| Sl. No. | Item Description |
| 1 | Taking down carefully aluminium / copper point wiring any type for one light , fan, socket power point controlled by one switch complete including fitting / fixtures such as switches, ceiling roses, holder, socket etc; and making good disturbed surfaces of walls, ceilings etc |
| 2 | Material and labour for point wiring for one light/fan/exhaust fan controlled by one way switch with 1.5 Sqmm PVC insulated unsheathed two single core multi-stranded copper conductor (FRLS) cable, 1100 Volts grade drawn through and includingPVC casing and capping of size 30/32 mmfixed to wall ceiling including PVC closed recessed boxes ISI markedwith 3.00 mm thick plastic laminated sheet top cover or cover plate of modular complete for mounting of switches, sockets etcincl1.50 sqmm (nominal area) PVC insulated and sheathed multistranded copper conductor cable FRLSH 1100 volts grade single core earth continuity conductorconnected to common earth dolly all as directed and specified for the followings. |
| 3 | One light /fan point controled by one 5/6 Amp piano type switch |
| 4 | One 3 pin socket outlet 5 Amps on same board. |
| 5 | One 3 pin socket outlet 5 Amps on indpendent board |
| 6 | All as per item No 2here in before but point wiring with 2.5 sqmm FR multi stranded copper conductor cable for main circuit and 2.5 sqmm cable as earth continuity conductor for one 15 Amp socket out let controlled by one 15 Amp switch on independat board, complete all as specified and directed. |
| 7 | S&F in replacement of switch piano (flush button type) single pole, one way, 5 Amps complete all as specified and directed. |
| 8 | S&F in replacement of switch socket combination 2 in one, 3 pin , 5/6 Amps, 240 Volts flush type,complete all as specified and directed. |
| 9 | S&F in replacement of switch socket combination 2 in one , 3 pin, 5/6/16 Amps flush type complete all as specified and directed. |
| 10 | S&F in replacement of socket out let 2 in 1, 3 pin 5 Amps flush typecomplete all as specified and directed. |
| 11 | S&F in replacement of step type electronic fan regulator 120 wattsingle pole 240 Volts complete all as specified |
| 12 | Supply and fix in replacement Lamp holder PVC case body of Bakelite with back plate suitable for batten fittings,all as specified. |
| 13 | S&F LED lamp,6500K,900lm in white colour of 9/10 Wattbase cap B-22 with poly carbonate difusser and aluminium heat sink ,complete all as specified & directed. Make: Havells/Philips or equivalent. |
| 14 | S&F in replecement ofUltra slim LED light to new 36W, 6500 K LED recess mounted bakelite panel 2 x 2 luminaire suitable for surface/grid ceilingfor low ceiling applications complete with tube, driver and connecting cable including making electric connection to ceiling rose or connector including taking down old unserviceable luminaire, complete all as specified and as directed. Havells Cat part No.LHEBAEP7IW1W036 or equivalent Wipro/Philips |
| 15 | S&F in replacment of LED tubelight fitting 1x20Wattbattentype fitting4 feetlong aluminium extruded housingIP-20 ratedrated voltage 230 volts(operating range 140 volt to 270 volts) , 50Hzsystem wattage 20 Watt +/-10% ,system current not less than 102 mA ,power factor more than 0.95, systemlumen efficacy 100 lm /watt ,CCT 6500Kcomplete all accessories prewired and connecting electrically to ceiling rose using PVC insulatedand overallsheathedflexible copper conductor of size 0.75 sqmm3 core all as specidfierd and directed. Make Havells Cat part No. LHEXARP7SN1W020 or equivalent Philips/ Crompton |
| 16 | S & F in replacement of LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size |
| 17 | S&F in replecement of plug top, AC 230 Volts, 16 Amps complete all as specified and directed. |
| 18 | S&F in replecement of 1100 volts grade heavy duty cable PVC insulated aliminium conductor served with inner sheathing of PVC sheathed with stranded conductor 10 sqmm twin core cable flat or circular, complete all as specified and directed. |
| 19 | S&F in replecement of Sheet metal enclosure IP-43 double door for DBs(where MCBs arereqd) SPN 240 V, for 4 ways, complete all as specified. |
| 20 | All as per item no 17above but SPN 8 ways 240 volts completeall as specified and directed. |
| 21 | S&F in replecement of MCB SP 6 to 32 Amp, 240 volts complete all as specified. |
| 22 | S&F in replecement of MCB SPN 32-40 Amp, 240 volts 50Hz AC supply, complete all specified. |
| 23 | Taking down carefully ceiling fans at any height of any sweep/ make /model after disconnecting electric connection and dismantling andopening the body of ceiling fan and examine for repairs including servicing,overhauling, greasing etc and cleaning the complete body both internal & external parts with cleaning agent and renewal of minor spare parts such as split pins,cater pins,coupling bolt, capacitor holder,terminal adoptor, screws, nuts, spring washers for blade/body etc and replacement of components/accessories such as ball bearings, gun metal bushes, capacitor, canopy top & bottom, shackle clip assembly and assembling of all parts, remetalling of worn out shaft of fan cutting brazing machining and polishing to make the shaft suitable for fixing of new ball bearing and fixing ball bearing in replacement of bushing system in ceiling fan and assembling the same and testing to the engineer in charge to ensure smooth and noise free operation(bearing shall be measured and paid seperately) including hanging and fixing back in existing location and connecting of electrical connections and testing for its satisfactory performance complete all as specified and directed.(Note:- (i) Spare parts will be measured and paid separately under relevant item of schedule as supply only |
| 24 | (ii)Rewinding of fan motor,painting will be measured and paid separetly under relevant item of schedule. |
| 25 | (iii)Labour element for fixing of spare parts and removing old unserviceable items are deemed to be included in quoted rate. |
| 26 | (iv) All repair works will be carried out at ON site/ workshop E/M yardas directed by EIC. |
| 27 | (v)Repair works of fans should completed and refixed the same within 12 hours after receipt of complaint slip.If the complaint not attended /not completed on same day recovery will be done from RAR bill as follows: a) For first day Rs 200 b) For second day Rs 300 c) For next every day Rs 500 |
| 28 | All as per serial item No.01 here-in-before but for exhaust fan of size 300mm/450mm sweep |
| 29 | Material and labour for taking out and removing burnt copper winding, cleaning the armature, rewinding theceiling fan (1200/1400mm sweep) armature/motorwith new super enamelled copper wire of existinggauge including supply and fixing necessary E class insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing all as specified and as directed. |
| 30 | M&L for rewinding of heavy duty exhaust fan motorof300mm/450mm sweep of any make/model/type with new supper enamelled copper winding wire ofsimilar gauge and number of turns and assembling of fan motor and rotor and testingincluding removing burnt out copper winding wire from fan motor complete all as specified and directed. |
| 31 | Supply only gun metal bush suitableforceiling fan/Exhaust fan/Air circulator fan /wall mounted fan of any sweep/type of any size(Make - TATA/MSP). |
| 32 | Supply only Ball bearing No.6201/6202/6203/6204 for ceiling fan (Make - TATA/SKF /NBC/NRB). |
| 33 | Supply only fan condensor 2.5 mfd,230 volt,AC 50Hz confirming to IS 1709 for ceiling fan,exhaust fan,wall mounted fan and pedestal fan (Make - USHA/UNIVERSAL/Havells) |
| 34 | Supply only fan condensor 3.15 mfd (Make - USHA/UNIVERSAL/Havells) |
| 35 | Supply & fixing Electronic fan regulator stepped typewith five step ,two module, 100Watt 240 voltscomplete all as directed. |
| 36 | Supply,fixing and testing of BEE 5 star rated super energy efficient ceiling fan with double ball bearing ,1200mm sweep,having 3 blades,down rod, canopies, shackles, 230volt, single phase suitable for input voltage range140-285 volt AC,50Hz with minimum air delivery of 210 CMM, Including connecting it through 1.5 Sqmm 3 core cable upto ceiling rose mount complete all as specified and as directed. Make : Havells Efficiencia Neo BLDC SKU Code: FHCNF5SWHT48 or equivalent Crompton Or orient. |
| 37 | Comprehensive repair/maintenance of storage type electric water heater (Geyser ) vertical or horizontal type of capacity 25-35 Ltrs comprising of the following :- |
| 38 | (a) Inspection, taking down , opening or dismantling, de-scaling,brushing and thoroughly cleaning the storage tank up to the satisfaction ofthe Engineer-in-charge. |
| 39 | (b) checking of all stop cock, pressure release valves, fusible plugs for its serviceability etc. in situ to ensure free movement of the parts including supply and replacing the washers/gasket nut etc. |
| 40 | (c) Checking and rectify earth continuity of the Electrical circuits of theGeysers and power point. |
| 41 | (d)Checking,and re-fixing thermostat and re-adjust. |
| 42 | (e) De-scaling the immersion type heating element and siphon assembly with diluted Hydro chloric acid or clear pedette solution. |
| 43 | (f)Checking of indicator lamp for it serviceability . |
| 44 | (g)Re-assembling the Geyser, re-install and testing complete. |
| 45 | (h) The rate for above ietm are deemed to include for transportation of geyser to the work shop as approved by Engr-in-Charge for necessary repairs and testing of Geyser at workshop. |
| 46 | (j) All repair works will be carried out at ON site/ workshop E/M yardas directed by EIC.. |
| 47 | (k)Repair works of geysers should completed and refixed the same within 12 hours after receipt of complaint slip.If the complaint not attended /not completed on same day recovery will be done from RAR bill as follows: a) For first day Rs 200 b) For second day Rs 300 c) For next every day Rs 500 |
| 48 | Note : Parts / components of geysers found unserviceable shall be replaced by the contractor. New parts/components required shall be measured and paid separately under item here-in-after as supply only and labour charges required for replacement are deemed to be included in the quoted rate ofitem |
| 49 | Supply only thermostat(Adjustable type) ofRod/stem Type EST-11EM,20A resistive , 250Volt, opening on temperature riseof approved make and having ISI mark all as specified. |
| 50 | Supplyonly steel inner tank suitable for storage type water heater (geyser) 35 litre capacity. |
| 51 | Supply only steel siphon geyser assembly 6/9 hole suitable for 25 ltr or 35 ltr capacity geysers any make as required at site of approved make complete with inlet and outlet and provision for thermostat pipe with drain pipes with drain plug, screws, studs, clamps for fixing heating elements etc. including gasket all as specified and as directed |
| 52 | Supply only heating elements of capacity 1.5 KW AC 240 volts suitable for storage type electric water heater as per site requirement (press type /screw type/triangular/circular base or ceramic cartige type),ISI marked all as specified and as directed. |
| 53 | Supply only glass wool for geyser 35 litres capacity all as directed. |
| 54 | Supply only gasket of thickness 5mm for geyser assembly of 09 holes/09 holes complete all as specified and as directed. |
| 55 | Supply & fixingPVC connection pipe 15 mm dia, 450mm long with end nuts and washer, suitable for cold/hot water outlet of geysercompleteall as specified and directed. |
| 56 | Supply only safety valve suitable for 25 ltr or 35 Ltr geyser all as specified and as directed. |
| 57 | Supply only non return valve 15mm bore as in replacement of old one and connection and testing complete all as specified and as directed. |
| 58 | Supply and fixing of plug top 3 pin 16 Amps,240 volts. |
| 59 | S&F of exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m including all connection complete all as specified and directed. |
| 60 | M&L for replacement of under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 50 sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testingincluding disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed.Note:- Excavation and earth, sand coushioning and protection for cable work shall be measured and paid separately. |
| 61 | All as per item No. 1 here-in-before but cross-sectional area 35 sqmm, 3.5 core complete. |
| 62 | All as per item No. 1 here-in-before but cross-sectional area 16 sqmm, 4 core complete. |
| 63 | M&L for GI pipe 40 mm dia \"light grade\" ISI marked, laid in trenches/ on floors/on, pole/road for cable protection including necessary joints / fittings including taking up / down and removing old unserviceable GI pipe complete all as specified and directed . |
| 64 | Excavation in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for Pole, shafts, cesspits, manholes, pier holes, etc and getting out of any type of soil complete all as specified and directed. |
| 65 | All as per Item No: 5 above but depth exceeding beyond 1.5mtr and not exc 3 metre all as specified and as directed |
| 66 | Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 67 | Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed. |
| 68 | Material and labour for sand cushioning with fine dry unwashed sand in trenches for protection of cables complete all as specified and directed. |
| 69 | Material and labour for well burnt bricks,Sub class \"B\" bricks, best quality locally available laid flat, dry in trenches for cable protection complete all as specified and as directed |
| 70 | M&L for PCC 1:4:8 type D-2using 40mm graded crushed stone aggregate as in foundation of poles etc including necessary form work, complete all as specified& directed. |
| 71 | M&L for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as incoping of pole etc including necessary form work, complete all as specified & directed. |
| 72 | Supply, fixing and erection of steel tubular swaged pole 09 m long, type 410 SP-32, weight not less than 154 kgs, pole should be in one piece only and smooth finishing, ISI marked conforming to IS:2713-1980, complete with all accessories, such as cast iron base plate, finial taper plug, bolts, nuts, screws, washers and drilling of holes for continious GI earth wire as specified including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer and embedded portion shall be painted with two coats of black paint after preparation of surface including taking down old unserviceable pole complete all as specified and directed.Note:-Excavation and earth work shall be measured and paid separately. |
| 73 | Detecting the fault of LT 440 volt overhead/ underground system of any feeder/location with necessary safety,testing equipment, tools and plants and rectify the defects on top priority basis/ as and when required including testing on completion, complete all as specified & directed. |
| 74 | M&L for replacement of 1100 volts grade heavy duty cable PVC insulated aliminium conductor served with inner sheathing of PVC sheathed with stranded conductor 10 sqmm twin core cable flat or circular, complete all as specified and directed. |
| 75 | M & L for pole painting 9.0 mtr long with two coat of aluminium paint after preparation of old painting surface by scrappining including marking of black and yellow strip not less than 30 cm width with sythethic enamelled paint from couping to upto height 1.5 mtr of pole alternative way including necessary `MES & Pole number to be wriiten in the circular yello batch on the pole all as specified and directed. |
| 76 | M&L for replacement and testing moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, ,4 Pole,415 volts,50Hz,breaking capacity 16KA,rating 63Amp,complete as per OEM standard design,all as specified and as directed by the Engineer in charge. |
| 77 | All as per item No. 17 here-in-before but rating 100Amp & breaking capacity 16KA. |
| 78 | All as per item No. 17 here-in-before but rating 160Amp & breaking capacity 36KA. |
| 79 | Repair to LT panel by disconnecting all connections for incomming and outgoing cables and making alternate arrangement for power supply to the unit/Qtrs and repairing to LT panel by providing locking arrangement and hinges for doors through out the length of panel by welding cutting, screws etc all as required at site including spray painting to the entire panel with smoke grey paint in two layers and refixing the incomming and out going cables with rethimbling with provision of new lugs complete all as specified & directed. |
| 80 | Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x600mm x 6mm thick buried dirctly in ground with earth pit not lesss than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 25 x 4 mm earthing lead by means of nuts bolts check nuts GI washers earth wire protected by GI pipe 32 mm bore, light grade, including concrete pit in PCC (1:3:6) type C1 of size 45x45x45 cm, precast RCC (1:2:4) type B1 as cover of size 40x40x10 cm with one handle for lifting made out of 8 mm dia MS bar, GI funnel wire mesh, 20 mm bore GI pipe, medium grade, for watering, charcoal or coke and salt packed all around in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part-I including testing on completion including demolition to existing one complete all as specifed and directed. (Note :- (i) PCC pit, RCC pit cover, GI earth protection & watering pipe, funnel, earth strip upto 7.5 Mtr etc shall deemed to be included in the unit rate. |
| 81 | Servicing of DG Set 62.5 KVA of any Make, checking entire system as per manufacturer\"s catalogue such as checking all parts for serviceablility, taking down defective parts such as fuel filter assy, by pass filter assembly, lub oil filter assembly, air cleaner assy,air filter, flexible hose pipe, radiator coolant , distilled water, Tightening the base bolt and nuts and mounting bolts and nuts. etc and replacing the same with same size & make and capacity of parts, draining out the old used burnt engine oil from the sump, cleaning all serviceable filters and oil sump with cleaning solution such as petrol/ diesel and refilling new engine oil upto required level, cleaning of battery terminals with warm water ,Checking the radiator and radiator hose and arresting small leaks ,Checking the fuel pump timing, adjusting if required and complete reassemled and including testing to DG Set to entire satisfaction of Engr-in-Charge. Note:-(i) Spare parts/ Engine oil/ check kit/ filter shall be measured and paid saperately under respective items of BOQ (ii) Minimum 6 months gap/ 200 hrs of run whichever is earlier shall be considered for next service(iii) Repair Guarantee for replaced parts/servicing of DG Set shall be for six month/200 hrs from the date of service. (iv) Cost of small spares required for maint of DG set shall be deemed to be included in the unit rate quoted.(v) Service Engineer must be skilled and must have knowledge of maintenance of DG sets and attending minor and major fault when it arise.(vi) Contractor shall attend and rectify the Malfunction in DG Set within 12 hours of breakdown, failing which a recovery of `Rs 1000/hourshall be effected. |
| 82 | Supply only Air filter (OEM) suitable for 62.5 KVA Capacity |
| 83 | Supply only Diesel filter (OEM manufactured ) with\"O\" ring (Primary& secondary) suitable for 62.5 KVA Diesel engine |
| 84 | Supply only Oil filter (OEM manufactured ) with\"O\" ring suitable for 62.5 KVA Diesel engine |
| 85 | Supply only banded cogged belt (OEM manufactured) suitable for 62.5-100 KVA Diesel engine |
| 86 | Supply only V belt (OEM manufactured) suitable for 62.5-100 KVA Diesel engine |
| 87 | Supply only fuel pipe (OEM manufactured) suitable for 62.5-100 KVA Diesel engine |
| 88 | Supply only silencer assembly (OEM manufactured) suitable for 62.5-100 KVA Diesel engine |
| 89 | Supply only rubber hose for air intake (OEM manufactured) suitable for 62.5-100 KVA Diesel engine |
| 90 | Supply & pouring in sump/topping up of Engine oil of grade 15W-40/20W-50 in engine or replacement of EngineMake - Servo/Castrol/IOCL/HPCL |
| 91 | Supply only coolant for radiator of any make any type DG set at various loactions all as directed by Engr-in-charge |
| 92 | Taking down brunt unserviceable Automatic Voltage Regulator assy from alternator of DG set by disconnecting its electrical connections, supply and fixing new AVR 12V suitable for 62.5-100 KVA DG Set including connecting all electrical connections. Testing voltage after starting engine and setting properly if a difference all as specified and directed. |
| 93 | Suply and fixing in replacement of free lead acid battery 12 volts 150 AH confirming to IS 7372 complete all as specified and as directed. |
| 94 | Taking down / Dismantling unserviceable self starter 12 volts from engine of DG Set , opening of stator and armature for repairing by replacing the worn outcarbon brushes, brush holder, bearings, ignition / solenoid coil, replacement of burnt armature, rewinding of field coils, replacement of pinion gears,bushingetc, complete servicing , varnishing of stator /armature and refixing after repair, testing / commissioning complete for DG Set any capacity complete all as specified and as directed. |
| 95 | Taking down the existing self starter up to capacity up to 62.5 KVA KVA Diesel engine and fixing self starter same as per existing model including testing after complete installation all as directed and specified. |
| 96 | Disconnecting incoming / outgoing cable connection from alternator of DG set and taking out from DG set room checking carefully and transporting to auth workshop aproved by AGE(I) for repair and rewinding of alternator dismantling into parts and cutting the burnt/damage copper winding wire from alternator / stator cleaning slots and rewinding the stator/alternator with super enamelled copper winding wire of existing gauge & size and insulation paper etc complete varnishing of rewinded alternator replacement of carbon brush set bearing set etc complete and transporting the alternator to DG set room coupling with DG set and testing complete including water load test all as specified and directed for Capacity of 62.5-100 KVA Alternator 415V, 50Hz.NOTE: All neccessary T&P for dismantling,transporting and installation cost is deemed in this work |
| 97 | Taking down the existing turbo charger unit from the capacity up to 70 KVA Diesel engine, Transporting to auth workshop aproved by AGE(I). Dismantling opening including replacement of worn out bearing, bushes, fanblade, gaskets, o ring, seal etc., and reassembling testing/ connecting complete all as specified and as directed . |
| 98 | Disconnecting, removing and dismantling radiator assembly from the following capacity DG sets and descaling the radiator throughly with CTC solution/ any other chemical solvent agent as approved by the Engineer-in-charge, stopping of leakage at place to copper cores and tubes by brazing scrapping the existing oil paint, dusting and painting the radiator with enamelled paint etc., re-installing and commissioning complete all as specified and as directedfor the Capacity of 62.5-100 KVA. |
| 99 | Taking down the existing defective injector and fuel injection pump (FIP) for the capacity of 62.5-100 KVA DG set installed at various installation and replacement of worn out spares like delivery valves, nozzles, bearings, fly weight, packing kit, and copper washer kit ,injector element,kit injector,retainer injector cup, fixing tappit cover packing set,and recalibration of FIP and refixing in same position and testing of full load checking of pressure and adjustment by dial gauge complete all as specified and as directed . |
| 100 | Dismantling old unserviceable battery charging dynamo of rating 12 volts and supply and fixing new battery charging dynamo same as per existing model suitable for fixing on DG set, 1500 RPM including testing after complete installation all as directed and specified. |
| 101 | Supply and fix replacement of generator control unit as per sample all as directed and specified. |
| 102 | Servicing/ overhauling of centrifugal pump, monoblock motor pump set up to the capacity of 1-2 HP 3 phase, 415 V, 50HZ induction motor including carrying out maintenance check along with following repairs :-(a) Opening of the defective motor in MES yard / pump house/ workshop, cleaning the covers and parts as applicable in presence of Engineer-in-Charge to ascertain the quantum of defects and repairs involved and carrying out the needful repairs including replacement of defective unserviceable parts like Body Spacer Bush,Gland shaft sleeve (SS), Ball/Thrust bearing as per existing size, O Ring, oil seal, Ball/Thrust DE bearing, Thrust plate set of CI, Brg bracket, neck ring, Body bush, stud with nut, repair pump shaft, Gland Bush withgland plate, gland packing, coupling set with bolt etc.(b) Assembling the pump motor after repair. (c) Spray painting the repaired motor externally with two coats of synthetic enamelled paint of shade as approved by the Engineer-in-Charge.(d) Contractor shall be repaird pump set within 2 days failing which a recovery of `Rs 2000/day shall be effected.(e) Transporting the repaired motor to MES yard/ workshop and carrying out necessary test in presence of Engineer-in-Charge to establish the functionability of the repaired motor up to the entire satisfaction of the Engineer-in-Charge. |
| 103 | Rewinding of stator ofinduction motor working on 3 phase, 440 volts, 50HZfor centrifugal/monoblock motor pump set of capacity 1-2 HP with bare copper winding of appropriate gauge recommended by OEM and as approved by Engineer-in-charge, complete all as specified & directed. Make of wire : Atlas / Devidayal |
| 104 | Material and labour servicing and cleaning of oil cooled servo voltage stabilizer capacity up to 100 KVA by transporting to workshop, carefully lifting of core from the tank by opening cover, cleaning of tank, removing of sediments, cleaning of coils/ electrical connections, filtration of transformer oil, fixing the core back in the tank, making electrical connections by replacing the consumble spares such as gaskets, rubber oil seals completeetc but other spares as listed here-in-after shall be replaced and cost of spare parts as\" supply only shall be measured and paid separately under relevent item iron padling back at work site ,working electrical connection all complete as directed by Engr-in-charge. Note: (i) Spare parts required to make serviceable of above oil cooled sevo voltage stabilizer shall be measured and paid separately under relevant item here-in-after.(ii) Contractor shall attend and rectify the breakdown in servo voltage stabilizer within 24 hours failing which a recovery of `Rs 1000/hourshall be effected. |
| 105 | Supply only dimmerstate unit of capacity up to 100 KVA servo voltage stabilizer 28 amps of Make Volina complete all as specified and directed. |
| 106 | Supply only main transformer of capacity up to 100 KVA servo voltage stabilizer of make Volina complete all as specified and directed. |
| 107 | M&L for replacement of Electronic circuit board (Printed circuit board) for controlling of synchronous motor of torque 10 KG and auto/manual under voltage high voltage operation. |
| 108 | M&L for replacement of PCB holder. |
| 109 | M&L for replacement of trigger transformer. |
| 110 | M&L for replacement of digital volt meter 72 x 72mm. |
| 111 | M&L for replacement of servo motor 10 KG torque. |
| 112 | M&L for replacement of RC network for 10 KG servo motor |
| 113 | M&L for replacement of auto manual switch. |
| 114 | Material and labour for filling in with new transformer oil for top up to voltage stabilizer having low viscosity of approved make as per IS 355 of 1992 and di-electric strength 40 KV(after filtration) complete all as specified and directed by Engineer-in-Charge. Make : Savita/Castrol |
| 115 | S & F in replacement of Off load change over switch 63 amps 415 volts 4 pole 50 Hz in sheet metal enclosure with out side handel operated complete all as directed by Engr-in-Charge. Make: Havells cat no IHBFFE0063 or equivalent cat part of make as specified in list of Approved make here-in-after. |
| 116 | S & F in replacement of Off load change over switch 100 amps 415 volts 4 pole 50 Hz in sheet metal enclosure with out side handel operated complete all as directed by Engr-in-Charge. Make: Havells cat no IHBFFE00100 or equivalent cat part of make as specified in list of Approved make here-in-after. |
| 117 | M&L for replacement of GI bracket for fixing of street light fittings bend to shape, made out of40/50 mm dia GI pipe medium grade suitable for fixing of Light upto 1.2 mtr long fixed with and including two sets of MS clamp made out of Flat iron of size 50x6 mm, fabricated to shape and fixed with nuts, bolts & washers & two coats of aluminum paint over a coat of red oxide primercomplete all as specified and directed by Engr-in-charge. |
| 118 | M&L for replacement of wiring with two nos single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm as in continuous earth wire drawn into steel pole for connection to security lights from junction box fitted on pole complete all as specified and as directed by the Engineer in charge. |
| 119 | M&L for replacement of junctionboxhot press moulded SMCof inside dimension size 333 x 233 x 120 mm with locking arrangements consisting of necessary suitable arrangements for incoming & out going cables with cable glands & having aluminium bus bar4 strips of 20x3mm for TPN on necessary epoxy base insulator andfixing of 6 Amp MCB SP, including necessary 25x3mm flat iron clamps with nuts, bolts & washers all as specified and directed. Make- Sintex GSJB3020 |
| 120 | M&L for replacement of Integral LED security light luminaire 60W LED 230 volts made of pressure die cast aluminium housing powder coated with high power SMD LED’s lens & toughned glass IP-66, Luminaire efficacy >=125 Lumens per Watt,Secondary optics for better light distribution, having two nos Potted driver(OEM)(one inbult and one spare potted driver) 4KV internal +10KVSPD, THD<10%, pf>0.95 and taking down old unserviceable light fittings any type/wattage complete all as specified and as directed. Make: HPL cat ref No.HPLLEDSL60CWEGLA or equivalent Philips or wipro |
| 121 | M&L for replacement of Integral LED security light luminaire 90W LED 230 volts made of pressure die cast aluminium housing powder coated with high power SMD LED’s lens & toughned glass IP-66, Luminaire efficacy >=125 Lumens per Watt,Secondary optics for better light distribution, having two nos Potted driver(OEM)(one inbult and one spare potted driver) 4KV internal +10KVSPD, THD<10%, pf>0.95 and taking down old unserviceable light fittings any type/wattage complete all as specified and as directed. Make: HPL cat ref No.HPLLEDSL90CWEGLA or equivalent Philips or wipro |
| 122 | Deduction to be made from BOQ for schedule of credit (Sch \"A\" Part - II) Amount of ₹ 39,677.00during AOCNote:- Tenderers shall not quote for this Schedule |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail