| Sl. No. | Item Description |
| 1 | Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole, laying of cables, pipes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soil complete all as specified and as directed.Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding. |
| 2 | Removing excavated spoil to a distance not exc.50m and depositing where directed at alevel not exc. 1.5 m above the starting point complete all as specified and as directed. |
| 3 | M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in bed concrete for foundation filling & mass concrete complete all as specified. |
| 4 | M&L for Hardcore using broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified. |
| 5 | M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed. |
| 6 | M & L for RCC 1:1.5:3 type A1 (20 mm graded crushed stone aggregate) nominal mix as in foundations, including rafts, footings, foundation beams, plinth beams; bases for columns, etc. and mass concrete etc complete all as directed. |
| 7 | Material and labour for mild steel TMT bar 10mm dia over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooping end binding with mild steel wire not less than 0.9 mm all as specified. |
| 8 | S&F TMT reinforcement bar, conforming to Fe-500, 5mm dia and upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends as binding with and including mild steel wire (Annealed) not less than 0.9mm dia or securing with clips all as specified. |
| 9 | M & L brickwork with fly ash old sized bricks, straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified. |
| 10 | M&L Rendering 15 mm thick cement plaster in CM 1:6 onfair faces of brick/concrete work surfaces finished fair and even complete all as specified and directed. |
| 11 | M & L for rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surfaces of wall, surface finished fair and even complete all as specified and directed. |
| 12 | Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 122 x 54 mm & sash 47 x 64 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multichambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. (Glass or wiremesh shall be paid separately). Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 13 | M&L sheet glass 4.8 mm thick ordinary quality and glazing with oil putty and pin in square exc 0.50 sqm in each pan complete as directed. |
| 14 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm andfixed with tinned stacks or galvanised wire staples, complete all as specified and as directed. |
| 15 | Supply and fixing factory made uPVC white colour Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm) comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality complete all as specified and directed by Engineer-inCharge. (Glass shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made |
| 16 | Supply and fix Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long, size of grid 605 x 605mm complete all as specified and directed. |
| 17 | S & F anodised aluminium snap grid frame work for false ceiling ( size of grid 605x605 mm ) all as specified. |
| 18 | S & F Non asbestos fibre cement designer building boards 6 mm thick fixed or laid/ inserted to timber/GI/Aluminium framework with screws in ceiling complete all as specified. |
| 19 | M&L for framed work such as grills etc with ends of bars shouldered nd or riveed or forged into spike, framed guard bars and similar work conforming to Fe 290 Gde-E-165 complete all as specified and directed. |
| 20 | M&L for 18 to 20mm thick green marble (table rubbed and polished) in steps, jambs, pillars, window cills,bathroom corners cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with green marble shade complete all as spd and directed. |
| 21 | Material & Labour for preparation of new surfaces of plastered walls and applying Twocoats ofDistempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification. over and includinga coat of primer and 1.0 mm thick white wall care putty (premiumquality) over plastered surfaces of walls to prepare the surface even and smooth complete all as specified. |
| 22 | Material & labour preparation of newly plastered surfaces of wall & applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces |
| 23 | M&L for preparing of new steel & ironsurfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enameled paint over a coat of Red oxide zinc chrome primer zinc chrome complete all as specified and as directed. |
| 24 | Taking down carefully point wiring for one light, socket or power etc incl all fittings such as switches sockets, holders, light fittings, fan requlators etc and making good the disturbed surface of wall, ceiling etc includingseperating serviceabel light fittings, switches etc and keeping in safe custody for reuse and removal of unserviceable materials from site complete all as specified and directed. |
| 25 | M & L for concealed point wiringcomplete with 1.5 sq mm FRLSH ,PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red Colour use for Phase & Black Colour use for Neutral),drawn into and including non metalic PVC rigid conduit medium grade of suitable size and conduit accessories fixed on wall, floor, roof etc. and WITHincludingofFRLSH PVC insulated 1.5 sq mm copper conductor for earth continuity (Green Colour)and connected to common earth dolly and including pressed steel terminal flush boxesmade out of 1.6 mm thick MS sheet suitable for modular switches concealed in wall , with and includingmodular cover plate with frame for housing the switches socket,outlet etc.,all as specified and directed by Engineer-in-Charge for one light point controled by one one way 5/6 Amp switch Note:-(a) Note :- Cost of PVC conduit, cutting chases of wall, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate. |
| 26 | All as per item No. 25.00 here-in- before but5 Amp socket on same boardwith other switches complete all as specified and as directed. |
| 27 | Allas per ItemNo 25.00 here-in- before but for onecalling bellpoint controlled by one one way Bell switches complete all as specified and as directed. |
| 28 | All as per BOQ item No 25.00 here-in-beforebut for one power pointtusing by2.50 sq mm FRLSH,PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red Colour use for Phase & Black Colour use for Neutral), and with and including FRLSH,PVC insulated multi stranded copper conductor single core 2.50 sq mmconductor for earth continuity (Green Colour) , on independent board( but Not below the switch board of light points in the same vertical plane). |
| 29 | All as per BOQ item No 25.00 here-in-beforebut for one power pointtusing by4.00 sq mm FRLSH,PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red Colour use for Phase & Black Colour use for Neutral), and with and including FRLSH,PVC insulated multi stranded copper conductor single core 4.00 sq mmconductor for earth continuity (Green Colour) , on independent board( but Not below the switch board of light points in the same vertical plane). |
| 30 | Supply & Fixing switch modular type 6 Amp one way, one module, single phase, complete all as specified and directed. (Note : Item to be measured if executed under new point wiring) |
| 31 | S&F socket outlet 5 Amps, 5 pin, modular type, 2 module , single phase with shutter complete all as specified and as directed. (Note : Item to be measured if executed under new point wiring) |
| 32 | Supply & Fixing switch modular type 15/16 Amp one way, two module, single phase, complete all as specified and directed.(Note : Item to be measured if executed under new point wiring) |
| 33 | S&Fsocket outlet15/16 Amps,6 pin, modular type, 2 module , single phase shutter typed complete all as specified and as directed. (Note : Item to be measured if executed under new point wiring) |
| 34 | Supply & Fixing bell push ,modular type 6 Amp SP one way, 1 module , complete all as specified and as directed.(Note : Item to be measured if executed under new point wiring) |
| 35 | Supply & Fixing fan regulator modular step type 120 W 2 module suitable for 230 volt .cmplete all as specified and as directed. (Note : Item to be measured if executed under new point wiring) |
| 36 | Material & Labour forpoint wiringcomplete with 1.5 sq mm FRLSH, PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red Colour use for Phase & Black Colour use for Neutral),drawn into and including PVC casing- caping (double interlock type) ofnot less than 20mm width with accessories and fittingssuch as bends, elbows, tees, crosses, junction box etc, fixed on wall/ceiling with GI saddles, GI screws, rawl plugs etc. for one light/fan/ bell point controlled by one switch including pressed steel terminal box powder coatedof suitable size with 3 mm thick plastic laminated sheet cover of approved make for housing/mounting switches, sockets & regulators etc. and drawing1.5 sq. mm copper solid conductor PVC insulated, unsheated cable as earth continuity conductor, connected to common earth and earth dolly , all as specified and directed by Engineer-in-ChargeNote :- Cost of PVC casing & capping, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate.(ii) Length of point wiring up to 7.50 meter and to be measured from switches to ceiling rose or to the actual load. |
| 37 | All as per item No. 36.00 here-in- before but5 Amp socket on same boardwith other switches complete all as specified and as directed. |
| 38 | Allas per ItemNo 36.00 here-in- before but for onecalling bellpoint controlled by one one way Bell switches complete all as specified and as directed. |
| 39 | All as per BOQ item No 36.00 here-in-beforebut for one power pointtusing by2.50 sq mm FRLSH,PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red Colour use for Phase & Black Colour use for Neutral), and with and including FRLSH,PVC insulated multi stranded copper conductor single core 2.50 sq mmconductor for earth continuity (Green Colour) , on independent board( but Not below the switch board of light points in the same vertical plane). |
| 40 | All as per BOQ item No 36.00 here-in-beforebut for one power pointtusing by4.00 sq mm FRLSH,PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red Colour use for Phase & Black Colour use for Neutral), and with and including FRLSH,PVC insulated multi stranded copper conductor single core 4.00 sq mmconductor for earth continuity (Green Colour) , on independent board( but Not below the switch board of light points in the same vertical plane). |
| 41 | Supply and fixed switch piano flush type, single pole , 5/6 Amps, one way complete all as specified. (Note : Item to be measured if executed under new point wiring) |
| 42 | Supply & Fixingsocketoutlets 2 in 1, 5/6 Amps, 230/240 V complete all as specified and as directed .(Note : Item to be measured if executed under new point wiring) |
| 43 | Supply and fix switch socket combination 2 in 1 multipurpose5 pin ,(6 Amps ) flush typecontrolled by one switch complete all as specified. (Note : Item to be measured if executed under new point wiring) |
| 44 | Supply and fixed switch socket combination5 in 1 , 6 pin ,(5/16 Amps ) flush typecontrolled by one switch complete all as specified. (Note : Item to be measured if executed under new point wiring) |
| 45 | Supply & fixed ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified. (Note : Item to be measured if executed under new point wiring) |
| 46 | Supply & fixed stepped type electronic fan regulator flush type 240 Volts ISI marked complete all as specified . (Note : Item to be measured if executed under new point wiring) |
| 47 | Supply & fixed Bell push , flush type , 5 amp complete all as specified. (Note : Item to be measured if executed under new point wiring) |
| 48 | Supply & fixed Buzzer, Ding dong, AC 230 Volts, single pole 230 volts all as specified and directed. (Note : Item to be measured if executed under new point wiring) |
| 49 | Supply & fixed lamp holder, PVC/polycarbonate type with back plate straight or anfular suitable for batten fittings complete all as specified. (Note : Item to be measured if executed under new point wiring) |
| 50 | Supply and fixing for concealedtype sub main wiring with two run of 4.00 Sqmm single core PVC FRLSH PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and includingthrough Rigid non-metallic PVC conduit(medium) ISI marked of size 25mm bore with all fittings like tee/Bend/Elbow/Reducer/Bell mouth/Junction / Terminal Boxesetc. and fixing accessories such as coupler, lock nuts, saddles, pipe hook etc.including one run of 4.00 Sqmm single core PVC FRLSH PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified.Note : (i) Note : 2 runs of line conductor,one run of earth continuity conductor, one run of PVCconduit shall be measured as unit length. (ii)Cost of PVC conduit, conductors,making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate. |
| 51 | All as per BOQ item No 50.00 here-in-beforebut with two run of 6.00 Sqmm single core PVC FRLSH, PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) and one run of 6.00 Sqmm single core PVC FRLSH, PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified and as directed. |
| 52 | Supply and fixing for surfacetype sub main wiring/circuit wiring with two run of 4.00 Sqmm single core PVC FRLSH, PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and including drawn into and including PVC casing- caping (double interlock type) ofnot less than 25mm width with accessories and fittingssuch as bends, elbows, tees, crosses, junction box etc, fixed on wall/ceiling with GI saddles, GI screws, rawl plugs etc. including one run of 4.00 Sqmm single core PVC FRLSH, PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified.Note : (i) Note : 2 runs of line conductor,one run of earth continuity conductor, one run of PVCcasing caping shall be measured as unit length. (ii)Cost of PVC casing caping, conductors,making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate. |
| 53 | All as per BOQ item No 52.00 here-in-beforebut with two run of 6.00 Sqmm single core PVC FRLSH, PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) and one run of 6.00 Sqmm single core PVC FRLSH, PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified and as directed. |
| 54 | S & Fin repair LED street/security lights nominal power 60 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumenefficacy of minimum 110 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hoursincluding fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed. |
| 55 | Taking down existing panel light fitting any type (600 mm x 600 mm) recess mounting/surface and S&F LED light fitting 36 watt recess mounting of size 600 mm x 600 mm , , LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz,lumen efficacy of minimum 115 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, ITHD below or less than 15%, WW available CCT of 3000K power factor of minimum 0.95, CRCA powder coated white after phosphochromate treatment housing, life span of minimum 50000 working hours including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmmx 3 core complete all as specified and directed by EIC. |
| 56 | S&F in repairs LED 20 Watt tube light fittingintregatedtype, includingLED retrofit tubelamp 20 W , LED tube light nominal power 20 Watt, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 110 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 life span of minimum 50000 working hours and LED batten with polycarbonate housing and polycarbonate diffuser complete fittingincluding connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fittingcomplete all as specified & directed..Note (i) Make of batten and LED tube lamp should be of same make. |
| 57 | S&F in repairs LED 20 Watt tube light fittingintregatedtype, includingLED retrofit tubelamp 20 W , LED tube light nominal power 20 Watt, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 110 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 life span of minimum 50000 working hours and LED batten with aluminium housing and polycarbonate diffuser complete fittingincluding connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fittingcomplete all as specified & directed..Note (i) Make of batten and LED tube lamp should be of same make. |
| 58 | Supply & fixing in repair LED light fitting 12 watt surface mounted round extruded aluminium housing down lighter with superior light output as per existing size and shape ,LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz,lumen efficacy of minimum 110 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, ITHD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, CRCA powder coated white after phosphochromate treatment housing, life span of minimum 50000 working hours including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmmx 3 core complete all as specified and directed by EIC. |
| 59 | S&F in repairs LED 9/10 Watt tube light fitting mirrorintregatedtype, includingLED retrofit tubelamp 9/10 W , LED tube light nominal power 9/10 Watt, L LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 115 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 extruded aluminium LED battenslife span of minimum 50000 working hours complete fittingincluding connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fittingincluding taking down old unserviceable complete all as specified & directed.. Note : Make of batten and LED tube lamp should be of same make. |
| 60 | Supply and fixing in repairSurface Spotlight LED 7W 3000K/4000K with aluminum structure, available with adjustable light engine swivel type 240V AC Lumen efficiency 70lm/W complete all as specified and directed. |
| 61 | Fixing only LED Flood light fitting 70Watt 230 V AC outdoor typecomplete all as specified and directed.Note : Flood light will be issued under Sch B free for fixing only. |
| 62 | S&F in repairs Post Top lantern LED type 36/40 watt 230volt outdoor typewith decorative post top for 360degree indirect light IP 65 Protection with impact and corrosion resistant suitable for service bracket dia 40mm GI pipe complete with all accessories including connected with twin core twisted flexible copper conductor of suitable sizecomplete all as specified and directed. |
| 63 | S & F in repairs LED bollards light 9W/10w for pathways and garden with aluminium extrusion UV stabilised injection moulded opal polycarbonate diffuser for spotless lightening with IP65 including foundation protection complete all as specified and directed. |
| 64 | Assembling and Hanging only ceiling fan (M.D.supply) and connecting up including provision of cable from ceiling rose or connector to fan including Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store complete all as specified and as directed. Note : Ceiling fan including blade, rod and canopy will be issued under Sch B free for hanging/fixing only |
| 65 | Fixing only in repairs exhaust fan (M.D. supply) with necessary bolts (6 inches long, 6 mm dia.) with nuts and washers for fixing the fan in wall including making necessary electric connectionfromceiling rose to the fan with PVC insulated flexible cord copper of size 0.75 sqmm and removing fan and blades to store complete all as specified and as directed. Note : Exhaust fan including louvers will be issued under Sch B free for hanging/fixing only |
| 66 | Fixing only in repairs exhaust fan (M.D. supply) made of sturdy Engineering plasticwith necessary bolts including making necessary electric connectionfromceiling rose to the fan with PVC insulated flexible cord copper of size 0.75 sqmm and removing fan and blades to store complete all as specified and as directed. Note : Exhaust fan including louvers will be issued under Sch B free for hanging/fixing only |
| 67 | S&F in repairs VTPN distribution board with provision for 4 pole MCCB up to 160A as incomer with three phase and single phase (TP/SP) MCB outgoing with and including insulated busbar (tinned electrolytic copper) arrangement, shrouded neutral bar and earth bars, Top and bottom removable gland plates with knockouts 4 way Double door enclosure made up of CRCA sheet steel,powder coated, IP 43, IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match asthe existing withall as specified and directed by Engr-in-charge |
| 68 | S & F in repairs sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 12 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 , IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match asthe existing withall as specified and directed by Engr-in-charge. |
| 69 | S & F in repairs sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 8 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 , IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match asthe existing withall as specified and directed by Engr-in-charge. |
| 70 | S & F in repairs sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 4 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 , IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match asthe existing withall as specified and directed by Engr-in-charge. |
| 71 | Supply and fixing in repairs MCCB 4 Pole 100 Amps Breaking Capacity 16KA ,415V to be housed in DBs complete including necessry connectionall as specified and directed engr-in-charge complete all as specified and directed. |
| 72 | Supply and fixed inMCB TPN 40 to 63 Amps,\"C\" Curve 10kA, 415 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed engr-in-charge. |
| 73 | Supply and fixed MCB SPN 32 Amps,\"C\" curve 10kA, 240 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed engr-in-charge. |
| 74 | Supply and fixed MCB SP 6-32 Amps,\"C\" curve 10kA, 240 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed engr-in-charge. |
| 75 | Supply and fixing in repair of 20Astarter switch for AC including necessary connection all as specified and directed engr-in-charge. |
| 76 | Supply & Fixing in replacement of \"Modular AC Box With 20A SP MCB, Plastic Enclosure & Unbreakable Heavy Duty With ISI Plug Top\", complete all as specified and directed. |
| 77 | Material andlabour for earthing complete with Galvanised steel earth plate electrode 600x600x6 mmmm buried directly in ground (Earthpit not less than2.25m below ground level) with top edge of theplate not less than 1.5m below normal groundlevel, connected to GI wire 4 mmasearth lead by means of bolt, nuts, check nutsandwashers of galvanised iron or steel, upto 7.5mlength, earth strip protected by andincluding 15 mm diaGI pipe (medium grade) andconnected to main test point or body of pole/pannel or lightening arrester of main controlling switch as directed including concrete pit in PCC(1:3:6)type C1 , Precast RCC(1:2:4)TypeB1 coverslab of size 54x54x5 cm reinforced with 8 mm dia TMT bars @ 100mm C/C bothwayswith onehandle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20 mm boreGI Pipe (Medium Grade) for watering, Charcoal andsalt in alternate layers of 15 cm (Compacted Thickness) around the earth electrode including necessary excavation, earth work in any typeof soil anddisposal of spoil to a distance n.exc50 m andnecessary testing complete all asshown in Electrical Plate No 3 of SSRPart-I.NOTE : 1. The unit rare includes for protectionh GI pipe of 15mm and watering pipe of 20mm bore including excavation for earth pit in any type of soil/disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to acheive desired result as the soil resisitivity is very high. 3. The cost of GI wireincluding protection pipe,from top of earth plate upto 7.5 meter above/below ground level is deemed to be included in the unit rate. 4. All the joints in GI wire and connectgion with earth plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5.Costing of welding and nut bolts are deemed to be included in the unit rate |
| 78 | Supply and fixed in repair D clamp of strip size 25x6 mm with suitable washer,nuts, bolts in any shape or size as indicated or directed including making hook for hanging ceiling fan and inclusive of one primer coat ,one under coat, one finish coat of paint complete for hanging of ceiling fan all as specified and as directed. |
| 79 | S & Fin repair LED street/security lights nominal power 35/36 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumenefficacy of minimum 110 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hoursincluding fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed. |
| 80 | S&F recess mounting luminaire (PANEL LIGHTING) with high performance LEDs, suitable for mounting withArmstrong/Grid ceiling Fixture size: (LxW) in (600 x 600) mm LED 36 Watt with CRCA powder coated housing (white after phosphochromate treatment) High efficiency long life LED package in integral module with lumen efficacy of >120 lm/W and viewing angle of 120° to ensure better uniformity, electronic LED driver (SMPS based constant current supply) with Output Short-circuit protection, Surge protection & other reliability test as per IS:15885 Part 2/Sec 13. operational voltage of 170 volts to 270 volts, frequency of 50 Hz,protection grade IP 20, CRI greater than or equal to 80%,THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 , life span of minimum 50000 working hours complete fittingincluding connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core,including taking down old unserviceable complete all as specified & directed: |
| 81 | Supply & Fixing in replacement switch modular type 6 Amp one way, one module, single phase, complete all as specified and directed. |
| 82 | S&Fin replacement socket outlet 5 Amps, 5 pin, modular type, 2 module , single phase complete all as specified and as directed engr-in-charge. |
| 83 | Supply & Fixing in replacement switch modular type 15/16 Amp one way, two module, single phase, complete all as specified and directed. |
| 84 | S&Fin replacement socket outlet 15/16 Amps, 5 pin, modular type, 2 module , single phase complete all as specified and as directed engr-in-charge. |
| 85 | Supply & Fixingin replacement fan regulator modular step type 120 W 2 module suitable for 230 volt .cmplete all as specified and as directed engr-in-charge. |
| 86 | Supply and fixed in replacementswitch piano flush type, single pole , 5/6 Amps, one way complete all as specified engr-in-charge. |
| 87 | Supply & Fixing in replacementsocketoutlets 2 in 1, 5/6 Amps, 230/240 V complete all as specified and as directed engr-in-charge. |
| 88 | Supply and fix in replacementswitch socket combination 2 in 1 multipurpose(6 Amps ) flush typecontrolled by one switch complete all as specified engr-in-charge. |
| 89 | Supply and fixed in replacementswitch socket combination5 in 1 (5/16 Amps ) flush typecontrolled by one switch complete all as specified engr-in-charge. |
| 90 | Supply & fixed in replacementstepped type electronic fan regulator flush type 240 Volts ISI marked complete all as specified engr-in-charge. |
| 91 | Supply and fixing in replacement of Decorative wall light, gold finish fixture with white glass diffuser suitable for 1 N x9 W LED Lamp/2 N x7.5 W LED filament lamp E27 base complete all as specifed and directed engr-in-charge. |
| 92 | Supply and fixing in replacement of Decorative wall light, stainless steel, rust free fixture with white glass diffuser suitable for Decorative wall light fixture 1 N x 9 W LED Lamp/1 N x 7.5 W LED filament lamp E27 base |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail