| 1 | Supply ,Installing ,testing and commissioning, factory made and tested,CPRI approved LT panel board out doortype,weather,vermin proof, mounted on plateform with angle iron legof size 50x50x 6 mm thick,suitable for 440 volts,3 phase 4 wire 50HZ AC supply system, conforming to IS-5039,made of 3 mm thick CRCA sheet with Bottom \"C\" Chanel 75 mm with cable chamber size of panel 1400x900x450 mm and aluminium bus bar 1.5 times of rated current of incoming MCCB with heat shrink insulation and mounting insulators,angle iron frame work of size 50x50x6 mm thick ,ventilation arrangement, powder coated paint of approved colour over a coat of red oxide primer complete all as specified and directed including the following:-MCCB 4 pole, 250 Amps, 35KA, 415 volts-01 No (Incoming) , MCCB 4 pole, 100Amps, 25 KA, 415 volts-01 No (Outgoing) , MCCB 4 pole 32 Amps 25 KA- 05 Nos, Indicator lamp R,Y, B LED type -01 Set, MCB SP 6-32 Amps - 03 Nos for control wiring protection,Digital type Ammeter with suitable rating CTs -01 Nos(g) Volt meter digital type - 01 Nos |
| 2 | Supply only 5 KVAr capacitor duty contactors with built in surge suppressor and NO/NC. Make : L&T, Havells, Schneider, Legrand |
| 3 | Supply only 10 KVAr capacitor duty contactors with built in surge suppressor and NO/NC.Make : L &T, Havells, Schneider, Legrand |
| 4 | Supply only 15 KVAr capacitor duty contactors with built in surge suppressor and NO/NC. Make : L&T, Havells, Schneider, Legrand |
| 5 | Supply only 25 KVAr capacitor duty contactors with built in surge suppressor and NO/NC.Make : L&T, Havells, Schneider, Legrand |
| 6 | Supply only 50 KVAr capacitor duty contactors with built in surge suppressor and NO/NC .Make : L&T, Havells, Schneider, Legrand Note -Sl NO 2 to 5 The contactor frame size suitzble to mount existing capaciter panel |
| 7 | Supply only 25 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection. Make : L&T, HPL, Havells, Schneider, C&S |
| 8 | Supply only 10 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection. Make : L&T, HPL, Havells, Schneider, C&S |
| 9 | Supply only 5 KVAR heavy duty cylindrical capacitor Rated Voltage 440V AC, 3ø, 50Hz, Delta Connection. Make : L&T, HPL, Havells, Schneider, C&S |
| 10 | Supply and fixMCCB four pole 250A 36 KA 415 V, adjustable type suitable to existing framewith spider terminal link including taking down unserviceable MCCB,s all as directed.Make: C&S /Siements/Indo asian/Havells /Schnieder |
| 11 | Supply and fix in repair digital type voltage & amp meter 415 Volts, 3 Phase including connection, seting a ammeter asper exsisting CT ration and taking down unserviceable meter all as directed. MakeL&T, Havells, Sicco, AE, Elmeasure |
| 12 | Supply and fix butterfly valve 80 mm dia with necessary nut bolts washer, gaskets including taking down unserviceable valve in any situation/height, necessary welding/cutting where required and making good the surface with existing finish all as directed |
| 13 | Aall as per item No 12 above but 65 mm dia butterfly valve complete |
| 14 | cutting chases, pinning in, making good to facings where required and pointing in cement motor 1:3 to ends or edge of landings, steps, cillls sunset sleeves lintels, etc and cutting changes for concrete water tubing or concealed conduit wiring etc and making goods cutting not exceed 10 cm girth |
| 15 | M&L for concealed Sub main wiring by making recess in wall/surface complete with 4 runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including suitable dia non metallic rigid PVC conduit and conduit accessories suface/concealed in wall/Ceiling etcfrom Main DB to MCB DB all as specified and as directed by engr - in- charge. Note :- 4 runs of 6 sqmm, + 1 run of 6 sqmm (Earth Cotinuity conductor) and 1 run of PVC conduit shall be measured as one unit length. |
| 16 | All as per Item No 15 above but 4 run of 25 sq mm |
| 17 | Supply end Fixpower contacter 200 Amp, 4 pole 450 Volt three phase type mcx are equalent Confirms to IEC 60947-4-1 operating voltage Of Coil 230 Volt with 2 No + 2 NC with necessary Control wiring Suitable to excisting pannel any type |
| 18 | Supply end Fixpower contacter 160 Amp, 4 pole 450 Volt three phase type mcx are equalent Confirms to IEC 60947-4-1 operating voltage Of Coil 230 Volt with 2 No + 2 NC with necessary Control wiring Suitable to excisting pannel any type |
| 19 | Supply end Fixpower contacter 100 Amp, 4 pole 450 Volt three phase type mcx are equalent Confirms to IEC 60947-4-1 operating voltage Of Coil 230 Volt with 2 No + 2 NC with necessary Control wiring Suitable to excisting pannel any type |
| 20 | Supply and Fix Control relay Auxiliary/main Contactor Suitable to operate Ac 415 volt to 240 Volt operating Coil Voltage 240 Volt with 2NO + 2 NC of Capacity 20 to 30 Amp |
| 21 | Supply and fix MCCB Spreader linked kit Set of 4 of Capacity 250 to 300 Amp |
| 22 | Supply and fix MCCB Spreader linked kit Set of 4 of Capacity 100 to 200 Amp |