| 1 | Taking down carefully surface aluminium or copper point wiring on TW Batten/in conduit/ with PVC casing-caping/conduit(light, fan, socket, or power) complete and making good the disturbed surface of wall/celling etc including taking down fitting such asswitches, ceiling roses, pendants, regulators, sockets, light fittings etc and removing material from site and taking credit as per schedule of credit complete all as specified. |
| 2 | M & L for concealed Point wiring complete with 1.5 Sqmm (nominal area)1100 volts grade single core PVC insulated FR-LSH multistranded copper conductor cable in and including medium grade duty PVC conduit not less than 20 mm(wall thickness 1.5 mm ) including fitting & accessories, with sunken galvanized pressed steel terminal boxes with 3 mm thick laminated baklite (Hylum/Anchor) sheet top cover/modular sunken box with different module as required according to the site requirementfor mounting switch, socket etc for one light/fan/bell point controled by one switch and(Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm. stranded copper conductor with green FRLSH PVC insulating earth common earth dolly, complete all as specified. |
| 3 | All as per above item Serial No.2 One socket outlet 6 amp controlled by one switch on the same board with other switches |
| 4 | All as per above item Serial No. 2 One socket outlet 6 amp controlled by one switch on indepdendent board |
| 5 | All as above item No 02 but M & L Point wiring with 1100 volts grade single core PVC insulated FRLSH multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 2.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm diaISI marked with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for one 16 amp socket outlet controlled by one switch on independent board complete. |
| 6 | All as per Item No. 2.00 here-in-beforebut for one light point controlled by two numbers, 2 way switches. |
| 7 | S & F switch piano flush button single pole one way 5/6 amp complete. |
| 8 | S & F switch piano flush button single pole one way 16 amp complete. |
| 9 | S & F of switch piano, flush type, 5 amps, 230 volts, single pole, two way (ISI marked) complete all as specified |
| 10 | S & F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete. |
| 11 | S & F socket outlet2 in 1, 3 pin16 amp flush type complete. |
| 12 | M & L of lamp holder, PVC/ polycarbonate type complete and including taking down unserviceable lamp holder of any description complete all as specified |
| 13 | Supply and fixing in repair LED lights fitting 1 x 20 W, 220 V AC wall mounted LED batten housing made of Aluminium type connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complect as specifiedMake : Havells/ Crompton / Bajaj/Philips/ Orient Electric |
| 14 | Supply and fixing in repair LED lights fitting mirror type with high output diffuser 2 feet, 10Watt 220 V AC decorative type with driver holder and LED lamp housing of Aluminium type including connecting up withthree core flexible copper conductor cable of suitable sizecomplete all as specifiedMake : Havells/ Crompton / Bajaj / Philips/Orient Electric |
| 15 | S & F ceiling rose65x50mm 3 terminals polycarbonate body complete all as specified and as directed. |
| 16 | Supply and fixing fan regulator electronic step socket type type and making connection complete all as specified and as directed. |
| 17 | S & F for MCB DB SPN 8 waydouble door IP 43 complete prewired including Bus Bar with earth bar and neutral bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed . |
| 18 | Supply and fixing sheet steel metal enclosure (DB) triple pole and neutral 4 way Double Door 415 V, with 200 amps rated bus bar complete all as specified and directed. |
| 19 | Supply and fixing MCB\"s single pole and neutral 32 Amps, 240 Volts,10 KA rapturing capacity \"B\" curve.complete all as specified & directed. |
| 20 | Supply and fixing MCB\"s single pole 6 Amps to 32 Amps, 240 Volts,10 KA rapturing capacity \"B\" curve.complete all as specified & directed. |
| 21 | Supply and fixing 415 V , 10 KA \"C\" curve miniature circuit breaker (MCB\"s) of capacity 63 Amps TPN. complete all as specified & directed. |
| 22 | S&F in repair of bell AC single pole Ding Dong type 230 volt all as specified. |
| 23 | S&F of bellpush flush type 5 Amps complete all as specified. |
| 24 | S & F LED light fitting 1X10W bulkhead luminaires made of PDC Aluminium with opol diffuser IP 65 including LED light driver holderconnecting up with three core flexible copper conductor cable of suitable size complete all as specified Make Halonix |
| 25 | M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel wire 4mm dia as earth lead soldered and rivetedto earth plate by means of nuts, bolts, check nuts & washers, of galvanizediron or steelwith connected to test point and testing on completion including 15mm GI light grade pipe for earth leadprotection from earth point to earth plate, including provnadequate quantity of charcoal dust mixed with35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth platewith 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire meshwith and includingall necessary excavation& earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor. |
| 26 | Supply and fixing of single pole and neutral enclosure with a two pin and earth plug and socket complete with single MCB 20 Amp 240 V for geyser all as specified. |
| 27 | Supply and fix in replacement of modular switch6 amp 230 V AC one way, one module complete all as specified |
| 28 | Supply and fix in replacement ofmodular switch 15/20 amp 230 V AC one way, with indicator one module complete all as specified |
| 29 | Supply and fix in replacement ofModular Socket 6A, 2/3 pin two module combined complete all as specified. |
| 30 | Supply and fix in replacement of Modular socket, 16A, 2/3 pin, two module complete all as specified. |
| 31 | Supply and fix in replacement ofmodularfan regulatorstep type, 120W, 2 module complete all as specified |
| 32 | Supply and fix in replacement ofwhite colour plates withframe formodular switchof 01module complete all as specified |
| 33 | Supply and fix in replacement ofwhite colour plates withframe formodular switchof 03module complete all as specified |
| 34 | Supply and fix in replacement ofwhite colour plates withframe formodular switchof 04module complete all as specified |
| 35 | Supply only in replacement ofwhite colour plates withframe formodular switchof 06module complete all as specified |
| 36 | Supply and fix in replacement ofwhite colour plates withframe formodular switchof 08module complete all as specified |
| 37 | Supply and fix in replacement ofLED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified. |
| 38 | Supply and fixin replacement plug top 3 pin, 5 Ampscomplete all as specified and as directed. |
| 39 | Supply and fix in replacement plug top 3 pin, 15 Ampscomplete all as specified and as directed. |
| 40 | Supply and fix in replacement ofround shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete complete all as specified and directed, |
| 41 | Supply and fix in replacementof single corewire 2.5 Sqmm multi-strand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed. |
| 42 | Supply and fix in replacementof single corewire 1.5 Sqmm multi-strand PVC insulated copper conductor FRLS cable including connections of cable with MCBs or bus bars complete all as specified and directed. |
| 43 | Supply only Insulation tape 50 mtr long all as specified |
| 44 | Supply and fixing MCB\"s \"B\" curve Four pole 100A, 415 Volts,10 KArupturing capacity complete all as specified & directed. |
| 45 | Supply only in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor,served with inner sheathing of PVC tape and overall PVC sheathed in service connections 2 core 10 sqmm cable flat or circular all as specified and directed. |
| 46 | Supply and fix in repairPVC laminated ISI marked top cover sheet 3 mm thick including cutting/drilling holes for mounting of switches, sockets, etc as per site requirement suitable for following sizes of sunken/TW board.4”x4” size complete all as specified and directed. |
| 47 | -Ditto- all as per Item No 46 here-in-before but 7”x4” size complete all as specified and directed. |
| 48 | -Ditto- all as per Item No 46 here-in-before but 8”x6” size complete all as specified and directed. |
| 49 | -Ditto- all as per Item No 46 here-in-before but 8”x10” size complete all as specified and directed. |
| 50 | -Ditto- all as per Item No 46 here-in-before but 10”x12” size complete all as specified and directed. |
| 51 | Supply and fixing in repair/replacement LED building security light fitting 35 Watt 230 V AC out-door type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection,fixed to pole or wall of building with and including suitableBracket made out of25 mm dia GIlightgrade pipe, 1.20 m long bent to shape by cutting & weldingas required & directed and fixed withtwo Nos of FI clamps 50x6 mm to be tightened with suitable size of bolts, nut and washers and including painted withtwo coat of aluminium paint over a coat of red oxide primer, and including connecting the fittingto electric sourcewith & including twin twisted copper flexible wire of size 0.75 sqmm three core with suitable size flexible PVC conduitincluding all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed. |
| 52 | Supply and fix in repairpost top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp.complete all as specified and directed. |
| 53 | S&F in replacement Flame Retardant (FR) PVC casing caping of Size 25 mm x 16 mm, Ivory Colour, Unplasticised formulation for prolong storage or usage, double lock, ISI Marked as per IS 14927, Highly durability, Resistance to oil and grease, complete all as specified and directed. |
| 54 | S&F in repair LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption 18W (4 feet 18 W) luminaire lumen >1000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSIBin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification complete all as specified and directed. |
| 55 | S&F in repair LED wall bracket light 9 Watt, Aesthetically designed wall bracket in SS Housing, Glass and B22/E27 hldermodel No.HLWB-01-E27 make : Halonix or equivelent all as specified and directed.. |
| 56 | S&F in repair/replacement/installed integrated all in one Solar LED 20W Luminaire comes with in-built Solar Charge controller, Solar PV Module Battery LMLA (Low Maintenance Lead Acid) ,VRLA GEL, LI-ion, LifFePO4, batteries alongwith duke to dawn Auto ON/OFF and inbuilt Automatic dimming provided after dusk ON based on PIR sensing or SOC bases. AIO Solar light 150 lm/w system Efficacy and Hybrid 230V AC operation IP 65 mounting clamp as complect product ready to install over tubular or Octagonal pole OD 76-90mm.make : Halonix or equivelent HLSSLINT02A1270320-20W-WOP-CWL 20 Watt/18AH LEFEPO4 /50WP all as specified and directed.. |
| 57 | Attending of day to day electrical complaints pertaining to internalelectrification received through telephone/ Armaan or in person on detailment at MES Service centre located at Suranussi Areaby locating and rectification of fault from and including electric meter/DB onwards in respect of sub main/point wiring including provisioning of small pieces of electric cable of size 1.5/2.5 Sqmm to 10 Sqmm single core copper conductor and length not increasing 0.50 mtrs and fixtures for power and light socket/light, fan and bell etc complete and carrying out repairs to the extent of tightening of loose connections, disconnection anddismantling of faulty wires, battens, conduits, boxes, main switches, MCB\"s, DB\"s and other E/M fixturesincluding providing necessary screws / nuts / bolts / nailsfor the rectification of defect and refixing of existing dismantled serviceable items and replacement of defective items with new ones complete all as specified and directed. Note - (i) Contract will provide sufficient manpower for attend the complaint for daily basisfor the fixing/replacement of unserviceable item shall deemed to be included in item and cost of store replaced shall be measured as supply only against relevant Items.(ii) Complaint pertaining to location and rectification of fault in more than one length of point wiring/sub main wiring/DB\"s/fitting or fixtures etc shall be considered as an independent complaint. Similarly complaint pertaining to replacement oftwo fixtures in one Qtr will also be measured and paid as one complaint.(iii) Replacement of more than two fixtures/itemsbut multipleof three fixtures or part thereof in one Qtr/Bldg will be measured as an additional complaint.(iv) In case a Qtr/room is found locked when tradesman is detailed to attend the complaint, the complaint shall be treated as one till its completion.(v) Necessary tools for tradesman shall be provided by the contractor.(vi) Transportation for tradesman and normal stores required for complaints shall be arranged by the contractor.(vii) Complaints of normal nature shall be attended and rectified within 8Hrs of receipt of complaint. However, complaints of emergent naturei.e no light, short circuit, earth fault etc shall be attended immediately onreceipt of complaint round the clock. (viii) Bldgs requiring rewiring of small qty of point wiring if ordered will be measured and paid separately under respective items below(ix) Contractor will deposit all the items to EM Store in advance and unsv items will be collected by the contractor as schedule of credit(x) Tradesman will report to E/M complaint cell at 9 O\"Clock to 1700 hrs daily for collecting of complaints. Complaint received on Armaan application will be done in the same day and after completion of complaint Electrician will report to Armaan Cell for uploading the completion report.(xi) Contractor deploy local electrician for the job so that urgent nature of complaintlike no light, short circuit and earth fault will also done on Holidays/ Sunday. |