| 1 | Supply and erection of Galvanized Iron pole with galvanizing done in single dipping(Average coating thickness Minimum 65 Microns) continuously tapered poles havingOctagonal / Circular cross sections designed to withstand the maximum wind speed asper IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to gradeS355JO) and confirming to BSEN 10025 and shall be continuously tapered with singlelongitudinal welding. There shall not be any circumferential welding. The welding ofpole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall beprovided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 /IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be filletwelded to the pole shaft at two locations i.e. from inside and outside.The octagonalPoles shall have lockable door of approximate 500 mm length at the elevation of 500mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud typeconnector ( 4 nos) inside the pole at door opening for cable connection of followinglength and dimension as per table P-01 with base plate and foundation bolt on theExisting cement concrete foundation.All as per pre approved by Engineer in-charge. Foradditional technical parameters of products/ work , refer Annexure \"A\" attached withthis BSR . |
| 2 | Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as perpre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure \"A\" attached with this BSR . |
| 3 | Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, Highmast Poles as per Drawing attach at Table P-4 with Following Procedure & All as perpre approved by Engineer in-charge. For additional technical parameters of products/work , refer Annexure \"A\" attached with this BSR . |
| 4 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existingbracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablizationreport submitted for UV cover ) /Toughened Glass cover and secondary lens on eachLED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt andpotted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V ACwith High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor>0.95 driver Efficiency >85% ,THD(I) 70 and CCT 5700K +355K. Surge protectionshall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. drivershould be Phase to phase protection of 440 V for 4 Hrs. Manufactures WordMark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity.Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in houseNABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/report with liable warranty of product/accessories from OEM shall be submitted. All asper pre approved by Engineer in-charge. For additional technical parameters ofproducts/ work , refer Annexure \"A\" attached with this BSR . |
| 5 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured Coppercable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolytic grade Coppermade of copper rods confirming to IS 613-1964, of purity >99.7 %, Inner / outer sheathconfirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cabletrench / Cable tray (with cable tie) including testing etc. as required of following size.OEM must have it\"s own in house NABL accrediated Laboratory for testing procedureas per IS:10810 For additional technical parameters of product / work refer Annexure \"A\"attached with this BSR |
| 6 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat striparmouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume/ Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have it\"s own in house NABLaccrediated Laboratory for testing procedure as per IS:10810.For additional technicalparameters of product / work refer Annexure \"A\" attached with this BSR |
| 7 | Add Extra in item no. 60.1 to 60.4 for Laying Charges for cable through Vermeermachine by making pit at regular interval and repairing the pit after laying of cable withPCC/ Bitumin as required. |
| 8 | P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, StiffnessClass 750 N, Externally corrugated and having smooth surface inside with HDPECoupler, Elbow, Tee at required Depth below the ground for laying cable of followingNominal Outer dia. MFR Test report from NABL accrediated is to besubmitted.(Excavation of Earth & Back filling with compaction is to be Paid Extra)Allas per pre approved by Engineer in-charge. For additional technical parameters ofproducts/ work , refer Annexure \"A\" attached with this BSR . |
| 9 | Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. \"B\"class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wiremeshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber withlockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia.225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. andembodying the pipe complete with alternate layers salt and coke/ charcoal, testing ofearth resistance for value of 5 ohms or less as required & must record by engineer inchargeduring site visit and ensure to enter in measurment book. All as per pre approvedby Engineer in-charge. For additional technical parameters of products/ work , referAnnexure \"A\" attached with this BSR . |
| 10 | Supply & Laying following size earth strip in horizontal or vertical run in surface bymeans of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointingshall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nutbolt & spring washer spaced at 50cm making connection etc. as required.All as per preapproved by Engineer in-charge. For additional technical parameters of products/ work ,refer Annexure \"A\" attached with this BSR . |
| 11 | Supplying and making one end termination with Nickel plated heavy duty brass singlecompression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, GlandBody, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy dutyaluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape asper IS 8337-1976 of following size of PVC insulated & PVC sheathed/ XLPEaluminium conductor cable of 1100 volt grade as required.All as per pre approved byEngineer in-charge. For additional technical parameters of products/ work , referAnnexure \"A\" attached with this BSR . |
| 12 | Supplying and making one end termination with Nickel plated heavy duty brass singlecompression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, GlandBody, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy dutyCopper lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tape for followingsize of PVC insulated & PVC sheathed/ XLPE copper conductor cable of 1100 voltgrade as required.All as per pre approved by Engineer in-charge. For additionaltechnical parameters of products/ work , refer Annexure \"A\" attached with this BSR . |
| 13 | MAIN CUBICAL PANEL / STREET LIGHT CONTROL PANELP/F testing & commissioning of kiosk type weather proof out door maincubical panel size 750 mm X 1250 mm X 500 mm (app.) made out of 14gauge MS sheet front and back both side openable duly hinged door withlocking arrangement by providing both side held draft and all required hardwares. The cubical should be dust and vermin proof followed by coat ofzimpholite primer and finally two coats of enamal gray paint. The cubicalshould be mounted with hard ware on angle iron frame size 50 X 50 X 6 mmand 1500 legs duly painted framed be grouted 750 mm below ground levelwith cement concrete 1:3:6 in 1000 X 500 X 600 mm and providing brickmasonary along angle iron frame above G.L. They shall be in two section Please Enable Macros to View BoQ information |