| 1 | Schedule-1:Civil Works |
| 2 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 100m outside the periphery of the area cleared. |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 100m and lift upto 3m, as directed by Engineer-incharge.i) All Kinds of soil.Note: Cutting of road at few locations shall be included in the quoted rate. |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 30cm in depth, consolidating each deposited layer by ramming and watering, lead up to 100 m and lift upto 3m as per the directions of Engineer-incharge.Note: Thickness of each layer shall be as per directions of Engineer-in-charge. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to & above plinth level: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 6 | Providing & laying in position ready mixed or site batched design mix cement concrete of M35 grade for reinforced cement concrete works; using coarse aggregates & fine aggregates, Ordinary Portland cement, admixtures in recommended proportions as per IS: 9103 to accelerate/retard setting of concrete, to improve durability & workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per the directions of Engineer-in-charge. |
| 7 | Providing & laying in position ready mixed or site batched design mix cement concrete of M35 grade for reinforced cement concrete works; using coarse aggregates & fine aggregates, Ordinary Portland cement, admixtures in recommended proportions as per IS: 9103 to accelerate/retard setting of concrete, to improve durability & workability without impairing strength; including pumping/manual placement etc. for second stage concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per the directions of Engineer-incharge.Note: Concrete shall be used as second stage/secondary concrete, which may require manual placement. |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. as per the directions of Engineer-incharge. |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. as per the directions of Engineer-incharge. |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 11 | Providing and laying Non Pressure NP-3 class RCC Pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. complete in all aspects as per the directions of Engineer-incharge.1. 500/600mm dia RCC Pipes. |
| 12 | Supplying and providing reinforcement (for reinforced cement concrete works) Thermo-mechanically treated (TMT) bars of Fe 500/500D grade conforming to IS:1786 including initial straightening of coiled/uncoiled bars, removal of loose rust, cutting, bending to correct size & shape, bindingat each intersection and placing at any position, at any height and depth complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Engineer incharge.-Reinforcement of all dia. |
| 13 | BRICK MASONRY (CLAY BURNT BRICKS) :- Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 for all elevations in Cement mortar 1:6 (1 cement : 6 coarse sand) at all heights and depths laid to proper position line, level as per the drawings and specifications including providing necessary scaffolding,staging, raking out of joints, curing etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of Site Engineer. |
| 14 | 12MM CEMENT PLASTER (1:6) :- 12 mm cement plaster of mix: 1:6 (1 cement: 6 fine sand) |
| 15 | Supply & placing in position Pre-cast RCC cover of required shape, sizes, of M-25 grade cement concretefor RCC works, including cost of centering, shuttering, reinforcement of 10mm diameter TMT bars Fe-500/500D grade @ 150mm c/c on both ways, encasing on all edges with 1.6mm thick MS Sheet, duly painted, providing hooks for lifting etc. to cover the ARV Pits all complete & as per the direction of engineer. Reinforcement shall be welded with MS Sheet. Cost of carriage, if any shall be deemed to be included in quoted price. |
| 16 | Schedule-2: Mechanical Works |
| 17 | Supply, Storage at site of Carbon steel pipes SA-53, Grade-B, Sch-40, ASME/ANSI B 36.10, SMLS, BW/Plain Ends as per 700 Mwe/71710/01/PMS as per the relevant Technical Specifications, IS codes. |
| 18 | DN 15, SMLS, Plain Ends, 2.77 mm Thick |
| 19 | DN 25, SMLS, Plain Ends, 3.38 mm Thick |
| 20 | DN 100, ERW, BW Ends, 6.02 mm Thick |
| 21 | DN 200, ERW, BW Ends, 8.18 mm Thick |
| 22 | DN 300, ERW, BW Ends, 9.53 mm Thick |
| 23 | Supply, Storage at site Carbon steel Pipe FittingsSA-234, Grade-WPB, ASME/ANSI B 16.9 as per 700 Mwe/71710/01/PMS as per the relevant Technical Specifications, IS codes. |
| 24 | Elbow, DN 200, SMLS,BW Ends, Long Radius 90 deg, 8.18 mm Thick |
| 25 | Elbow, DN 300, ERW, BW Ends, Long Radius 90 deg, 9.53 mm Thick |
| 26 | Concentric Reducer, DN 300 X DN 200, Thickness same as pipe, BW Ends |
| 27 | CAP, DN 300, Thickness same as pipe, BW Ends |
| 28 | Equal TEE, DN 300 x DN 300, SCH STD , BW Ends |
| 29 | Supply, Storage at site Carbon Steel Flanges SA-105, ASME/ ANSI B 16.5 / AWWA C207, CLASS B as per 700 Mwe/71710/01/PMS including nuts and bolts, gaskets etc. as per the relevant Technical Specifications, IS codes. |
| 30 | DN 100, 150#, SORF, Serrated Finish |
| 31 | DN 200, 150#, SORF, Serrated Finish |
| 32 | DN 300, Class B, SOFF, AWWA C207, CLASS B, Serrated Finish |
| 33 | Supply, Storage at site Carbon Steel Coupling SA-105, ASME/ ANSI B 16.11 as per 700 Mwe/71710/01/PMS as per the relevant Technical Specifications, IS codes. |
| 34 | Cap, DN 15, 3000#, Threaded |
| 35 | Cap, DN 25, 3000#, Threaded |
| 36 | Full coupling, DN 15, 3000#, SW |
| 37 | Screwed coupling, DN 25, 3000#, Screwed |
| 38 | Supply, Storage at site Carbon steel Sockolet SA-105, MSS-SP-97 as per 700 Mwe/71710/01/PMS as per the relevant Technical Specifications, IS codes. |
| 39 | DN 200 x 15, 3000#, SW |
| 40 | DN 300 x 15, 3000#, SW |
| 41 | DN 200 x 25, 3000#, SW |
| 42 | Welding of CS pipe with SMAW process (SW/FW) |
| 43 | Welding of CS pipe with SMAW process (BW/NW) |
| 44 | Dye Penetrant examination of weld joints |
| 45 | Fabrication, Erection and Hydrotesting of pipes and fittings |
| 46 | Supply of material, Storage at site, Fabrication of CS supports with level 5 NDE requirement as per specifications |
| 47 | Erection of CS supports with all NDE requirements Level-5 as per specifications. |
| 48 | Painting of Carbon steel piping and supports which shall comprise of suitable surface preparation followed by application of 2 coats (50 micron per coat) of polyamide cured high build epoxy zinc phosphate primer, 1 coat (75 micron) of polyamide cured high build epoxy intermediate with laminar micaceous ion oxide pigment, 52% solid contents and 2 coats at site (40 micron per coat) of aliphatic isocynate cured acrylic polyeurathane. A total coating thickness of 250 micron (min.) shall be achieved. |
| 49 | Supply, Storage at site, Fabrication, Erection and Hydro Testing of HDPE pipe of of Grade PE 100, SDR 17 and PN 8 rating. This item shall also include Bending of the pipe (if required), Joining of the pipe through butt fusion welding / Flanged Joints, providing necessary hardware like Nuts, Bolts, gaskets, Washers, locknuts etc as per technical specification, hydrotesting to required pressure complete as per the relevant Technical Specifications, IS codes and directions of Engineer-In-Charge. |
| 50 | DN 355, 23.1 mm Thick, PE |
| 51 | DN 110, 7.3 mm Thick, PE |
| 52 | Supply, Storage at site, Fabrication, Erection and Hydro Testing of HDPE pipe fittings of of Grade PE 100, SDR 17 and PN 8 rating. The item shall also include Joining of the pipe/fitting through butt fusion welding / Flanged Joints, providing necessary hardware like Nuts, Bolts, gaskets, Washers, locknuts etc, hydrotesting to required pressure complete as per the relevant Technical Specifications, IS codes and directions of Engineer-In-Charge. |
| 53 | Elbow, DN 355, 23.1 mm thick, 1.5D, 45 Deg., Butt Fusion type |
| 54 | Elbow, DN 110, 7.3 mm thick, 1.5D, 90 Deg., Butt Fusion type |
| 55 | Elbow, DN 355, 23.1 mm thick, 1.5D, 90 Deg., Butt Fusion type |
| 56 | Reducing TEE, DN 355 x DN 110, BW, Butt Fusion type |
| 57 | Stub Flange, DN 355, Long Spigot, Butt Fusion type |
| 58 | Stub Flange, DN 110, Long Spigot, Butt Fusion type |
| 59 | Supply, Storage at site, Fabrication, Erection of Flange, Class B, FABRICATED FROM SA 515 Gr.60 SINGLE PLATE, TAILORMADE FOR HDPE, SOFF, Seratted finish matching with companion CS Flanges. The item shall also include Joining of the pipe/fitting through butt fusion welding / Flanged Joints, providing necessary hardware like Nuts, Bolts, gaskets, Washers, locknuts etc as per technical specification as per the relevant Technical Specifications, IS codes and directions of Engineer-In-Charge. |
| 60 | DN 300 (355) |
| 61 | DN 100 (110) |
| 62 | Supply, Storage at site, Erection of Valves through threaded/flanged/welded joints as specified inclusive of providing of hardware like Nuts, Bolts, gaskets, Washers, locknuts etc as per technical specification as per the relevant Technical Specifications, IS codes and directions of Engineer-In-Charge. |
| 63 | Gate Valve, 15 NB, 900#, SW Ends SA 105, TRIM SS-304 as per 700 MWe/71003/2001/VSS and PC-E-542 |
| 64 | Gate Valve, 25 NB, 900#, SW Ends SA 105, TRIM SS-304 as per 700 MWe/71003/2002/VSS and PC-E-542 |
| 65 | Kinetic air release valve, 100 NB, 125#, FL Ends SA 216, TRIM SS-304 as per GHAVP-1&2/71123/5035/ VSS and PC-E-542 |
| 66 | Gate Valve, 100 NB, 150#,FL Ends SA 216, TRIM SS-304 as per 700 MWe/71003/2007/VSS and PC-E-542 |
| 67 | Gate Valve, 200 NB, 150#, FL Ends SA 216, TRIM SS-304 as per 700 MWe/71003/2011/VSS and PC-E-542 |
| 68 | Check Valve, 200 NB, 150#,FL Ends SA 216, TRIM SS-304 as per GHAVP-1&2-71123-5005-VSS and PC-E-542 |
| 69 | CAST CARBON STEEL MANUALLY OPERATED BUTTERFLY VALVE WITH FLANGED ENDS, 300 NB, 150 LBS, Flanged ends as per AWWA C-207 CLASS D, SA216 Gr. WCB as per 700 MWe/71003/2046/VSS |
| 70 | Design, engineering, preparation of engineering & manufacturing drawings, Approval, Fabrication, manufacture, procurement, inspection, shop testing, safe delivery at site (freight & insurance) and guarantee, supply of spares, Erection at site of submersible type pump with electric motor including hardware like companion flanges Nuts, Bolts, gaskets, Washers, locknuts etc as per the relevant Technical Specifications, IS codes and directions of Engineer-In-Charge. |
| 71 | Design, engineering, preparation of engineering & manufacturing drawings, Approval, Fabrication, manufacture, procurement, inspection, shop testing, safe delivery at site (freight & insurance) and guarantee, supply of spares, Erection at site of Coarse Screen as per technical specification complete as per the relevant Technical Specifications, IS codes and directions of Engineer-In-Charge. |
| 72 | Design, engineering, preparation of engineering & manufacturing drawings, Approval, Fabrication, manufacture, procurement, inspection, shop testing, safe delivery at site (freight & insurance) and guarantee, supply of spares, Erection at site of 200 NB Inline Rubber expansion Bellows including hardware like companion flanges Nuts, Bolts, gaskets, Washers, locknuts etc as per the relevant Technical Specifications, IS codes and directions of Engineer-In-Charge. |
| 73 | Design, engineering, preparation of engineering & manufacturing drawings, Approval, Fabrication, manufacture, procurement, inspection, shop testing, safe delivery at site (freight & insurance) and guarantee, supply of spares, Erection at site of 1 Ton Monorail Hoist with Trolley as per technical specification, Load testing as per the relevant Technical Specifications, IS codes and directions of Engineer-In-Charge. |
| 74 | Design, engineering, preparation of engineering & manufacturing drawings, Approval, Fabrication, manufacture, procurement, inspection, shop testing, safe delivery at site (freight & insurance) and guarantee, supply of spares, Erection at site of 3 Ton Monorail Hoist with Trolley as per technical specification, Load testing as per the relevant Technical Specifications, IS codes and directions of Engineer-In-Charge. |
| 75 | Design, Supply, Installation, Testing and Commissioning of Ventilation system of Matkana pump House as per the relevant Drawings, Technical Specifications, IS codes and directions of Engineer-In-Charge. |
| 76 | Schedule-3: Electrical Works |
| 77 | Design, engineering, procurement, manufacture, quality assurance, routine and acceptance tests, packing & forwarding, transportation, safe delivery at site of following type tested equipment conforming to requirement of tender specifications, drawings & applicable standards, including storage at site, handling, erection / installation / laying & termination, testing at site and commissioning of equipment complete in all respects for sucessful charging of the system. (cost includes the supply of fire extinguishers, required as per relavant standards) |
| 78 | 415V AC MCC (M420 - Matkana) as per the technical specification PC-E-00172 (MCC) & 415V Single Line Diagram (GHAVP-1TO4/52540/2001/ED/R1) withmotor control scheme, numerical relay protection, indications, control for motor start/stop etc. complete in all respect and with all the accessories.Note:- 1. Suitable starter arrangement for motors to be provided as per motor OEM recommendation. 2. Suitable arrangement for incomming cable connection (from transformer) of 630A to be provided.3. Transformer and HT cables shown in drg are not in the scope of this contract, but panel shall have arrangement for 51N protection.4. For incommer supply, purchaser\"s cable it to be connected to this panel covered under this scope of work andpanel shall also have arrangement for connection of busduct in future. Costing for such arrangement is included in this item. |
| 79 | 415V, AC indoor type, metal clad, floor mounted lighting cum space heater board panel with 415V, 63A, 3 phase, 4 wire bus, 10kA symmetrical fault current.4 pole 63 A MCB as incomer, 6 Nos. of 10A, 9 Nos. of 16A & 3 Nos. of 32A,240V2 pole MCBs (9kA) as outgoing feeders inclusive of all control devices (incl. astro timmer for outdoor lights) as per drawing no. 415V Single Line Diagram (GHAVP-1TO4/52540/2001 /ED/R1) & technical specification (PC_E_00206 (ACDB) and technical specifications for matkana pond, complete in all respects. |
| 80 | 415V, AC indoor type, metal clad, wall mounted, Ventilation Distribution Board with bus of 415V, 32A, 3 phase, 4 wire, 10 kA symmetrical fault current, 32A 4pole MCB for incomer and 7 Nos.outgoing feeders having approximately 1 A,415 V, 3 pole, MPCB and 10A contactor (9 kA) along withfan control schemein line with drawing No. GHAVP-1TO4/73300/2003/P&ID, GHAVP-1&2/60000/2401/ES and GHAVP-1TO4/52540/ 2001/ED/R1. (MPCB rating shall be selected for 0.37kw fans during detail engineering by Vendor). |
| 81 | Power Pack module for feeding 24V DC power supply, having 2hrs battery back-up, charging arrangement from input voltage as 230V AC, 50Hz, Number of output through inbuild MCB shall be as per requirement with 10% as spare MCBs. |
| 82 | Design, engineering, procurement, manufacture, quality assurance, routine and acceptance tests, packing & forwarding, transportation, safe delivery at site of following type tested Low voltage power cables & control cables conforming to requirement of tender specifications (415 V Power Cables PC-E-00184, Electrical Control Cables PC-E-00183), cable installation note GHAVP-1&2/DD/53300/2102, drawings & applicable standards, including storage at site, handling, laying, burying, termination, testing at site and commissioning of Low voltage power cables and control cables complete in all respects for sucessful charging of the system |
| 83 | LV power cable, 1100V grade, 3C X 120 sq.mm as minimum cross section, Al., XLPE insulated, Armoured, FRLS PVC sheath |
| 84 | Double compression cable glands for 3C X 120 sq.mm LV power cable |
| 85 | LV power cable, 1100V grade, 4C X 16 sq.mm as minimum cross section, Cu., XLPE insulated, Armoured, FRLS PVC sheath |
| 86 | Double compression cable glands for 4C X 16 sq.mm LV power cable |
| 87 | LV power cable, 1100V grade, 3C X 2.5 sq.mm as minimum cross section, Cu., XLPE insulated, Armoured, FRLS PVC sheath |
| 88 | Double compression cable glands for 3C X 2.5 sq.mm LV power cable |
| 89 | Control cable, 1100V grade, 2C X 2.5 sq.mm as minimum cross section, Cu., PVC insulated, Armoured, FRLS PVC sheath |
| 90 | Double compression cable glands for 2C X 2.5 sq.mm, Cu., PVC insulated, Armoured, FRLS PVC sheath |
| 91 | Control cable, 1100V grade, 10C X 2.5 sq.mmas minimum cross section, Cu., PVC insulated, Armoured, FRLS PVC sheath |
| 92 | Double compression cable glands for 10C X 2.5 sq.mm, Cu., PVC insulated, Armoured, FRLS PVC sheath |
| 93 | Lugs suitbale for 16 sq.mm, Cu., cable |
| 94 | Lugs suitable for 120 sq.mm, Al., cable |
| 95 | Lugs suitable for 2.5 sq.mm, Cu., cable |
| 96 | Design, engineering, procurement, manufacture, quality assurance, routine and acceptance tests, packing & forwarding, transportation, safe delivery at site of followingcable trays including support structures and accessories, conforming to requirement of tender specifications (PC-E-00165, Cable Trays & Accessories), cable installation note GHAVP-1&2/DD/ 53300/2102, cable tray accessory drawings GHAVP-1&2/53330/2101, 2102, 2103, 2104, 2105/DD& Cable tray layout GHAVP-1&2/53330/2007/GA, etc. & applicable standards, including storage at site, handling, installation of cable trays, fabrication and erection of support structures and accessories complete in all respects. |
| 97 | 300X100 Solid type cable tray with cover |
| 98 | 150X100 Solid type cable tray with cover |
| 99 | 300X100 Ladder type cable tray without cover |
| 100 | 150X100 Ladder type cable tray without cover |
| 101 | 300xR1050X100 ELBOW,90 Deg Vertical Inside,Solid Type With Cover |
| 102 | 150xR300X100 ELBOW,90 Deg Vertical Inside,Solid Type With Cover |
| 103 | 300x300xR600X100 TEE,Equal,Ladder Type Without Cover |
| 104 | 150xR300X100 BEND,90 Deg Horizontal,Ladder Type Without Cover |
| 105 | Coupler plates with hardware |
| 106 | 100NB medium duty GI pipes with accessories, clamps and hardware for fixing the pipes to the supports for routingcables from cable trays or Distribution Boardsor Junction Boxes to various field equipment or between equipmentor between cable trays. |
| 107 | 50NB medium duty GI pipes with accessories, clamps and hardware for fixing the pipes to the supports for routingcables from cable trays or Distribution Boardsor Junction Boxes to various field equipment or between equipmentor between cable trays. |
| 108 | Hot dip Galvanised support structural material consisting of flats, ISA 65,ISMC 75, any other size of ISA / ISMC, plates, etc. for rigid supports (ceiling, wall and floor supports) |
| 109 | Design, engineering, procurement, manufacture, quality assurance, routine and acceptance tests, packing & forwarding, transportation, safe delivery at site of following type testedlight fixtures, conforming to requirement of tender specifications (PC-E-00190 Light fixtures), lighting layout GHAVP-1&2/53100/2015/GA, etc. & applicable standards, including storage at site, handling, installation of light fixtures and accessories complete in all respects. |
| 110 | LED luminaire, minimum 3500 lux, with extruded aluminum housing, powder coated finish polycarbonate diffuser suitable for surface and suspension mounting (Type B) (3 loops of wiring) |
| 111 | Outdoor LED street lighting luminaire to mount on building periphery wall, minimum 4200 lux, with pressure die cast aluminum alloy housing with heat resistant toughened glass cover, powder coated finish (Type SL1), with astronomical timer switch (controlled by DB at S. No. A4.1.5) |
| 112 | Design, engineering, procurement, manufacture, quality assurance, packing & forwarding, transportation, safe delivery at site of following lighting system material, conforming to requirement of tender specifications, lighting installation note GHAVP-1&2/53100/2104/DD,lighting layout GHAVP-1&2/53100/2015/GA, etc. & applicable standards, including storage at site, handling, installation of lightsystem and accessories complete in all respects. |
| 113 | 240V AC, 5/15A single phase five pin, industrial type receptacle with MCB & ELCB |
| 114 | 240V AC, 30A, single phase five pin, industrial type receptacle with MCB & ELCB |
| 115 | 63A, 415V AC, 3-Phase, Industrial receptacle with MCB |
| 116 | Suitable Switch board with metal box & modular cover with modular type 5A switches |
| 117 | 1C x 2.5 Sq.mm as minimum cross section, 750V grade, stranded copper conductor, FRLS PVC insulated wires |
| 118 | 1C x 4 Sq.mm as minimum cross section, 750V grade, stranded copper conductor, FRLS PVC insulated wires |
| 119 | 1C x 1.5 Sq.mm as minimum cross section, 750V grade, stranded copper conductor, FRLS PVC insulated wires for earthing (Yellow Green) |
| 120 | 1C x 2.5 Sq.mm as minimum cross section, 750V grade, stranded copper conductor, FRLS PVC insulated wires for earthing (Yellow Green) |
| 121 | ERW heavy duty rigid 25mm dia GI conduits with all accessories like bends, elbows, couplers, hospital saddles, spacers, GI Junction boxes, GI pull boxes, etc., and other accessories required to complete the job on wall/ column/ ceiling etc. as per drawing. (The running length shall be measured along the centre line including bends, fittings etc along the run installed, but excluding the hidden length of conduits and lengths of pull boxes and junction boxes) |
| 122 | ERW heavy duty rigid 40mm dia GI conduits with all accessories like bends, elbows, couplers, hospital saddles, spacers, GI Junction boxes, GI pull boxes, etc., and other accessories required to complete the job on wall/ column/ ceiling etc. as per drawings. (The running length shall be measured along the centre line including bends, fittings etc along the run installed, but excluding the hidden length of conduits and lengths of pull boxes and junction boxes) |
| 123 | 25mm dia as minimum cross section flexible GI conduit for fixture hanging |
| 124 | Design, engineering, procurement, manufacture, quality assurance, packing & forwarding, transportation, safe delivery at site of following earthing material conforming to requirement of tender specifications, drawings & applicable standards, including storage at site, handling, excavation, laying / burying, welding, termination, testing at site and commissioning of earthing system complete in all respects. Installation shall be as per earthing installation note GHAVP1&2/53200/2104/DD. |
| 125 | Equipment earthing conductor of size 35X6mm, GS flat |
| 126 | Equipment earthing conductor of size 25X6mm, GS flat |
| 127 | Bare stranded Al conductor, 1Cx35sqmm |
| 128 | Supply & applicationoffire retardant compound over cable to form fire break capable of preventing propagation of fire for 30 minutes as per specifications PC-E-00173. Thickness of the filling material shall be as per the fire rating requirement. This item shall include the cost of fire stops, required if any. |
| 129 | Miscellaneous material needed to meet the electrical safety requirements as indicated by CEA or IE rules. |
| 130 | Supply of Insulating mat- Class-A as per IE rules/Indian standard IS:15652 in front and back side of all 415V and 240V panels/boards along the complete length. |
| 131 | Supply & Installation of Danger boards as per IS |
| 132 | Supply & Installation of Safety instruction chart in word duly framed with 5mm thick glass as required |
| 133 | Supply & Installation of Shock treatment chart |
| 134 | Supply, inspection, testing at the contractors works, handling and handover of all mandatory SPARES for all electrical euipments indicated in various technical specifications/ scope drawings.The spare quantity is subject to purchaser’s approval. |
| 135 | Mandatory SPARES for 415V MCC, as per technical specification PC-E-00172 (MCC_PMCC). Mandatory spares for 415V MCC includes but not limited to: 10% of all MCC components (like relays, contactor, fuse, etc.) used of each type and rating as per BOM subject to minimum 1 number shall be provided as minimum mandatory spare to purchaser. Complete ACB spare is not required. However, 10% subject to minimum 1 number of mandatory spares of ACB such as trip coil, close coil, spring charging motor, arc chute, arcing contact, limit switch, etc. shall be provided. Note:- the above requirement isin addition to the spare quantity covered by PC/E/00172. |
| 136 | Mandatory spares for all indoor/outdoor lights as per technical specification PC_E_00190 (Lighting Fixtures). Mandatory spares for indoor/outdoor lights includes but not limited to 5% of each type of fixture supplied, subject to a minimum number 1 (one). |
| 137 | Schedule-4: C&I Works |
| 138 | Supply, Erection and commissioning of Relay based Hardwired -Local Control Panels (Type-A) (375(W)x200(D)x465(H)) as per reference ED GHAVP-1&2/67330/2012/ED (Draft).1. 0-67330-PL-12A2. 0-67330-PL-12B With Each panel to be supplied with following componenets:a)Indicating Lamps-230V ac,10mm =11 no.b)Handswicthes-230VAC-3pos,9pole=3 no.c)Relays(4CO)-4NO+4NC=230VAC,5A=10 no.d)MCB=230VAC, 2pole, 2A= 4 no. e) MCB-24VDC-2A-2 nos.e) TB=80 no.f) SMPS-230V AC-24VDC,10A=1 no. Supplier shall submit the GA, BOM & internal wiring drawings of panel to NPCIL for approval before fabrication of panel. |
| 139 | Supply and laying of control cables as per specification |
| 140 | Control Cables-50 pair, C-07, 50PR#1.5Sq.mm, EPR, LHLS, OVERALL SHLD |
| 141 | Control Cables-25 pair,C-06, 25PR#1.5Sq.mm, EPR, LHLS, OVERALL SHLD |
| 142 | Control Cables-3 pair, C-03, 3PR#1.5Sq.mm, EPR, LHLS, OVERALL SHLD |
| 143 | Control Cables-2 pair, C-02, 2PR#1.5Sq.mm, EPR, LHLS, OVERALL SHLD |
| 144 | Control Cables-1 pair, C-01, 1PR#1.5Sq.mm, EPR, LHLS, OVERALL SHLD |