoor type with decorative post top for 360 degree indirect lighting IP-65 protection with impact and corrosion resistant complete with driver and lamp complete with all electrical accessories including taking down old unserviceable post top light fitting complete all as specified and as directed. |
| 50 | S&F LED street light fitting of high-quality group control enabled integrated LED Bldg Security light with a minimum system lumen of min 4900 lm and system wattage not less than 35W with a nominal system efficacy of 140 lumen/watt. The LED used shall have CCT of 5700K, SDCM ≤ 5 and CRI≥70. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure die-cast aluminum, to withstand extreme environments. The spigot shall be part of “Single Piece Pressure Die-cast housing” & shall not be bolted to the luminaire housing to ensure robust design. The name of the brand should be embossed/engraved & should not be mentioned using sticker/screen printing. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. The luminaire LED shall have declared Lifetime of 50K hours@L70B50. The product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 & impact resistance shall be IK10. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 20 KV/10KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The Driver should be asphalt potted & should be a BIS approved driver. The driver shall have operating voltage of 120V to 270V, PF≥0.95 @ full load, THD≤10% @ full load. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547 & IEC 61000-3-2.The luminaire driver & it’s SPD shall be of the same make/manufacturer as that of LED luminaires.Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with Sample Approval. The LED Luminaire & it\"s driver both should be BIS registered. The contractor shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test report for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete including taking down old unserviceable light fitting upto 9 metre height from the normal ground level complete all as specified and as directed. |
| 51 | S & F LED based Flood light, housing made up of pressure die cast aluminium Alloy with of pressure die cast aluminium Alloy with effective thermal management & sturdiness. The fixture should have a minimum system efficacy of 120 lumen/ Watt and a minimum system lumen output of 14400 lumens and minimum system wattage of 120 Watts. The LEDs used shall be 50000 Hrs @ L70B50 Ingress Protection of IP66 and Mechanical Impact Resistance Rating of IK ≥07. The fixture driver should have an operating voltage range of 140-270 V, In - built surge protection of ≥4KV, PF ≥0.95 and THD≤10% at full load. The luminaire shall have 10 KV SPD bolted inside the luminaire. The luminaire driver & SPD shall be of the same make / manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \"FAT\" before dispatch as per IS 10322. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer along with Spec/Make Approval. The LED Luminaire & it\"s driver both should be BIS registered with a warranty of Min 3 years. Successful bidder shall submit the following reports along with Specs/Make Approval - LM79 issued by LED manufacturer, Type test Certificate for luminaire as issued by NABL accredited lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED luminaire & Driver including taking down old unserviceable flood light fittingcomplete all as specified and as directed. |
| 52 | Supply, fixing and testing of Solar street light fitting All-in-One Integrated type of 20 watts rating, LED type with solar panel of 30 watts, LED power 20 watts,Battery capacity-14AH, Lumen more than 1800 Lm, emitting colour cool white, 5700K with over charge device and backup for 08-10 hours of size 450mmx383mmx55mm complete fixed on wall/existing pole of any height ( 6M max from GL) complete all as specified and as directed. |
| 53 | S & F security lightbracket made out of GI pipe 32mm dia medium grade (bent to shape as directed ), 1.0 M long, fixed with MS flat iron clamps made out of 40 mm x 6 mmwith nuts, bolts, washers and other connected items of required size, suitable for steel tubular poles/wall and painting with one coat of aluminium paint over a coat of red oxide zinc chrome primer including taking down old bracket complete all as specified and as directed. |
| 54 | Taking down carefully AC single phase 220/230volt ceiling fan 1200/1400mm sweep single phase complete at site for rewinding ,rewinding with copper wound and replacement of unserviceable parts i.e Capacitor, PVC connector, MS galvanised check nut, ball bearing, rubber pads, PVC strip clamps includingservicing such as removing dust & dirt brushing, rubbing with cotton waste, , washing with detergent powder to fan blades, greasing bearing with ball bearing grease & washer packing, checking of bolts/nuts, washer check nuts split pin rubber packing and rubber seal etcincluding testing after assembling and connecting to electric systemcomplete all as specified and as directed by Engr-in-Charge. |
| 55 | Hanging only ceiling fan complete connecting up including provision of cable ,MS hook if required from ceiling rose or connector to fan complete all as specified and as directed. |
| 56 | M & L for 40 mm bore GI pipe (Light grade) fixed with wall suitable for hanging of ceiling fan of 1200 mm sweep, cable along pole including necessary cutting hole in brick/stone wall and making good the same with PCC 1:2:4 type C1 as required including dismantling old tube complete all as specified and as directed. Note- Rate quoted deemed to be included for GI pipe 40 mm bore fixed on wall for hanging ceiling fan includes making holes with PCC filling. |
| 57 | M&L for Sub main wiring with 2 runs of 4 sqmm, single core, FRLSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC concealed conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4 sqmm single core FRLSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and as directed. Note: (i) 2 run of 4 Sqmm cable and 1 run of 4 Sqmm cable along with conduit altogether shall be measured as one unit.(ii) Cutting chases for concealed submain wiring for the above point and making good in cement mortar is deemed included in quoted rate. |
| 58 | M&L for Sub main wiring with 2 runs of 6 sqmm, single core, FRLSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC concealed conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6 sqmm single core FRLSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and as directed. Note: (i) 2 run of 6 Sqmm cable and 1 run of 6 Sqmm cable along with conduit altogether shall be measured as one unit.(ii) Cutting chases for concealed submain wiring for the above point and making good in cement mortar is deemed included in quoted rate. |
| 59 | M&L for Sub main wiring with 2 runs of 10 sqmm, single core, FRLSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC concealed conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 10 sqmm single core FRLSHPVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and as directed. Note: (i) 2 run of 10 Sqmm cable and 1 run of 10 Sqmm cable along with conduit altogether shall be measured as one unit.(ii) Cutting chases for concealed submain wiring for the above point and making good in cement mortar is deemed included in quoted rate. |
| 60 | Disconnecting all electric connection and taking down old DBs (any type of Vertical load line/TPN/ SPN DBs) and making good to the disturbed surfaces to match the existing surface complete all as specified and as directed.Note – Temporary connection for power supply shall be done by contractor. |
| 61 | Refixing only old serviceable MCB DB of any size at existing or any other location with proper fixing and PCC work and connecting with MCB complete all as specified and as directed. |
| 62 | S & F vertical load line in sheet metal enclosures MCCB TPN DB\"s with double door for incorporating MCCB as incomer and MCBs SP/SPN as outgoing, IP-43 , TPN 4 way with 200 amps rated copper busbar, 440 volts, as per IS-8623 including taking out old DB and making good the disturbed surface of wall and match with the existing surface complete all as specified and as directed. Note- MCCB 3 pole 100 amps as main incomer shall be included in quoted rate. |
| 63 | S & F in repairs, factory made, sheet steel distribution boards, TPN, 4 Way, double door, protection class IP-43 with min 100 Amp rating copper bus bar, provision for FP MCB as incomer and SP MCBs as outgoing complete and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and as directed . Make :- Legrand Cat No 5076 70 or L&K Cat No DETPE004DDS or equivalent. model in Siemens / Schneider/Havells |
| 64 | S & F in repairs, Sheet metal enclosure for MCB DB Single door, single pole & Neutral 2 way without busbar complete all as specified and as directed. |
| 65 | S & F in repairs, single pole & neutral DBs 4 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed.Make:- L&K Cat No :DESPN004DDS, or Legrand Cat No :5076 10 or equivalent model of make Siemens/Schnider/HagerABB/Havells |
| 66 | S & F in repairs, single pole & neutral DBs 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed.Make :- Legrand Cat No 5076 11 orL&K Cat No DESPN008DDS or equivalent model in Siemens / Schneider/Havells. |
| 67 | S & F in repairs, single pole & neutral DBs 12 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed.Make :- Legrand Cat No 5076 22 orL&K Cat No DESPN012DDS or equivalent model in Siemens / Schneider/Havells. |
| 68 | S & F in repairs, Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp 240V complete all as specified and as directed. |
| 69 | S & F MCB TPN63 Amps,415 volts, 50 Hz, \"C\" curve including necessary incoming and out going electric connection with suitable size of copper lugs and testing complete all as specified and as directed. |
| 70 | S&FMCBs, SPN 6 to 32 Amps, 10 KA,\"C\" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 71 | S&FMCBs, SP 6 to 32 Amps, 10 KA, \"C\" curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. |
| 72 | Taking down existing electric meter carefully from the meter box and refixing the same in the same/new location complete all as specified and as directed. |
| 73 | S&F in repairs, heavy duty PVC connection pipe 15 mm bore dia, 450 mm long, suitable for hot & cold water supply with chromium plated brass screwed nuts at both ends with washers for making water connection of inlet & outlet from geyser to GI pipe 15mm bore dia complete all as specified and as directed. |
| 74 | S&F in repairs, heating element 1.5/2 KW ,ISI marked, 230 volts, AC, 50 Hz single phase power supply, suitable for storage type water heaters including making all connections completeall as specified and as directed. |
| 75 | S&F in repairs, thermostat suitable for 25/35/50 litre capacity storage type water heater as per sample including making all connections complete all as specified and as directed. |
| 76 | Excavation in trenches not exc 1.50 m wide and not exc 1.50 m deep for foundation, laying of pipe or for shafts, wells cesspits, man holes, pier holes, laying of cable etc not exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete all as specified and as directed. |
| 77 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm in soft / loose soil complete all as specified and as directed. |
| 78 | Removing excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point etc complete all as specified and as directed. |
| 79 | Supply, laying and testing XLPE Insulated , PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 16 sqmm 4 core laid in trenches /floor or fixed on wall/pole in existing or new location including brass compression cable glands, terminal lugs etc,including dismantling of old cable of any description complete all as specified and as directed. |
| 80 | Supply, laying and testing XLPE Insulated , PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 35 sqmm 3.5 core laid in trenches /floor or fixed on wall/pole in existing or new location including brass compression cable glands, terminal lugs etc,including dismantling of old cable of any description complete all as specified and as directed. |
| 81 | M&L for sand cushioning with dry river sand in trenches for cushioning of underground cable including spreading, leveling, punning down the thickness of sand upto 18cm and consolidated complete all as specified and as directed.Note: Punned thickness of sand cushioning will be measured and paid. |
| 82 | M&L for sub class ‘B’ old size well burnt brick laid flat in trenches with length of brick perpendicular to length of cable, over the cable forprotection of LT cable complete all as specified and as directed. |
| 83 | M& L for manual boring under roads/hard standing using required T&P without disturbing the top surface of the road, inserting GI pipe n exc 100 mm dia for cable protection complete all as specified and as directed. Note : - GI pipe will be measured & paid separately. |
| 84 | M & Lfor earthing in replacement complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers, galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cm X 5 cm with 10mm dia TMT bars 8 cm C/c both ways andone handle for lifting made out of 8 mm dia TMTbar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I including dismantling of old earthing complete all as specified and as directed. |