| Sl. No. | Item Description |
| 1 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, etc. complete all as specified and directed. |
| 2 | Dismantling Asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings complete all as specified and directed. |
| 3 | Dismantling timber scantlings 40 Sqcm and over in any position in framed work complete all as specified and directed. |
| 4 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 5 | S&F Joist, channel, angle, or tee sections, fixed independently without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to Fe-290 (Gde E-165) complete all as specified and directed. |
| 6 | M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 or other cuting plates complete all as specified and directed. |
| 7 | S&F Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 8 | All as per above item No. 7.00 here-in-before but except sheeting complete all as specified and directed. |
| 9 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 10 | M&L 6 mm thick asbestos cement, corrugated or semi corrugated sheets in roof, walls etc fixed with L-T type or J-type or cranked hook bolts etc. complete all as specified and directed. |
| 11 | All as per above item No. 10.00 here-in-before butt exept sheet |
| 12 | M & L Asbestos cement two piece adjustable plain wing ridge 6 mm thick fixed with \"J\" type hook bolts etc. complete all as specified and directed. |
| 13 | M&L 2nd class hard wood scantling clean sawn, timber fixed for purlins, posts, rafters etc. complete all as specified and directed. |
| 14 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness including cover fillets complete all as specified and directed. |
| 15 | M&L for providing aluminium snap Grid frame work for false ceiling with of size 605X605 mm, using main and cross tee of size 36.5mmX25mmX1.4mm, weighing 0.24 kg/RM and 23.5mmX26.4mmX1.4mm weighing 0.191Kg/RM respectively. The snap grid shall be supported at end all along the wall with aluminium anodised angle of size 40mmX25mmX2mm weighing 0.36Kg/RM. The snap grid shall be fixed to ceiling supporting hangers consisting of 2mm dia MS wire/GI wire, J bolts, nuts and washers as per manufacturer\"s instruction complete all as specified and directed. |
| 16 | M&L for 4 mm thick non Asbestos fibre cement designer building boards, fixed or laid/inserted totimber/GI/Aluminium framework with screws complete all as specified and directed |
| 17 | Dismantling boarding, any description, fixed in any position with nail complete all as specified and directed. |
| 18 | M&L for second class hardwood Weather boarding, clean sawn, plain, 20mm thick or feather edged 15 mm to 20mm thick and fixed with 30mm laps complete all as specified and directed. |
| 19 | Fixing only second class hardwood Weather boarding, clean sawn, plain, 20mm thick or feather edged 15 mm to 20mm thick and fixed with 30mm laps complete all as specified and directed. |
| 20 | M&L preparing new surfaces of wood of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 21 | Demolition of brick work in cement mortar incl all quions, arches, pillers etc. but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and directed. |
| 22 | M&L brick work with sub class \"B\" bricks straight or curved on plan exceeding 6 M mean radius built in CM 1:4 complete all as specified and directed. |
| 23 | All as per item No. 22.00 above but except bricks. |
| 24 | M&L brick work with sub class \"B\" brick straight or curved on plan exceeding 6m means radius build in cement mortar 1:6 complete all as specified and directed. |
| 25 | Taking down cement plaster on brick or stone wall etc. including raking out joints hacking for keys scrubbing down with water etc. complete all as specified and directed. |
| 26 | M&L for 15 mm thick rendering in CM 1:4 on the fair faces of brickwork or concrete surfaces complete all as specified and directed. |
| 27 | M&L for preparation of newly plastered wall surfaces and applying three coat of white wash complete all as specified and directed. |
| 28 | Demolition of plain cement concrete in ground floor and paving not exceeding 15cm thickness below or above ground level complete all as specified and directed. |
| 29 | M&L for providing cemnet concrete (1:2:4) type B1 using 20 mm graded stone aggregate as in coping, surface channnel of drains, bed plates including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 30 | M&L for (PCC 1:4:8) type D2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed. |
| 31 | M&L for cement concrete 75 mm thick 1:3:6 Type C2 using 20 mm graded aggregate as in plinth protection/path making even & smooth with using extra cement complete all as specified and directed. |
| 32 | Dismantling of stone slabs & tiles of any description or thickness (except ceramic tiles) in floors, aprons etc. laid bedded & pointed in any mortar complete all as specified and directed. |
| 33 | M&L Cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in levelling course, flooring / hardstanding, coping, window cilletc. complete all as specified and directed. |
| 34 | M/L for Screed bed or bedding layer of cement mortar 15 mm thick for laying floors finishes in cement mortar 1:4 complete all as specified and directed. |
| 35 | M/L for pre-polished Chequered cement concrete tiles 20cmX20cmX25mm thick set, jointed and pointed in neat cement slurry in floors with grey cement and pigment complete all as specified and directed. |
| 36 | M&L for Hardcore of broken stone boulder ofgauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 37 | Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed |
| 38 | M&L for Machine pressed precast conctete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed. |
| 39 | All as per item No. 38.00 above but except paver blocks. |
| 40 | Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed. |
| 41 | S/F MS steel post struts fencing post including cutting top to shape, drilling holes notching for wire etc. including all necessary drilling bolting andd similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 42 | S&F in repair galvanized two stranded steel barbed wire 2.24 mm dia barbed with 2mm dia berb at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanized mild steel wire, staple or steel pins etc. complete all as specified and directed. Note : Each line wire to be measured. |
| 43 | Fixing only in repair of galvanized two stranded steel barbed wire 2.24 mm dia barbed with 2mm dia berb at 75 mm spacing and straining and fixing to any type of standard rails straining bolts complete all as specified and directed. Note : Each line wire to be measured. |
| 44 | Dismantling fencing wiremesh any type |
| 45 | Supply only chain link MS galvanised fencing, any size or type |
| 46 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standrad , rails, straining bolts, etc. including provision of binding wire complete all as specified and directed. |
| 47 | S&F framed work such as grills, grating, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed. |
| 48 | M&L for two coats of synthetic enamel paint over a coat of red oxide primer on newly untreated surfaces of steel over 10cm in width or girth not otherwise described complete all as specified and directed. |
| 49 | M&L for preparation of newly plasteredwall surfaces applying two coat of acrylic smooth exterior paint of required shade(camouflage) applied @1.67 litre/10Sqm over and including priming coat of exterior primer applied @2.20kg/10sqm complete all as per manufacturer instruction & directed. |
| 50 | Demolition of Cement concrete (unreinforced) of any description and in any position, surface channels not otherwise specifically provided for complete all as specified and directed. |
| 51 | M&L for 100 MMthick PCC 1:2:4 type B-1 using 20 mm graded aggregate as in floor/hardstandings complete all as specified and directed. |
| 52 | M&L 75mm thick cement concrete 1:4:8 type D2(using 40 mm graded stone aggregate) in footpath and passage complete all as specified and directed. |
| 53 | Taking down unserviceable rolling shutters/sliding gates for repairing necessary greasing and replacement of UNSV portion like anchoring road, ball bearing, shutter etc. and re-fixing same openingcomplete all as specified and directed. Note :- Spare parts required shall be measured and paid for separately under relevant item as Supply only. |
| 54 | M&L mild steel round bars Fe 410-W (Gde-E- 250) quality-A, in available lengths complete all as specified and directed. |
| 55 | Supply only Ball bearing for rolling shutter complete all as specified and directed. |
| 56 | S&F steel rolling shutters of 1.25 mm thick without ball bearing as specified including top cover, anchoring rod, hasp & staple and one shop coat of primer, erected in position as indicated push pull or manual type complete all as specified and directed. |
| 57 | S&F safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed. |
| 58 | S&F Welded steel wire fabric not exceeding 4 Kg/Sqm fixed to wood or steel members complete all as specified and directed. |
| 59 | S&F Mild steel, corrugated, blacksheet, 1.25 mm thick in wall cladding,steel gates and similar work, cut to size, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed. |
| 60 | S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachement conforming to Fe-290 (Grade E-165) complete all as specified and directed. |
| 61 | Taking down chowkhats or frames not exceeding 1.5 Sqm each with shutter (without taking of shutters from the frames) complete all as specified and directed. |
| 62 | Taking down chowkhats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each with shutter (without taking of shutters from the frames) complete all as specified and directed. |
| 63 | S&F for 2nd hard wood for plain solid straight chowkats & frame wrought framed related on the solid rounded or chamfered, put together with glue pined at joints complete all as specified and directed. |
| 64 | S&F 35mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on the both side complete all as specified and directed. |
| 65 | S&F 30mm thick glazed and skelten shutter open rebated and prerepair to receive glass, gauge etc. without sash bars, edge of framing, plain/chamfered or rounded, fitted with cut and metered beads with first 2nd class hard wood complete all as specified and directed. |
| 66 | S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain coloured PVC sheet reinforced with MS square tube Supplying & Fixingin openingas per specification and drawing, including making good (such as rendering and white wash matching to exixting surface) to the existing surfaces complete all as specified and directed. |
| 67 | S&F factory made soild panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & plain colour PVC sheets for top rail,lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification and drawing shown on page -156 of MES SSR Pt-II complete all as specified and directed |
| 68 | S&F aluminium anodised barrel tower bolt of extruded section 150 mm long complete all as specified and directed. |
| 69 | S&F aluminium anodised barrel tower bolt of extruded section 125 mm long complete all as specified and directed. |
| 70 | S/F Aluminium alloy, anodised, sliding door bolt 250 mm length with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. |
| 71 | S & F 100mm stainless steel butt hinges |
| 72 | S & F 75mm stainless steel butt hinges |
| 73 | S&F 150 mm aluminium alloy handels cast/plate type |
| 74 | S&F 125 mm aluminium alloy handels cast/plate type |
| 75 | S&F 3 mm thick Sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and directed. |
| 76 | S&F Anodised aluminum snap grid frame work main Tee size 25.4x25.0x1.63 mm supported at ends with 38.1x25.4x1.32mm forming grid 600x600 mm for false ceiling suspended with 6mm GI wire,(upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleat made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified and directed. |
| 77 | M&L providing and fixing gypsum board 10mm thick in ceiling fixed with screws as per manufacturer instruction complete all as specified and directed. |
| 78 | M&L for preparation of newceiling surfaces applying two coat of oil bound distemper over a coat of aikali resistance primer complete all as specified and directed. |
| 79 | M&L point wiringfor light points / ceiling fan points / exhaust fan points/ call bell points controlled by one 5/6 Amps switch with 1.5 sqmm single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including PVC conduit of size 25mm and accessories on wall / ceiling surfaces etc. with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed,FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories including taking down old unsv point wiring complete all as specified and directed. |
| 80 | All as per item No. 80.00 above but for one 5/6 Amps socket outlet point on the same board. |
| 81 | All as per item No. 80.00 above but for one 5/6 Amps socket outlet on independent board. |
| 82 | All as per item No. 80.00 above but for one socket outlet 15 Amp on independent board with 2.5 Sq.mm cable and 2.5 Sq.mm earth wire. |
| 83 | M&L submain wiring for light point controlling with one MCB/switch using FRLS, PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 2.5 Sqmm, earth continuity conductor of size 2.5 Sqmm to be drawn through and including PVC conduit 20/25mm with including taking down old unsv one point complete all as specified and as directed.Note :- (i)Two single core wires of 2.5 Sqmm and one wire of 2.5 Sqmm and one run of PVC conduit shall be measured as one unit). (ii)The unit rate shall be deemed to be included with cutting chases and making good the disturbed surfaces to match with the adjoining surfaces. |
| 84 | All as per item No. 84.00 above but for DB to DB/AC connection with 2 Single core of size 4 Sqmm and earth continuity conductor of size 4 Sqmm. |
| 85 | M&L point wiringfor light points / ceiling fan points / exhaust fan points/ call bell points controlled by one 5 / 6 Amps switch with 1.5 sqmm single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including PVC casing caping (double lock pattern) and accessories on wall / ceiling surfaces etc. with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed,FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel terminal boxes 60 mm deep, on walls with 3 mm thick plastic laminated / hylam sheet cover, fixed on wall / other surfaces with brass screws for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessoriesincluding taking down old unsv point wiringcomplete all as specified and directed. |
| 86 | All as per item No. 86.00 above but for one 5/6 Amps socket outlet point on the same board. |
| 87 | All as per item No. 86.00 above but for one 5/6 Amps socket point on independent board. |
| 88 | All as per item No. 86.00 above but for one socket outlet 15 amp on independent board with 2.5 Sq.mm cable and 2.5 Sq.mm earth wire. |
| 89 | M&L submain for light point controlling with one MCB/switch using FRLS, PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 2.5 Sqmm, earth continuity conductor of size 2.5 Sqmm to be drawn through and including PVC casing caping withincluding taking down complete all as specified and directed.Note :- (i)Two single core wires of 2.5 Sqmm and one wire of 2.5 Sqmm and one run of PVC conduit shall be measured as one unit). (ii)The unit rate shall be deemed to be included with cutting chases and making good the disturbed surfaces to match with the adjoining surfaces. |
| 90 | All as per item No. 90.00 above but for DB to DB/AC connection 2 Single core of size 4 Sqmm and earth continuity conductor of size 4 Sqmm. |
| 91 | S & F Switch piano 5 Amps single pole one wayincluing taking down old unsv ones complete all as specified and directed. |
| 92 | S & F Switch piano 5 Amps single pole bell push incluing taking down old unsv ones complete all as specified and directed. |
| 93 | S & F Socket outlet 5 Amps 3 pin flush typeincluing taking down old unsv ones complete all as specified and directed. |
| 94 | S & F Switch Socket combination 5 Amps 3 pin flush type incluing taking down old unsv ones complete all as specified and directed. |
| 95 | S & F Switch Socket combination 16 Amps 3 pin flush type incluing taking down old unsv ones complete all as specified and directed. |
| 96 | S & F Steppedtype fan regulator flush type incluing taking down old unsv ones ccomplete all as specified and directed. |
| 97 | S&F ceiling rose, 3 phase /PVC/ polycarbonate isolated bodyincluing taking down old unsv ones complete all as specified and directed. |
| 98 | S &F Bell buzzer, Ding Dong AC. 230 volts, single poleincluing taking down old unsv ones complete all as specified and directed. |
| 99 | S&F Lamp holder, PVC/ polycarbonate type with cord grip cap suitable for pendate fittings including taking down old unsv ones complete all as specified and as directed. |
| 100 | S&F in repairs LED bulb of Lamp wattage 12 Watts, withefficacy - not less than 100 Lm/Wattincluding taking down old unsv ones complete all as specified and directed. |
| 101 | S & F in repair of ultra slim square profile LED batten 20 watt 4ft long with extruded polycarbonate housing, environmental friendly, energy efficient ready to use pack & integrated Electronic Driver with IP20, PF 0.90, total System Lumens 1050 Lumens, 6500k CRI ≥ 80, Operating Voltage range 140 V - 270 V complete all as specified and directed. |
| 102 | S&F in repair Recessed Mounted Square (2\"x2\") LED Panel light 36 watt with CRCA powder coated housing & high transmittance Opal diffuser for glare free with Electronic LED Driver. IP20, PF ≥0.95, System Lumens ≥100 lm/W, 5700k CRI ≥ 80, Operating Voltage range 140 V - 270 V complete all as specified and directed. |
| 103 | S&F MCB, SPN DB, 8 ways double door,Metal door, IP-43 IK 09 in 100A rated bus bars, earth bar, neutral links complete including blanking plates as required & fixed flush to wall and making good the disturbed surfaces including dismentling taking down unsv one complete all as specified & directed. |
| 104 | S&F MCB, SPN DB, 12 ways double door, Metal door, IP-43 IK 09 in 100A rated bus bars, earth bar, neutral links complete including blanking plates as required & fixed flush to wall and making good the disturbed surfaces including dismentling takingdown unsv one complete all as specified & directed. |
| 105 | S&F MCB SPN 6-32 Amps 240V, 50 Hz, breaking capacity 10 KA,\" C \" series including dismentling taking down unsvericeable one complete all as specified and directed. |
| 106 | S&F MCB SP, 10KA, 230V, C-curve, 6-32 amps including dismentling taking down unsv one complete all as specified and directed. |
| 107 | Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized iron earth lead wire of 4 sqmmby means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion including dismentaling old unsv ones complete all as specified & directed. |
| 108 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sq mm 3.5 core including taking down old unsv one and sand cushioning complete all as specified and directed. |
| 109 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core including taking down old unsv one and sand cushioning complete all as specified and directed. |
| 110 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sq mm 3.5 core including taking down old unsv one and sand cushioning complete all as specified and directed. |
| 111 | Excavation in trenches, in any type of soil not exceeding 1.5m wide or 10 Sqm on plane and not exceeding 1.5m in depth for foundation, Pole, shafts, cesspits, manholes, pier holes, laying of UG cables etc. and getting out in any type of soil complete all as specified and directed. |
| 112 | Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed. |
| 113 | Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 114 | Supply and laying well burnt sub class \"B\" old size bricks, laid flat dry, in trenches with width of the bricks laid to the axis of cable for cable protection complete all as specified and directed. |
| 115 | S&F junction box with SPN MCB fixed to electric pole with MS clamps fabricated out ofMS flat iron of size 25X5mm bend to shape cold or hot incl nut, bolts and 02 nos washers inlcuding painting of MS clamps with 02 coats of aluminium paint over a coat of red oxide primer including takingdown old unsv one complete all as specified and directed. |
| 116 | M&L for increase of height of existing LT panel upto 3 feet From GL by Providing PCC foundation after disconnecting all electrical connection, earthing connection and demolishing existing PCC foundation and refixing all electrical & earthing connection including testing complete all as specified and directed. |
| 117 | Taking down existing transformer of cap 250 KVA from existing platform with the help of crane by disconnecting all electrical connection, earthing connection etc. and reinstall the same at increased height new platform with the help of crane and reconnecting all electrical connection and earthing connection including testing the transformer in existing electrical load complete all as specified and directed. Note : Any damage occured in transformer due to negligence in handling during shifting will be rectified and total rectification cost will be borned the contractor. |
| 118 | Taking down existing servo voltage stabilizer of cap 200 KVA from existing platform with the help of crane by disconnecting all electrical connection, earthing connection etc and reinstall the same at increased height new platform with the help of crane and reconnecting all electrical connection and earthing connection incl testing the servo voltage stabilizer in existing electrical load complete all as specified and directed.Note : Any damage occured in servo voltage stabilizer due to negligence in handling during shifting will be rectified and total rectification cost will be borned the contractor. |
| 119 | Earthing complete with galvanised steel earth plate electrode 60cm x60cm x6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the galvanised iron earth lead strip of size 32x6mm, by means of nuts, bolts,check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe light grade 40mm bore light grade from earthing test point or main controling switch as directed including providing funnel with 20mm bore GI pipe light grade, wire mesh, charcoal or coke andcommon salt in alternative layer of 15 cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 50mm thick cover of RCC (1:2:4) (re-inforced with 8mm dia TMT bar @15 cm C/C bothways and MS bar handle made of 10mm dia bar) including necessary earth work in excavation, returning in and removal of surplus soil to a distance not exceeding 50mtr, all as per electrical plate No 3 of MES Schedule Part-I including earthing pit cover etc. including taking down old unsv one complete all as specified and directed. |
| 120 | Earthing complete with copper earth plate electrode 60cm x60cm x3mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the copper earth lead strip of size 20X3mm, by means of nuts, bolts,check nuts and washer etc of brass and earth lead protected by provision of GI pipe light grade 40mm bore light grade from earthing test point or main controling switch as directed including providing funnel with 20mm bore GI pipe light grade, wire mesh, charcoal or coke andcommon salt in alternative layer of 15 cm (compactedd thickness) all round the earth electrode, concrete earth pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 50mm thick cover of RCC (1:2:4) (re-inforced with 8mm dia TMT bar @15 cm C/C bothways and MS bar handle made of 10mm dia bar) including necessary earth work in excavation, returning in and removal of surplus soil to a distance not exceeding 50mtr, all as per electrical plate No 3 of MES Schedule Part-I including earthing pit cover etc. including taking down old unsv one complete all as specified and directed. |
| 121 | M&L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure. |
| 122 | S & F LED water proof light 12V/18 watt with SS body - 10 Nos and controller12 V/ 10 Amps - 01 Nos with electrical connection including taking out old UNSV one complete all as specified and directed. |
| 123 | Taking out old damaged GI pipe including nozzle and segregating serviceable nozzles & S&F GI pipe medium grade bend to shape drilling holes for fixing socket and nozzle including nozzles, gate valve- 01 Nos etc. and testing on completion complete all as specified and as directed. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy