| 1 | M&L for attending day to daygeyser/water heater complaint by a qualified technician, including site inspection, diagnostic testing, and troubleshooting to identify faults such as heating element failure, thermostat malfunction, faulty wiring, or scale buildup. The scope of work covers the labor for minor repairs, cleaning of the inlet/outlet assembly, checking of safety valves, and verifying proper earthing and electrical connectivity to ensure safe and efficient operation. This service includes a post-repair performance test to confirm the water reaches the desired temperature without leakages or electrical hazards (replacement of major components like the heating tank, element, or thermostat to be charged extra as per actual requirements).Note: . 1.The spare parts required for repairs shall be measured and paid separately under respective item of this Schedule. 2. Contractor should submit the complaint slip at the time of RAR. |
| 2 | Taking down the geyser from its existing position for general cleaning/overhauling and descaling the tank and assembly with suitable detergent and making fully serviceableand refixing in new/old position complete with testing complete all as specified and as directed. Note: The spare parts required for repairs shall be measured and paid separately as \"Supply and Fix\" under respective item of this Schedule. |
| 3 | Supply and Fix in replacement fusible plug type (pressure valve) Air release valve complete all as specified and as directed. |
| 4 | Supply and Fix in replacement air release valve (Nozzle) as per sample complete all as specified and as directed. |
| 5 | Supply and Fix in replacement gasket of thickness 5 mm for geyser assembly of 06 holes/ 08 holes / 09 holes complete all as specified and as directed. |
| 6 | Supply and Fix in replacement Syphon assembly ofcopper, 06 holes with nut bolts/stud/washer complete all as specified and as directed. |
| 7 | Supply and Fixin replacement of indicating lamp green/ redfor geyserrectangular type/round type complete all as specified and as directed. |
| 8 | Supply and Fix in replacement inner shell of Geyser of cap 25 Litre made out of stainless steel tank complete all as specified and as directed. |
| 9 | Supply and Fix in replacement inner shell of Geyser of cap 35 Litre made out of stainless steel tank complete all as specified and as directed. |
| 10 | Supply and Fix in replacement inner shell of Geyser of cap 50 Litre made out of stainless steel tank complete all as specified and as directed. |
| 11 | Supply and Fix outer body of Geyser Capacity 25/ 35/ 50 Litre of 20 SWG MS Sheet and woolen glass duly painted complete all as specified & directed. |
| 12 | Supply and Fixingof five star rated Geysers white blue in colour capacity 25 Ltr, Electric Driven, Single phase, 240 V, Storage vertical type and heating element 2 KW, inner shell made up of stainless steel, automatic cutoff,manual tempreture setting , maintaining 8 bar pressue including electrical and water connection with hot and cold water connection pipe (PVC type) and fixed on the wall with mild steel fastner 150 mm long and 10 mm dia with pin and bolts complete all as specified and directed. Make : Havell\"s/ Crompton/ Bajaj. |
| 13 | Supply and Fix in replacement thermostat switch of geysers (adjustable type) temp range 35 Degree Celsius to 75 degree Celsius complete all as specified & directed.Make- THEETA/BAJAJ/RECOLD/DASPASS |
| 14 | Supply and Fix in replacement heating element 1.5 KW (round type) with rubber gasket complete all as specified & directed.Make- Theeta/Bajaj /Recold/ DASPASS (As per sample) |
| 15 | Supply and Fix in replacement heating element 2.0KW (round type) with rubber gasket complete all as specified & directed.Make- Theeta/Bajaj /Recold/ DASPASS (As per sample) |
| 16 | Supply and Fix in replacement heating element 1.5 (triangle type) with rubber gasket complete all as specified & directed.Make- Theeta/Bajaj /Recold/ DASPASS (As per sample) |
| 17 | Supply and Fix in replacement heating element 2.0 (triangle type) with rubber gasket complete all as specified & directed.Make- Theeta/Bajaj /Recold/ DASPASS (As per sample) |
| 18 | Supply and Fix in replacement 15mm size PVC connection pipe 600mm longheavy duty with brass nut for hot/cold water complete all as specified & directed. |
| 19 | Supply and Fix in replacement 15mm size PVC connection pipe 450mm longheavy duty with brass nut for hot/cold water complete all as specified & directed. |
| 20 | Supply and Fixin replacement brass chromium plated angle valve suitable for 15 mm bore pipe complete all as specified and as directed. |
| 21 | Supply and Fix in replacement 15mm size brass CP extension nipplecomplete all as specified & directed. |
| 22 | Supply and Fixin replacement15 mm size Brass CP Angle valve 2 in 1 complete all as specified & directed.Make-Zim/ Parko/Kingston) |
| 23 | Supply and Fix dash fastener mild steel 150 mm long x 10 mm dia with pin and bolts complete for hanging of geyser properly on wall and making good to the disturbed surfaces including plastering and white washing complete all as specified and as directed. |
| 24 | Taking down geyser from existing location, preparation of body of geyser by knotting and stopping of outer surface, repainting the complete outer surface of geyser with two coat of synthetic enamelled paint 1st qualityand refixing the same on wall in existing location and writing \"AGE E/M BHDC with Location\" of letter size 10 mm complete all as specified and as directed. |
| 25 | M&L for unscrewing the nut bolt and taking out the base plate geyser assembly andcopper tank making soldering and brazing of tank to stop the leakage of tank and fixing back in the positioncomplete all as specified & directed. |
| 26 | Supply and Fix in repair PVC insulated unsheathed copper wire of size 4 Sqmm 3 core complete all as specified & directed. |
| 27 | Supply and Fix in replacement Syphon assembly ofcopper, 09 holes with nut bolts/stud/washer complete all as specified and as directed. |
| 28 | Supply and Fix in replacement thermostat cut out of geysers (adjustable type) temp range 35 Degree Celsius to 75 degree Celsius complete all as specified & directed.Make- THEETA/BAJAJ/RECOLD/DASPASS |
| 29 | Supply and Fix in replacement of electrical backup 3 KW capacity heavy duty 18 Inch with thermostat for solar water heating system complete all as specified and directed. |
| 30 | Supply and Fix in replacement of solar toughened glass for solar water heating system complete all as specified and directed. |
| 31 | Supply and Fix in replacement of Air Vent for solar water heating system complete all as specified and directed. |
| 32 | Supply and Fix in replacement of MT for solar water heating system complete all as specified and directed. |
| 33 | Supply and Fix in replacement of Thermostat for solar water heating system complete all as specified and directed. |
| 34 | Supply and Fix in replacement of makeup tank for solar water heating system complete all as specified and directed. |
| 35 | Supply and Fix in replacement of Ball Cock for solar water heating system complete all as specified and directed. |
| 36 | Supply and Fix in replacement ofSOLAR PANEL EDPM Hose Pipe for solar water heating system complete all as specified and directed. |
| 37 | Supply and Fix in replacement ofGate Valve for solar water heating system complete all as specified and directed. |
| 38 | Supply and Fix in replacement of solar ETC tube for solar water heating system complete all as specified and directed. |
| 39 | Supply and Fix in replacement of solar collector brazzing for solar water heating system complete all as specified and directed. |
| 40 | Supply and Fix in replacement of EPDM Gasket for solar water heating system complete all as specified and directed. |
| 41 | Supply and Fix in replacement of solar descaling for solar water heating system complete all as specified and directed.Make for BOQ item No 29 to 41 : Tata Solar/ V-Guard/ Intra Solar |
| 42 | M&L for servicing of solar water heating system of any capacity including cleanning, checking all loose electrical connection, water connection complete all as specified and directed. |
| 43 | Supply and Fixing in replacement LED Strip light for perfect ambiance to use indoor having lumen output of 800 lumen protected with IP 65 complete having 120 LED per meter complete with output short circuit protection, surge voltage protection up to 2.5 KV in warm white(3000 K), Power factor greater than 0.9 , CRI (Ra) greater than 80, System with average life of 50000 burning hours complete flexible slim and compact applicable for bendable and agled pattern or in continous row complete all as specified and as directed. Supply and Fixing LED Strip isolated electronic driver complete all as specified and as directed.Design, supply , fabrication and fixing of sinage board (120 inch X 42 inch ) size using words made of acrylic cutout letters and reflective vinayal sheet same as the existing one all as specified and directed by engg-in-charge.1.Board shall be fabricated with 3mm thick ACP sheet in shining black colour.Powder coated Aluminium sheet shall be fixed from the rear side of the entire board to make box section.2.Logo letters(English) shall be made of Acrylic cutout letter and shall be uniformaly illuminated by LED light. Font of letter is same as the existing one with font size of 27 inch.3.Powder coated aluminium clips and brackets shall be used of minimum 3 mm thickness as per direction of Engineer - in - charge.4.Word of signage board shall be fixed using reflective vinayl cutout letter. |
| 44 | Supply and fix surface mounted Bed head panel for patient bed duly powder coated finish, aluminium extruded (aluminium grade 6063/T-6, Profile HP-4E, complete with medical gas outlet , provision of 6 Nos of 15 Amp socket with switch , Provision of nursing call bell, complete with down side patient bed LED Light of size 1200 x 200 x 65 mm complete in all aspect all as specified and as directed. |
| 45 | Supply, installation, testing, and commissioning of the Havells Hestio Oscillating Quartz Heat Pillar, featuring high-quality quartz heating elements for instant and efficient radiant heating. The unit shall include a motorized oscillation function for multi-directional heat distribution, a cool-touch integrated handle for portability, and a robust safety grill. The scope of work includes connecting the unit to the existing electrical point using the manufacturer-provided cord and plug, verifying the tip-over safety switch and overheat protection functionality, and ensuring stable floor placement complete in all aspect all as specified and as directed.Havells Hestio/Usha 4311 FSE/Bajaj Majesty - RH9F Plus. |
| 46 | Supply and fix in replacement heat convector of 2000 watt capacity ccomplete in all aspect all as specified and as direced. Havells/crompton/Bajaj |
| 47 | Supply, fixing, testing & Commissioning in repair outdoor type, area wall illumination lighting, 20-30W LED FIXTURE, RGBW (4in1 LED) (DMX 512 Compatible), IP 66 rated,consisting of light weight housing, made of high strength aluminium and coated by static powder, weather resistant, Protection screen in ultra white tempered glass with high impact resistance (=>IK08), High precision dial to ensures precision angle adjustment, Pure Polyester powder coating in Standard Grey Colour, Precise structure and multi-protection silicon rubber seal,Length-1000mm, Height – 66mm, Width.-64mm, Weight - 4Kgs, Power LED Module with high efficacy LED\"s, on Printed Circuit Board with metal core plate, Electronic Power Supply for LED Module, for Protection against Short Circuit, Over- Voltage& Over- Current, with in-built surge protection. Light fixture shall be standard DMX512 protocol compatible, the DMX decoder function shallbe inbuilt the light fixture, Each light fixture shall be individually addressable & shall be able to operate with any standard DMX512 equipment. Lens shall be made of PC which shall offer 3 different beam angles 12deg./35deg./25deg.x45deg. to serve different lighting needs. Estimated LED Lifetime is L70-50,000 hours minimum.LM80 report from LED Manufacturer should be submitted at the time bid submission. BIS Safety test report as per IS10322 from 3rd party NABL lab should be submitted at the time bid submission. BIS Certificate with manufacturer same as brand and manufacturer address of indian origin should be submitted at the time bid submission. Minimum Light fixture Lumen output is 1400Lumens. OEM Authorization to contractor should be submitted. Sample Should be submitted for concerned engineer incharge for approval of light fixture.Orient Electric/ GVA Lighting/ Lumen PluseNote : The Testing shall be carried in persence of rep of OEM and contractor. |
| 48 | Supply, fixing, testing and Commissioning in replacement outdoor type, wall illumination lighting LED FIXTURE 25-35W,LED,3000k,IP 66 Light, consisting oflight weight housing made of high strength die cast aluminium and coated by static powder, to make it weather resistant, protection screen in ultra white tempered glass with high impact resistance. High precision dial to ensures precision angle adjustment. Premium thermal management by high heat conductivity aluminium alloy and thermal fins. Pure Polyester powder coating in Standard Grey Colour. Precise structure and multi-protection silicon rubber seal guarantees the fixture IP66 rated. Height – 176mm, Dia.-170mm, Weight - 2.0Kgs Power LED Module with high efficacy LED\"s, on Printed Circuit Board with metal core plate. CRI > 80(for white),P.F>0.9,voltage input AC100-277V,50/60Hz. In-Built Electronic Power Supply for LED Module, to ensure Protection against Short Circuit, Over- Voltage& Over- Current, with in-built surge protection. Lens shall be made of PC. Estimated LED Lifetime is L70-50,000 hours minimum.LM80 report from LED Manufacturer should be submitted at the time bid submission. BIS Safety test report as per IS10322 from 3rd party NABL lab should be submitted at the time bid submission. BIS Certificate with manufacturer same as brand and manufacturer address of indian origin should be submitted at the time bid submission. Minimum Light fixture Lumen output is 2400Lumens. OEM Authorization to contractor should be submitted. Sample Should be submitted for concerned engineer incharge for approval of light fixture. complete all as specified and as directed. Make:NERI 45-60 W, LED, 3000k, IP 66 or equivalent in GVA lighting/ Lumen Pluse. |
| 49 | Supply ,Installtion,Testing and commissioning in replacement of architectural post top lantern,havingupper square frame made in die cast aluminum, auxiliary and optical compartment can be accessed by tilting the top frame, Bottom frame made in die cast aluminum with four-armed bracket with flange and a hole (Ø 28 mm) for attachment to the support The Screen made in polymethylmethacrylate (PMMA) molded in a single piece with high impact resistancecapable of withstanding1 Joules of impact energy Equivalent to impact of 0.25 kg mass from a 400 mm drop above finished floor level IK06. The operating temperature range of the light fixture shall be from 0°C to +50°C. Pure polyester powder coating in Standard NERI Grey Colour.The luminaire shall conform to an IP66 ingress protection rating as per IEC 60529, ensuring complete protection against dust particulates and protection against high-pressure water jets from any direction with no ingress of dust and no harmful effects from water projected by a 12.5 mm nozzle at a flow rate of 100 liters per minute and pressure of 100 kPa at a distance of 3 meters. Height – 605mm, Length - 325mm, Width - 325mm,Weight -5.5Kgs., Area Exposed to Wind(S) - 0.065 m2Power LED Module with Company /brand name printed on PCB with the metal core plate. LED chips of CREE/NICHIA/OSRAM/LUMILED make shall be used. Colour Rendering Index: Ra > 70.Electronic Power Supply for LED Module, which offers Protection against Short Circuit, Over- Voltage& Over- Current, with in-built surge protection (an additional surge protection device of 10kV also provided in-built the fixture). Optics with refractive lens in PMMA/PC . system wattage of 50W with system lumen of 6000lm & system efficacy of 120lm/watt, CCT: 3000K, CRI>70, LED Lifetime >1,00,000hours. LM80 report from LED Manufacturer should be submitted.Safety test report as per IEC 60598/IS 10322 from UL/UL Authorised/3rd party NABL should be submitted. Products shall be in compliance with IEC 62031, and IEC/TR 62778. LM79 report also should be submitted from UL/UL Authorised/3rd party NABL Laboratory. BIS Certificate with manufacturer name same as brand proposed should be submitted. Sample should be submitted for approval from concerned engineer-in charge.Make: Neri-Light 851-45-55W Power Module LED 3000K upright /DW Windsor /GHM |
| 50 | Supply,Installtion,testing and commissioning in replacement 3M high post-top grooved pole made ofsteel pipe section of 89mm diameter, complete with two brackets of 400mm length each (Mounted on Pole at the height of 2.6M), fabricated from steel pipe sections. Decorative Base in Steel - Its design starting with dia 260mm for 170mm height, then tapers to 180mm, followed by a cylindrical section of 165mm dia., 365mm Height. It ends with a Top section consist of a Ring of 205mm dia. and 40mm height followed by a taperinng section with Bottom dia. 175mm, Top dia 105mm and Height of 90mm. Total Height of the Base is 700mm. A Steel base plate of 300mm x 300mm is welded at the bottom of the base.additional brakcetThis base plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed RCC foundation. Decorative cast iron flower starting with a dia 102 mm increasing gradually to 160mm and then tapering to a dia 99mm.Total height of cast iron flower is 304 mm & weight is 6.3kgs. Top Ring-(weight- 3kgs.) made of cast iron. All cast iron parts weight mentioned are with +/- 5% tolerance. Entire pole including the decorative elements shall be made to provide pleasing aesthetics as approved by Architect/ Engineer in-charge. After Fabrication, Entire Pole should be shot blasted for the effective adhesion of 3layer coating so as to avoid the corrosion. The pole should be provided with an inbuilt junction box with 1No. 32A Heavy Duty Stud type connector and 1No. 6A SP MCB, at the bottom- the inbuilt box should have a flush door of suitable size. Wind pressure calculation as per IS 875(part-3) & structural calculation report as per EN40 should be submitted to verify the pole strength. Pole & Cast iron parts are painted in 3 layer coating(coating thickness-100 microns minimum) in which 1st layer with etch primer, 2nd layer with epoxy primer & 3rd final layer with PU paint. Sample should be submitted for approval from engineer-in-charge The quoted rate must include the necessary civil work to make foundation for pole installation as per normscomplete(nothing extra in that respect paid to the contractor) in all aspect all as specified and as directed. Make: Neri /DW Windsor /GHM |
| 51 | Supply, installation, testing, and commissioning of 25 sq.mm 3.5-core aluminum armored UG (Underground) XLPE/PVC insulated cable, including all necessary civil works such as excavation of trenches to the required depth (typically 750mm to 900mm), providing a 75mm sand cushioning layer, laying of protective burnt bricks or stone tiles over the cable length, backfilling with excavated soil, and thorough ramming to restore the surface to its original condition. The scope includes all required cable glands, lugs, termination kits, and jointing materials to ensure a complete and functional installation in accordance with standard electrical specifications and safety codes complete in all aspect all as specified and as directed. |