| 1 | M&L for dismantling Geyser of 25/35 Ltr capacity of any type from exiting position for descaling, removing its accessories removing the scale (white presipated) deposited in it, cleaningthe inner tank properly, painting with sparay gun and re-assembling the same and refixing to its existing location or new location with testingfor its proper functioning complete all as specified and directed.Note: If any spares required then supplied and measured separately under relevant item. |
| 2 | All as per Srl item No 1.00 above but for 50/100 Ltr Capacity complete all as specified and directed. |
| 3 | Supply only inner container suitable for vertical type geyser 25 ltrs storage capacity including taking down of defective container complete all as specified and directed. |
| 4 | All as per Srl item No. 3.00 above but for 50 Ltr Capacity complete all as specified and directed. |
| 5 | All as per Srl item No. 3.00 above but for 100 Ltr Capacity complete all as specified and directed. |
| 6 | S&F in repair thermostat 0-80 Degree as per exiting size including taking down of defective thermostat complete all as specified and directed. |
| 7 | S&F of heating element 1000/ 1500 watt with studs, bolts, rubber washer suitable for existing type (triangular/ round) of geyser including taking out of old unserviceable element complete all as specifed and directed. Make : Bajaj/ Racold/ Venus or equivalent as approved. |
| 8 | All as per Srl item No 7.00 above but for 2000 watt, complete all as specified and directed. |
| 9 | S&F in repair Indicator lamp with flexibe copper wire of suitable size Red/ Green including taking down of defective indicator lamp, complete all as specified and directed. |
| 10 | S&F stainless Steel grade chromium finish connection pipe 15 mm dia with adopter, washer 450 mm long including making in shape complete all as specified and directed. |
| 11 | S&F PVC connection pipe, 15mm dia, 450mm long with brass adopter & washer on both sides complete all as specified and directed. |
| 12 | S&F Non return valve, 15 mm dia brass/GM, ISI marked, complete all as specified and directed. |
| 13 | S&F apperture plate SS suitable for 25/50 ltrs geyser along with rubber gasket, nuts, bolts, etc., complete including taking down of defective apparture plate complete all as specified and directed. |
| 14 | S&F combined Apperture plate SS with thermostat & element complete as per existing type suitable for 25/ 50 ltrs geyser along with rubber gasket, nuts, bolts, etc complete including taking down of defective apparture plate, complete all as specified and directed. |
| 15 | S&F in repair hot water pipe insulation with glass wool and aluminium cladding 20/25/40 mm bore including all material complete as per OEM recommendation completeall as specified and directed |
| 16 | S&F to walls , floorand ceiling 25 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 with and including taking down existing unserviceable complete all as specified and as directed. |
| 17 | All as per Srl item No.16.00 above but for size 20 mm bore complete all as specified and directed. |
| 18 | All as per Srl item No.16.00 above but for size 15 mm bore complete all as specified and directed. |
| 19 | S&F stop valves, 20mm cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 20 | All as per Srl item No 19.00 above but for fancy type, chromium plated with long shank and cup (concealed type) complete all as specified and as directed. |
| 21 | S&F 15mm bore gun-metal, globe or gate valves, with iron wheelhead, screwed both ends for ironpipe and fixed complete all as specified and directed. |
| 22 | All as per Srl item No. 21.00 above but of size 20 mm bore complete all as specified and directed. |
| 23 | All as per srl item No. 21.00 above before but of size 25mm bore complete all as specified and directed. |
| 24 | S&F plug top, 3 pin, 15 Amp, 230 volts, complete all as specified and directed. |
| 25 | S&F Metal Plug top, 3 pin, 15 Amp, 230 volts, complete all as specified and directed. |
| 26 | S&F in PVC insulated and sheathed 3 core copper conductor cable of size 2.5 Sqmm 3 core suitable for geyser complete all as specified and directed. |
| 27 | S&F Single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB with 240 volt, 20 amps, including taking out complete all as specified and directed. Make : L&T/ Legrand/ Schneider or equivalent as approved. |
| 28 | S&F MCB SP (single pole) 06 to 32 Amps, \"B\" Curve, with 10 kA for inductive load connected through cable lugs of suitable size complete all as specified and directed. Make: L&T/ Legrand/ Schneider or equivalent as approved. |
| 29 | S&F fastner for fixing of gyeser in existing wall, suitable size minimun 4 \"(02 Nos) complete all as specified and directed. |
| 30 | M&L for point wiring 1.5 Sqmm (nominal cross sectional area) with colour coding multistranded copper conductor cable, PVC insulated (FRLS-H) and unsheathed cable and including drawn through PVC casing – capping size of 25x32 mmwiring with all fittings and accessories, terminated to sunken box and laminated sheet of suitable size for housing/mounting the switches/sockets including 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor cable earth wire connected to common earth dolly for one point on independent board control by one, one way switch 5 Amps, complete all as specified and directed. |
| 31 | All as per Srl item No 30.00 above but for one 3 pin 15 Amps power point on independent board with 2.5 Sqmm complete all as specified and directed |
| 32 | S&F switch piano flush single pole, one way 5 Amp ( ISI marked)complete all as specified and directed. |
| 33 | S & F switch piano flush single pole, one way 15 Amp ( ISI marked)complete all as specified and directed. |
| 34 | S&F socket (ISI Marked) 2 in 1, 3 pin 5/6 amps flush type complete all as specified and directed. |
| 35 | S&F socket 2 in 1, 5 pin 5 and 15 amps (ISI marked) flush type universal, complete all as specified and directed. |
| 36 | M&L for rewinding/ repairing of blower fan motor of water coolerby disconnecting the electrical connection of burnt out electric outdoormotor of any make/model incl transportation to and for, taking out burnt out winding carefully and rewinding with high quality super enamelled copper wire of existing gauge & size including insulating material and varnish, bush, shaft, bearing etc complete for motor of suitable capacity includingremoval and re-fixing of the samecomplete all as specified and dierected.Make of motor to be repaired as per sample. |
| 37 | S&F in repair Compressor for Split AC 2 TR as per sample including taking down of defective compressor complete all as specified and directed. |
| 38 | Supply & chargingR-32 /22 gas for AC etc and other appliances (including Cylinder 5 KG) complete all as specified and directed. |
| 39 | Supply & chargingR-410 gas for refrigerator /Deep Freezer /etc and other appliances (including Cylinder 5 KG), complete all as specified and directed. |
| 40 | Supply & chargingR-134a gas forwater cooler and other appliances complete all as specified and directed. |
| 41 | S&F in repair starting Capacitor of capacity suitable existing size ±5%, 220V, AC, 50 Hz including taking down of defective capacitor complete all as specified and directed. Make : - GC / Universal / Havells / Epcos / Tibcon or equivalent as approved. |
| 42 | S&F in repairstarting Capacitor of capacity suitable existing size ±5%,, 220V, AC, 50 Hz including taking down of defective capacitor complete all as specified and directed. Make : - GC / Universal / Havells / Epcos / Tibcon or equivalent as approved. |
| 43 | S&F in repair Copper refrigerent piping size 1/4\" or 3/8\" suitable for cooling appliances including taking down complete all as specified and directed. |
| 44 | S&F in repair Copper refrigerent piping size 1/2 or 5/8\"suitable for cooling appliancesincluding taking down complete all as specified and directed. |
| 45 | S&F in repair Capillary tube suitable for cooling appliances including taking down complete all as specified and directed. |
| 46 | S&F in repair water cooler 40/80 Ltr complete all as specified and directed. Note: Old unserviceable one deposited to AGE E/M stor yard. |
| 47 | S&F in repair Compressor for water cooler as per sample including taking down of defective compressor complete all as specified and directed. |
| 48 | S&F in repair motorassemblyof 230 V, 50 HZ,(as per existing),as per sample suitablefor Water cooler of any make and capacity complete all as specified and directed. |
| 49 | S&F in repair Capacitor suitable for water coolers aluminium body, 440V, AC,50 Hz including taking down of defective capacitor complete all as specified and directed. Make : - GC / Universal / Havells / Epcos / Tibcon or equivalent as approved. |
| 50 | S&F in repair Chromium plated Push cock including taking down of defective tap complete all as specified and directed. |
| 51 | S&F in repair Compressor suitable for refrigerator 1/6or 1/8 including taking down of defective compressor complete all as specified and directed. |
| 52 | S&F in repair PCB for suitable refrigerator of any make / capacity including taking down of defective PCB complete all as specified and directed. |
| 53 | S&F in repair Condenser coil suitable for Refrigerator of any make and capacity: including taking down of defective coil complete all as specified and directed. |
| 54 | S&F in repair Cooling coil with door and frame suitable for Refrigerator of any make and capacity including taking down of defective cooling coil complete all as specified and directed. |
| 55 | S&F in repair Thermostat switches suitable for Refrigerator of any make and capacityincluding taking down of defectivethermostat complete all as specified and directed. |
| 56 | S&F in repair Gasket set complete suitable for Refrigerator of any make and capacity including taking down of defective gasket complete all as specified and directed. |
| 57 | S&F in repair Compressor suitable for Deep freezer including taking down of defective compressor complete all as specified and directed. |
| 58 | S&F in repairDeep freezer capacityof any make and capacity including taking down of defective condenser complete all as specified and directed. |
| 59 | S&F in repair of PCB Kit AC/Refrigerator/ Deepfreezer etc after recitfication of PCB the same to be fix properly including making working condition complete all as specified and directed. |
| 60 | Comprehensive maintenance of AC/water cooler, Refrigertor & Deepfreezer, etcand repair including checking all parts and renewal / replacement of minor defective parts, Servicing and checking offan motor,Compressor Oil Charging, Suction,liquid Line, nitile rubber,Insulation, Insulation Tape Wrapping with tie, Drier Change, Gas Charging complete all as specified and directed. |
| 61 | Comprehensive maintenance of walk-in cold storageand repair including checking all parts and renewal / replacement of minor defective parts, Servicing and checking offan motor,Compressor Oil Charging, Suction,liquid Line, nitile rubber,Insulation, Insulation Tape Wrapping with tie, Drier Change, Gas Charging complete all as specified and directed. |
| 62 | M&L for Heat pillar any type 1500W high efficiency heating device with a chrome plated outer body and voltage of 220-230 V AC 50 Hz including 2 heating rod and oscillation speed of 5 8 pm complete all as specifed and directed |
| 63 | M&L for repair Heat pillar any capacity of any type from exiting position,checking all electical connections, heating rod oscilation fan, etc, if required minor repair like brazing, etc complete all specifiedand proper functioning complete all as specified and directed.Note: If any spares required then supplied and measured separately under relevant item. |
| 64 | S&F in repair heating rod 2 Nos suitable for heat pillar as existing type complete all as specified and directed. |
| 65 | S&F in repair oscilation fan with motor suitable for heat pillar as existing type complete all as specified and directed. |
| 66 | S&F in repair switch unit 3 Nos suitable for heat pillar as existing type complete all as specified and directed. |
| 67 | S&F in repair Body with base plate including guard suitable for heat pillar as existing type complete all as specified and directed. |