| 1 | Repair/maint of High Mast light fittings ,Jhumroo light fittings,flood light fittings, Gate light fittings, or any other fittings ofany types/make installedinbuildingunderroofonaheight upto 16 Mtr, fitted on pole etc. bymeansreplacinganyU/Spartsasandwhenreqdcompletewithlabourincluding dismantling,reassemblingand refixing thefittingatitsoriginallocation/ other locationswithproperalignmentandmakinggoodalldefects, replacing minorpartsas suchnuts,bolts/PVCconnection,insulation tapeetcandkeepthelightfitting in workingconditionsthroughouttheperiod of thecontractcompleteall asspecifiedand directed(Note-Burnoutpartsreplacedwillbe paid as supply onlyunderrelevant items) |
| 2 | Repair/maint of street lightfittings,Building light,Garden light, LED type (25 to 80 Watt) or any other fitting ofany types/make installedinpoleonheight upto 9 mtr/11mtrbymeansreplacinganyU/Spartsasandwhenreqdcompletewithlabourincluding dismantling,reassemblingand refixing thefittingatitsoriginallocation/ other locationwithproperalignmentandmakinggoodalldefects, including replacingminorpartsas suchnuts,bolts/PVCconnection, insulation tape, 2.5 sqmm 3 core wire upto 1 mtr (light fitting to pole connection)etcandkeepthelightfitting in workingconditionsthroughouttheperiod of thecontractcompleteall asspecifiedand directed(Note-Burnoutpartsreplacedwillbe paid as supply onlyunderrelevant items) |
| 3 | Supply onlyelectronic driver suitable for LED fitting of 25 to 60 watt complete all as specified and as directed. |
| 4 | Supply onlyelectronic driver suitable for LED fitting of 70 to 90 watt complete all as specified and as directed. |
| 5 | Taking down old unserviceable street light fitting any type and Supply and fixing70 Watt LED street light fitting with system lumen more than 7000, CCT 5700 K, 4K inbuilt surge protection, PF not less than 0.95 including all accessories with Pressure die cast aluminium housing with heat resistant toughened glass & IP66 protection.including suitable size galvanised iron 2 Nos clamps made of flat iron of size 25 x 6mm and suitable bolts and nuts with washers, incl PVC insulated copper conductor multi stranded 3 core 1.5 sqmm from fitting to OH line/up to looping terminal box complete all as specified and directed. |
| 6 | Supply and fixingof45W LED street light New generation energy saving & environmental friendly long life versatileIP 66 with Pressure die-castaluminium alloy for housing (heat sink) for effective thermal management and tempered protective toughened glass with IK07 rating and lens on the led chips and APFC driver, CCT 5700K, System Lumen efficiency 100 lumen/watt, inbuilt surge protection, PF not less than 0.95 including suitable size galvanised iron 2 Nos clamps made of flat iron of size 25 x 6mm and suitable bolts and nuts with washers, incl PVC insulated copper conductor multi stranded 3 core 1.5 sqmm from fitting to OH line/up to looping terminal box complete all as specified and directed. |
| 7 | Supply and fixingof 100W LED energy saving,environmental friendly, long life, exclusive innovativedie-castaluminium flood light with high power LEDs as light source incl necessary fixing arrangementwith IP65 protectionand PVC insulated copper conductor multi stranded 3 core 2.5 sqmm for connection complete all as specified and directed. |
| 8 | Supply and fixingof LED Gate Light with Dusk Dawn Sensors 25WIntelligent smart LED gate light with Dusk Dawn sensors that automatically switches on when ambient Lux Levels go below ~40Lux and switches off at lux levels above ~50 (Make- Shakti/ Havells/ Philips or any make approved by Engr-in-Charge) Model - SZPGPMX025-DDS complete all as specified and directed.Note for Item No 05 to 08 :-(i) All minor spares other than enumerated above such as insulation tape, connector, connectiing wire 3 core upto 1.5 RM, screws, nut, bolts, washers etc are required for proper installation of fitting is deemed to be included in the item rate.(ii) The ladder, T&P and safety belts etc as required for executing the work shall be provided by the Contractor and the rate quoted is deemed to be included for the same. |
| 9 | Material & labour in replacement of the two single / one twin core PVC insulated stranded aluminium conductor10 sqmm 1100 volts grade drawn in swaged steel poles for connecting the street light fitting from theterminal box provided at the bottom all as specified and directed. |
| 10 | Material & labour in replacement of the two single / one twin core PVC insulated stranded aluminium conductor 6 sqmm 1100 volts grade drawn in swaged steel poles for connecting the street light fitting from theterminal box provided at the bottom all as specified and directed. |
| 11 | Material & labour in replacement of thePVC insulated stranded copper wire1.5 sqmm 3 core 1100 volts grade drawn in swaged steel poles for connecting the street light fitting from theterminal box provided at the bottom all as specified and directed. |
| 12 | Supply and fixing in replacement automatic street light switchfor automatic swithcing of street light/high mast lightbased on lux level of natural light including the sensor alongwith suitable power contractor as per IEC - 60947-4-4 , MCB and support terminal andenclosed in pole/wall mounted factory made PVC enclosuremade out of rust , shock, termite proof and FR gradeconfirming to IP 54 of capacity 5 KW, Single phase , 240 Vof make Make- Kaktiya Energy system (model - SWADEEP 02EC 5kW1P or equivalent model of /philips/Havells) |
| 13 | Material & labour for factory made SMC junction box of size not less than 250mm x 200mm x 105mm as per sample and make approval by Engr-in - Charge with 4 Nos Aluminium Busbar of size 20 x 3 mm thick mounted on porcelin insulators with and incl MCB, \"C\" Curve SP 06 Amp - 01 Nos incl incoming and outgoing connections with necessary welding work, clamps and mounting on poles etc complete all as specified and directed. |
| 14 | Supply and fixing in repalacement of street light bracket made out of 40 mm dia light grade GI pipe bend to shape 1.2 m long with 02 Nos clamp made out of 25 x 6mm GI strip including drilling holes bending welding and made to clampes on building/concrete/Rail/Tubular pole and all as per specified and directed by engr in charge. |
| 15 | Supply and fixing in repair MCB SP 6-32 Amp 230V complete all as specified and directed by Engineer-in-Charge. |
| 16 | NOTE :- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs 13828.00 /- ] |