| 1 | Supply, installation, commissioning and testing of ECO friendly Diesel Engine driven silent type ,acoustic enclosure made out of CRCA sheet generating set outdoor type of capacity 82.5 KVA or nearest higher capacity, suitable HP , latest CPCB IV+ emission compliant 415 volts AC, 3 phase and neutral wire, 50 HZ, 4 wire, 0.8 PF, Governing as per manufacturer norms, noise level <75 dBA @ 1 mtr, fuel tank capacity as per manufacturer recommendation, electrical battery starting volt-24 V DC, directly coupled alternator, measuring display board etc common steel base fixed on cement concrete in foundation as per OEM recommendation platform with inbuilt AMF panel as per manufacturer recommendation and other accessories comprising of following :-Make-Genset model No CI82.5D5P(Engine cummins model QSB4.5-G1 and alternator model No stamford Frame No S2L1D-G41) DIESEL ENGINE ECO friendly, 4 stroke diesel Engine confirming to B/S standered developing suitable BHP @ 1500 RPM turbo charged water cooled complete with a provision of 10 % overload for 1 hour.(i) Fly wheel with starter ring for generating set.(ii) Dry type air filter.(iii) Lube oil cooler assembly with accessories.(iv) Exhaust air manifold.(v) Exhaust silencer(vi) Expansion bellow(vii) Exhaust gas turbocharger(viii) Fuel filter (pre micro)(ix) Oil filter(x) 12V or 24V DC as per manufacturer norms electrical starting system with starting motor & battery charging alternator with self starter and other auto electric accessories as recommended by manufacturer. |
| 2 | (xi) Centrifugal by pass filter(xii) Front and rear mounting support.(xiii) Engine control panel consisting of OFF/ON/START keys lub oil pressure gauge, Ammeter, Electric hour meter, speedo meter.(xiv) Safety against low lube oil(xv) Engine test certificate(xvi) Cold starting kit(xvii) Engine main manual with spare part list(xviii) Governer as per manufacturer norms(xix) Cooling radiator with first fill coolent.ALTERNATOR Silent pole brushless copper wound type suitable for direct couple to engine self excited, self regulated with fast response thyristor type electronic automatic voltage regulator with output voltage within desired limit(+1%) Dynamicaly balanced 415 V , AC, 3 PHASE, 50 Hz, 4 wire 0.8 PF lagging 82.5 KVA insulator class \"H\",1500 RPM star connected screen protected drip proof enclousers with radial fan mounted on rotor with insulated class H with following acessories :-(i) One MS frame suitable for mounting of Engine and Alternator.(ii) Fuel tank of suitable capacity as per manufacturer recommendation complete withfuel gauge inlet/outlet connections drain valve with plug etc.(iii) Battery of suitable capacity with copper leads and terminal leads of suitable size.(iv) One set of AVM pads fitted on base frame and exit of the container noise level shall be not exceed 75 dB at 1 meter distance as per CPCB norms. |
| 3 | (C) Acoustic Enclosure Supply and install of Acoustic Enclosure suitable for 82.5 KVADG set the degree of protection IP-42 confirming to IS-2147 as under:-(i) Fabricated out of CRCA sheet of suitable size as per manufacturer design. Polysterbased powder coated internaly and externaly with lockable type door handle. All nutsand handles shall be zinc coated.(ii) The door are gasketed with EPDM gaskets.(iii) Sound proofing with high quality rock wool/mineral wool confirming to IS 8183 of 50mm thickness and density at 96 kg/m³ covered with fiber glass cloth and perforated powder coats sheet specially designed allenuators (sound controller) at air entry(iv) Adequate ventilation to meet air requirement for combustion and heat removal with provn of a blower.(v) Emergency stop push button out side the container.(vi) Provn of light inside the canopy 20 W LED fitting with wiring and control switch.(vii) Including Auto Mains Failure(AMF) Panel with ATS switch including control wiringNote:- The plinth should be as per Manufacturer Recommendation and the rate of plinth is deemed to be included in quoted rate. complete all as specified & directed. |
| 4 | Supply, installation, commissioning and testing of ECO friendly Diesel Engine driven silent type ,acoustic enclosure made out of CRCA sheet generating set outdoor type of capacity 40KVA or nearest higher capacity, suitable HP , latest CPCB IV+ emission compliant 415 volts AC, 3 phase and neutral wire, 50 HZ, 4 wire, 0.8 PF, Governing as per manufacturer norms, noise level <75 dBA @ 1 mtr, fuel tank capacity as per manufacturer recommendation, electrical battery starting volt-24 V DC, directly coupled alternator, measuring display board etc common steel base fixed on cement concrete in foundation as per OEM recommendation platform with inbuilt AMF panel as per manufacturer recommendation and other accessories comprising of following :-Make-Genset model No C40D5P, Engine cummins modelX2.6-G2 and alternator of MakeSTAMFORD (CGT), DIESEL ENGINE ECO friendly, 4 stroke diesel Engine confirming to BS std developing suitable BHP @ 1500 RPM turbo charged water cooled complete with a provision of 10 % overload for 1 hour.(i) Fly wheel with starter ring for generating set.(ii) Dry type air filter.(iii) Lube oil cooler assembly with accessories.(iv) Exhaust air manifold.(v) Exhaust silencer.(vi) Expansion bellow.(vii) Exhaust gas turbocharger.(viii) Fuel filter (pre micro)(ix) Oil filter(x) 12V or 24V DC as per manufacturer norms electrical starting system with starting motor & battery charging alternator with self starter and other auto electric accessories as recommended by manufacturer. |
| 5 | (xi) Centrifugal by pass filter(xii) Front and rear mounting support.(xiii) Engine control panel consisting of OFF/ON/START keys lub oil pressure gauge, Ammeter, Electric hour meter, speedo meter(xiv) Safety against low lube oil(xv) Engine test certificate(xvi) Cold starting kit(xvii) Engine main manual with spare part list(xviii) Governer as per manufacturer norms(xix) Cooling radiator with first fill coolent.ALTERNATOR Silent pole brushless copper wound type suitable for direct couple to engine self excited, self regulated with fast response thyristor type electronic automatic voltage regulator with output voltage within desired limit(+1%) Dynamicaly balanced 415 V , AC, 3 PHASE, 50 Hz, 4 wire 0.8 PF lagging 82.5 KVA insulator class \"H\",1500 RPM star connected screen protected drip proof enclousers with radial fan mounted on rotor with insulated class H with following acessaries :-(i) One MS frame suitable for mounting of Engine and Alternator.(ii) Fuel tank of suitable capacity as per manufacturer recommendation complete withfuel gauge inlet/outlet connections drain valve with plug etc.(iii) Battery of suitable capacity with copper leads and terminal leads of suitable size.(iv) One set of AVM pads fitted on base frame. |
| 6 | (C) Acoustic Enclosure Supply and install of Acoustic Enclosure suitable for 40 KVADG set the degree of protection IP-42 confirming to IS-2147 as under:-(i) Fabricated out of CRCA sheet of suitable size as per manufacturer design. Polysterbased powder coated internaly and externaly with lockable type door handle. All nutsand handles shall be zinc coated.(ii) The door are gasketed with EPDM gaskets.(iii) Sound proofing with high quality rock wool/mineral wool confirming to IS 8183 of 50mm thickness and density at 96 kg/m³ covered with fiber glass cloth and perforatedpowder coats sheet specially designed allenuators (sound controller) at air entry andexit of the container noise level shall be not exceed 75 dB at 1 meter distance as perCPCB norms.(iv) Adequate ventilation to meet air requirement for combustion and heat removal withprovn of a blower.(v) Emergency stop push button out side the container.(vi) Provn of light inside the canopy 20 W LED fitting with wiring and control switch. (vii) Including Auto Mains Failure(AMF) Panel with ATS switch including control wiringNote:- The plinth should be as per Manufacturer Recommendation and the rate of plinth is deemed to be included in quoted rate. complete all as specified & directed. |
| 7 | M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 32x6 mm as earthing lead by means ofnut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 8 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95sq mm 3.5 core complete all as specified and directed. |
| 9 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and directed. |
| 10 | Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth, for cable, etc n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense soil for cable and Pole complete all as specified and directed. |
| 11 | Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed. |
| 12 | Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 13 | Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note: Punned thickness shall be measured for the purpose of payments. |
| 14 | Supply and laying burnt bricks old size sub class-B laid in trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and directed. |
| 15 | Supply and lay GI tube light grade with all fittings and fixed complete to walls and ceilings or laid in floors of size50 mm dia all as specified and directed |
| 16 | Supply, installation and commissioning and fix room window type air conditioner with inverter compressor, electric driven (single phase),cooling capacity 6000 K Cal per hour ( 1.5 Ton), BEE 5 star rated, having copper condenser coil, using R32 refrigerant, stabilizer free operation within 170-265 voltage, LED display, self diagnosis, sleep mode, turbo mode, easily removable panel, ultra silent including dismantling ofwindow type air conditioner andwriting MES Nocomplete all as specified all as specified and as directed.Note: Old U/Swindow type air conditioner shall be deposited in E/M store yard Make: Dakin/ Hitachi / O-genral/ Mitubishi Industries / Carrier |
| 17 | Supply, installation and commissioning and fix room window type air conditioner with inverter compressor, electric driven (single phase),cooling capacity 6000 K Cal per hour ( 2 Ton), BEE 5 star rated, having copper condenser coil, using R32 refrigerant, stabilizer free operation within 170-265 voltage, LED display, self diagnosis, sleep mode, turbo mode, easily removable panel, ultra silentincluding dismantling ofwindow type air conditioner andwriting MES Nocomplete all as specified all as specified and as directed.Note: Old U/Swindow type air conditioner shall be deposited in E/M store yard Make: Dakin/ Hitachi / O-genral/ Mitubishi Industries / Carrier |
| 18 | Supply and install and testing split type air conditioner of capacity 1.5 Ton, with minimum 5 star rating and EER 3.2 for working on 230 volt, SP, 50 Hz including cutting of existing wall and properfixing making good disturbed surface with existing surface and providing water pipe upto ground level and copper tubing upto 7.5mtr connecting inner unit with outer unit and base plate for mounting of outer unit of AC including dismantling of split type air conditioner andwriting MES Nocomplete all as specified all as specified and as directed.Note: Old U/Ssplit type air conditioner shall be deposited in E/M store yard Make: Dakin/ Hitachi / O-genral/ Mitubishi Industries / Carrier |
| 19 | Supply and install and testing split type air conditioner of capacity 2.0 Ton, with minimum 5 star rating and EER 3.2 for working on 230 volt, SP, 50 Hz including cutting of existing wall and properfixing making good disturbed surface with existing surface and providing water pipe upto ground level and copper tubing upto 7.5mtr connecting inner unit with outer unit and base plate for mounting of outer unit of AC including dismantling of split type air conditioner andwriting MES Nocomplete all as specified all as specified and as directed.Note: Old U/Ssplit type air conditioner shall be deposited in E/M store yard Make: Dakin/ Hitachi / O-genral/ Mitubishi Industries / Carrier |
| 20 | Supply and fix refrigerator, electric driven (single phase), capacity 286 Litres or higher capacity, BEE 5 star rated with digital Inverter Compressor, frost free, Auto defrost, digital temp control, Door Ajar alarm, low noise, having adjustable shelves, stabilizer free opeartion (100 -300V) including dismantling of refrigerator andwriting MES Nocomplete all as specified all as specified and as directed.Note: Old U/Srefrigerator shall be deposited in E/M store yard |
| 21 | Supply and fix refrigerator, electric driven (single phase), capacity 185 Litres or higher capacity, BEE 5 star rated with digital Inverter Compressor, frost free, Auto defrost, digital temp control, Door Ajar alarm, low noise, having adjustable shelves, stabilizer free opeartion (100 -300V) including dismantling ofrefrigerator andwriting MES Nocomplete all as specified all as specified and as directed.Note: Old U/Srefrigerator shall be deposited in E/M store yard |
| 22 | Supply and fix water cooler electric driven (single phase), having approx storage capacity of 180 litres and nominal cooling capacity of 150 Litres per hour, equipped with hermetically sealed, reciprocating compressor and R 134s refrigerant for reliable and consistent cooling performance, entire body of the cooler be crafted fromm stainless steel including dismantling ofwater cooler andwriting MES Nocomplete all as specified all as specified and as directed.Note: Old U/S water cooler shall be deposited in E/M store yard |